Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid impact analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

A Sustainable Wind–Biogas Hybrid System for Remote Areas in Jordan: A Case Study of Mobile Hospital for a Zaatari Syrian Refugee Camp

Access to reliable and sustainable energy in remote areas remains a pressing global challenge, significantly affecting economic development and the quality of life. This study focuses on the implementation of fully off-grid wind–biogas hybrid power systems to address this issue, with a focus on remote healthcare camp facilities. This paper investigates the performance of a hybrid renewable energy system within the context of one of Jordan’s northern remote areas, the Zaatari Syrian Refugee Camp, assessing its efficiency and environmental impact by taking the Zaatari hospital as the case study. Simulations were conducted to evaluate system components, including wind turbines, biogas generators, and diesel generators. A comprehensive evaluation was conducted, encompassing both the operational efficiency of the system and its impact on the environment. This study also considered various scenarios (SC#), including grid availability and autonomy levels, to optimize system configurations. The techno-economic assessment employed the levelized cost of energy (LCOE) as a key performance indicator, and sensitivity analyses explored the impact of diesel costs and wind power fluctuations on the system. Additionally, environmental assessment was conducted to evaluate the environmental effects of hybrid systems, with a specific focus on reducing greenhouse gas emissions. This investigation involved an examination of emissions in three different scenarios. The results indicate that the lowest LCOE that could be achieved was 0.0734 USD/kWh in SC#1 with 72.42% autonomy, whereas achieving 100% autonomy increased the LCOE to 0.1756 USD/kWh. Additionally, the results reveal that in scenarios SC#2 and SC#3, which have a higher proportion of diesel generator usage, there were elevated levels of NO x and CO 2 emissions. Conversely, in SC#1, which lacks diesel generators, emissions were notably lower. The proposed hybrid system demonstrates its potential to provide a reliable energy supply to healthcare facilities in remote regions, emphasizing both economic feasibility and environmental benefits. These findings contribute to informed decision making for sustainable energy solutions in similar contexts, promoting healthcare accessibility and environmental sustainability.

09 BIOMASS FUELS↗

Combining CO2 Electrolysis with Biological Upgrading to Fuels and Chemicals: Turning Waste into Fuels

The utilization of flue gas-derived CO2 presents an opportunity to enhance carbon utilization in the bioethanol industry, contributing to the production of valuable products. In the context of a 90 million-gallon-per-year corn ethanol plant generating approximately 30 tons per hour of 99% pure CO2, a collaborative effort involving six national laboratories has been established. This initiative, known as the CO2 Reduction and Upgrading for e-Fuels (CO2RUe) Consortium, is funded by the Department of Energy's BioEnergy Technologies Office (BETO). The primary objective of the CO2RUe Consortium is to explore innovative approaches to harness CO2 as a valuable feedstock. This interdisciplinary consortium integrates electrochemistry with biological upgrading techniques, aiming to yield sustainable, value-added products and aviation fuels. The presentation will delve into the recent advancements in the realms of electrochemistry and biological upgrading, with a specific focus on formic acid and CO. Additionally, the talk will include an analysis of future electricity grid scenarios, technoeconomic evaluations, and life-cycle assessments. These assessments aim to provide a comprehensive understanding of the impacts of various conversion pathways on both cost and carbon intensity. The CO2RUe Consortium is at the forefront of steering the development of economically favorable and sustainable processes for CO2 utilization. The presentation will showcase the consortium's progress in driving the advancement of technology and processes, emphasizing the economic viability and sustainability of CO2 utilization within the broader context of the bioethanol industry.

biological upgrading↗

Interconnection Cost Analysis in ISO-New England

Electric transmission system operators (ISOs, RTOs, or utilities) require new large generators seeking to connect to the grid to undergo a series of impact studies before they can be built. This process establishes what new transmission equipment or upgrades may be needed before a project can connect to the system and assigns the costs of that equipment. Berkeley Lab has collected interconnection cost data for 194 projects in New England from interconnection studies performed between 2010 and 2021. Project-level cost summary data are available for download on this page. We find: -Interconnection costs have grown over time, especially for projects that withdraw. -Interconnection costs are highest for onshore wind, followed by solar and storage. Natural gas and offshore wind projects tend to cost less to interconnect, in comparison. -Economies of scale exist for solar and possibly storage projects, but not for other resource types. -Wind and solar projects requesting capacity network resource interconnection service have higher interconnection costs, despite being evaluated using the same interconnection standard in the analyzed studies. -Low and high interconnection costs can be found throughout the ISO-NE footprint. -Costs are split fairly evenly between investments at the point of interconnection and within the broader network for active and withdrawn projects, while complete projects incur most costs at the point of interconnection.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of Grid-Forming Inverter Controls for Grid-Connected and Islanded Microgrid Integration

Autonomous grid-forming (GFM) inverter testbeds with scalable platforms have attracted interest recently. In this study, a self-synchronized universal droop controller (SUDC) was adopted, tested, and scaled in a small network and a test feeder using a real-time simulation tool to operate microgrids without synchronous generators. We presented a novel GFM inverter control adoption to better understand the dynamic behavior of the inverters and their scalability, which can impact the distribution system (DS). This paper provides a steady-state and transient analysis of the GFM power inverter controller via simulation to better understand voltage and frequency stabilization and ensure that the critical electric loads are not affected during a prolonged power outage. The controllers of the GFM inverter are simulated in HYPERSIM to examine voltage and frequency fluctuations. This analysis includes assessing the black start capability for photovoltaic microgrids, both grid-connected and islanded, during transient fault conditions. The high photovoltaic PV penetration levels open exciting opportunities and challenges for the DS. The GFM inverter control demonstrated appropriate response times for synchronization, connection, and disconnection to the grid. The DS has become more resilient and independent of fossil fuels by increasing the penetration of inverter-based distributed energy resources (DERs).

Ward, Laura (ORCID:0000000345501581)↗

Aging Effect Analysis of PV Inverter Semiconductors for Ancillary Services Support

PV inverters can provide reactive power while generating active power. An ongoing microgrid implementation at Duke Energy actively engages non-utility PVs to generate/absorb reactive power in support of ancillary services to increase microgrid resiliency during extreme events. PV systems are requested to provide reactive power support: 1) in response to grid voltage variation to better regulate the local voltage; or 2) in response to utility incentives, such as following Transactive Energy System (TES) incentives. However, providing ancillary services might shorten the lifetime expectation of PV inverter semiconductors. This paper summarizes the potential impacts on a PV inverter semiconductor's lifetime when providing ancillary services. The analysis presented in this research work shows that providing reactive power support will increase the mean junction temperature and the junction temperature variation of the inverter diodes. This increased junction temperature will eventually lead to shorter diode lifetime. The lifetime estimation of semiconductors is briefly reviewed. The power losses of PV inverter semiconductors are derived as a support analysis to the junction temperature calculation. In addition, the impact of the filtering inductor on the semiconductor current distribution is discussed. The theoretical analysis presented in this research work is supported by simulation results.

14 SOLAR ENERGY↗

PR100: Puerto Rico Grid Resilience and Transition to 100% Renewable Energy

The Puerto Rico Grid Resilience and Transitions to 100% Renewable Energy Study (PR100) comprehensively analyzes possible pathways for Puerto Rico to achieve its renewable energy goals while incorporating stakeholder perspectives and advancing energy resilience for all Puerto Ricans. PR100 is a wide-ranging and in-depth examination of Puerto Rico's energy system investment options. The findings are the culmination of two years of stakeholder engagement, scenario modeling, and impact analysis. The PR100 report and Implementation Roadmap contain a range of results and actions that reflect Puerto Rico's priorities around energy justice, resilience, and reliability. Led by the U.S. Department of Energy's Grid Deployment Office with funding from the Federal Emergency Management Agency, the PR100 study leveraged and integrated dozens of best-in-class models and in-depth analyses from researchers across six national laboratories: National Renewable Energy Laboratory (which led the study), along with Argonne National Laboratory, Lawrence Berkeley National Laboratory, Oak Ridge National Laboratory, Pacific Northwest National Laboratory, and Sandia National Laboratories (which conducted the study). For more information, please see the "PR100 Project Website" resource below.

Array↗

A Reversed Impedance-Based Stability Criterion for IBR Grids

The existing impedance-based stability criterion is effective for analyzing local control interactions; however, it is difficult to scale the existing criterion to analyze wide-area control interactions among numerous IBRs through a complex power system network. The scaled version of the existing criterion requires the impedance response of each IBR in the system as well as of the network looking from all the IBRs. It is quite challenging to obtain all these impedance responses because of the computational effort and the requirement of separately scanning the impedance of the network and the IBRs. We propose a reversed criterion for the impedance-based stability analysis to address these problems. In contrast to the existing criterion, the reversed criterion analyzes the stability of a power system when an IBR is disconnected from the system. The reversed criterion estimates the impact of an IBR on the frequency and damping of power system oscillation modes using the impedance scans of only the IBR and the grid at its terminal. It can be sequentially applied at different IBRs to evaluate their impact on the power system stability. In addition to scalability, the reversed criterion gives flexibility to focus only on a few selected IBRs, depending on their rating, the magnitude of oscillations observed at their terminals, and the vendor support available for implementing stabilizing control system updates. The reversed criterion is demonstrated on a 14-bus power system with 100% IBRs.

control interactions↗

Energy, power, and infrastructure demands from electrifying airport ground support equipment at United States airports

As the airline industry seeks to reduce costs and transition to clean energy, electric ground support equipment is emerging as a favorable option. The integration of electric ground support equipment into airport operations requires careful planning for vehicle deployment, charging infrastructure, and grid impacts. We develop a flexible, bottom-up modeling framework to assess energy and infrastructure needs across more than 300 U.S. airports. Our analysis estimates site-specific power and energy demand, equipment counts by type, charger requirements, and costs. Here we quantify the magnitude of new electrical loads created by the electrification of airport ground support equipment, finding that peak power demand at the largest airports can reach up to 20 megawatts, with annual electricity consumption approaching 51,000 megawatt-hours. We further show that behind-the-meter battery energy storage systems and solar photovoltaic systems can reduce peak load and lower total system costs by as much as 10 million dollars.

24 POWER TRANSMISSION AND DISTRIBUTION↗

WECC Wide-Area Oscillation Assessment and Trending Study Report

This project, Wide-area Oscillation Analysis and Trending Study, is sponsored by the Office of Electricity (OE) of the Department of Energy (DOE) who tasked Northwest National Laboratory (PNNL) to conduct this research. Staff of Federal Energy Regulatory Commission (FERC) have been involved in the project as observers and have provided advisory comments and suggestions. The primary objective of this study is to assess whether there are significant trends in the wide-area oscillatory behavior with respect to the significant generation-mix changes brought by the increased penetration of RES in the WECC system. The work performed in this project is considered to be complimentary to previous work by NERC/industry and covers the aspects that have not been studied or trended before. The trending analysis presented in this report can serve as reference for future grid planning and operation of the WECC system. In this report, how the changes in the generation mix can impact the frequency and damping ratio (DR) of WECC wide-area oscillation modes has been studied. Thorough data-based and model-based analyses have been carried out to analyze the current trends and then extended to evaluate the oscillation behaviors of the future WECC system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance Metrics to Evaluate Utility Resilience Investments

In 2019, Sandia National Laboratories (Sandia) contracted Synapse Energy Economics (Synapse) to research the integration of community and electric grid resilience investment planning as part of the Designing Resilient Communities (DRC): A Consequence-Based Approach for Grid Investment project. Synapse produced a series of reports to explore the challenges and opportunities in several key areas, including benefit-cost analysis (BCA), performance metrics, microgrids, and regulatory mechanisms. This report focuses on BCA. BCA is an approach that electric utilities, electric utility regulators, and communities can use to evaluate the costs and benefits of a wide range of grid resilience investments in a comprehensive and consistent way. While BCA is regularly applied to some types of grid investments, application of BCA to grid resilience investments is in the early stages of development. Though resilience is increasingly cited in connection with grid investment proposals and plans, the resilience- related costs and benefits of grid resilience investments are typically not fully identified, infrequently quantified, and almost never monetized. Without complete assessments of costs and benefits, regulators can be hesitant to approve some types of grid resilience investments. This report provides the first application of the framework developed in the 2020 National Standard Practice Manual for Benefit-Cost Analysis of Distributed Energy Resources (NSPM for DERs) to grid resilience investments. We provide guidance on next steps for implementation to enable grid resilience investments to receive due consideration. We suggest developing BCA principles and standards for jurisdiction-specific BCA tests. We also recommend identifying the resilience impacts of the investments and quantification of these impacts by establishing utility performance metrics for resilience. Proactive integration of grid resilience investments into existing regulatory processes and practices can increase the capacity of jurisdictions to respond to and recover from the consequences of extreme events. 1 National Energy Screening Project. 2020. National Standard Practice Manual for Benefit-Cost Analysis of Distributed Energy Resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Analysis of Grid Operator Survey Responses: Inexperience, Workload and Fatigue in the Control Room

Although a wide array of tools and technologies have been developed over the last decade to support power grid operators, deployment of these tools has been less successful. One reason for unsuccessful deployment may be an inadequate understanding of the factors that contribute to operator error in the control room. An analysis of operators’ current vulnerabilities may provide the baseline understanding needed to inform new technology integration. In an attempt to learn more about these vulnerabilities and their perceived impact on human error we collected and analyzed survey data from 20 electric grid control room operators. We asked survey respondents to consider the various operator, technology and interaction vulnerabilities that may arise during work in the control room and record their attitudes and experiences toward each. Results suggest operator inexperience, high mental workload and fatigue are the most common vulnerabilities experienced during a shift. Survey results were analyzed to explore these vulnerabilities in greater depth.

Inexperience, Workload, Fatigue↗

esm_watermasses

A water mass analysis package for gridded ocean and atmospheric data and Earth system model output

Moore-Maley, Ben [@SciDAC-ImPACTS @E3SM-Project @M↗

Generator Interconnection Cost Analysis in the Southwest Power Pool (SPP) Territory

Electric transmission system operators (ISOs, RTOs, or utilities) require new large generators seeking to connect to the grid to undergo a series of impact studies before they can be built. This process establishes what new transmission equipment or upgrades may be needed before a project can connect to the system and assigns the costs of that equipment. Berkeley Lab has collected interconnection cost data for 845 projects from interconnection studies for the Southwest Power Pool (SPP) Territory. The studies were performed between 2002 and 2023 and include all of the most refined cost estimates available. Project-level cost summary data are available for download on this page. We find: -Project-specific interconnection costs can differ widely. -Average interconnection costs are stable for projects that complete all interconnection studies but have escalated for those that withdraw. -Broader network upgrade costs are the primary driver of recent cost increases, especially for withdrawn projects. -Potential interconnection costs of all solar and wind requests have been greater than those of storage and natural gas projects. -Economies of scale exist for completed wind and solar projects but not for other fuel types or withdrawn projects. -Interconnection costs vary by location. Berkeley Lab publishes a series of short analytical papers of generator interconnection costs to the transmission system for MISO, PJM, SPP, ISO-NE and NYISO, which you can find at https://emp.lbl.gov/interconnection_costs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Measurement of Photovoltaic Module Deformation Dynamics During Hail Impact Using Digital Image Correlation

Stereo high-speed video of photovoltaic modules undergoing laboratory hail tests was processed using digital image correlation to determine module surface deformation during and immediately following impact. The purpose of this work was to demonstrate a methodology for characterizing module impact response differences as a function of construction and incident hail parameters. Video capture and digital image analysis were able to capture out-of-plane module deformation to a resolution of ±0.1 mm at 11 kHz on an in-plane grid of 10 × 10 mm over the area of a 1 × 2 m commercial photovoltaic module. With lighting and optical adjustments, the technique was adaptable to arbitrary module designs, including size, backsheet color, and cell interconnection. Furthermore, impacts were observed to produce an initially localized dimple in the glass surface, with peak deflection proportional to the square root of incident energy. Subsequent deformation propagation and dissipation were also captured, along with behavior for instances when the module glass fractured. Natural frequencies of the module were identifiable by analyzing module oscillations postimpact. Limitations of the measurement technique were that the impacting ice ball obscured the data field immediately surrounding the point of contact, and both ice and glass fracture events occurred within 100 μs, which was not resolvable at the chosen frame rate. Increasing the frame rate and visualizing the back surface of the impact could be applied to avoid these issues. Applications for these data include validating computational models for hail impacts, identifying the natural frequencies of a module, and identifying damage initiation mechanisms.

14 SOLAR ENERGY↗

Generator Interconnection Cost Analysis in the Midcontinent Independent System Operator (MISO) territory

Electric transmission system operators (ISOs, RTOs, or utilities) require new large generators seeking to connect to the grid to undergo a series of impact studies before they can be built. This process establishes what new transmission equipment or upgrades may be needed before a project can connect to the system and assigns the costs of that equipment. Berkeley Lab has collected interconnection cost data from interconnection studies for the Midcontinent Independent System Operator (MISO), representing nearly 50% of all projects requesting interconnection from 2010 to 2020. Project-level cost summary data are available for download on this page. We find: -Average interconnection costs have grown as the number of interconnection requests have escalated -Projects that have completed all required interconnection studies have the lowest cost compared to applicants still actively working through the interconnection process or those that have withdrawn. -Broader network upgrade costs are the primary driver of recent cost increase. -Potential interconnection costs for wind, storage, and solar are larger than for natural gas -Larger generators have greater interconnection costs in absolute terms, but economies of scale exist on a per kW basis. -Interconnection costs vary by location Berkeley Lab will publish a series of short analytical papers of generator interconnection costs to the transmission system for MISO, PJM, SPP, ISO-NE and NYISO, which you can find at https://emp.lbl.gov/interconnection_costs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Performance analysis of hybrid power configurations: Impact on primary energy intensity, carbon dioxide emissions, and life cycle costs

In this work, utilization of Natural gas and Hydrogen to support current and future building energy needs to offset the total electric demand while improving the grid resiliency and energy efficiency was investigated. Demand side energy management will play an important role in efficiently managing the available energy resources. Performance assessment of different power generation and energy management configurations is presented in this paper. Development of solutions in addressing grid resiliency by providing the ability to design suitable configurations for meeting individual building energy needs is discussed. Primary movers (PM) such as internal combustion engines (ICE) and fuel cells (FC) along with small scale auxiliary renewable energy source such as photovoltaics (PV) were considered. Key attributes of total carbon foot-print, life cycle costs including capital and operational expenditure, electric grid offset or peak shaving capability, thermal energy availability and its further potential to offset total electric demand, and primary energy intensity are analyzed and discussed in detail.

08 HYDROGEN↗

Analysis of Energy Justice and Equity Impacts from Replacing Peaker Plants with Energy Storage

Transitions to low-carbon energy systems are essential to mitigating and adapting to climate change. Energy storage systems are a key component in achieving a viable decarbonized electric grid. However, decarbonization alone does not guarantee a fairer, more inclusive, or socially just energy system. Energy equity and justice should be integrated in energy system transitions to ensure benefits and burdens are shared equitably. In this paper, we discuss the relationship between energy storage and social equity by assessing the use of energy storage to replace natural gas-fired (NG) peaker plants. Peaker plants are disproportionately located near disadvantaged communities and tend to be older and high emitters of health-affecting fine particulate matter and other pollutants. This paper investigates the equity implications of NG peaker plant replacements with battery energy storage in the context of Washington State’s peaker plants to highlight the human-centered values of retiring the plants. The study performed production cost simulations using the latest Western Electric Coordinating Council Anchor Dataset 2030 case and found that total generation cost, locational marginal price, and total annual emissions were reduced with the replacements. These reductions will have equity benefits on local communities including access to clean air, enhanced health outcomes, and energy burden reductions.

Tarekegne, Bethel W.↗

Lake-Effect Snowstorm Events and Associated Snowfall Totals Integrated from NOAA Storm Reports, ERA5, and HRRR for the Laurentian Great Lakes (1997–2024)

Lake-effect snowstorms are localized, impactful winter weather phenomena that can generate substantial snowfall totals and pose significant challenges for forecasting, transportation, and regional infrastructure. To support the analysis and modeling of these events, this dataset compiles observational reports of lake-effect snowstorms alongside corresponding snowfall estimates derived from gridded atmospheric datasets. The observational component of the data originates from the National Weather Service (NWS) winter storm report, subset to lake-effect snow event type, covering 1997–2024. For each lake-effect snow event, this data provides the impacted county, event start and end datetimes at an hourly resolution, as well as relevant storm narratives. The complementary reanalysis-derived data is sourced from European Centre for Medium-Range Weather Forecasts (ECMWF) Reanalysis 5 (ERA5) and High-Resolution Rapid Refresh (HRRR) gridded data. For both gridded datasets, the maximum total snowfall (in units mm) was extracted, constrained by the county and datetimes specified by the observational report. ERA5 data covers the entire observational period (1997–2024), whereas HRRR data is only available from November 2016 – December 2024. Three CSV files are provided here: (1) the observational lake-effect snow event report, (2) ERA5 maximum snowfall detections for each event, and (3) HRRR maximum snowfall detections for each event. Relevant data from the observational files, such as impacted state and county, event datetimes, and event IDs, were included for convenience. Users can inspect and visualize the data using tools such as Microsoft Excel and Python pandas/matplotlib packages. This dataset may support a variety of applications, including climatological analyses of lake-effect snowfall, evaluation of snowfall representation in atmospheric datasets and numerical weather prediction models, and the development of machine learning approaches for detecting or predicting lake-effect snowfall events.

EARTH SCIENCE > ATMOSPHERE > PRECIPITATION > SOLID↗