Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid analysis and integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Integrated Multi-Satellite Evaluation for the Global Precipitation Measurement: Impact of Precipitation Types on Spaceborne Precipitation Estimation

Integrated multi-sensor assessment is proposed as a novel approach to advance satellite precipitation validation in order to provide users and algorithm developers with an assessment adequately coping with the varying performances of merged satellite precipitation estimates. Gridded precipitation rates retrieved from space sensors with quasi-global coverage feed numerous applications ranging from water budget studies to forecasting natural hazards caused by extreme events. Characterizing the error structure of satellite precipitation products is recognized as a major issue for the usefulness of these estimates. The Global Precipitation Measurement (GPM) mission aims at unifying precipitation measurements from a constellation of low-earth orbiting (LEO) sensors with various capabilities to detect, classify and quantify precipitation. They are used in combination with geostationary observations to provide gridded precipitation accumulations. The GPM Core Observatory satellite serves as a calibration reference for consistent precipitation retrieval algorithms across the constellation. The propagation of QPE uncertainty from LEO active/passive microwave (PMW) precipitation estimates to gridded QPE is addressed in this study, by focusing on the impact of precipitation typology on QPE from the Level-2 GPM Core Observatory Dual-frequency Precipitation Radar (DPR) to the Microwave Imager (GMI) to Level-3 IMERG precipitation over the Conterminous U.S. A high-resolution surface precipitation used as a consistent reference across scales is derived from the ground radar-based Multi-Radar/Multi-Sensor. While the error structure of the DPR, GMI and subsequent IMERG is complex because of the interaction of various error factors, systematic biases related to precipitation typology are consistently quantified across products. These biases display similar features across Level-2 and Level-3, highlighting the need to better resolve precipitation typology from space and the room for improvement in global-scale precipitation estimates. The integrated analysis and framework proposed herein applies more generally to precipitation estimates from sensors and error sources affecting low-earth orbiting satellites and derived gridded products.

Rainfall↗

Scalable and Secure Power Outage Data Reporting: A Hexagonal Geospatial Approach

Power outages disrupt critical infrastructure and cause billions of dollars in economic losses annually in the United States. Accurate and granular outage reporting is vital for effective restoration and mitigation. This paper examines the integration of the Hexagonal Hierarchical Geospatial Indexing System (H3) to enhance power outage reporting, leveraging its uniform grid structure, scalable resolutions, and support for privacy-preserving analysis. Using high-resolution LandScan Global population data and K-anonymization techniques, this work achieves a balance between data granularity and privacy. Results show that lower privacy thresholds (e.g., K-anonymity = 2) enable higher resolution, while stricter thresholds (e.g., >15 people per hex) reduce granularity, potentially affecting localized responses. State-and county-level resolution case studies demonstrate H3’s adaptability and the trade-offs between precision and privacy. The proposed H3-based framework offers a scalable and efficient solution for geospatial data integration within the energy sector, such as outage data, aiding utilities and regulators in improving resilience and response efforts, particularly in disaster-prone regions.

Ahmad, Nasir [ORNL] (ORCID:0000000150677368)↗

Multiscale Electrothermal Design of a Modular Multilevel Converter for Medium-Voltage Grid-Tied Applications

As a key feature of modular multilevel converters (MMCs), a large number of semiconductor devices are employed in the converter and distributed over a stack of submodules. Each submodule has a strict temperature limit that imposes constraints on the operating range of the converter. Different loading conditions/losses in the submodules lead to unavoidable temperature variations inside the MMC, which consequently affect the system-level performance and reliability. This paper is focused on the electrothermal analysis and design of a medium-voltage silicon carbide (SiC)-based MMC system, from submodule power semiconductors to the overall MMC system integration of multiple submodules, for grid-connected applications. Loss calculations are performed to estimate the cooling requirements and aid thermal design at different levels. The performance of a forced-air cooling approach is analyzed within a numerical modeling framework. Maximum temperature of the SiC power modules is predicted using numerical tools. Thermal design of the MMC cabinet with various arrangements of air inlet(s) and outlet(s) is investigated and compared from a cooling performance perspective. A fully resolved model of the arrangement that yields optimal results is developed to accurately predict the temperature profile of the essential components in the submodules.

computational fluid dynamics↗

A State-Space Model for Stability Boundary Analysis of Grid-Following Voltage Source Converters Considering Grid Conditions

With the growing significance of renewable energy resources and energy storage systems, the number of grid-connected inverters has been rising at an increasingly rapid pace. Generally, these inverters are directly integrated with the distribution network by synchronizing with the grid voltage at the point of common coupling. However, the low grid strength and varying R/X ratios, as the common characteristics of most distribution networks or weak grids, can lead to dynamic interactions that comprise stability and limit the power transfer capacity of grid-connected inverters. To ensure stable operation of the inverters, researchers must determine the stability boundary, described as the maximum power transfer capacity of grid-connected inverters under the premise of maintaining system small-signal stability. For this purpose, we propose to formulate a state-space model of the system in the synchronously rotating dq-frame of reference and perform eigenvalue analysis to determine the stability boundary. With a detailed model of the control structure and parameters of the grid-connected inverters, the stability boundary is identified as a surface with respect to different grid strengths and R/X ratios. Case study results of proposed eigenvalue analysis are compared with those of admittance model-based stability analysis as well as time-domain simulation using a switching model in Matlab/Simulink, validating the effectiveness and accuracy of the proposed eigenvalue analysis for stability boundary identification.

grid-connected inverters↗

Asynchronous Grid Connections Providing Fast-Frequency Response: System Integration Study

This paper presents an integration study for the recent power electronic-based fast-frequency response technology, "asynchronous grid connection" which operates as an aggregator for behind-the-meter resources and distributed generators. Both technical feasibility and techno-economic viability studies are presented. The fast-frequency response characteristics, validated against Power Hardware-in-the-Loop experiments, are integrated into an IEEE 9- bus system in DigSilent PowerFactory for system-level dynamic analysis. It demonstrates that droop-based control enhancements to local distributed generators allow their aggregation to provide grid-supporting functionalities and participate in the ancillary service markets. To this end, a long-term simulation embedding the system within the ancillary service market framework of PJM has been performed. The fast-frequency response regulation is subsequently used to calculate the potential revenue and project the results on a 15-year investment horizon. Finally, the techno-economic analysis provides recommendations for enhancements to access the full potential of distributed generators on a technical and regulatory level.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhancing Power Grid Resilience with Causal Loops Diagram and Bayesian Networks

Enhancing power grid resilience through improved analysis and planning of Distributed Energy Resources is a key for power system planner. This paper explores the integration of Causal Loop Diagrams (CLDs) and Bayesian Networks (BNs) for enhancing resilience in power systems, focusing on Distributed Energy Resources (DER) planning. By automating CLD analysis in Python's matplotlib, we present a tool for rapid model validation and structural accuracy, crucial for power system planners. This hybrid approach utilizes BNs for inferential depth and CLDs for dynamic system modeling, offering a comprehensive framework for policy formulation and collaborative strategy development against disruptions. Here, we highlight the tool's capability to identify and analyze interconnected feedback loops, facilitating a deeper understanding of DER integration's impact on network resilience. This work aims to bridge quantitative analysis and qualitative insights, addressing the limitations of each method while providing a robust model for power system resilience assessment.

14 SOLAR ENERGY↗

Detection and Diagnosis of Data Integrity Attacks in Solar Farms Based on Multilayer Long Short-Term Memory Network

Photovoltaic (PV) systems are becoming more vulnerable to cyber threats. In response to this emerging concern, developing cyber-secure power electronics converters has received increased attention from the IEEE Power Electronics Society that recently launched a cyber-physical-security initiative. Here this letter proposes a deep sequence learning based diagnosis solution for data integrity attacks on PV systems in smart grids, including dc–dc and dc–ac converters. The multilayer long short-term memory networks are used to leverage time-series electric waveform data from current and voltage sensors in PV systems. The proposed method has been evaluated in a PV smart grid benchmark model with extensive quantitative analysis. As a comparison, we have evaluated classic data-driven methods, including K-nearest neighbor, decision tree, support vector machine, artificial neural network, and convolutional neural network. Comparison results verify performances of the proposed method for detection and diagnosis of various data integrity attacks on PV systems.

42 ENGINEERING↗

EVs@Scale Deep Dive - SCM/VGI (Day 1: SCM/VGI Analysis)

The U.S. Department of Energy (DOE) Electric Vehicles at Scale Laboratory Consortium (EVs@Scale Lab Consortium) is accelerating research to support the establishment of a secure and scalable national network of charging infrastructure. Critical to this effort is an understanding of the potential grid impacts of EV charging and possible smart charge management (SCM) or vehicle-grid integration (VGI) capabilities that could mitigate these impacts. The EVs@Scale SCM/VGI Pillar is analyzing the impacts of EV charging and developing and demonstrating the capabilities of both SCM and VGI with many different vehicle use cases and grid scenarios. This Deep Dive Discussion from year 1 of the project encompasses the progress and future plans for the analysis components of the FUSE (Flexible charging to Unify the grid and transportation Sectors for Evs at scale) project.

ADVANCED PROPULSION SYSTEMS↗

Helicopter Non-Unique Trim Strategies for Blade-Vortex Interaction (BVI) Noise Reduction

An acoustics parametric analysis of the effect of fuselage drag and pitching moment on the Blade-Vortex Interaction (BVI) noise radiated by a medium lift helicopter (S-70UH-60) in a descending flight condition was conducted. The comprehensive analysis CAMRAD II was used for the calculation of vehicle trim, wake geometry and integrated air loads on the blade. The acoustics prediction code PSU-WOPWOP was used for calculating acoustic pressure signatures for a hemispherical grid centered at the hub. This paper revisits the concept of the X-force controller for BVI noise reduction, and investigates its effectiveness on an S-70 helicopter. The analysis showed that further BVI noise reductions were achievable by controlling the fuselage pitching moment. Reductions in excess of 6 dB of the peak BVI noise radiated towards the ground were demonstrated by compounding the effect of airframe drag and pitching moment simultaneously.

Noise Reduction↗

Decoupling Power Quality Issues in Grid-Microgrid Network Using Microgrid Building Blocks

Microgrids are evolving as promising options to enhance reliability of the connected transmission and distribution systems. Traditional design and deployment of microgrids require significant engineering analysis. However, Microgrid Building Blocks (MBB), consisting of modular blocks that integrate seamlessly to form effective microgrids, are promising technologies to enable faster and broader adoption of microgrids. Back-to-Back converter placed at the point of common coupling of microgrid is an integral part of MBB. This paper presents applications of MBB to decouple power quality issues in grid-microgrid network serving power quality sensitive critical loads such as data centers, new grid-edge technologies such as vehicle-to-grid generation, and emergency condition loads such as electric vehicle charging loads during evacuation prior disaster events. Simulation results show that MBB effectively decouple the power quality issues across networks and allow network with low power quality to transfer high-power quality power to connected networks during emergency conditions.

Acharya, Samrat S. [BATTELLE (PACIFIC NW LAB)]↗

Co-Simulation Meets AI: MCP-Driven Power System Analysis

GridGPT, a fine-tuned Generative AI model is designed for on-premise use in grid control rooms. This presentation will demonstrate how eGridGPT can seamlessly integrate with control room solutions to offer operators, engineers, and corporate users enhanced guidance and decision support. It is to show how this innovative AI solution can improve state estimation, boost variable energy forecasting, and optimize grid operations. By leveraging eGridGPT's unique features, audience will learn to unlock new levels of automation, predictive analytics, and reliability within their power systems, ultimately leading to reduced downtime and improved operational efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrating aerodynamic surface modeling for computational fluid dynamics with computer aided structural analysis, design, and manufacturing

This presentation will discuss the development of a NASA Geometry Exchange Specification for transferring aerodynamic surface geometry between LeRC systems and grid generation software used for computational fluid dynamics research. The proposed specification is based on a subset of the Initial Graphics Exchange Specification (IGES). The presentation will include discussion of how the NASA-IGES standard will accommodate improved computer aided design inspection methods and reverse engineering techniques currently being developed. The presentation is in viewgraph format.

Thorp, Scott A.↗

An Analysis of Grid Operator Survey Responses: Inexperience, Workload and Fatigue in the Control Room

Although a wide array of tools and technologies have been developed over the last decade to support power grid operators, deployment of these tools has been less successful. One reason for unsuccessful deployment may be an inadequate understanding of the factors that contribute to operator error in the control room. An analysis of operators’ current vulnerabilities may provide the baseline understanding needed to inform new technology integration. In an attempt to learn more about these vulnerabilities and their perceived impact on human error we collected and analyzed survey data from 20 electric grid control room operators. We asked survey respondents to consider the various operator, technology and interaction vulnerabilities that may arise during work in the control room and record their attitudes and experiences toward each. Results suggest operator inexperience, high mental workload and fatigue are the most common vulnerabilities experienced during a shift. Survey results were analyzed to explore these vulnerabilities in greater depth.

Inexperience, Workload, Fatigue↗

Multi-Timescale Integrated Dynamics and Scheduling for Solar (MIDAS-Solar) (Final Technical Report)

Solar photovoltaic (PV) installations have experienced unprecedented growth in the United States. PV will become not only an energy producer but also a necessary provider of ancillary services at multiple timescales. Conventional methods to simulate power systems operations - such as long-term production simulation (which typically considers schedules from hours to minutes by using an optimization framework) and short-term transient studies (which simulate dynamics from seconds to sub-seconds using state variables and differential equations) - are not sufficient for studying the multiple-timescale variation of solar generation and its impact on system reliability. Long-term system economics and short-term system dynamics are highly coupled, particularly when the penetration level of renewable generation is extremely high, because the uncertainty and variability of solar generation will impact both power system steady-state and dynamic performance. This project helps meet and exceed the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Solar Energy Technologies Office goal of systems integration by directly addressing this stability and reliability challenge for power grid planning and operation. We have developed a temporally comprehensive, closed-loop simulation model, named Multi-timescale Integrated Dynamics and Scheduling (MIDAS), that seamlessly simulates power system operations from economic scheduling (day-ahead to hours) to dynamic response analysis (seconds to sub-seconds). For schedules with very high levels of inverter-based resources (IBRs), up to and including 100%, the stability of grid controls has been evaluated through electromagnetic transient (EMT) simulations and power-hardware-in-the-loop (PHIL) simulations of key transient events at key schedule points. Specifically, MIDAS provides: 1) a closed-loop simulation framework for simulating timescales from economic scheduling to dynamic stability analysis; 2) machine learning-based stability assessment; 3) EMT modeling and analysis for large-scale power systems; 4) MIDAS PHIL test bed. We worked with Hawaii Electric Companies to apply the MIDAS study framework to a Maui grid study. The entire island's transmission system was modeled in detail - from a yearly scheduling model, to a second-level frequency dynamic model, down to a sub-second-scale EMT model to address critical stability issues. The project demonstrated how MIDAS can help system planners and operators assess system reliability and stability while the power grid is marching toward a high-renewable, high-IBR future. In this Maui grid study, we found that 100% instantaneous IBR operation is achievable in EMT simulation and PHIL testing, and grid planners and operators might need new analysis/simulation tools to assess grid reliability and stability in the scheduling stage. MIDAS will bring Maui and other systems closer to 100% clean and stable energy futures. (In this study, we examined transient stability. Other topics necessary for 100% IBR operation, such as protection and resource adequacy, were not examined.)

100% Renewables↗

Examination of the Extreme Cold Weather Event Affecting the Power System in Texas - February 2021 [Slides]

This presentation examines the extreme cold weather event that affected the power system in Texas in February 2021. The Texas load-shedding events were caused by a combination of record-high demand and cold weather issues that reduced the output from all types of generation. While some wind turbines were shutting down due to cold temperatures and icing and a lack of cold-weather packages, hourly wind output was accurately predicted. Extreme weather events historically drive grid reliability. Additional examination of more extreme events is needed to understand their impacts on the power system. As a national lab, NREL has the capabilities and facilities to help the industry address these types of challenges. NREL also has significant simulation and analysis capabilities (such as NAERM) that can help understand the impacts of extreme events. NREL also developed the Advanced Research on Integrated Energy Systems (ARIES) Research Platform, which enables evaluation of technologies that smooth grid operations during events like this.

17 WIND ENERGY↗

Scalability analysis of heavy-duty gas turbines using data-driven machine learning

With the increasing integration of variable renewable energy sources into power systems, the role of flexible power generation technologies like gas turbines (GT) in rapid grid balancing remains crucial. This sustained importance underscores the need for scaled and precise modeling of GT to ensure effective integration within evolving energy frameworks. While physics-driven GT models integrate thermodynamics, fluid dynamics, and combustion principles, they often rely on approximate mathematical representations to accommodate scaling that may not capture the actual complex dynamics for GTs and inertial effects associated to GTs with different ratings. In this study, a data-driven model is proposed using machine learning (ML) techniques to conduct GT scalability analysis and performance evaluation with high accuracy. The ML model, trained on data from various operating conditions and performance parameters, aims to uncover intricate relationships and patterns, resembling GT characteristics at different scales (ratings). The model is developed to capture complex system interaction and to adapt to changing operational scenarios at different capacities, providing valuable insights of power system dynamics. In this study, the real-time digital simulator platform was employed to generate training data for the ML model and assess its dynamic characteristics. The ultimate objective was to develop a detailed modeling framework based on governing equations and data-driven ML capable of predicting key performance indicators, in thermal systems such as GTs, including power output, speed, fuel consumption, and exhaust temperature under diverse operating conditions at different scales. The developed ML framework demonstrated high accuracy, with mean relative errors for GT power prediction, reference speed, exhaust temperature, and compressor pressure ratio (CPR) parameters consistently below 0.1% across typical load fluctuation scenarios. Maximum deviations were limited to approximately 0.5 K for exhaust temperature and 0.009 for CPR, underscoring the model’s ability to replicating dynamic GT behavior with high precision. The adaptability of the ML model enables its application across diverse operational conditions and its extension to other thermal systems. By leveraging advanced ML techniques, this study presents a robust and scalable modeling framework that enhances GT simulation precision, facilitating improved integration into evolving power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Variational objective analyses for cyclone studies

The basic analysis equations, i.e., the two horizontal momentum equations, the hydrostatic equation, and the integrated continuity equation were derived for the nonlinear vertical coordinate, nondimensionalized, and expressed in finite differences on a staggered grid. Special care was taken to transform the hydrostatic equation and the pressure gradient terms of the horizontal momentum equations to nearly eliminate truncation error over steeply sloping terrain. This formulation also eliminated explicit reference to orographically induced variations in the thermodynamic variables so that the variational adjustments are on the scale of the meteorological perturbations. The analysis equations were subjected to the Euler-Lagrange operations as expressed for finite differences and an additional set of five partial differential equations was derived, bringing to nine the number of equations in Model I. Higher order terms, terms containing observed quantities, and terms containing none of the variables to be adjusted were grouped into forcing functions and the equations were solved for the zero order terms. Zero order variables were eliminated between these equations and there resulted two diagnostic equations which take the form of general linear second order partial differential equations with nonconstant coefficients.

Achtemeier, G. L.↗

Three-dimensional time-marching aeroelastic analyses using an unstructured-grid Euler method

The modifications to a 3D implicit, upwind, unstructured-grid Euler code for aeroelastic analysis of complete aircraft configurations described involve the addition of structural equations of motion for their simultaneous time integration with the governing flow equations. A detailed description of the time-marching aeroelastic procedure and comparisons with experimental data are presented, to provide an assessment of capabilities. Flutter results are shown for an isolated 45-deg sweptback wing and an SST with a fuselage, clipped delta wing, and two identical rearward-mounted nacelles. Comparisons between computed and experimental flutter characteristics show good agreement.

Rausch, Russ D.↗