Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “geometrics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Geometric symmetries in superfluid vortex dynamics

Dynamics of quantized vortex lines in a superfluid feature symmetries associated with the geometric character of the complex-valued field, w(z)=x(z)+iy(z), describing the instant shape of the line. Along with a natural set of Noether's constants of motion, which - apart from their rather specific expressions in terms of w(z) - are nothing but components of the total linear and angular momenta of the fluid, the geometric symmetry brings about crucial consequences for kinetics of distortion waves on the vortex lines, the Kelvin waves. It is the geometric symmetry that renders Kelvin-wave cascade local in the wave-number space. Similar considerations apply to other systems with purely geometric degrees of freedom.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Emergent geometric frustration of artificial magnetic skyrmion crystals

Magnetic skyrmions have been receiving growing attention as potential information storage and magnetic logic devices since an increasing number of materials have been identified that support skyrmion phases. Explorations of artificial frustrated systems have led to new insights into controlling and engineering new emergent frustration phenomena in frustrated and disordered systems. Here, we propose a skyrmion spin ice, giving a unifying framework for the study of geometric frustration of skyrmion crystals (SCs) in a nonfrustrated artificial geometrical lattice as a consequence of the structural confinement of skyrmions in magnetic potential wells. The emergent ice rules from the geometrically frustrated SCs highlight a novel phenomenon in this skyrmion system: emergent geometrical frustration. We demonstrate how SC topology transitions between a nonfrustrated periodic configuration and a frustrated icelike ordering can also be realized reversibly. The proposed artificial frustrated skyrmion systems can be annealed into different ice phases with an applied current-induced spin-transfer torque, including a long-range ordered ice rule obeying ground state, as-relaxed random state, biased state, and monopole state. In conclusion, the spin-torque reconfigurability of the artificial skyrmion ice states, difficult to achieve in other artificial spin ice systems, is compatible with standard spintronic device fabrication technology, which makes the semiconductor industrial integration straightforward.

36 MATERIALS SCIENCE↗

Linear point and sound horizon as purely geometric standard rulers

The baryon acoustic oscillations feature (BAO) imprinted in the clustering correlation function is known to furnish us cosmic distance determinations that are independent of the cosmological-background model and the primordial perturbation parameters. These measurements can be accomplished rigorously by means of the purely geometric BAO methods. To date two different purely geometric BAO approaches have been proposed. The first exploits the linear-point standard ruler. The second, called correlation-function model-fitting, exploits the sound-horizon standard ruler. A key difference between them is that, when estimated from clustering data, the linear point makes use of a cosmological-model-independent procedure to extract the ratio of the ruler to the cosmic distance, while the correlation-function model-fitting relies on a phenomenological cosmological model for the correlation function. Nevertheless the two rulers need to be precisely defined independently of any specific observable (e.g., the BAO). We define the linear point and sound horizon and we fully characterize and compare the two rulers’ cosmological-parameter dependence. We find that they are both geometrical (i.e., independent of the primordial cosmological parameters) within the required accuracy, and that they have the same parameter dependence for a wide range of parameter values. We estimate the rulers’ best-fit values and errors, given the cosmological constraints obtained by the Planck Satellite team from their measurements of the cosmic microwave background temperature and polarization anisotropies. We do this for three different cosmological models encompassed by the purely geometric BAO methods. In each case we find that the relative errors of the two rulers coincide and they are insensitive to the assumed cosmological model. Interestingly both the linear point and the sound horizon shift by 0.5σ when we do not fix the spatial geometry to be flat in Λ CDM. Finally, this points toward a sensitivity of the rulers to different cosmological models when they are estimated from the cosmic microwave background.

79 ASTRONOMY AND ASTROPHYSICS↗

Density fields and halo mass functions in the geometrical adhesion toy model

In dimension 2 and above, the Burgers dynamics, the so-called 'adhesion model' in cosmology, can actually give rise to several dynamics in the inviscid limit. We investigate here the statistical properties of the density field when it is defined by a 'geometrical model' associated with this Burgers velocity field and where the matter distribution is fully determined, at each time step, by geometrical constructions. Our investigations are based on a set of numerical experiments that make use of an improved algorithm, for which the geometrical constructions are efficient and robust. In this work we focus on Gaussian initial conditions with power-law power spectra of slope n in the range -3<n<1, where a self-similar evolution develops, and we compute the behavior of power spectra, density probability distributions and mass functions. As expected for such dynamics, the density power spectra show universal high-k tails that are governed by the formation of pointlike masses. The two other statistical indicators however show the same qualitative properties as those observed for 3D gravitational clustering. In particular, the mass functions obey a Press-Schechter like scaling up to a very good accuracy in 1D, and to a lesser extent in 2D. Our results suggest that the 'geometrical adhesion model', whose solution is fully known at all times, provides a precious tool to understand some of the statistical constructions frequently used to study the development of mass halos in gravitational clustering.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pareto Optimal and Dual-Objective Geometric and Structural Design of an Underwater Kite for Closed-Loop Flight Performance

This paper presents the formulation and results for a control-aware optimization of the combined geometric and structural design of an energy-harvesting underwater kite. Because kite-based energy-harvesting systems, both airborne and underwater, possess strong coupling between closed-loop flight control, geometric design, and structural design, consideration of all three facets of the design within a single codesign framework is highly desirable. However, while prior literature has addressed one or two attributes of the design at a time, this work constitutes the first comprehensive effort aimed at addressing all three. In particular, focusing on the goals of power maximization and mass minimization, we present a codesign formulation that fuses a geometric optimization tool, structural optimization tool, and closed-loop flight efficiency map. The resulting integrated codesign tool is used to address two mathematical optimization formulations that exhibit subtle differences: a Pareto optimal formulation and a dual-objective formulation that focuses on a weighted power-to-mass ratio as the techno-economic metric of merit. Further, based on the resulting geometric and structural designs, using a mediumfidelity closed-loop simulation tool, the proposed formulation is shown to achieve more than three times the powerto-mass ratio of a previously published, unoptimized benchmark design.

42 ENGINEERING↗

A simple geometric algorithm to predict optimal starting gantry angles using equiangular-spaced beams for intensity modulated radiation therapy of prostate cancer

A fast, geometric beam angle optimization (BAO) algorithm for clinical intensity-modulated radiation therapy (IMRT) was implemented on ten localized prostate cancer patients on the Radiation Therapy Oncology Group (RTOG) 0126 protocol. The BAO algorithm computed the beam intersection volume (BIV) within the rectum and bladder using five and seven equiangular-spaced beams as a function of starting gantry angle for comparison to the V 75 Gy and V 70 Gy. A mathematical theory was presented to explain the correlation of BIV with dose and dose-volume metrics. The class solution 'W' pattern in the rectal V 75 Gy and V 70 Gy as a function of starting gantry angle using five equiangular-spaced beams (with two separate minima centered near 20 deg. and 50 deg. ) was reproduced by the 5 BIV within the rectum. A strong correlation was found between the rectal 5 BIV and the rectal V 75 Gy and V 70 Gy as a function of starting gantry angle. The BAO algorithm predicted the location of the two dosimetric minima in rectal V 75 Gy and V 70 Gy (optimal starting gantry angles) to within 5 deg. . It was demonstrated that the BIV geometric variations for seven equiangular-spaced beams were too small to translate into a strong dosimetric effect in the rectal V 75 Gy and V 70 Gy. The relatively flat distribution with starting gantry angle of the bladder V 75 Gy and V 70 Gy was reproduced by the bladder five and seven BIV for each patient. A geometric BAO method based on BIV has the advantage over dosimetric BAO methods of simplicity and rapid computation time. This algorithm can be used as a standalone optimization method or act as a rapid calculation filter to reduce the search space for a dosimetric BAO method. Given the clinically infeasible computation times of many dosimetric beam orientation optimization algorithms, this robust geometric BIV algorithm has the potential to facilitate beam angle selection for prostate IMRT in clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Geometric characterization of multi-axis multi-pinhole SPECT

A geometric model and calibration process are developed for single photon emission computed tomography (SPECT) imaging with multiple pinholes and multiple mechanical axes. Unlike the typical situation where pinhole collimators are mounted directly to rotating gamma ray detectors, this geometric model allows for independent rotation of the detectors and pinholes, for the case where the pinhole collimator is physically detached from the detectors. This geometric model is applied to a prototype small animal SPECT device with a total of 22 pinholes and which uses dual clinical SPECT detectors. All free parameters in the model are estimated from a calibration scan of point sources and without the need for a precision point source phantom. For a full calibration of this device, a scan of four point sources with 360 deg. rotation is suitable for estimating all 95 free parameters of the geometric model. After a full calibration, a rapid calibration scan of two point sources with 180 deg. rotation is suitable for estimating the subset of 22 parameters associated with repositioning the collimation device relative to the detectors. The high accuracy of the calibration process is validated experimentally. Residual differences between predicted and measured coordinates are normally distributed with 0.8 mm full width at half maximum and are estimated to contribute 0.12 mm root mean square to the reconstructed spatial resolution. Since this error is small compared to other contributions arising from the pinhole diameter and the detector, the accuracy of the calibration is sufficient for high resolution small animal SPECT imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of a QA phantom and automated analysis tool for geometric quality assurance of on-board MV and kV x-ray imaging systems

The medical linear accelerator (linac) integrated with a kilovoltage (kV) flat-panel imager has been emerging as an important piece of equipment for image-guided radiation therapy. Due to the sagging of the linac head and the flexing of the robotic arms that mount the x-ray tube and flat-panel detector, geometric nonidealities generally exist in the imaging geometry no matter whether it is for the two-dimensional projection image or three-dimensional cone-beam computed tomography. Normally, the geometric parameters are established during the commissioning and incorporated in correction software in respective image formation or reconstruction. A prudent use of an on-board imaging system necessitates a routine surveillance of the geometric accuracy of the system like the position of the x-ray source, imager position and orientation, isocenter, rotation trajectory, and source-to-imager distance. Here we describe a purposely built phantom and a data analysis software for monitoring these important parameters of the system in an efficient and automated way. The developed tool works equally well for the megavoltage (MV) electronic portal imaging device and hence allows us to measure the coincidence of the isocenters of the MV and kV beams of the linac. This QA tool can detect an angular uncertainty of 0.1 deg. of the x-ray source. For spatial uncertainties, such as the source position, the imager position, or the kV/MV isocenter misalignment, the demonstrated accuracy of this tool was better than 1.6 mm. The developed tool provides us with a simple, robust, and objective way to probe and monitor the geometric status of an imaging system in a fully automatic process and facilitate routine QA workflow in a clinic.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Correction of MRI-induced geometric distortions in whole-body small animal PET-MRI

Purpose: The fusion of positron emission tomography (PET) and magnetic resonance imaging (MRI) data can be a challenging task in whole-body PET-MRI. The quality of the registration between these two modalities in large field-of-views (FOV) is often degraded by geometric distortions of the MRI data. The distortions at the edges of large FOVs mainly originate from MRI gradient nonlinearities. This work describes a method to measure and correct for these kind of geometric distortions in small animal MRI scanners to improve the registration accuracy of PET and MRI data. Methods: The authors have developed a geometric phantom which allows the measurement of geometric distortions in all spatial axes via control points. These control points are detected semiautomatically in both PET and MRI data with a subpixel accuracy. The spatial transformation between PET and MRI data is determined with these control points via 3D thin-plate splines (3D TPS). The transformation derived from the 3D TPS is finally applied to real MRI mouse data, which were acquired with the same scan parameters used in the phantom data acquisitions. Additionally, the influence of the phantom material on the homogeneity of the magnetic field is determined via field mapping. Results: The spatial shift according to the magnetic field homogeneity caused by the phantom material was determined to a mean of 0.1 mm. The results of the correction show that distortion with a maximum error of 4 mm could be reduced to less than 1 mm with the proposed correction method. Furthermore, the control point-based registration of PET and MRI data showed improved congruence after correction. Conclusions: The developed phantom has been shown to have no considerable negative effect on the homogeneity of the magnetic field. The proposed method yields an appropriate correction of the measured MRI distortion and is able to improve the PET and MRI registration. Furthermore, the method is applicable to whole-body small animal imaging routines including different standard MRI sequences.

60 APPLIED LIFE SCIENCES↗

SU-E-J-209: Geometric Distortion at 3T in a Commercial 4D MRI-Compatible Phantom

Purpose: There are very few commercial 4D phantoms that are marketed as MRI compatible. We are evaluating one such commercial phantom, made to be used with an MRI-Linear accelerator. The focus of this work is to characterize the geometric distortions produced in this phantom at 3T using 3 clinical MR pulse sequences. Methods: The CIRS MRI-Linac Dynamic Phantom (CIRSTM) under investigation in this study consists of a softwaredriven moving tumour volume within a thorax phantom body and enables dose accumulation by placing a dosimeter within the tumour volume. Our initial investigation is to evaluate the phantom in static mode prior to examining its 4D capability. The water-filled thorax phantom was scanned using a wide-bore Philips 3T Achieva MRI scanner employing a Thoracic xl coil and clinical 2D T1W FFE, 2D T1W TSE and 3D T1W TFE pulse sequences. Each of the MR image sets was rigidly fused with a reference CT image of the phantom employing a rigid registration with 6 degrees of freedom. Geometric distortions between the MR and CT image sets were measured in 3 dimensions at selected points along the periphery of the distortion grid embedded within the phantom body (11.5, 7.5 and 3 cm laterally, ant/post and sup/inf of magnetic isocenter respectively). Results: The maximal measured geometric distortions between the MR and reference CT points of interest were 0.9, 1.8 and 1.3 mm in the lateral, anteriorposterior and cranio-caudal directions, respectively. For all 3 spatial dimensions, the maximal distortions occurred for the FFE pulse sequence. Maximal distortions for the 2D FFE, 2D TSE and 3D TFE sequences were 1, 0.7 and 1.8 mm, respectively. Conclusion: Our initial static investigation of this phantom shows minimal geometric distortions at 3T along the periphery of the embedded grid. CIRS has provided us with a phantom at no charge for evaluation at 3 Tesla.

60 APPLIED LIFE SCIENCES↗

SU-F-J-74: High Z Geometric Integrity and Beam Hardening Artifact Assessment Using a Retrospective Metal Artifact Reduction (MAR) Reconstruction Algorithm

Purpose: To test the efficacy of a retrospective metal artifact reduction (MAR) reconstruction algorithm for a commercial computed tomography (CT) scanner for radiation therapy purposes. Methods: High Z geometric integrity and artifact reduction analysis was performed with three phantoms using General Electric’s (GE) Discovery CT. The three phantoms included: a Computerized Imaging Reference Systems (CIRS) electron density phantom (Model 062) with a 6.5 mm diameter titanium rod insert, a custom spine phantom using Synthes Spine hardware submerged in water, and a dental phantom with various high Z fillings submerged in water. Each phantom was reconstructed using MAR and compared against the original scan. Furthermore, each scenario was tested using standard and extended Hounsfield Unit (HU) ranges. High Z geometric integrity was performed using the CIRS phantom, while the artifact reduction was performed using all three phantoms. Results: Geometric integrity of the 6.5 mm diameter rod was slightly overestimated for non-MAR scans for both standard and extended HU. With MAR reconstruction, the rod was underestimated for both standard and extended HU. For artifact reduction, the mean and standard deviation was compared in a volume of interest (VOI) in the surrounding material (water and water equivalent material, ∼0HU). Overall, the mean value of the VOI was closer to 0 HU for the MAR reconstruction compared to the non-MAR scan for most phantoms. Additionally, the standard deviations for all phantoms were greatly reduced using MAR reconstruction. Conclusion: GE’s MAR reconstruction algorithm improves image quality with the presence of high Z material with minimal degradation of its geometric integrity. High Z delineation can be carried out with proper contouring techniques. The effects of beam hardening artifacts are greatly reduced with MAR reconstruction. Tissue corrections due to these artifacts can be eliminated for simple high Z geometries and greatly reduced for more complex geometries.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP2-12: Quantification of 3D Geometric Distortion for 1.5T and 3T MRI Scanners Used for Radiation Therapy

Purpose: To quantify the magnitude of geometric distortion for MRI scanners and provide recommendations for MRI imaging for radiation therapy Methods: A novel phantom, QUASAR MRID3D [Modus Medical Devices Inc.], was scanned to evaluate the level of 3D geometric distortion present in five MRI scanners used for radiation therapy in our department. The phantom was scanned using the body coil with 1mm image slice thickness to acquire 3D images of the phantom body. The phantom was aligned to its geometric center for each scan, and the field of view was set to visualize the entire phantom. The dependence of distortion magnitude with distance from imaging isocenter and with magnetic field strength (1.5T and 3T) was investigated. Additionally, the characteristics of distortion for Siemens and GE machines were compared. The image distortion for each scanner was quantified in terms of mean, standard deviation (STD), maximum distortion, and skewness. Results: The 3T and 1.5T scans show a similar absolute distortion with a mean of 1.38mm (0.33mm STD) for 3T and 1.39mm (0.34mm STD) for 1.5T for a 100mm radius distance from isocenter. Some machines can have a distortion larger than 10mm at a distance of 200mm from the isocenter. The distortions are presented with plots of the x, y, and z directional components. Conclusion: The results indicate that quantification of MRI image distortion is crucial in radiation oncology for target and organ delineation and treatment planning. The magnitude of geometric distortion determines the margin needed for target contouring which is usually neglected in treatment planning process, especially for SRS/SBRT treatments. Understanding the 3D distribution of the MRI image distortion will improve the accuracy of target delineation and, hence, treatment efficacy. MRI imaging with proper patient alignment to the isocenter is vital to reducing the effects of MRI distortion in treatment planning.

60 APPLIED LIFE SCIENCES↗

Disentangling the size-dependent geometric and electronic effects of palladium nanocatalysts beyond selectivity

The prominent size effect of metal nanoparticles shapes decisively nanocatalysis, but entanglement of the corresponding geometric and electronic effects prevents exploiting their distinct functionalities. In this work, we demonstrate that in palladium (Pd)–catalyzed aerobic oxidation of benzyl alcohol, the geometric and electronic effects interplay and compete so intensively that both activity and selectivity showed in volcano trends on the Pd particle size unprecedentedly. By developing a strategy of site-selective blocking via atomic layer deposition along with first principles calculations, we disentangle these two effects and unveil that the geometric effect dominates the right side of the volcano with larger-size Pd particles, whereas the electronic effect directs the left of the volcano with smaller-size Pd particles substantially. Selective blocking of the low-coordination sites prevents formation of the undesired by-product beyond the volcano relationship, achieving a remarkable benzaldehyde selectivity and activity at the same time for 4-nm Pd. Disentangling the geometric and electronic effects of metal nanoparticles opens a new dimension for rational design of catalysts.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The mathematical and geometrical structure of the spacetime and the concept of unification, matter and energy

Geometrical analysis of a new type of Unified Field Theoretical models follow the guidelines of previous works of the authors is presented. These new unified theoretical models are characterized by an underlying hypercomplex structure, zero non-metricity and the geometrical action is determined fundamentally by the curvature provenient of the breaking of symmetry of a group manifold in higher dimensions. This mechanism of Cartan-MacDowell-Mansouri type, permits us to construct geometrical actions of determinantal type leading a non topological physical Lagrangian due the splitting of a reductive geometry. Our goal is to take advantage of the geometrical and topological properties of this theory in order to determine the minimal group structure of the resultant spacetime Manifold able to support a fermionic structure. From this fact, the relation between antisymmetric torsion and Dirac structure of the spacetime is determined and the existence of an important contribution of the torsion to the giromagnetic factor of the fermions, shown. Also we resume and analyze previous cosmological solutions in this new UFT where, as in our work [Class. Quantum Grav. 22 (2005) 4987–5004] for the non abelian Born-Infeld model, the Hosoya and Ogura ansatz is introduced for the important cases of tratorial, totally antisymmetric and general torsion fields. In the case of spacetimes with torsion the real meaning of the spin-frame alignment is find and the question of the minimal coupling is discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Geometric Phase Of The Faraday Rotation Of Electromagnetic Waves In Magnetized Plasma

The geometric phase of circularly polarized electromagnetic waves in nonuniform magnetized plasmas is studied theoretically. The variation of the propagation direction of circularly polarized waves results in a geometric phase, which also contributes to the Faraday rotation, in addition to the standard dynamical phase. The origin and properties of the geometric phase is investigated. The in uence of the geometric phase to plasma diagnostics using Faraday rotation is also discussed as an application of the theory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Early Career Award: Decoupling the Electronic and Geometric Parameters of Metal Nanocatalysts

Central in many industrial processes (e.g., petroleum refining) and the realization of new energy platforms (e.g., fuel cells and biomass conversion) is heterogeneous catalysis. The performance of a catalyst is governed by interplay between electronic and geometric factors, but controlling these parameters to achieve efficient catalysis remains a grand challenge. The overall goal of this project was to decouple the electronic and geometric parameters of nanoscale metal catalysts for independent manipulation through the design and use of new architecturally controlled bimetallic nanocrystals. Specifically, shape-controlled core@shell nanocrystals were studied as catalysts. The binary composition of these structures provided a means of electronic control while the shape of the nanocrystals provided geometric control. Through a series of experiments with nanocrystals of different shapes and bimetallic compositions, the electronic and geometric parameters of such metal nanocatalysts were effectively decoupled for independent manipulation of catalyst performance. These concepts were applied toward new nanocatalysts for semihydrogenation, formic acid electrooxidation and for the oxygen reduction reaction. Ultimately, with the development of new synthetic strategies toward bimetallic nanocrystals, this research has advanced the design and synthesis of bimetallic nanocrystals as catalysts for diverse chemical transformations.

36 MATERIALS SCIENCE↗

AI-Assisted Conceptual Development of a Pre-Geometric Cosmological Model - An Exercise in AI-Assisted Conceptual Framework Generation, Paper II: Local Geometry and Metric Structure

This paper develops the geometric sector of the replication-driven cosmogenesis framework introduced in Paper I. Starting from a pre-geometric spectral substrate and a minimal set of replication axioms, we show how coherent self-replicating units generate a spatial adjacency graph whose continuum limit acquires an effective Riemannian structure. The replication dynamics determines a characteristic correlation length that seeds the local metric, while overlap relations among coherent units produce an isotropic neighborhood geometry with an emergent dimensionality $d_{\rm eff}\simeq 3$ across a broad range of replication factors. As replication slows and causal order stabilizes, a limiting signal speed $c_\ast$ appears, providing the basis for the Lorentzian structure of spacetime without assuming a pre-existing light cone. We derive conditions under which the adjacency graph converges to a smooth three-dimensional manifold, describe the transition from Euclidean to Lorentzian propagation, and identify geometric invariants controlled by the replication parameters. This work establishes the geometric and causal layer of the replication cosmogenesis program, bridging the spectral axioms of Paper I to the cosmological dynamics explored in Paper III.

79 ASTRONOMY AND ASTROPHYSICS↗

Geometric similitude of lunar and terrestrial craters.

Application of an elementary technique of dimensional analysis, that of testing for geometric similitude, suggests an impact genesis for most lunar craters. Geometrically similar phenomena fulfill four requirements: (1) log-log plots of paired descriptive variables are linear, (2) slopes of these plots equal ratios of the dimensions of the two variables, (3) intercepts of the plots are the same and (4) phenomena belong to the same general taxonomic group. Five topographic criteria are used to test lunar and terrestrial craters for geometric similitude: the variation of rim diameter with (1) interior depth, (2) exterior rim height, (3) exterior rim width and (4) rim crest circularity, and (5) variation of exterior rim height with crater depth. By all criteria, fresh bowl-shaped lunar craters between 10 m and 20 km in diameter are geometrically similar to fresh terrestrial meteorite craters and craters produced by chemical and nuclear explosives at shallow depths of burial. Most lunar craters exceeding 10-20 km in diameter fulfill only the last three criteria of similitude.

Pike, R. J.↗