Technical Note: High temporal resolution characterization of gating response time

Purpose: Low temporal latency between a gating ON/OFF signal and the LINAC beam ON/OFF during respiratory gating is critical for patient safety. Here the authors describe a novel method to precisely measure gating lag times at high temporal resolutions. Methods: A respiratory gating simulator with an oscillating platform was modified to include a linear potentiometer for position measurement. A photon diode was placed at linear accelerator isocenter for beam output measurement. The output signals of the potentiometer and diode were recorded simultaneously at 2500 Hz with an analog to digital converter for four different commercial respiratory gating systems. The ON and OFF of the beam signal were located and compared to the expected gating window for both phase and position based gating and the temporal lag times extracted. Results: For phase based gating, a real-time position management (RPM) infrared marker tracking system with a single camera and a RPM system with a stereoscopic camera were measured to have mean gate ON/OFF lag times of 98/90 and 86/44 ms, respectively. For position based gating, an AlignRT 3D surface system and a Calypso magnetic fiducial tracking system were measured to have mean gate ON/OFF lag times of 356/529 and 209/60 ms, respectively. Conclusions: Temporal resolution of the method was high enough to allow characterization of individual gate cycles and was primary limited by the sampling speed of the data recording device. Significant variation of mean gate ON/OFF lag time was found between different gating systems. For certain gating devices, individual gating cycle lag times can vary significantly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-514: Evaluation of the Accuracy of Free-Breathing and Deep Inspiration Breath-Hold Gated Beam Delivery Using An Elekta Linac

Purpose: In this study, we evaluated the performance of an Elekta linac in the delivery of gated radiotherapy. We examined whether the use of either a short gating window or a long beam hold impacts the accuracy of the delivery Methods: The performance of an Elekta linac in the delivery of gated radiotherapy was assessed using a 20cmX 20cm open field with the radiation delivered using a range of beam-on and beam-off time periods. Two SBRT plans were used to examine the accuracy of gated beam delivery for clinical treatment plans. For the SBRT cases, tests were performed for both free-breathing based gating and for gated delivery with a simulated breath-hold. A MatriXX 2D ion chamber array was used for data collection, and the gating accuracy was evaluated using gamma score. Results: For the 20cmX20cm open field, the gated beam delivery agreed closely with the non-gated delivery results. Discrepancies in the agreement, however, began to appear with a 5-to-1 ratio of the beam-off to beam-on. For these tight gating windows, each beam-on segment delivered a small number of monitor units. This finding was confirmed with dose distribution analysis from the delivery of the two VMAT plans where the gamma score(±1%,2%/1mm) showed passing rates in the range of 95% to 100% for gating windows of 25%, 38%, 50%, 63%, 75%, and 83%. Using a simulated sinusoidal breathing signal with a 4 second period, the gamma score of freebreathing gating and breath-hold gating deliveries were measured in the range of 95.7% to 100%. Conclusion: The results demonstrate that Elekta linacs can be used to accurately deliver respiratory gated treatments for both free-breathing and breath-hold patients. The accuracy of beams delivered in a gated delivery mode at low small MU proved higher than similar deliveries performed in a non-gated (manually interrupted) fashion.

60 APPLIED LIFE SCIENCES↗

Accuracy and Consistency of Respiratory Gating in Abdominal Cancer Patients

Purpose: To evaluate respiratory gating accuracy and intrafractional consistency for abdominal cancer patients treated with respiratory gated treatment on a regular linear accelerator system. Methods and Materials: Twelve abdominal patients implanted with fiducials were treated with amplitude-based respiratory-gated radiation therapy. On the basis of daily orthogonal fluoroscopy, the operator readjusted the couch position and gating window such that the fiducial was within a setup margin (fiducial-planning target volume [f-PTV]) when RPM indicated “beam-ON.” Fifty-five pre- and post-treatment fluoroscopic movie pairs with synchronized respiratory gating signal were recorded. Fiducial motion traces were extracted from the fluoroscopic movies using a template matching algorithm and correlated with f-PTV by registering the digitally reconstructed radiographs with the fluoroscopic movies. Treatment was determined to be “accurate” if 50% of the fiducial area stayed within f-PTV while beam-ON. For movie pairs that lost gating accuracy, a MATLAB program was used to assess whether the gating window was optimized, the external-internal correlation (EIC) changed, or the patient moved between movies. A series of safety margins from 0.5 mm to 3 mm was added to f-PTV for reassessing gating accuracy. Results: A decrease in gating accuracy was observed in 44% of movie pairs from daily fluoroscopic movies of 12 abdominal patients. Three main causes for inaccurate gating were identified as change of global EIC over time (∼43%), suboptimal gating setup (∼37%), and imperfect EIC within movie (∼13%). Conclusions: Inconsistent respiratory gating accuracy may occur within 1 treatment session even with a daily adjusted gating window. To improve or maintain gating accuracy during treatment, we suggest using at least a 2.5-mm safety margin to account for gating and setup uncertainties.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Geometric representations of braid and Yang–Baxter gates

Brick-wall circuits composed of the Yang–Baxter gates are integrable. It becomes an important tool to study the quantum many-body system out of equilibrium. To put the Yang–Baxter gate on quantum computers, it has to be decomposed into the native gates of quantum computers. It is favorable to apply the least number of native two-qubit gates to construct the Yang–Baxter gate. We study the geometric representations of all X-type braid gates and their corresponding Yang–Baxter gates via the Yang–Baxterization. We find that the braid and Yang–Baxter gates can only exist on certain edges and faces of the two-qubit tetrahedron. We identify the parameters by which the braid and Yang–Baxter gates are the Clifford gate, the matchgate, and the dual-unitary gate. The geometric representations provide the optimal decompositions of the braid and Yang–Baxter gates in terms of other two-qubit gates. We also find that the entangling powers of the Yang–Baxter gates are determined by the spectral parameters. Our results provide the necessary conditions to construct the braid and Yang–Baxter gates on quantum computers.

97 MATHEMATICS AND COMPUTING↗

SU-C-210-03: Impact of Breathing Irregularities On Gated Treatments

Purpose: To evaluate the effect of breathing irregularities on target location in gated treatments using amplitude and phase gating. Methods: 111 breathing patterns acquired using RPM system were categorized based on period and amplitude STD as regular (STD period ≤ 0.5 s, STD amplitude ≤ 1.5 mm), medium (0.5 s < STD period ≤ 1 s, 1.5 mm < STD amplitude ≤ 3 mm) and irregular (STD period > 1 s, STD amplitude > 3 mm). One pattern representative of the average defined population was selected per category and corresponding target motion reproduced using Quasar Respiratory Motion Phantom. Phantom in motion underwent 4D-CT scan with phase reconstruction. Gated window was defined at end of exhale and DRRs reconstructed in treatment planning at 40% (beam on) and 60% phase (beam off). Target location uncertainty was assessed by comparing gated kV triggered images continuously acquired at beam on/off on a True Beam 2.0 with corresponding DRRs. Results: Average target uncertainty with amplitude gating was in [0.4 – 1.9] mm range for the different scenarios with maximum STD of 1.2 mm for the irregular pattern. Average target uncertainty with phase gating was [1.1 – 2.2] mm for regular and medium patterns, while it increased to [3.6 – 9.6] mm for the irregular pattern. Live gated motion was stable with amplitude gating, while increasing with phase gating for the irregular pattern. Treatment duration range was [68 – 160] s with amplitude and [70 – 74] s with phase gating. Conclusion: Breathing irregularities were found to affect gated treatments only when using phase gating. For regular and medium patterns no significant difference was found between the two gating strategies. Amplitude gating ensured stable gated motion within the different patterns, thus reducing intra-fraction target location variability for the irregular pattern and resulting in longer treatment duration.

60 APPLIED LIFE SCIENCES↗

SU-E-J-169: The Dosimetric and Temporal Effects of Respiratory-Gated Radiation Therapy in Lung Cancer Patients

Purpose: To evaluate the dosimetric and temporal effects of high dose rate treatment mode for respiratory-gated radiation therapy in lung cancer patients. Methods: Treatment plans from five lung cancer patients (3 nongated (Group 1), 2 gated at 80EX-80IN (Group 2)) were retrospectively evaluated. The maximum tumor motions range from 6–12 mm. Using the same planning criteria, four new treatment plans, corresponding to four gating windows (20EX–20IN, 40EX–40IN, 60EX–60IN, and 80EX–80IN), were generated for each patient. Mean tumor dose (MTD), mean lung dose (MLD), and lung V20 were used to assess the dosimetric effects. A MATLAB algorithm was developed to compute treatment time by considering gantry rotation time, time to position collimator leaves, dose delivery time (scaled relative to the gating window), and communication overhead. Treatment delivery time for each plan was estimated using a 500 MU/min dose rate for the original plans and a 1500 MU/min dose rate for the gated plans. Results: Differences in MTD were less than 1Gy across plans for all five patients. MLD and lung V20 were on average reduced between −16.1% to −6.0% and −20.0% to −7.2%, respectively for non-gated plans when compared with the corresponding gated plans, and between − 5.8% to −4.2% and −7.0% to −5.4%, respectively for plans originally gated at 80EX–80IN when compared with the corresponding 20EX-20IN to 60EX– 60IN gated plans. Treatment delivery times of gated plans using high dose rate were reduced on average between −19.7% (−1.9min) to −27.2% (−2.7min) for originally non-gated plans and −15.6% (−0.9min) to −20.3% (−1.2min) for originally 80EX-80IN gated plans. Conclusion: Respiratory-gated radiation therapy in lung cancer patients can reduce lung toxicity, while maintaining tumor dose. Using a gated high-dose-rate treatment, delivery time comparable to non-gated normal-dose-rate treatment can be achieved. This research is supported by Siemens Medical Solutions USA, Inc.

60 APPLIED LIFE SCIENCES↗

Gate Quantum Capacitance Effects in Nanoscale Transistors

As the physical dimensions of a transistor gate continue to shrink to a few atoms, performance can be increasingly determined by the limited electronic density of states (DOS) in the gate and the gate quantum capacitance (C Q ). We demonstrate the impact of gate C Q and the dimensionality of the gate electrode on the performance of nanoscale transistors through analytical electrostatics modeling. For low-dimensional gates, the gate charge can limit the channel charge, and the transfer characteristics of the device become dependent on the gate DOS. Here, we experimentally observe for the first time, room-temperature gate quantization features in the transfer characteristics of single-walled carbon nanotube (CNT)-gated ultrathin silicon-on-insulator (SOI) channel transistors; features which can be attributed to the Van Hove singularities in the one-dimensional DOS of the CNT gate. In addition to being an important aspect of future transistor design, potential applications of this phenomenon include multilevel transistors with suitable transfer characteristics obtained via engineered gate DOS.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Comparison of spontaneous emission in trapped-ion multiqubit gates at high magnetic fields

Penning traps have been used for performing quantum simulations and sensing with hundreds of ions and provide a promising route toward scaling up trapped ion quantum platforms because of the ability to trap and control hundreds or thousands of ions in two- and three-dimensional crystals. In both Penning traps and the more common RF Paul traps, lasers are often used to drive multi-qubit entangling operations. A leading source of decoherence in these operations is off resonant spontaneous emission. While many trapped ion quantum computers or simulators utilize clock qubits, other systems, especially those with high magnetic fields such as Penning traps, rely on Zeeman qubits, which require a more complex calculation of this decoherence. We therefore examine theoretically the impacts of spontaneous emission on quantum gates performed with trapped-ion ground state Zeeman qubits in a high magnetic field. In particular, we consider two types of gates—light-shift ($\hat{σ}^z_i$ $\hat{σ}^z_j$) gates and Mølmer-Sørensen ($\hat{σ}^x_i$ $\hat{σ}^x_j$) gates—obtained with laser beams directed approximately perpendicular to the magnetic field (the quantization axis) and compare the decoherence errors in each. Within each gate type, we also compare different operating points with regards to the detunings, polarizations, and required intensity of the laser beams used to drive the gates. Here, we show that both gates can have similar performance at their optimal operating conditions at high magnetic fields and examine the experimental feasibility of various operating points. By examining the magnetic field dependence of each gate, we demonstrate that, when the P state fine structure splitting is large compared to the Zeeman splittings, the theoretical performance of the Mølmer-Sørensen gate is significantly better than that of the light-shift gate. Additionally, for the light-shift gate, we make an approximate comparison between the fidelities that can be achieved at high fields with the fidelities of state-of-the-art two-qubit trapped ion quantum gates. We show that, with regards to spontaneous emission, the achievable fidelity of the current NIST configuration is about an order of magnitude below that of the best low-field gates, but we also discuss several alternative configurations with potential error rates that are comparable with those for state-of-the art trapped ion gates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-J-184: Volumetric Indices to Aid Definition of Respiratory Gates with Particular Reference to Lung Stereotactic Body Radiotherapy (SBRT)

Purpose: Conventional definition of respiratory gates relies on tumor motion determination in limited planes. We are proposing a new method to define the RPM gates in a consistent manner ensuring that the tumor motion is restricted to 4 mm in 3D for lung SBRT patients. The method relies on studying the ratio of volumes obtained by GTVnn intersection with GTV50+2mm margin and GTVnn where GTVnn is the GTV volume in phase nn (=0,10,30.) while GTV50+2mm is a pseudo structure created by adding an isotropic margin of 2mm to GTV50. If for any phase nn, above ratio equals 1, it ensures that the tumor motion is ≤ ±2 mm in 3D from GTV50. Methods: This method was tested for 50 patients (14-Central, 36-peripheral) to determine the RPM gates which were then compared with the gates used clinically. The minimum cut-off value of the above coefficient for its inclusion of a phase in RPM gate was taken as 0.97 for central and 0.95 for peripheral tumors. Results: 15 (30%) of the patients did not require any change in the RPM gates w.r.t. gates defined using conventional motion assessment methods. In 15(30%) cases, the RPM gates could have been smaller while in remaining 20 patients, gates could have been larger. 5(/14) patient’s central tumors and 10 (/36) peripheral tumors did not need any gate change. 8(/50) patients could have RPM gate change of 30% while 10(/50) could have a gate change of up to 20%. 10, 20 & 30% RPM gate change could have happened for 11, 10 & 9 patients, respectively. Conclusion: Proposed volumetric indices based method allows a consistent, scientific and objective method to decide optimal RPM gates which is free from any inter or intra person variability and satisfies the tumor motion limits as defined by AAPM TG-76 in totality.

60 APPLIED LIFE SCIENCES↗

SU-E-T-403: Evaluation of the Beam Performance of a Varian TrueBeam Linear Accelerator Under External Device-Based Gated Delivery Conditions

Purpose: To examine the beam performance of a Varian TrueBeam linear accelerator under external device-based gated delivery conditions. Methods: Six gating cycles were used to evaluate the gating performance of a standard production TrueBeam system that was not specially tuned in any way. The system was equipped with a factory installed external gating interface (EXGI). An in-house EXGI tester box was used to simulate the input gating signals. The gating cycles were selected based on long beam-on and short beam-off times, short beam-on and long beam-off times, or equal beam on and off times to check linac performance. The beam latencies were measured as the time difference between the logic high gating signal and the first or last target pulses with an oscilloscope. Tissue-Phantom Ratio, beam flatness, and dose distributions from 5 different plans were measured using the 6 different gating durations and the un-gated irradiation. A PTW 729 2-D array was used to compare 5 plans versus the un-gated delivery with a 1%/1mm gamma index passing criteria. Results: The beam latencies of the linac were based off of 20 samples for beam-on and beam-off, for each gating cycle. The average beam-on delays were measured to be between 57 and 66msec, with a maximum of 88 msec. The beam off latencies averaged between 19 and 26msec, with a maximum of 48 msec. TPR20,10 measurements showed beam energy stability within 0.5% of the un-gated delivery. Beam flatness was better than 2.5% for all gated cycles. All but two deliveries, the open field with 4 seconds on, 1 second off, and a five field IMRT plan with 0.5 seconds on, 2.5 seconds off, had >90% passing rate. Conclusion: TrueBeam demonstrates excellent beam stability with minimal beam latencies under external device-based gated operations. Dosimetric measurements show minimal variation in beam energy, flatness, and plan delivery. Authors are employees of Varian Medical Systems, Inc.

60 APPLIED LIFE SCIENCES↗

SU-E-T-439: Fundamental Verification of Respiratory-Gated Spot Scanning Proton Beam Therapy

Purpose: The spot-scanning proton beam irradiation with respiratory gating technique provides quite well dose distribution and requires both dosimetric and geometric verification prior to clinical implementation. The purpose of this study is to evaluate the impact of gating irradiation as a fundamental verification. Methods: We evaluated field width, flatness, symmetry, and penumbra in the gated and non-gated proton beams. The respiration motion was distinguished into 3 patterns: 10, 20, and 30 mm. We compared these contents between the gated and non-gated beams. A 200 MeV proton beam from PROBEAT-III unit (Hitachi Co.Ltd) was used in this study. Respiratory gating irradiation was performed by Quasar phantom (MODUS medical devices) with a combination of dedicated respiratory gating system (ANZAI Medical Corporation). For radiochromic film dosimetry, the calibration curve was created with Gafchromic EBT3 film (Ashland) on FilmQA Pro 2014 (Ashland) as film analysis software. Results: The film was calibrated at the middle of spread out Bragg peak in passive proton beam. The field width, flatness and penumbra in non-gated proton irradiation with respiratory motion were larger than those of reference beam without respiratory motion: the maximum errors of the field width, flatness and penumbra in respiratory motion of 30 mm were 1.75% and 40.3% and 39.7%, respectively. The errors of flatness and penumbra in gating beam (motion: 30 mm, gating rate: 25%) were 0.0% and 2.91%, respectively. The results of symmetry in all proton beams with gating technique were within 0.6%. Conclusion: The field width, flatness, symmetry and penumbra were improved with the gating technique in proton beam. The spot scanning proton beam with gating technique is feasible for the motioned target.

60 APPLIED LIFE SCIENCES↗

TH-CD-207A-04: Optimized Respiratory Gating for Abnormal Breathers in Pancreatic SBRT

Purpose: Pancreatic SBRT is uniquely challenging due to both the erratic/unstable motion of the pancreas and the close proximity of the radiosensitive small bowel. Respiratory gating can mitigate this effect, but the irregularity of motion severely affects traditional phase-based gating. The purpose of this study was to analyze real-time motion data of pancreatic tumors to optimize the efficacy and accuracy of respiratory gating, with the overall goal of enabling dose escalated pancreatic SBRT. Methods: Fifteen pancreatic SBRT patients received 30–33 Gy in 5 fractions on a Varian TrueBeam STx unit. Abdominal compression was used to reduce the amplitude of tumor motion, and daily cone-beam computed tomography (CBCT) scans were acquired prior to each treatment for target localization purposes. For this study, breathing data (phase and amplitude) were collected during each CBCT scan using Varian’s Real-Time Position Management system. An in-house template matching technique was used to track the superior-inferior motion of implanted fiducial markers in CBCT projection images. Using tumor motion and breathing data, phase-based or amplitude-based respiratory gating was simulated for all 75 fractions, targeting either end-exhalation or end-inhalation phases of breathing. Results: For the average patient, gating at end-exhalation offered the best reductions in effective motion for equal duty cycles. However, optimal central phase angle varied widely (range: 0–92%, mean±SD: 49±12%), and phase-based gating windows typically associated with end-exhalation (i.e., “30–70%”) were rarely ideal. Amplitude-based gating significantly outperformed phase-based gating, with average effective ranges for amplitude-based gating 25% lower than phase-based gating ranges (as much as 73% lower). Amplitude-based gating was consistently better suited to accommodate abnormal breathing patterns. For both phase-based and amplitude-based gating, end-exhalation provided significantly better results than end-inhalation. Conclusion: Amplitude-based gating reliably outperformed phase-based gating, and end-exhalation was more suitable than end-inhalation. These results will be used to guide future dose-escalation trials. Research funding provided by Varian Medical Systems to Miften and Jones.

60 APPLIED LIFE SCIENCES↗

Direct pulse-level compilation of arbitrary quantum logic gates on superconducting qutrits

Advanced simulations and calculations on quantum computers require high-fidelity implementations of quantum operations. The universal gateset approach builds complex unitaries from a small set of primitive gates, often resulting in a long gate sequence, which is typically a leading factor in the total accumulated error. Compiling a complex unitary for processors with higher-dimensional logical elements, such as qutrits, exacerbates the accumulated error per unitary, since an even longer gate sequence is required. Optimal control methods promise time- and resource-efficient compact gate sequences and, therefore, higher fidelity. These methods generate pulses that can directly implement any complex unitary on a quantum device. In this work, we demonstrate that any arbitrary qubit and qutrit gate can be realized with high fidelity, which can significantly reduce the length of a gate sequence. We generate and test pulses for a large set of randomly selected arbitrary unitaries on several quantum processing units (QPUs): the Lawrence Livermore National Laboratory Quantum Device and Integration Testbed’s (QuDIT’s) standard QPU and three of Rigetti’s QPUs: Ankaa-2, Ankaa-9Q-1, and Aspen-M-3. On the QuDIT platform’s standard QPU, the average fidelity of random qutrit gates is 97.9 ± 0.5% measured with conventional QPT and 98.8 ± 0.6% from QPT with gate folding. Rigetti’s Ankaa-2 achieves random qubit gates with an average fidelity of 98.4 ± 0.5% (conventional QPT) and 99.7 ± 0.1% (QPT with gate folding). On Ankaa-9Q-1 and Aspen-M-3, the average fidelities with conventional qubit QPT measurements were higher than 99% (see Appendix). Here we show that optimal control gates are robust to drift for at least 3 h and that the same calibration parameters can be used for all implemented gates. Our work promises that the calibration overheads for optimal control gates can be made small enough to enable efficient quantum circuits based on this technique.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Examination of geometric and dosimetric accuracies of gated step-and-shoot intensity modulated radiation therapy

Due to the complicated technical nature of gated radiation therapy, electronic and mechanical limitations may affect the precision of delivery. The purpose of this study is to investigate the geometric and dosimetric accuracies of gated step-and-shoot intensity modulated radiation treatments (SS-IMRT). Unique segmental MLC plans are designed, which allow quantitative testing of the gating process. Both ungated and gated deliveries are investigated for different dose sizes, dose rates, and gating window times using a commercial treatment system (Varian Trilogy) together with a respiratory gating system [Varian Real-Time Position Management system]. Radiographic film measurements are used to study the geometric accuracy, where it is found that with both ungated and gated SS-IMRT deliveries the MLC leaf divergence away from planned is less than or equal to the MLC specified leaf tolerance value for all leafs (leaf tolerance being settable from 0.5-5 mm). Nevertheless, due to the MLC controller design, failure to define a specific leaf tolerance value suitable to the SS-IMRT plan can lead to undesired geometric effects, such as leaf motion of up to the maximum 5 mm leaf tolerance value occurring after the beam is turned on. In this case, gating may be advantageous over the ungated case, as it allows more time for the MLC to reach the intended leaf configuration. The dosimetric precision of gated SS-IMRT is investigated using ionization chamber methods. Compared with the ungated case, it is found that gating generally leads to increased dosimetric errors due to the interruption of the 'overshoot phenomena.' With gating the average timing deviation for intermediate segments is found to be 27 ms, compared to 18 ms for the ungated case. For a plan delivered at 600 MU/min this would correspond to an average segment dose error of {approx}0.27 MU and {approx}0.18 MU for gated and ungated deliveries, respectively. The maximum dosimetric errors for individual intermediate segments are found to deviate by up to {approx}0.64 MU from their planned value when delivered at 600 MU/min using gating, this compares to only {approx}0.32 MU for the ungated case.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantifying the impact of respiratory-gated 4D CT acquisition on thoracic image quality: A digital phantom study

Purpose: Prospective respiratory-gated 4D CT has been shown to reduce tumor image artifacts by up to 50% compared to conventional 4D CT. However, to date no studies have quantified the impact of gated 4D CT on normal lung tissue imaging, which is important in performing dose calculations based on accurate estimates of lung volume and structure. To determine the impact of gated 4D CT on thoracic image quality, the authors developed a novel simulation framework incorporating a realistic deformable digital phantom driven by patient tumor motion patterns. Based on this framework, the authors test the hypothesis that respiratory-gated 4D CT can significantly reduce lung imaging artifacts. Methods: Our simulation framework synchronizes the 4D extended cardiac torso (XCAT) phantom with tumor motion data in a quasi real-time fashion, allowing simulation of three 4D CT acquisition modes featuring different levels of respiratory feedback: (i) “conventional” 4D CT that uses a constant imaging and couch-shift frequency, (ii) “beam paused” 4D CT that interrupts imaging to avoid oversampling at a given couch position and respiratory phase, and (iii) “respiratory-gated” 4D CT that triggers acquisition only when the respiratory motion fulfills phase-specific displacement gating windows based on prescan breathing data. Our framework generates a set of ground truth comparators, representing the average XCAT anatomy during beam-on for each of ten respiratory phase bins. Based on this framework, the authors simulated conventional, beam-paused, and respiratory-gated 4D CT images using tumor motion patterns from seven lung cancer patients across 13 treatment fractions, with a simulated 5.5 cm{sup 3} spherical lesion. Normal lung tissue image quality was quantified by comparing simulated and ground truth images in terms of overall mean square error (MSE) intensity difference, threshold-based lung volume error, and fractional false positive/false negative rates. Results: Averaged across all simulations and phase bins, respiratory-gating reduced overall thoracic MSE by 46% compared to conventional 4D CT (p ∼ 10{sup −19}). Gating leads to small but significant (p < 0.02) reductions in lung volume errors (1.8%–1.4%), false positives (4.0%–2.6%), and false negatives (2.7%–1.3%). These percentage reductions correspond to gating reducing image artifacts by 24–90 cm{sup 3} of lung tissue. Similar to earlier studies, gating reduced patient image dose by up to 22%, but with scan time increased by up to 135%. Beam paused 4D CT did not significantly impact normal lung tissue image quality, but did yield similar dose reductions as for respiratory-gating, without the added cost in scanning time. Conclusions: For a typical 6 L lung, respiratory-gated 4D CT can reduce image artifacts affecting up to 90 cm{sup 3} of normal lung tissue compared to conventional acquisition. This image improvement could have important implications for dose calculations based on 4D CT. Where image quality is less critical, beam paused 4D CT is a simple strategy to reduce imaging dose without sacrificing acquisition time.

60 APPLIED LIFE SCIENCES↗

Technical Note: Validation and implementation of a wireless transponder tracking system for gated stereotactic ablative radiotherapy of the liver

Purpose: Tracking soft-tissue targets has recently been cleared as a new application of Calypso, an electromagnetic wireless transponder tracking system, allowing for gated treatment of the liver based on the motion of the target volume itself. The purpose of this study is to describe the details of validating the Calypso system for wireless transponder tracking of the liver and to present the clinical workflow for using it to deliver gated stereotactic ablative radiotherapy (SABR). Methods: A commercial 3D diode array motion system was used to evaluate the dynamic tracking accuracy of Calypso when tracking continuous large amplitude motion. It was then used to perform end-to-end tests to evaluate the dosimetric accuracy of gated beam delivery for liver SABR. In addition, gating limits were investigated to determine how large the gating window can be while still maintaining dosimetric accuracy. The gating latency of the Calypso system was also measured using a customized motion phantom. Results: The average absolute difference between the measured and expected positional offset was 0.3 mm. The 2%/2 mm gamma pass rates for the gated treatment delivery were greater than 97%. When increasing the gating limits beyond the known extent of planned motion, the gamma pass rates decreased as expected. The 2%/2 mm gamma pass rate for a 1, 2, and 3 mm increase in gating limits was measured to be 97.8%, 82.9%, and 61.4%, respectively. The average gating latency was measured to be 63.8 ms for beam-hold and 195.8 ms for beam-on. Four liver patients with 17 total fractions have been successfully treated at our institution. Conclusions: Wireless transponder tracking was validated as a dosimetrically accurate way to provide gated SABR of the liver. The dynamic tracking accuracy of the Calypso system met manufacturer’s specification, even for continuous large amplitude motion that can be encountered when tracking liver tumors close to the diaphragm. The measured beam-hold gating latency was appropriate for targets that will traverse the gating limit each respiratory cycle causing the beam to be interrupted constantly throughout treatment delivery.

60 APPLIED LIFE SCIENCES↗

SU-F-T-526: A Comparative Study On Gating Efficiency of Varian RPM Device and Calypso System

Purpose: In general, the linear accelerator is gated using respiratory signal obtained by way of external sensors to account for the breathing motion during radiotherapy. One of the commonly used gating devices is the Varian RPM device. Calypso system that uses electromagnetic tracking of implanted or surface transponders could also be used for gating. The aim of this study is to compare the gating efficiency of RPM device and the calypso system by phantom studies. Methods: An ArcCheck insert was used as the phantom with a Gafchromic film placed in its holder. The ArcCheck insert was placed on a Motion Sim platform and moved in the longitudinal direction simulating a respiratory motion with a period of 5 seconds and amplitude of ±6mm. The Gafchromic film was exposed to a 2 × 2cm{sup 2} field, i) with the phantom static, ii) phantom moving but ungated iii) gated with gating window of 2mm and 3mm. This was repeated with Calypso system using surface transponders with the same gating window. The Gafchromic films were read with an EPSON 11000 flatbed scanner and analysed with ‘Medphysto’ software. Results: The full width at half maximum (FWHM) as measured with film at the level of the film holder was 1.65cm when the phantom was static. FWHM measured with phantom moving and without gating was 1.16 cm and penumbra was 7 mm (80–20%) on both sides. When the beam was gated with 2 mm gating window the FWHM was 1.8 cm with RPM device and 1.9 cm with Calypso. Similarly, when the beam was gated with 3 mm window, the FWHM was 1.9cm with RPM device and 2cm with Calypso. Conclusion: This work suggests that the gating efficiency of RPM device is better than that of the Calypso with surface transponder, with reference to the latency in gating.

60 APPLIED LIFE SCIENCES↗

SU-F-T-634: Feasibility Study of Respiratory Gated RapidArc SBRT Using a 6MV FFF Photon Beam

Purpose: To conduct a feasibility study on retrospective respiratory gating and marker tracking for lung stereotactic body radiotherapy (SBRT) with a gated RapidArc delivery using a 6MV flattened filter free photon mode. Methods: A CIRS dynamic thorax phantom Model 008A with different inserts was used for treatment planning and respiratory gating. 4D CT had a free breathing simulation followed by a respiration gated, ten phased CT using a Philips Brilliance CT with a Varian RPM respiratory gating system. The internal target volume was created from the ten phase gated CT images, followed by exporting to a Varian Eclipse TPS v11 for treatment planning on the free breath images. Both MIP and AIP were also generated for comparison of planning and target motion tracking. The planned dose was delivered with a 6MV FFF photon beam from a Varian TrueBeam accelerator. Gated target motion was also verified by tracking the implanted makers during delivery using continuous kV imaging in addition to CBCT, kV and MV localization and verification. Results: Gating was studied in three situations of lower, normal, and faster breathing at a respiratory cycle of 5, 15 and 25 breaths per minute, respectively. 4D treatment planning was performed at a normal breathing of 15 breaths per minute. The gated patterns obtained using the TrueBeam IR camera were compared with the planned ones while gating operation was added prior to delivery . Gating was realized only when the measured respiratory patterns matched to the planned ones. The gated target motion was verified within the tolerance by kV and MV imaging. Either free breathing CT or averaged CT images were studied to be good for image guidance to align the target. Conclusion: Gated RapidArc SBRT delivered with a 6MV FFF photon beam is realized using a dynamic lung phantom.

60 APPLIED LIFE SCIENCES↗