Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “galvanic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Design Optimization of Energized Composite Using Simulation and Experimental Methods

As electric vehicles (EVs) are evolving, innovative technologies like “energized composite” that can store energy in the car's body helps extend its range per charge. The composite's unique ability to function as both structural body panel and charge storage medium stems from its unique pattern design between “electrochemical areas (EcA)” and “epoxy area (EpA)”. Herein, a design optimization study is presented to obtain a balanced ratio between EcA versus EpA to maximize the charge storage ability of the composite while maintaining a decent tensile and bending strength. Simulations using ANSYS software and experimental confirmation using universal testing machines and electrochemical analyzers are used to derive optimum ratios between EcA and EpA. Uniaxial tension test and 3-point bend test have been performed to optimize the tensile and bend strengths, whereas cyclic voltammetry, galvanic charge–discharge, and electrochemical impedance spectroscopy are used to determine the electrochemical performance of various design configurations by modulating the ratios of EcA versus EpA. Overall, the highest achieved energy storage per lamina is 2531 mWh m−2 for a maximum of 81.6% EcA with a tensile strength of 417.73 MPa and bending strength of 263.13 MPa. This study is highly beneficial for EVs and aerospace applications.

energy storage↗

The Ribofilm as a Concept for Life’s Origins

Recent phylogenetic data indicating that the first archaea were methane-producing galvanizes cross-disciplinary evidence supporting the hypothesis that life arose via thermodynamically directed events at hydrothermal vents. The new developments lead us to propose the concept of a ribofilm in which RNA’s origin-of-life role is more akin to a slowly changing platform than a spontaneous self-replicator.

John A Baross↗

Validation of A Sensorimotor Disorientation Ground Analog

INTRODUCTION Simulating the sensorimotor disorientation effects of gravity transitions after prolonged stays in microgravity is exceedingly challenging on Earth. In a previous study [1], a Sensorimotor Disorientation Analog (SDA) was developed based on subjective feedback from previously flown astronauts. The purpose of this study was to validate this SDA by comparing performance in movement tasks that have a wealth of spaceflight data against task performance while using the SDA. METHODS Thirty healthy non-astronaut subjects (17 males, 13 females; Mean ± SD, Age: 33.5 ± 7.2 years, Height: 68.0 ± 3.4 in, Weight: 164 ± 26 lbs.) volunteered to participate in this study. Subjects performed three movement tasks: computerized dynamic posturography (CDP), obstacle walk, and tandem walk. For CDP, subjects maintained an upright stance for 20s with eyes closed on an unstable pitch sway-referenced platform with head erect (sensory organization test (SOT)-5) and with head pitch ±20° to an auditory cue(SOT-5M). The obstacle walk involved a sit-to-stand with 10s of quiet stance followed by walking to and around a cone placed 4m away while navigating a 30cm obstacle to the cone and back. The tandem walk involved walking heel-to-toe for approximately 10-12 steps with eyes open and eyes closed. Subjects performed the three movement tasks under three levels of the SDA replicating different time points of recovery: none (preflight), low (Return (R)+24- 48hours), and high (R+0- 24hours). The SDA included galvanic vestibular stimulation (GVS) to disorient the vestibular system and a weighted suit (trunk, wrists, and ankles) to alter proprioceptive feedback and replicate subjective heaviness. RESULTS As the SDA magnitude increased, overall performance outcomes decreased. However, the ability of the SDA to replicate the range of astronaut postflight performance was task dependent. CDP SOT-5 performance across SDA levels closely replicated astronaut performance at all time points. SOT-5M, however, had minimal performance changes across SDA levels and was unable to replicate astronaut performance. The obstacle walk showed performance changes across SDA levels and matched astronaut performance preflight and at R+24-48hrs (low). Obstacle walk performance at the high SDA level was reduced in comparison to the low level; however, it was not replicative of astronaut performance immediately after landing. Last, tandem walk had distinct groupings of performance across SDA levels and was able to elicit a high level of disorientation consistent with R+0-24 hours (high) postflight performance for eyes open and eyes closed. The low SDA level for both eyes open and eyes closed was more disruptive than previous crewmember performance at the R+24-48 hours timepoint. CONCLUSION The SDA was developed to replicate postflight sensorimotor disruptions. However, it is well-known that immediately post-landing, astronauts can experience motion sickness, dehydration, fatigue, orthostatic intolerance, illusory sensations, lumbar pain, etc. This multi-system response to return to 1G varies widely across astronauts and, as such, it was not unexpected that the extreme ends of responses in the R+0-24hrs time period were the most difficult to replicate. These results suggest that the SDA levels are able to elicit distinct performance groupings and, although not able to perfectly replicate R+0-24hrs, the SDA did replicate a large range of performance after return to Earth.

S C Moudy↗

Safe Exploration: Sensorimotor Assessments for Early Extravehicular Activities

BACKGROUND: Artemis missions will require a new level of crew autonomy around periods of gravitational transition, where sensorimotor disturbances are at their highest. There is a need to define performance thresholds for key sensorimotor assessments that indicate when performance in early extravehicular activities (EVAs) might be impacted or unsafe. This panel presentation will discuss the development of sensorimotor assessments for determining crew preparedness of early EVAs by utilizing a novel portable sensorimotor disorientation analog and other spaceflight analogs. OVERVIEW: To define performance thresholds, a proposed set of sensorimotor assessment tasks must be validated under various spaceflight analogs. A Sensorimotor Disorientation Analog (SDA) was developed that could induce varying levels of disorientation through combined vestibular (galvanic vestibular stimulation (GVS)) and proprioceptive (weighted chest, ankles, and wrists) disruptions. The SDA was first pilot tested using subjective feedback from previously flown astronauts to determine the levels of disorientation that mimic motor performance immediately (R+0) and +24 hours (R+1) postflight. A second study was performed using healthy non-astronaut ground subjects to validate the SDA levels by comparing to astronaut postflight data. The validated SDA was utilized in a third study to map performance in the proposed set of sensorimotor assessment tasks to operational tasks. The assessment tasks were defined based on lessons learned from Apollo and subject matter experts (e.g., flight surgeons) to include the following: 1) aid in progressive adaptation to the novel gravitational environment; 2) provide opportunities to develop strategies to recover from off-nominal body positions; and 3) mimic operational tasks such that crew can self-assess their potential ability to complete their missions. This presentation will conclude with a discussion on future validation studies of the proposed assessment tasks using other spaceflight analogs such as centrifugation and gravity offload systems. DISCUSSION: Exploration class missions will require crew to be able to self-assess and treat their sensorimotor dysfunction after gravity transitions, and in off-nominal situations they may be required to perform provocative, challenging tasks soon after landing. This panel presentation will discuss current and ongoing research strategies to address the sensorimotor risk on safe exploration during Artemis missions.

Sarah Moudy↗

Cathode Modeling of Solid-State Batteries

The search for safe, reliable, and compact high-capacity energy storage devices has led to increased interest in all-solid-state battery research. The use of solid electrolytes provides enhanced safety and durability due to their reduced flammability and increased mechanical strength compared to organic liquid electrolytes. Still, the use of solid electrolytes remains challenging. Computational modeling plays a substantial role in addressing these challenges. A particle dynamics electromechanical model for simulating electrochemical processes in a solid-state battery cathode will be presented. The model presents cathode microstructure at the particle level as a mixture of ionically conductive solid electrolyte particles, electrically conductive carbon additives, and cathodic reactant particles. After densification, the particle connectivity is analyzed to reconstruct the complex electric network connecting reactant particles with an anodic and cathodic current collectors through the electrolyte and carbon particles. The Kirchhoff’s matrix equation describing this electric network, is solved to obtain values of various critical parameters, such as the overall conductivity of the cathode for lithium ions and electrons, cathodic reactant material utilization, and the distribution of the electric current and voltages within the cathode. In addition, by representing the reactant particles as electrolyte or galvanic microcells governed by the Butler-Volmer electrochemical equation, the overall performance of battery cells during charge or discharge processes, respectively, can be predicted for a given cathodic powder composition. The presented model, executed on a high-performance computing architecture, essentially provides a valuable guidance in designing and developing future solid-state batteries.

solid-state battery↗

Development and Validation of Sensorimotor Assessment Tasks Using Spaceflight Analogs

INTRODUCTION Exploration class missions will require a new level of crew autonomy to self-assess and treat their sensorimotor dysfunction around periods of gravitational transition, where sensorimotor disturbances are at their highest. There is a need to define sensorimotor assessment thresholds that indicate when performance in early extravehicular activities (EVAs) might be impacted or unsafe. The purpose of this study was to develop and validate a set of assessment tasks using sensorimotor spaceflight analogs including the Sensorimotor Disorientation Analog (SDA) and +3G x sustained centrifugation. METHODS For the SDA, forty-one healthy non-astronaut subjects (21 males, 20 females; Mean ± SD, Age: 34.0 ± 7.8 years) volunteered to participate in this study. Subjects attended two testing sessions: 1) familiarization to the tasks and baseline data collection, and 2) tasks completed under two levels of sensorimotor disorientation. Subjects performed a series of seven sensorimotor assessment tasks followed by two operationally relevant EVA analog tasks. The sensorimotor assessments tasks, ordered from least to most provocative of the sensorimotor system, included: postural stability, step test, prone/supine recovery from fall (RFF), four-square-step-test, obstacle negotiation with turns (OTT), kneel-and-reach, and augmented reality full-body coordination. The operational analog tasks included a top-hatch capsule egress and a 5-minute EVA traversal. Disorientation was applied via the SDA which utilized galvanic vestibular stimulation and weighted trunk, wrists, and ankles to target the vestibular and proprioceptive systems such that performance while wearing the SDA mimicked astronaut postflight performance at R+0 and R+1. Sixteen healthy non-astronaut subjects (10 males, 6 females; Age: 35.0 ± 9.5 years) completed +3G x 60-minute sustained centrifugation as an established spaceflight analog replicating the vestibular disruptions seen postflight. Subjects completed a pre-session which included familiarization to the tasks and a 5-minute centrifuge spin. The data collection session included, in order, a baseline data collection, 60-minute centrifuge spin, immediate post-centrifuge data collection, 45-minute seated recovery, and a final data collection. The same assessment and operational analog tasks were conducted as described above. RESULTS Pearsons’ correlation r-values were calculated between assessment and operational analog tasks. The two assessment tasks with the strongest correlations to the operational analog tasks were the RFF (SDA: r≥ 0.57, Centrifuge: r ≥0.55) and OTT (SDA: r≥ 0.66, Centrifuge: r ≥ 0.49). For brevity, repeated measures ANOVA with follow-up paired t-tests are discussed for these two assessment tasks. The SDA found significant differences between all three levels of disorientation for both RFF and OTT (p < 0.001). Significant differences were also found between baseline and immediate post centrifuge testing for both the RFF (p≤ 0.011) and OTT (p = 0.001). Additional results are forthcoming for both disorientation paradigms. DISCUSSION These validation studies provide evidence for down-selection of the assessment tasks that were able to distinguish between levels of sensorimotor disorientation and correlate to performance in operationally relevant tasks for use in upcoming Artemis missions.

S C Moudy↗

Reliability Models and Demonstration of a Fault-Tolerant Motor Concept for Vertical Takeoff and Landing Vehicles

This report documents the completion of the Revolutionary Vertical Lift Technology Project Annual Performance Indicator 24-3.2.4.1: “Apply and document reliability prediction for high reliability motor concept.” Two modeling tools were completed for calculation of reliability of fault-tolerant (FT) motors, and key FT operations of a modular FT motor were demonstrated experimentally. The two models are complementary tools for the stakeholder and user community. Both models employ Markov chain theory. The first model is a time-homogeneous Markov chain model, and the second is a time-inhomogeneous Markov-Weibull model. This report’s main sections are as follows: 1.0 Introduction, 2.0 Theory, 3.0 Motor Reliability Models, 4.0 Validation of FT Operation by Hardware Demonstration, and 5.0 Concluding Remarks. Novel contributions to the field include development of a modular FT motor concept for electrified vertical takeoff and landing (eVTOL) application, solution methods to solve the reliability calculations, development of figures of merit, and the introduction of “linked chains” to formulate a building-block approach for time-inhomogeneous Markov-Weibull modeling of motor reliability. Example case studies have been completed, and results are provided and discussed herein. A four-module FT motor concept was developed to a preliminary-design level of detail. This eVTOL FT motor concept was designed for galvanic, magnetic, and thermal isolation of stator winding faults. The reliability of the concept motor was calculated using a time-inhomogeneous Markov chain model. Employing average failure rate as a metric, 570 times greater reliability was achieved as compared to a baseline motor without fault tolerance. A demonstrator motor was built and tested. The testing demonstrated the key features of FT operation and validated the essential premises of the FT motor concepts presented herein. The experiments included successful demonstration of the feasibility of the following four key FT features: (1) terminal open-circuit operation, (2) thermal isolation after fault, (3) terminal short-circuit operation, and (4) internal short-circuit operation. These works indicate that FT modular motor drives offer promise for addressing the daunting reliability gap that electric aircraft propulsor drives are facing relative to the best conventional motor drive technology that is available today.

Electric Motor↗

Response time to colored stimuli in the full visual field

Peripheral visual response time was measured in seven dark adapted subjects to the onset of small (45' arc diam), brief (50 msec), colored (blue, yellow, green, red) and white stimuli imaged at 72 locations within their binocular field of view. The blue, yellow, and green stimuli were matched for brightness at about 2.6 sub log 10 units above their absolute light threshold, and they appeared at an unexpected time and location. These data were obtained to provide response time and no-response data for use in various design disciplines involving instrument panel layout. The results indicated that the retina possesses relatively concentric regions within each of which mean response time can be expected to be of approximately the same duration. These regions are centered near the fovea and extend farther horizontally than vertically. Mean foveal response time was fastest for yellow and slowest for blue. Three and one-half percent of the total 56,410 trials presented resulted in no-responses. Regardless of stimulus color, the lowest percentage of no-responses occurred within 30 deg arc from the fovea and the highest within 40 deg to 80 deg arc below the fovea.

Haines, R. F.↗

Low cost solar array project: Composition measurements by analytical photon catalysis

The applicability of the photon catalysis technique for effecting composition analysis of silicon samples is assessed. In particular, the technique is to be evaluated as a detector for the impurities Al, Cr, Fe, Mn, Ti, V, Mo and Zr. During the first reporting period Al, Cr, Fe and Mn were detected with the photon catalysis method. The best fluorescence lines to monitor and determined initial sensitivities to each of these elements by atomic absorption calibration were established. In the course of these tests, vapor pressure curves for these four pure substances were mapped.

Sutton, D. G.↗

Low Cost Solar Array Project: Composition Measurements by Analytical Photo Catalysis

The applicability of the photon catalysis technique for effecting composition analysis of silicon samples is discussed. A detector for the impurities Al, Cr, Fe, Mn, Ti, V, Mo and Zr is evaluated. During the first reporting period Al, Cr, Fe, and Mn were detected with the photon catalysis method. The best fluorescence lines to monitor and determine initial sensitivities to each of these elements by atomic absorption calibration were established. In the course of these tests vapor pressure curves for these four pure substances were also mapped. Ti and Si were detected. The best lines to monitor were catalogued and vapor pressure curves were determined. Attempts to detect vanadium were unsuccessful due to the refractory nature of this element and the limited temperature range of the evaporator.

Sutton, D. G.↗

Low Cost Solar Array Project: Composition Measurements by Analytical Photon Catalysis

The applicability of the photon catalysis technique for effecting composition analysis of silicon samples was assessed. Third quarter activities were devoted to the study of impurities in silicon matrices. The evaporation process was shown to be congruent; thus, the spectral analysis of the vapor yields the composition of the bulk sample. Qualitative analysis of metal impurities in silicon was demonstrated e part per million level. Only one atomic spectral interference was noted; however, it is imperative to maintain a leak tight system due to chemical and spectral interferences caused by the presence of even minute amounts of oxygen in the active nitrogen afterglow.

Sutton, D. G.↗

A Multi-Year Light Curve of Scorpius X-1 Based on CGRO BATSE Spectroscopy Detector Observations

A multi-year light curve of the low mass X-ray binary, Scorpius X-1, is constructed based on the Compton Gamma-ray Observatory (CGRO) Burst and Transient Source Experiment (BATSE) Spectroscopy Detector (SD) data in the nominal energy range of 10-20 keV. A detailed discussion is given of the reduction process of the BATSE/SD data. Corrections to the SD measurements are made for off-axis pointings, spectral and bandpass changes, and differences in the eight SD sensitivities. The resulting 4.4 year Sco X-1 SD light curve is characterized in terms of the time scales over which various types of emission changes occur. This light curve is then compared with Sco X-1 light curves obtained by Axiel 5, the BATSE Large Area Detectors (LADs), and the RXTE all-sky monitor (ASM). Coincident temporal coverage by the BATSE/SD and RXTE/ASM allows a direct comparison of the behavior of Sco X-1 over a range of high energies to be made. These ASM light curves are then used to discuss model constraints on the Sco X-1 system.

McNamara, B. J.↗

Microstructures in the Polar Solar Wind: Ulysses

We find that small (10-200 rP) magnetic decreases comprise a dominant part of the polar solar wind microstructure at Ulysses distances (2.2 AU). These magnetic field dips are almost always bounded by tangential discontinuities, a feature which is not well understood at this time. Hundreds of these events have been examined in detail and a variety of types have been found. These will be described. It is speculated that these structures have been generated by perpendicular heating of ions closer to the Sun and have then been convected to distances of Ulysses. Such structures may be very important for the rapid cross- field diffusion of ions in the polar regions of the heliosphere.

Tsuruyani, Bruce T.↗

[Individual characteristics of correction of the cosmonauts' vegetative status with a method of adaptive biofeedback]

The ability of 4 cosmonauts to voluntarily control their physiological parameters during the standing test was evaluated following a series of the adaptive feedback (AF) training sessions. Vegetative status of the cosmonauts during voluntary "relaxation" and "straining" was different when compared with its indices determined before these sessions. In addition, there was a considerable individual variability in the intensity and direction of the AF effects, and the range of parameters responding to AF. It was GCR which was the easiest one for the AF control.

NASA Center ARC↗

Skin cooling maintains cerebral blood flow velocity and orthostatic tolerance during tilting in heated humans

Orthostatic tolerance is reduced in the heat-stressed human. The purpose of this project was to identify whether skin-surface cooling improves orthostatic tolerance. Nine subjects were exposed to 10 min of 60 degrees head-up tilting in each of four conditions: normothermia (NT-tilt), heat stress (HT-tilt), normothermia plus skin-surface cooling 1 min before and throughout tilting (NT-tilt(cool)), and heat stress plus skin-surface cooling 1 min before and throughout tilting (HT-tilt(cool)). Heating and cooling were accomplished by perfusing 46 and 15 degrees C water, respectively, though a tube-lined suit worn by each subject. During HT-tilt, four of nine subjects developed presyncopal symptoms resulting in the termination of the tilt test. In contrast, no subject experienced presyncopal symptoms during NT-tilt, NT-tilt(cool), or HT-tilt(cool). During the HT-tilt procedure, mean arterial blood pressure (MAP) and cerebral blood flow velocity (CBFV) decreased. However, during HT-tilt(cool), MAP, total peripheral resistance, and CBFV were significantly greater relative to HT-tilt (all P < 0.01). No differences were observed in calculated cerebral vascular resistance between the four conditions. These data suggest that skin-surface cooling prevents the fall in CBFV during upright tilting and improves orthostatic tolerance, presumably via maintenance of MAP. Hence, skin-surface cooling may be a potent countermeasure to protect against orthostatic intolerance observed in heat-stressed humans.

Clinical Trial↗

Autogenic-feedback training exercise is superior to promethazine for control of motion sickness symptoms

Motion sickness symptoms affect approximately 50% of the crew during space travel and are commonly treated with intramuscular injections of promethazine. The purpose of this paper is to compare the effectiveness of three treatments for motion sickness: intramuscular injections (i.m.) of promethazine, a physiological training method (autogenic-feedback training exercise [AFTE]), and a no-treatment control. An earlier study tested the effects of promethazine on cognitive and psychomotor performance and motion sickness tolerance in a rotating chair. For the present paper, motion sickness tolerance, symptom reports, and physiological responses of these subjects were compared to matched subjects selected from an existing database who received either AFTE or no treatment. Three groups of 11 men, between the ages of 33 and 40 years, were matched on the number of rotations tolerated during their initial rotating-chair motion sickness test. The motion sickness test procedures and the 7-day interval between tests were the same for all subjects. The drug group was tested under four treatment conditions: baseline (no injections), a 25 mg dose of promethazine, a 50 mg dose of promethazine, and a placebo of sterile saline. AFTE subjects were given four 30-minute AFTE sessions before their second, third, and fourth motion sickness tests (6 hours total). The no-treatment control subjects were only given the four rotating-chair tests. Motion sickness tolerance was significantly increased after 4 hours of AFTE when compared to either 25 mg (p < 0.00003) or 50 mg (p < 0.00001) of promethazine. The control and promethazine groups did not differ. AFTE subjects reported fewer or no symptoms at higher rotational velocities than subjects in the control or promethazine groups. The primary physiological effect of promethazine was an inhibition of skin conductance level. The AFTE group showed significantly less heart rate and skin conductance variability during motion sickness tests administered after training.

Clinical Trial↗