Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “frequency response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Characteristics of hingeless rotors with hub moment feedback controls including experimental rotor frequency response, Volume 1

Wind tunnel tests to determine the dynamic characteristics of hingeless rotors with hub moment feedback controls and to acquire experimental hingeless rotor transfer functions are discussed. Rotor transfer functions were calculated from data acquired during open loop frequency response tests. The transfer functions are linear and present the rotor longitudinal and lateral frequency responses to collective pitch, longitudinal cyclic pitch, and lateral cyclic pitch. The theoretical analysis was based on the rigid blade flapping model coupled with appropriate control system and cyclic pitch actuator equations of motion.

Kuczynski, W. A.↗

Comparison of theory with the experimental characterization of the spatial frequency response of interferometers using a binary pseudo-random array sample

Experimental evaluations of the surface height response of an interference microscope using a binary pseudo-random array test sample are compared with a theory based on a Fourier optics model. Measurements of key instrument characteristics, including the illumination, imaging, and obscuring apertures of three different Mirau objectives, support the theoretical calculations. Agreement between experimental and theoretical modeling confirms the predictability of the spatial frequency response for the purpose of specification and optimization of instrument configuration for specific metrology tasks. The results also provide confidence in methods of compensating for the decrease in instrument response with spatial frequency.

Calibration↗

Optimization of the frequency response of a novel GaAs plasmonic terahertz detector

Previously there was reported a new type of high-speed plasmonic THz detector that can operate at room temperature. As an extension of that work, the sensitivity of the detector was investigated over a wide range of sub-THz frequencies. The measured frequency response is not purely monotonic but exhibits oscillatory behaviour with a number of maxima and minima. Our study reveals that such frequency dependence is caused by the interference of electromagnetic waves inside the detector substrate, as the frequencies of these extrema are found to be governed by the substrate thickness. We demonstrate that sensitivity of this type of detector can be optimized for the desired operating frequency within 0.06–0.7 THz spectrum by adjusting the substrate thickness. We also show that a monotonic frequency response with eliminated minima can be achieved by mounting the detector on a specially designed silicon lens.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Adaptive Load Shedding as Part of Primary Frequency Response To Support Networked Microgrid Operations

Global changes in the deployment of distributed energy resources, control and communications technologies, business models, and regulatory policy are increasing the operational options for future distribution systems. One such option is the coordinated operation of distributed resources to form microgrids and networks of microgrids to support traditional bulk power systems during normal operations and critical end-use loads during outages. While individual standalone microgrids have been extensively studied and deployed, the coordinated operation of networked microgrids is operationally more challenging due to the dynamic boundaries and changing mix of generation resources. Here, this paper presents a method of using a distributed control architecture to support primary frequency response in networked microgrids operations. The support of primary frequency response is accomplished using the Open Field Message Bus reference architecture and Grid Friendly Appliance controllers.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Sinusoidal Siemens star spatial frequency response measurement errors due to misidentified target centers

Numerous methods are available to measure the spatial frequency response (SFR) of an optical system. A recent change to the ISO 12233 photography resolution standard includes a sinusoidal Siemens star test target. We take the sinusoidal Siemens star proposed by the ISO 12233 standard, measure system SFR, and perform an analysis of errors induced by incorrectly identifying the center of a test target. We show a closed-form solution for the radial profile intensity measurement given an incorrectly determined center and describe how this error reduces the measured SFR of the system. As a result, using the closed-form solution, we propose a two-step process by which test target centers are corrected and the measured SFR is restored to the nominal, correctly centered values.

79 ASTRONOMY AND ASTROPHYSICS↗

Efficient Methods for Aircraft Frequency Response Estimation at NASA

Methods developed at NASA for efficiently estimating multiple-input multiple-output frequency responses of various aircraft control loops are discussed. These methods use simultaneous orthogonal multisine excitations and ratios of input-output Fourier transform data that can be computed in real time. An example is given to demonstrate some of the methods using flight test data for the X-56A airplane.

Frequency responses↗

Fast Computation of Frequency Response of Cavity-Backed Apertures Using MBPE in Conjunction with Hybrid FEM/MoM Technique

The hybrid Finite Element Method(FEM)/Method of Moments(MoM) technique has become popular over the last few years due to its flexibility to handle arbitrarily shaped objects with complex materials. One of the disadvantages of this technique, however, is the computational cost involved in obtaining solutions over a frequency range as computations are repeated for each frequency. In this paper, the application of Model Based Parameter Estimation (MBPE) method[1] with the hybrid FEM/MoM technique is presented for fast computation of frequency response of cavity-backed apertures[2,3]. In MBPE, the electric field is expanded in a rational function of two polynomials. The coefficients of the rational function are obtained using the frequency-derivatives of the integro-differential equation formed by the hybrid FEM/MoM technique. Using the rational function approximation, the electric field is calculated at different frequencies from which the frequency response is obtained.

Reddy, C. J.↗

Reduced-Order Aerodynamic Modeling Based on CFD Frequency Responses from Multisine Inputs

A system identification analysis was performed to determine reduced-order models of a computational fluid dynamics (CFD) solver for linear aeroelastic analysis and control design. The application was to the FUN3D code and the flexible half-span wind tunnel test article, in transonic flow conditions, used in the NASA-Boeing collaboration called the Integrated Adaptive Wing Technology Maturation (IAWTM) project. Multiple inputs (structural mode displacements and control surface deflections) were simultaneously excited with orthogonal phase-optimized multisines and multiple outputs (generalized aerodynamic forces) were recorded, from which the matrix of frequency responses were computed using a single CFD run. A state-space model was then fit to the frequency response data using a maximum-likelihood estimator.

System identification↗

Generation of High Frequency Response in a Dynamically Loaded, Nonlinear Soil Column

Detailed guidance on linear seismic analysis of soil columns is provided in “Seismic Analysis of Safety-Related Nuclear Structures and Commentary (ASCE 4, 1998),” which is currently under revision. A new Appendix in ASCE 4-2014 (draft) is being added to provide guidance for nonlinear time domain analysis which includes evaluation of soil columns. When performing linear analysis, a given soil column is typically evaluated with a linear, viscous damped constitutive model. When submitted to a sine wave motion, this constitutive model produces a smooth hysteresis loop. For nonlinear analysis, the soil column can be modelled with an appropriate nonlinear hysteretic soil model. For the model in this paper, the stiffness and energy absorption result from a defined post yielding shear stress versus shear strain curve. This curve is input with tabular data points. When submitted to a sine wave motion, this constitutive model produces a hysteresis loop that looks similar in shape to the input tabular data points on the sides with discontinuous, pointed ends. This paper compares linear and nonlinear soil column results. The results show that the nonlinear analysis produces additional high frequency response. The paper provides additional study to establish what portion of the high frequency response is due to numerical noise associated with the tabular input curve and what portion is accurately caused by the pointed ends of the hysteresis loop. Finally, the paper shows how the results are changed when a significant structural mass is added to the top of the soil column.

nonlinear↗

Distribution Feeder-Scale Fast Frequency Response via Optimal Coordination of Net-load Resources Part I: Solution Design

This work is the first of a two-part series that develops and experimentally demonstrates a first-of-its-kind hierarchical control solution for optimally dispatching thousands of deferrable loads and distributed energy resources (DERs) across a distribution feeder to provide fast frequency response (FFR) within 500 ms to the bulk power system. This approach rapidly coordinates resources online after a frequency event occurs, allowing fast-changing, behind-the-meter (BTM) resources to be incorporated and aggregate FFR power set points to be achieved more quickly and accurately than existing approaches. We also present a solution for determining the optimal amount of headroom to operate solar inverters with to minimize opportunity cost while ensuring the FFR response viability of a building with the inverter and deferrable loads. In Part I, we develop practical algorithms for fast, cost-based optimal dispatch at multiple aggregation scales (single building, multiple buildings, and full distribution feeder), establish their optimality, and demonstrate via simulation that they are faster than state-of-the-art, coordinated frequency response approaches. In Part II, the entire platform is implemented and experimentally verified using a unique power hardware-in-the-loop demonstration, including more than 100 powered loads and DERs connected to a real-world distribution network model and over 10,000 net-load resources dispatched.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Measurement of frequency response in short thermocouple wires

Experimental measurements are made for the steady-state frequency response of a supported thermocouple wire. In particular, the effects of axial heat conduction are demonstrated for both a supported one material wire (type K) and a two material wire (type T) with unequal material properties across the junction. The data for the amplitude ratio and phase angle are correlated to within 10 percent with the theoretical predictions of Fralick and Forney (1991). This is accomplished by choosing a natural frequency omega(sub n) for the wire data to correlate the first order response at large gas temperature frequencies. It is found that a large bead size, however, will increase the amplitude ratio at low frequencies but decreas the natural frequency of the wire. The phase angle data are also distorted for imperfect junctions.

Forney, L. J.↗

Measurement of frequency response in short thermocouple wires

Experimental measurements are made for the steady-state frequency response of a supported thermocouple wire. In particular, the effects of axial heat conduction are demonstrated for both a supported one material wire (type K) and a two material wire (type T) with unequal material properties across the junction. The data for the amplitude ratio and phase angle are correlated to within 10 percent with the theoretical predictions of Fralick and Forney (1991). This is accomplished by choosing a natural frequency omega(sub n) for the wire data to correlate the first order response at large gas temperature frequencies. It is found that a large bead size, however, will increase the amplitude ratio at low frequencies but decrease the natural frequency of the wire. The phase angle data are also distorted for imperfect junctions.

Forney, L. J.↗

System identification and controller design using experimental frequency response data

Recent findings from modeling and controller design for the NASA-Marshall Single Structure Control Facility have raised questions regarding the ability of modern control design techniques and modern modeling techniques to deal effectively with the stringent modeling and control design requirements of Large Space Structure Control. A brief and general discussion is presented of the results of studies into the modeling and control issues performed under sponsorship of the NASA/ASEE Summer Faculty Fellowship Program. Several issues are addressed. The first is a study of a modeling technique based on least squares identification of individual transfer functions from measured frequency response data. The second is a study of multiobjective optimization techniques applied to the modeling, or system identification, problem. The third issue is a study into the question of whether multiobjective optimization approaches can be effectively used for control system design using only frequency response data, thereby bypassing the difficult modeling problem. The last issue studied involves the resolution of seeming discrepancies between predicted and measured control computer time delays in the Single Structure Control Facility.

Irwin, R. Dennis↗