Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flow meter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

ExaWind: Opportunity for Discovery

The predictive simulation of the dynamics of modern wind turbines and wind farms is a high-performance-computing (HPC) grand challenge. Modern wind turbines are the largest rotating machines in the world, with rotor diameters exceeding 200 meters, and with heights well into the atmospheric boundary layer. To address this grand challenge, the U.S. Department of Energy (DOE) Wind Energy Technologies Office and the Exascale Computing Project have been supporting the creation of the ExaWind modeling and simulation environment since 2016. ExaWind is composed of the incompressible-flow computational-fluid-dynamics (CFD) solvers AMR-Wind and Nalu-Wind and the wind-turbine-dynamics solver OpenFAST. In our hybrid CFD approach, Nalu-Wind unstructured-grid models resolve the near-body flow around the turbine; those models are embedded in, and two-way coupled to, an AMR-Wind structured-grid mesh through overset meshes. In this talk I give an overview of ExaWind software stack and describe how it is being used to address important problems in wind energy.

computational fluid dynamics↗

PORFLOW modeling of Vadose zone flow and transport for the E-area intermediate level vault

In support of the E-Area Performance Assessment, a two-dimensional model of water flow and radionuclide transport through the E-Area Intermediate Level Vault (ILV) and local vadose zone has been developed using the PORFLOWTM software. The purpose of the model is to calculate flux to the water table for radionuclides eluted from the ILV during its operational life, the period of institutional control, and times following site closure. Results of model calculations will be used by a three-dimensional PORFLOW model of transport through the aquifer to determine radionuclide concentrations at a hypothetical 100 meter well and at the site boundary where contaminated groundwater could be assessed by members of the public following site closure. While newly developed, the model structure closely follows that used in the 2008 PA while incorporating a refined computational mesh, updated material properties for the vadose zone soil and vault concrete, revised infiltration rates, and new solid-liquid distribution coefficients. The model also addresses degradation of concrete hydraulic properties by blending soil and concrete water retention curves over a 500 year period. That is, the hydraulic properties of ILV concrete start out as fresh concrete at the time of site closure and degrade to soil properties over a 500 year time period. This approach has not been used previously in E-Area PA’s. The model has been used to calculate water flow through the ILV vadose zone and, on a trial basis, transport of a limited number of radionuclides from the waste region inside the ILV to the water table. Figure ES-1 provides a view of the model and an example of water flow after the concrete has substantially degraded. Figure dimensions are in centimeters. The red area in the left hand side figure is the waste disposal region within the ILV. Colored bands in the figures indicate different soil and concrete regions. Figure ES-2 shows a calculation of flux to the water table (mol/yr) for U-234 and its one-year half-life decay chain (U-234 → Th-230 → Ra-226 → Pb-210). Pb-210 flux is too small to show on the same scale used for Th-230 and Ra-226 in Figure ES-2. The model has also been used to make a preliminary evaluation of the release of tritium from TPBAR disposal containers that will be place in the ILV. A separately calculated tritium release rate as a function of time was used as a source in the PORFLOW model. The TPBAR disposal schedule and tritium release rate differ from the values used in the 2008 PA. Results from these initial trial runs are compared to calculations made for the 2008 PA ILV analysis. In brief, a new PORFLOW model of flow and transport through the ILV vadose zone has been developed and tested. The model is ready to be used for PA calculations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Distributed Sapphire Fiber Bragg Gratings Based Thermal Profiling of Submerged Entry Nozzles

This research focuses on the application of sapphire fiber Bragg gratings (FBGs) for instrumentation in submerged entry nozzles (SEN) within the steelmaking industry. The SEN is pivotal for transferring molten steel from a tundish to a mold, while preventing the infiltration of oxygen and nitrogen from the surrounding environment. Maintaining optimal flow conditions in the mold is crucial for ensuring casting process stability and maintaining high quality steel. Sapphire FBG sensors have been instrumented in SENs to enable distributed thermal mapping for monitoring the health of the SEN. The optical sensor comprises three cascaded sapphire FBGs inscribed using femtosecond laser technology into a one-meter-long sapphire crystalline fiber. The sensor underwent characterization in a laboratory setting up to 1600°C and was tested for long-term stability over 40 hours under extreme environmental conditions. The coupling between silica and sapphire fibers was investigated and implemented during sensor packaging. Here, the sensor successfully captured the pre-heat sequence of the SEN in real-world steelmaking operations. Compared to conventional thermocouples, sapphire FBG sensors demonstrated exceptional efficiency and precision. They offer potential benefits such as increased productivity, reduced energy consumption, and minimized carbon footprint in the steel industry.

Sapphire Fiber Bragg Grating↗

Electrical meter probe contact verification system

A system and method verifies continuity with and measures voltage across a circuit under test (in some instances simultaneously) using two or more test probes. Two or more probe continuity circuits measure continuity through the test probes by injecting a test current through and measuring a processed test current received at each of the plurality of test probes. The probe continuity circuits measure the respective processed test current rendered by the test current flowing through the test circuit at each test probe. A voltmeter measures the potential difference across the test probes.

42 ENGINEERING↗

An intercomparison of wall fluxes in a turbulent thermal convection chamber: Direct numerical simulations and wall-modeled large-eddy simulations enhanced by machine learning

Thermal convection in a closed chamber is driven by a warm bottom, a cold top, and side walls at various temperatures. Although wall fluxes are the source of convection energy, accurately modeling these fluxes (i.e., the wall model) is challenging. In large-eddy simulations (LESs), many wall models are traditionally derived from the canonical boundary layer, which may be unsuitable for thermal convection bounded by both horizontal and vertical walls. This study conducts a model intercomparison of dry convection in a cubic-meter chamber using three direct numerical simulations (DNSs) and four LESs with different wall models. The LESs employ traditional wall models, a new wall model employing physics-aware neural networks, and a refined grid near the walls. The experiment involves four cases with varying sidewall temperatures. Our results show that LESs capture the main flow features and the trends of mean fluxes. The physics-aware neural networks and refined wall grids can improve the temporally averaged local fluxes when the large-scale circulation has a preferred direction. Even without the local improvement of wall fluxes, the LES flow quantities (temperature and velocities) can still largely match those in DNSs, provided the mean flux largely matches the DNSs. Additionally, DNSs reveal that a variation in corner treatments has minimal impacts on the flow quantities away from corners. Finally, LESs underestimate the mean fluxes of the entire wall due to their inability to resolve corner regions, but their mean flux away from the corner can better match DNS.

54 ENVIRONMENTAL SCIENCES↗

Deglaciation of northwestern Greenland during Marine Isotope Stage 11

Past interglacial climates with smaller ice sheets offer analogs for ice sheet response to future warming and contributions to sea level rise; however, well-dated geologic records from formerly ice-free areas are rare. Here we report that subglacial sediment from the Camp Century ice core preserves direct evidence that northwestern Greenland was ice free during the Marine Isotope Stage (MIS) 11 interglacial. Luminescence dating shows that sediment just beneath the ice sheet was deposited by flowing water in an ice-free environment 416 ± 38 thousand years ago. Provenance analyses and cosmogenic nuclide data and calculations suggest the sediment was reworked from local materials and exposed at the surface <16 thousand years before deposition. Ice sheet modeling indicates that ice-free conditions at Camp Century require at least 1.4 meters of sea level equivalent contribution from the Greenland Ice Sheet.

58 GEOSCIENCES↗

Electrical monitoring of saline tracers to reveal subsurface flow pathways in a flat ditch-drained field

Time-lapse electrical resistivity imaging (ERI) combined with salt tracers can enhance our understanding of subsurface flow and transport in ditch-drained agroecosystems. In a nearly level field adjacent to a drainage ditch, we installed 192 electrodes in a 72-m2 plot along with five hydrometric stations to enable time-lapse ERI monitoring during storms. Immediately prior to a wintertime rainstorm, we applied 5 kg of KBr to a shallow trench located roughly 11 m upgradient from the ditch. Antecedent conditions prior to the storm were wet, assuring a hydrologically connected state that favored tracer dissolution and movement in the subsurface. We monitored the evolution of the tracer plume with ERI over a seven-day period. Four-dimensional (4D) delineation of precipitation and tracer transport using time-lapse ERI showed that the tracer plume moved preferentially downward through a discontinuity in the argillic horizon within the first 57 hrs. Over the following 79 hrs, the tracer plume exhibited steady, lateral movement towards the drainage ditch within a more permeable sandy horizon situated just below the argillic. A spatial moment analysis of logarithmic changes in conductivity in the sand layer revealed seepage velocities ranging from 0.0027 to 0.0482 m d-1; these values were positively correlated with hydraulic gradients, suggesting laminar flow processes typical of sandy aquifers. Increasing groundwater velocities with hydraulic gradients suggest that solute transfers from groundwater to ditch are likely to be faster in storms, especially during wet periods. Even so, predominantly slow lateral transport within the sandy horizon, even during storms, indicates that critical source areas of pollutant loss are likely within a few meters of the ditch.

Robinson, Judith L.↗

Monitoring Preferential Flow of Water in Sand Using Thermoacoustics Wave Imaging

Abstract Accurate predictions of fluid flow, mass transport, and reaction rates critically impact the efficiency and reliability of subsurface exploration and sustainable use of subsurface resources. Quantitative dynamical sensing and imaging can play a pivotal role in the ability to make such predictions. Geophysical thermoacoustic technology has the potential to provide the aforementioned capabilities, since it builds upon the principle that electromagnetic and mechanical wave fields can be coupled through a thermodynamic process. In this letter, we present laboratory experiments featuring the efficacy of thermoacoustic imaging in the monitoring of preferential flow of water in porous media. Our laboratory experimental equipment can be readily packaged in a form factor that fits in a borehole, and the use of multiple acoustic transducers—which can be combined with volumetric coding techniques—has the potential to provide quasi‐real‐time imaging (0.5 Hz video rate) of regions in close proximity (a few meters) of an open field well.

Geology↗

The Snow Albedo Evolution (SALVO) Campaign at the North Slope of Alaska Field Campaign Report

The springtime surface-albedo transition in the Alaskan Arctic, along with the forces that determine its duration and nature, was the focus of the Snow ALbedo eVOlution (SALVO) campaign. The SALVO team investigated the reasons and durations of the stages of spring melt, during which albedo values decrease from 0.8 to 0.1, signifying the year’s largest and most significant radiative energy change. SALVO II (2022, 2024) built on findings from the successful SALVO I (2019) melt season campaign and previous research on the melt transition period conducted by Grenfell and Perovich (2004). SALVO used the ARM NSA observatory, thus aligning with a core principle of the ARM Decadal Vision to “provide comprehensive and impactful field measurements to support scientific advancement of atmospheric process understanding.” SALVO fieldwork was conducted in the spring near the ARM NSA Central Facility in Utqiagvik, Alaska (Figure 1). Comprehensive data sets were collected in 2019, 2022, and 2024, which included spectral and broadband albedos, snow and meltwater depths, snow stratigraphy, snow grain size data, and aerial imagery. In April of each project year, before the snow began to melt, we established survey lines at three or four locations: inland tundra at NSA E12, coastal tundra at the NSA C1 site, Elson Lagoon, and offshore on the Chukchi Sea sea ice (2022 only). We set up a 200-meter-long line, marked every five meters, to enable repeated measurements of surface albedo and snow depth at each location. During most site visits, the SALVO II team dug at least one snow pit to assess the characteristics of the vertical snow layers, including the types and sizes of snow grains, snow density, and the distribution of liquid water. We evaluated the characteristics of flowing or pooled water at the bottom of the snowpack. Watching snow melt in the Arctic has been compared by some to being as exciting as watching paint dry, but it is far more exciting and dynamic than that. Initially, changes happen slowly while the snow cover remains above 80%, but then reductions in the albedo of the landscape, from about 0.8 to 0.4, combined with rising spring temperatures, begin to accelerate the melt. It happens so quickly that no matter how hard the field team works, they cannot keep up with documenting the changes. At first, liquid water is scarce—only a few wet layers of snow in the snowpack. But then, water becomes ubiquitous, transporting melt energy and creating an extremely heterogeneous albedo and melt landscape. At the end of each field season, the SALVO team is exhausted, relieved to see the snow gone, and joyful to play in the melt ponds on the sea ice under the midnight sun. Overall, the 2024 SALVO field campaign was a highlight, reflecting numerous lessons learned from 2019 and 2022. Daily measurements were taken more than 10 times at each site, resulting in a comprehensive time series of snow conditions and albedo. The team deployed using snowmachines and then on foot when snowmachine travel was no longer permitted on the melting tundra. Instrument mounts and packaging were optimized for quick deployment, regardless of the mode of transportation.

54 ENVIRONMENTAL SCIENCES↗

An intelligent energy router for managing behind-the-meter resources and assets

With increase in distributed energy resources (DERs) and smart loads, each energy resource and load need a separate power conversion system leading to complex coordination and interaction, reduced energy conversion efficiency, coordinating compliance to grid standards (IEEE 1547) from multiple sources, reduced security. Also, multiple vendors with legacy system designs and proprietary communications interfaces result in redundancy and increase in cost of power electronics systems. This paper presents an energy router concept for buildings applications which provides autonomous power flow between sources and loads with a novel agent-based software interface.

Chinthavali, Madhu Sudhan↗

Real-time Optimal Dispatch of Behind-the-Meter DERs for Secondary Frequency Regulation

Active distribution networks (ADNs) can provide grid services such as peak load shaving, loss reduction, VoltNar control, congestion management, and frequency regulation. The fast response of inverter-based distributed energy resources (DERs) and battery storage systems enables them to provide ramping support and frequency control. This paper proposes a real-time optimization approach for behind-the-meter DERs to participate in the secondary frequency regulation. The proposed approach determines optimal set-points of output power of DERs to respond to requests from system operators (SOs) in realtime to maintain the frequency of the system at the nominal value. To satisfy the real-time requirement for the secondary frequency control, the nonlinear AC power flow model is linearized considering power losses in the system to achieve both high computational speed and acceptable accuracy. The optimization problem is rerun in a closed loop manner until the mismatch between the requested power by the system operators and actual delivered power at the substation reaches an acceptable tolerance. Furthermore, the proposed approach is validated using modified versions of the IEEE 33-bus and IEEE 69-bus distribution systems. Although the contribution of a single distribution system in the frequency regulation may not be significant, stacked and coordinated contributions from several distribution systems can provide frequency regulation and other grid services at scale.

24 POWER TRANSMISSION AND DISTRIBUTION↗

WIPP Safety Significant Confinement Ventilation System (SSCVS) HEPA Filtration System - 20165

Construction and major equipment fabrication are underway for a new ventilation exhaust system at the Waste Isolation Pilot Plant (WIPP). The new system will provide continuous High Efficiency Particulate Air (HEPA) filtration of the exhaust from the WIPP underground while meeting the ventilation demands for expanded waste emplacement and mining operations over the next 40 years. The integrated system design provides for reducing the salt, clay and diesel particulates from the exhaust airflow from the mine, prior to full filtration using Nuclear Safety Significant HEPA filters. The SSCVS design and equipment provides for continuous HEPA filtration over a wide range of operating and environmental conditions. The new exhaust system connects to the existing underground exhaust shaft, and the exhaust air flows from the underground through Salt Reduction Units (SRUs) to protect the final filter banks from excessive moisture and rapid salt/dust buildup. Each of the six (6) SRUs consists of a demister to remove entrained moisture, a dry salt remover unit to filter approximately 90% of the entrained salt/dust, and an automated water treatment system to periodically clean the demisters and to remove salt from the SRU filters. At the maximum expected exhaust flowrate of 540,000 Cubic Feet per Minute (CFM) / 255 Cubic Meters per Second (m{sup 3}/s), five (5) salt removal units will be in operation with one unit in standby or maintenance. An in-line variable frequency drive booster fan will offset pressure losses through each SRU and reduce the relative humidity of the air exiting the SRUs. In the event of a high radiation alarm from the underground Continuous Air Monitors (CAMs), the SRUs will be automatically bypassed, which places the SRS and building outside of the Safety Significant confinement boundary. From the SRUs, the exhaust is directed to the HEPA filter banks located in the New Filter Building. The exhaust system is designed to provide continuous HEPA filtration prior to release to the exhaust stack. There are 22 HEPA filter banks rated at 27,000 CFM / 12.75 m{sup 3}/s each. Each filter bank has two stages of pre-filters and two stages of HEPA filters. The filtered air from each of the 22 filter banks discharges into a common concrete plenum, which is maintained under a negative pressure by the main exhaust fans. Six 1,000 HP variable frequency drive exhaust fans are provided on the south side of the plenum. At the maximum expected exhaust flow of 540,000 CFM, four exhaust fans and twenty filter banks will be in operation. The fans discharge vertically to a separate concrete exhaust plenum. The filtered exhaust is routed from the exhaust plenum to a 125-foot-tall exhaust stack via a 13-foot diameter duct. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Voltage Calculations in Secondary Distribution Networks via Physics-Inspired Neural Network Using Smart Meter Data

The increasing penetration of distributed energy resources (DERs) leads to voltage issues across distribution networks, necessitating voltage calculations by utilities. Electric model-free voltage calculation offers an enticing solution. However, most researches mainly focus on primary distribution networks ignoring secondary distribution networks and commonly overlook extreme voltage case calculations, which require the model’s extrapolation abilities. Here, in addressing the gaps, this paper presents a customized physics-inspired neural network (PINN) model, the structure of which is inspired by the derived coupled power flow model of primary-secondary distribution networks. To ensure precision and rapid convergence, a crafted training framework for the PINN model is proposed. The PINN’s “structure-mimetic” design enables superior extrapolation for unseen scenarios and enhances physical information awareness. We demonstrate this through two applications: hosting capacity analysis and customer-transformer connectivity. The effectiveness and advantages of the proposed PINN model are validated on two public testing systems and one utility distribution feeder model.

Distribution network↗

Least-cost Optimal Distribution Grid Expansion (LODGE) v1

LODGE finds the least-cost portfolio of traditional distribution system upgrades to integrate new loads and behind-the-meter DERs in combination with advanced non-wire alternative (NWA) planning solutions, such as utility-owned storage and distributed PV. Working with a set of least-cost solutions per feeder/substation allows us to benchmark and compare techno-economic performance of different traditional and NWA planning solutions. An important aspect of the LODGE model is that it includes power flow operation constraints. This means that the least-cost planning solutions delivered by LODGE are technically feasible. Available projects in LODGE portfolio include: 1) feeder reconductoring; 2) transformers upgrades; 3) non-wire alternatives, such as strategic siting and sizing of storage and distributed PV; 4) voltage regulators.

Heleno, Miguel↗

Developments on two lithium vapor-box linear test-stand experiments

The lithium vapor-box divertor is a possible fusion power exhaust solution.It uses condensation pumping to create a gradient of vapor density in a divertor slot; this should allow a stable detachment front without active feedback.As initial explorations of the concept, two test stands which take the form of three connected cylindrical stainless steel boxes are being developed: one without plasma at PPPL, to test models of lithium evaporation and flow; and one for the linear plasma device Magnum-PSI (at DIFFER in Eindhoven, The Netherlands) to test the ability of a lithium vapor cloud to induce volumetric detachment and redistribute the plasma power.The first experiment uses boxes with diameters of 6 cm, joined by apertures with diameters of 2.2 cm. Up to 1 g of Li is placed in one box, which is heated to up to 600 degrees C. The Li evaporates, then flows to and condenses in the two other, cooler boxes over several minutes. The quantity of Li transported is assessed by weighing the boxes before and after the heating cycle, and is compared to the quantity predicted to flow for the box at its measured temperature using a Direct Simulation Monte Carlo code, SPARTA. With good experimental conditions, the two values agree to within 15%.The experiment on Magnum-PSI is in the conceptual design stage.The design is assessed by simulations using the code B2.5-Eunomia.They show that when the hydrogen-ion plasma beam, with n_e = 4e20 per cubic meter, T_e = 1.5 eV, and r = 1 cm, is passed through a 16 cm long, 12 Pa, 625 degree C Li vapor cloud, the plasma heat flux and pressure on the target are significantly reduced compared to the case without Li.With the Li present, the plasma is cooled by excitation of Li neutrals followed by radiation until it volumetrically recombines, lowering the heat flux from 3.7 MW/m^2 to 0.13 MW/m^2, and the pressure is reduced by 93%, largely by collisions of hydrogen ions with neutral Li.

divertor↗

A percolating path to green iron

About 1.9 gigatons of steel is produced every year, emitting 8% (3.6 gigatons) of global CO 2 in the process. More than 50% of the CO 2 emissions come from a single step of steel production, known as ironmaking. Hydrogen- based direct reduction (HyDR) of iron oxide to iron has emerged as an emission-free ironmaking alternative. However, multiple physical and chemical phenomena ranging from nanometers to meters inside HyDR reactors alter the microstructure and pore networks in iron oxide pellets, in ways that resist gaseous transport of H 2 /H 2 O, slow reaction rates, and disrupt continuous reactor operation. Using synchrotron nano X-ray computed tomography and percolation theory, we quantify the evolution of pores in iron oxide pellets and demonstrate how nanoscale pore connectivity influences micro- and macroscale flow properties such as permeability, diffusivity, and tortuosity. Our modeling framework connects disparate scales and offers opportunities to accelerate HyDR.

hydrogen↗

Helium-3 Piping and Gas Handling Implementation for the Colossus milli-Kelvin Platform at Fermilab

Colossus is a large millikelvin platform that has a two-meter diameter mixing chamber plate. This uniquely large millikelvin platform utilizes a cryogenics plant to maintain progressively lower temperatures at each of the three upper stages and precool the lower three stages of the system. At the millikelvin stages, Colossus employs multiple commercially available dilution units to achieve millikelvin temperatures at the 100 mK and 20 mK stages. The incoming helium-3/helum-4 process fluid mixture for each dilution unit flows through tubes wrapped around copper posts attached to each of the upper stages of the system. These tubes function as capillary heat exchanger to reduce the temperature of the incoming helium mixture to the appropriate temperature at each stage.

James, C.↗