Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “field deployment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Enabling Autonomous Electron Microscopy for Networked Computation and Steering

Advanced electron microscopy workflows require an ecosystem of microscope instruments and computing systems possibly located at different sites to conduct remotely steered and automated experiments. Current workflow executions involve manual operations for steering and measurement tasks, which are typically performed from control workstations co-located with microscopes; consequently, their operational tempo and effectiveness are limited. We propose an approach based on separate data and control channels for such an ecosystem of Scanning Transmission Electron Microscopes (STEM) and computing systems, for which no general solutions presently exist, unlike the neutron and light source instruments. We demonstrate automated measurement transfers and remote steering of Nion STEM physical instruments over site networks. We propose a Virtual Infrastructure Twin (VIT) of this ecosystem, which is used to develop and test our steering software modules without requiring access to the physical instrument infrastructure. Additionally, we develop a VIT for a multiple laboratory scenario, which illustrates the applicability of this approach to ecosystems connected over wide-area networks, for the development and testing of software modules and their later field deployment.

Al Najjar, Anees↗

Interoperable, Inverter - Based Distributed Energy Resources Enable 100% Renewable and Resilient Utility Microgrids

As microgrids transition away from use of conventional generating resources and increasingly rely on renewable resources towards decarbonization goals, it is crucial to evaluate the capability inverter-based resources to provide microgrid stability and resilience. Particularly, microgrids with a high contribution of intermittent solar photo voltaic generation and higher load variability present unique challenges requiring fast voltage and frequency support. At the San Diego Gas & Electric Company(R) (SDG&E(R)) Borrego Springs Microgrid, a battery inverter was upgraded with grid-forming (GFM) capability to serve as island leader, transitioning responsibility away from diesel generators. An interoperable microgrid control scheme was developed, coordinating GFM and grid-following (GFL) inverters. Hardware-in-the-loop (HIL) simulations using relevant power and controller HIL interfaces between real-time simulators and field equipment are being conducted to de-risk field deployment.

battery energy storage↗

Resilient Inverter-Driven Black Start with Collective Parallel Grid-Forming Operation

As modern power systems are experiencing exceptional changes with increasing penetrations of inverter-based resources (IBRs), system restoration using IBRs has received attention. Using local grid-forming (GFM) assets near consumers, engineered to establish grid voltages in the absence of a stiff grid, i.e., bottom-up restoration, a distribution system could obtain high system resilience by not relying on the bulk power system restoration, which requires significant human intervention and procedure. This paper studies the technical feasibility of the novel approach with detailed electromagnetic transient (EMT) simulations. To thoroughly evaluate the potential of GFM inverters and the technical challenges in IBR-driven black start, a detailed three-phase inverter model is developed, including negative-sequence control for voltage balance and a phase-by- phase current limiter to sustain momentary overloading during the black start. To examine dynamic aspects of the black-start process, the EMT simulation also models transformer and motor dynamics to emulate their inrush and startup behaviors as well as network dynamics. In addition, active involvement of grid- following distributed energy resources is also studied to facilitate the black-start process. By allowing multiple GFM inverters to collectively black start without leader-follower coordination, we demonstrate that a system can achieve high resilience even with a fraction of assets lost. Two test cases of inverter-driven black start, using two and one GFM inverters, respectively, for a heavily unbalanced 2-MVA distribution feeder are demonstrated. Takeaways for further study and field deployment are provided.

grid-forming inverter↗

Performance Evaluation of Data-Enhanced Hierarchical Control for Grid Operations

This paper presents a hardware-in-the-loop (HIL) simulation to evaluate the performance of voltage regulation of Data-Enhanced Hierarchical Control (DEHC). This DEHC uses an advanced distribution management system (ADMS) for grid operations to control legacy and grid-edge devices and coordinate with distributed energy management systems (DERMS) to manage high penetrations of photovoltaics (PV) on a utility distribution system. The HIL platform provides realistic laboratory testing, including accurate modeling (legacy devices, grid-edge devices, and PV) of the real-world distribution system from a utility partner, a real controller (ADMS), software controller DERMS, hardware grid-edge devices, and standard communications protocols. The test results demonstrate functionalities of the integrated platform and the performance of voltage regulation of the coordinated control systems. Based on laboratory testing, the utility can set up the same grid-automation system to manage DERs, legacy devices, and grid-edge devices to achieve their system-level control and operation objectives (e.g., voltage regulation), thus de-risking potential issues such as instability for field deployment.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Hardware-in-the-Loop Testing of Wide-Area Damping Controller for Field Implementation in Large-scale Power Grid

In our previous work, an adaptive measurement-driven wide-area damping controller (WADC) for suppressing inter-area oscillations has been proposed and a hardware prototype was developed and validated through hardware-in-the-loop tests. As a continuation of the work, this paper introduces a WADC software prototype to handle the realistic challenges for field implementation in the control room of the power grid. The WADC software is developed and operated as an openPDC adapter with a graphical user interface (GUI) to monitor the WADC inputs and output, the communication delays and other variables. The software prototype has been fully tested through an enhanced hardware-in-the-loop (HIL) test setup. Its performance is verified under various realistic communication uncertainties, such as random time delays and data losses, with different communication protocols. The experiment results have proven the WADC software can deliver sufficient damping to suppress the targeted oscillation mode in handling various communication uncertainties for future field deployment.

Jia, Xinlan↗

Hardware-in-the-Loop Evaluation for Potential High Limit Estimation-Based PV Plant Active Control

This paper validates the efficacy of an artificial intelligence (AI)-based photovoltaic (PV) plant control and optimization approach in enabling PV plants as accountable grid reliability service providers. The validation is performed in a realistic laboratory controller-hardware-in-the-loop environment, leveraging accurate PV plant modeling and standard industrial communication protocols. Through simulations that account for diverse weather conditions and active control scenarios, the results highlight the superior performance of the AI-based solution in comparison to a state-of-the-art reference-control grouping-based approach. Such a finding contributes to mitigating the risk of overcurtailment and uninstructed deviations of active PV plant controls, and offers practical guidance for its field deployment. Furthermore, it establishes a standardized testing framework for comparing various PV active control strategies.

hardware-in-the-loop↗

Remote Hardware-in-the-Loop Approach for Microgrid Controller Evaluation

Utilities have been installing microgrids because of the increased resilience and reliability advantages they may provide to the distribution system. A microgrid controller is a critical component in microgrids. It is of great benefit to derisk the installation of microgrid controllers before field deployment. Hardware-in-the-loop (HIL) testing is used by controller developers and utilities to evaluate the controllers under stressful conditions. In this work, a microgrid control function developed by the Synchrophasor Grid Monitoring and Automation (SyGMA) laboratory at the University of California, San Diego is tested in a remote HIL (RHIL) setup. The digital real-time simulation of the detailed microgrid system was operated at the National Renewable Energy Laboratory's Energy Systems Integration Facility. Under such RHIL setup, successful controller operation is contingent on understanding and characterizing the communications channel and in particular network latencies. The novelty of this paper is the proposed use of a RHIL setup that leverages existing power system communications protocols to evaluate the controller in conjunction with the simulation capabilities of a remote facility. The work presented here will provide the complete setup of the HIL evaluation platform, the details of the communications protocols used by the setup for data transfer between the two organizations, test cases developed to evaluate the controller, and the results from the experiments.

controller hardware-in-the-loop↗

Comparison of PID Shunting in Polycrystalline and Single-Crystal Silicon Modules via Multi-Scale, Multi-Technique Characterization

We used the methods we reported last year to investigate potential-induced degradation (PID). We have now applied these methods to single-crystalline silicon modules that have degraded during field deployment, as well as in minimodules stressed in the laboratory. We will compare these results to the polycrystalline results presented last year. Small cores have been removed from the modules and subjected to analysis. We use a combination of photoluminescence and dark lock-in thermography imaging, laser marking, electron-beam induced current measurements, and subsequent focused ion-beam marking to allow analysis of individual defects via time-of-flight secondary-ion mass spectrometry (TOF-SIMS) to investigate the root-cause mechanism for PID shunting. We see a direct correlation between recombination active shunts and sodium content. The sodium content in shunted areas peaks at the SiN/Si interface and is consistently observed at a concentration of 0.1%-1% in shunted areas. TOF-SIMS data taken on degraded and non-degraded single-crystalline sample areas show a similar trend as in the polycrystalline samples: more sodium is seen in the degraded areas.

14 SOLAR ENERGY↗

PV Inverter Testing for Momentary Cessation and Rate-of-Change-of-Frequency Events

To understand the power system stability and develop better electromagnetic transient (EMT) models of field deployed photovoltaic (PV) inverters, it is important to characterize inverters' response to abnormal voltage and frequency scenarios. Because EMT models are not typically available for small distribution-connected PV inverters, and because inerterconnection standards historically did not specify desired ride-through behaviors, we tested two such inverters in the lab to characterize their responses to severe undervoltage events and high rate-of-change-of-frequency (ROCOF) conditions. The inverters tested were pre-IEEE 1547-2018 residential PV inverters widely used in the Hawaiian Electric territory and many other areas. The testing results for undervoltage scenarios showed that the inverter from one vendor exhibited momentary cessation while the inverter from the other vendor did not exhibit momentary cessation behavior or tripping for most of the events below the 120 ms undervoltage trip threshold duration set by IEEE 1547-2003. The testing results for ROCOF scenarios showed that the inverter from one vendor temporarily lost synchronization during ROCOF conditions while the inverter from the other vendor did not lose synchronization or cease generation for any ROCOF conditions. Both the inverters were also tested for EMT-simulated grid events with severe changes in frequency and voltage. The observed responses of the inverters were different from the simulated response of PV inverters represented the best available assumptions from pre-existing information. The results from these experiments can be used to update the inverter models used in bulk power system studies.

aggregates↗

Distributed Intrusion Detection System using Semantic-based Rules for SCADA in Smart Grid

Cyber-physical system (CPS) security for the smart grid enables secure communication for the SCADA and wide-area measurement system data. Power utilities world-wide use various SCADA protocols, namely DNP3, Modbus, and IEC 61850, for the data exchanges across substation field devices, remote terminal units (RTUs), and control center applications. Adversaries may exploit compromised SCADA protocols for the reconnaissance, data exfiltration, vulnerability assessment, and injection of stealthy cyberattacks to affect power system operation. In this paper, we propose an efficient algorithm to generate robust rule sets. We integrate the rule sets into an intrusion detection system (IDS), which continuously monitors the DNP3 data traffic at a substation network and detects intrusions and anomalies in real-time. To enable CPS-aware wide-area situational awareness, we integrated the methodology into an open-source distributed-IDS (D-IDS) framework. The D-IDS facilitates central monitoring of the detected anomalies from the geographically distributed substations and to the control center. The proposed algorithm provides an optimal solution to detect network intrusions and abnormal behavior. Different types of IDS rules based on packet payload, packet flow, and time threshold are generated. Further, IDS testing and evaluation is performed with a set of rules in different sequences. The detection time is measured for different IDS rules, and the results are plotted. All the experiments are conducted at Power Cyber Lab, Iowa State University, for multiple power grid models. After successful testing and evaluation, knowledge and implementation are transferred to field deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Iterative Reconstruction for Multimodal Neutron Tomography

Here, we describe a unified framework for model-based iterative 3-D reconstruction of multimodal neutron transmission, hydrogen-scatter, and induced-fission images from low resolution data recorded using 14.1-MeV neutrons and the associated-particle imaging (API) technique. The framework, which was developed to facilitate use in challenging field-deployment scenarios, is centered around physics-based system models and a total variation (TV) constrained implementation of the simultaneous iterative reconstruction technique (SIRT). Modified to solve a statistically weighted least squares (WLS) problem, the SIRT algorithm is accelerated using ordered subsets and Nesterov’s momentum for which we derive a near-optimal value of the governing Lipschitz constant. The approach enables the reconstruction of images that are high resolution compared to the acquired data and is robust to both limited statistics and a limited number of projection angles. Moreover, the framework is fast enough to be practical. Example images are provided that demonstrate both the ability to perform fast-neutron imaging of high-atomic-number materials with low radiation dose and the benefit of multimodal neutron imaging to identify key materials.

Hydrogen scatter↗

Neutron and Gamma-Ray Imaging of Th-232 and Cm-244 Using Organic Glass Scintillators

Modern nuclear safeguards require detection and characterization capabilities suitable for a wide variety of radiation sources and applications. Field-deployable detection systems have also had to modernize to meet changing needs. Recent developments in organic scintillator technology have resulted in the creation of an organic glass scintillator (OGS) at Sandia National Laboratory which is composed of a 9:1 mixture of glass compounds C42H36Si and C51H44Si. The novel scintillator composition was implemented into the design for a dual-particle capable imaging system at the University of Michigan. This work presents new results from two experiments demonstrating the gamma-ray and fast-neutron imaging capabilities of the organic glass system. Gamma spectroscopy was also performed using CeBr3 scintillators that are part of the imager design. Measurements were performed at Lawrence Livermore National Laboratory using 232Th metal hemishells and an encapsulated 244Cm oxide source. Successful gamma-ray imaging of the 232Th distributed sources is demonstrated with the glass imager, but there were no appreciable neutrons from the 232Th for neutron imaging. Promising neutron and gamma-ray imaging results of 244Cm are demonstrated despite limited imaging event statistics available in this measurement. Gamma-ray spectroscopy results were able to identify 232Th using prominent emissions at 239, 338, 583, and 911 keV. 244Cm was identified from emissions of 43, 99, and 153 keV. These results demonstrate the potential of organic glass imaging for nuclear nonproliferation or characterization efforts.

Lopez, Ricardo [Univ. of Michigan, Ann Arbor, MI (↗

MAPSTER

MAPSTER Observer is a light-weight software package that can be installed on field deployed computers which automatically manages data and creates metadata packages designed to organize large datasets, making them easy to retrieve and share.

Larson, MatthewD↗

Random forest models accurately classify synthetic opioids using high-dimensionality mass spectrometry datasets

Detection of novel threat agents presents several challenges, a principle one being the development of untargeted methods to screen an increasing number of threat chemicals whose exact structures are unknown. With the use of Machine Learning (ML) tools, we can guide the development of analytical methods for broad-spectrum detection of unbounded threat chemical families in complex mixtures. Toward this goal, we used nominal mass and high-resolution mass spectrometry data for hundreds of synthetic opioids and non-opioid compounds. We tested two ML techniques, logistic regression and random forest, to develop models towards a practical, implementable method for opioid detection. We found that of these tested ML methods, random forest models resulted in the highest validation accuracy (95+%) for both nominal mass and high-resolution classification of opioids versus non-opioids, with low false positive and false negative rates. The RF models were then used to successfully predict the classification of 10 compounds—five opioids and five non-opioids not part of the training and validation analysis. This application of ML is a critical step towards the development of field-deployable nominal mass spectrometers with ML-driven analyses for classification of emergent threats.

Arasteh, Kourosh [Lawrence Livermore National Labo↗

Implementation of stacked ensemble machine learning for the detection of surrogate plutonium contamination in soil via LIBS

Supervised machine learning methods have demonstrated increased utility for the quantification of lanthanide and actinide elements in atomic spectroscopy applications. This study implements laser-induced breakdown spectroscopy (LIBS) for the identification of plutonium surrogate material (CeO 2 ) in soil matrices by training supervised machine learning methods on the recorded spectral data. A bagged ensemble using Random Forest yields the highest sensitivity predictions with a detection limit of 0.015 wt.% CeO 2 . However, high precision in Ce content prediction required the use of a stacked ensemble regression, which provided the superlative Ce quantification model with an error of 0.107% and a detection limit of 0.022 wt.%. Furthermore, the high performance of the stacked ensemble demonstrates its potential to enhance the accuracy and sensitivity of nuclear contaminant detection using field-deployable spectroscopic analyzers in real-world scenarios.

47 OTHER INSTRUMENTATION↗

Tracking ebolavirus genomic drift with a resequencing microarray

Filoviruses are emerging pathogens that cause acute fever with high fatality rate and present a global public health threat. During the 2013–2016 Ebola virus outbreak, genome sequencing allowed the study of virus evolution, mutations affecting pathogenicity and infectivity, and tracing the viral spread. In 2018, early sequence identification of the Ebolavirus as EBOV in the Democratic Republic of the Congo supported the use of an Ebola virus vaccine. However, field-deployable sequencing methods are needed to enable a rapid public health response. Resequencing microarrays (RMA) are a targeted method to obtain genomic sequence on clinical specimens rapidly, and sensitively, overcoming the need for extensive bioinformatic analysis. This study presents the design and initial evaluation of an ebolavirus resequencing microarray (Ebolavirus-RMA) system for sequencing the major genomic regions of four Ebolaviruses that cause disease in humans. The design of the Ebolavirus-RMA system is described and evaluated by sequencing repository samples of three Ebolaviruses and two EBOV variants. The ability of the system to identify genetic drift in a replicating virus was achieved by sequencing the ebolavirus glycoprotein gene in a recombinant virus cultured under pressure from a neutralizing antibody. Comparison of the Ebolavirus-RMA results to the Genbank database sequence file with the accession number given for the source RNA and Ebolavirus-RMA results compared to Next Generation Sequence results of the same RNA samples showed up to 99% agreement.

59 BASIC BIOLOGICAL SCIENCES↗