Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “false positive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Synergistic Chem-Bio Detection/Classification Combining UV LIF and IR LIDAR (SV)

The objective of this project was to determine if adding data products from Sandia’s Ares laser-induced fluorescence (LIF) system to those from Lockheed Martin Coherent Technologies’ Prototype WANDER Laser Radar (PROWLR) system produces an overall system with an improved ability to discriminate between aerosol-dispersed surrogates of chemical and biological agents and aerosol-dispersed background materials such as dust and smoke from burning wood, diesel fuel, and other common materials. The results of this work demonstrate that the addition of LIF information to PROWLR information significantly improves discrimination performance with respect to either LIF-only or PROWLR-only performance. The primary improvement is a dramatic improvement in false positive, where the best-performing combination of LIF/PROWLR data products improved false positive performance to 6.4% from 20.6% (PROWLR-only) and 11% (LIF-only). It is important to note that the improvement in false positive performance does not come at the expense of true positive performance which remains high at 93%. Sandia, DOE, and the government have benefitted from this project by building capabilities generating supervised machine learning and also in working closely and building professional relationships with private industry partners. Sandia’s CRADA partner benefitted by utilizing Sandia’s expertise to help accomplish work that will be beneficial to their business prospects in the future by allowing the knowledge gained by the CRADA interaction to provide them with a differentiating capability from potential competitors. The public and taxpayers will ultimately benefit from the knowledge has been gained that can be applied for public safety purposes in terms of producing systems with improved capabilities to detect threats to the public from the deployment of chemical and/or biological weapons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

RADIOISOTOPE IDENTIFICATION OF SHIELDED AND MASKED SNM RDD MATERIALS

Sonar and speech techniques have been investigated to improve functionality and enable handheld and other man-portable, mobile, and portal systems to positively detect and identify illicit nuclear materials, with minimal data and with minimal false positives and false negatives. RadSonar isotope detection and identification is an algorithm development project funded by NA-22 and employing the resources of Savannah River National Laboratory and three University Laboratories (JHU-APL, UT-ARL, and UW-APL). Algorithms have been developed that improve the probability of detection and decrease the number of false positives and negatives. Two algorithms have been developed and tested. The first algorithm uses support vector machine (SVM) classifiers to determine the most prevalent nuclide(s) in a spectrum. It then uses a constrained weighted least squares fit to estimate and remove the contribution of these nuclide(s) to the spectrum, iterating classification and fitting until there is nothing of significance left. If any Special Nuclear Materials (SNMs) were detected in this process, a second tier of more stringent classifiers are used to make the final SNM alert decision. The second algorithm is looking at identifying existing feature sets that would be relevant in the radioisotope identification context. The underlying philosophy here is to identify parallels between the physics and/or the structures present in the data for the two applications (speech analysis and gamma spectroscopy). The expectation is that similar approaches may work in both cases. The mel-frequency cepstral representation of spectra is widely used in speech, particularly for two reasons: approximation of the response of the human ear, and simplicity of channel effect separation (in this context, a 'channel' is a method of signal transport that affects the signal, examples being vocal tract shape, room echoes, and microphone response). Measured and simulated gamma-ray spectra from a hand-held Radioisotope Identification Device were used to evaluate the algorithms. This paper will present and discuss results of the Test and Evaluation performed on two algorithms produced from the project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extracting the Subhalo Mass Function from Strong Lens Images with Image Segmentation

Abstract Detecting substructure within strongly lensed images is a promising route to shed light on the nature of dark matter. However, it is a challenging task, which traditionally requires detailed lens modeling and source reconstruction, taking weeks to analyze each system. We use machine learning to circumvent the need for lens and source modeling and develop a neural network to both locate subhalos in an image as well as determine their mass using the technique of image segmentation. The network is trained on images with a single subhalo located near the Einstein ring across a wide range of apparent source magnitudes. The network is then able to resolve subhalos with masses m ≳ 10 8.5 M ⊙ . Training in this way allows the network to learn the gravitational lensing of light, and, remarkably, it is then able to detect entire populations of substructure, even for locations further away from the Einstein ring than those used in training. Over a wide range of the apparent source magnitude, the false-positive rate is around three false subhalos per 100 images, coming mostly from the lightest detectable subhalo for that signal-to-noise ratio. With good accuracy and a low false-positive rate, counting the number of pixels assigned to each subhalo class over multiple images allows for a measurement of the subhalo mass function (SMF). When measured over three mass bins from 10 9 –10 10 M ⊙ the SMF slope is recovered with an error of 36% for 50 images, and this improves to 10% for 1000 images with Hubble Space Telescope-like noise.

79 ASTRONOMY AND ASTROPHYSICS↗

Tentacle Probes™: Differentiation of Difficult Single-Nucleotide Polymorphisms and Deletions by Presence or Absence of a Signal in Real-Time PCR

Abstract Background: False-positive results are a common problem in real-time PCR identification of DNA sequences that differ from near neighbors by a single-nucleotide polymorphism (SNP) or deletion. Because of a lack of sufficient probe specificity, post-PCR analysis, such as a melting curve, is often required for mutation differentiation. Methods: Tentacle Probes™, cooperative reagents with both a capture and a detection probe based on specific cell-targeting principles, were developed as a replacement for 2 chromosomal TaqMan–minor groove binder (MGB) assays previously developed for Yersinia pestis and Bacillus anthracis detection. We compared TaqMan-MGB probes to Tentacle Probes for SNP and deletion detection based on the presence or absence of a growth curve. Results: With the TaqMan-MGB Y. pestis yp48 assays, false-positive results for Yersinia pseudotuberculosis occurred at every concentration tested, and with the TaqMan-MGB B. anthracis gyrA assays, false-positive results occurred in 21 of 29 boil preps of environmental samples of near neighbors. With Tentacle Probes no false-positive results occurred. Conclusions: The high specificity exhibited by Tentacle Probes may eliminate melting curve analysis for SNP and deletion mutation detection, allowing the diagnostic use of previously difficult targets.

Satterfield, Brent C.↗

MSPI False Indication Probability Simulations

This paper examines false indication probabilities in the context of the Mitigating System Performance Index (MSPI), in order to investigate the pros and cons of different approaches to resolving two coupled issues: (1) sensitivity to the prior distribution used in calculating the Bayesian-corrected unreliability contribution to the MSPI, and (2) whether (in a particular plant configuration) to model the fuel oil transfer pump (FOTP) as a separate component, or integrally to its emergency diesel generator (EDG). False indication probabilities were calculated for the following situations: (1) all component reliability parameters at their baseline values, so that the true indication is green, meaning that an indication of white or above would be false positive; (2) one or more components degraded to the extent that the true indication would be (mid) white, and “false” would be green (negative) or yellow (negative) or red (negative). In key respects, this was the approach taken in NUREG-1753. The prior distributions examined were the constrained noninformative (CNI) prior used currently by the MSPI, a mixture of conjugate priors, the Jeffreys noninformative prior, a nonconjugate log(istic)-normal prior, and the minimally informative prior investigated in (Kelly et al., 2010). The mid-white performance state was set at ?CDF = ?10 ? 10-6/yr. For each simulated time history, a check is made of whether the calculated ?CDF is above or below 10-6/yr. If the parameters were at their baseline values, and ?CDF > 10-6/yr, this is counted as a false positive. Conversely, if one or all of the parameters are set to values corresponding to ?CDF > 10-6/yr but that time history’s ?CDF < 10-6/yr, this is counted as a false negative indication. The false indication (positive or negative) probability is then estimated as the number of false positive or negative counts divided by the number of time histories (100,000). Results are presented for a set of base case parameter values, and three sensitivity cases in which the number of FOTP demands was reduced, along with the Birnbaum importance of the FOTP.

99 GENERAL AND MISCELLANEOUS↗

AUTOMATIC RECOGNITION OF CORONAL TYPE II RADIO BURSTS: THE AUTOMATED RADIO BURST IDENTIFICATION SYSTEM METHOD AND FIRST OBSERVATIONS

Major space weather events such as solar flares and coronal mass ejections are usually accompanied by solar radio bursts, which can potentially be used for real-time space weather forecasts. Type II radio bursts are produced near the local plasma frequency and its harmonic by fast electrons accelerated by a shock wave moving through the corona and solar wind with a typical speed of {approx}1000 km s{sup -1}. The coronal bursts have dynamic spectra with frequency gradually falling with time and durations of several minutes. This Letter presents a new method developed to detect type II coronal radio bursts automatically and describes its implementation in an extended Automated Radio Burst Identification System (ARBIS 2). Preliminary tests of the method with spectra obtained in 2002 show that the performance of the current implementation is quite high, {approx}80%, while the probability of false positives is reasonably low, with one false positive per 100-200 hr for high solar activity and less than one false event per 10000 hr for low solar activity periods. The first automatically detected coronal type II radio burst is also presented.

79 ASTRONOMY AND ASTROPHYSICS↗

Computerized detection of breast cancer on automated breast ultrasound imaging of women with dense breasts

Purpose: Develop a computer-aided detection method and investigate its feasibility for detection of breast cancer in automated 3D ultrasound images of women with dense breasts. Methods: The HIPAA compliant study involved a dataset of volumetric ultrasound image data, “views,” acquired with an automated U-Systems Somo•V{sup ®} ABUS system for 185 asymptomatic women with dense breasts (BI-RADS Composition/Density 3 or 4). For each patient, three whole-breast views (3D image volumes) per breast were acquired. A total of 52 patients had breast cancer (61 cancers), diagnosed through any follow-up at most 365 days after the original screening mammogram. Thirty-one of these patients (32 cancers) had a screening-mammogram with a clinically assigned BI-RADS Assessment Category 1 or 2, i.e., were mammographically negative. All software used for analysis was developed in-house and involved 3 steps: (1) detection of initial tumor candidates, (2) characterization of candidates, and (3) elimination of false-positive candidates. Performance was assessed by calculating the cancer detection sensitivity as a function of the number of “marks” (detections) per view. Results: At a single mark per view, i.e., six marks per patient, the median detection sensitivity by cancer was 50.0% (16/32) ± 6% for patients with a screening mammogram-assigned BI-RADS category 1 or 2—similar to radiologists’ performance sensitivity (49.9%) for this dataset from a prior reader study—and 45.9% (28/61) ± 4% for all patients. Conclusions: Promising detection sensitivity was obtained for the computer on a 3D ultrasound dataset of women with dense breasts at a rate of false-positive detections that may be acceptable for clinical implementation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Poor Predictive Value of Intraoperative Real-Time Dosimetry for Prostate Seed Brachytherapy

Purpose: To identify dosimetric parameters predictive of a good prostate seed I{sup 125} quality implant. We analyzed preimplant and postimplant realtime dosimetry in patients treated with intraoperative (IO) inverse planning. Methods and Materials: We analyzed 127 consecutively treated patients with primarily low-risk prostate carcinoma who underwent prostate permanent seed I{sup 125} brachytherapy using an IO planning approach. The implant was done using the three-dimensional transrectal ultrasound (PRE-TRUS)-guided IO interactive inverse preplanning system. The TRUS was repeated in the operating room after the implant procedure was complete (POST-TRUS). The prostate was recontoured and postimplant dosimetry was calculated. Each patient underwent computed tomography scan on Day 28 (CT-D28) to evaluate implant quality. Area under the receiver operating characteristic curves (AUROC) was evaluated for models predictive of a V100 of {>=}90% and a D90 of {>=}140 Gy on the basis of CT-D28 values. Results: On CT-D28, 72.4% of patients had a V100 of {>=}90% and 74.8% had a D90 of {>=}140 Gy. AUROC for a V100 of {>=}90% was 0.665 (p = 0.004) on PRE-TRUS and 0.619 (p = 0.039) on POST-TRUS. AUROC for D90 of {>=}140 Gy was 0.602 (p = 0.086) on PRE-TRUS and 0.614 (p = 0.054) on POST-TRUS. Using PRE-TRUS V100 cutoff of >97% gives sensitivity of 88% and a false-positive rate of 63%. A POST-TRUS D90 cutoff of >170 Gy resulted in a sensitivity of 62% and a false-positive rate of 34%. Conclusions: Because of unacceptably high false-positive rates, IO preimplant and postimplant TRUS-based dosimetry are not accurate tools to predict for postimplant computed tomography-based dosimetry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Overview of Deployed EDS Technologies And Third Party Involvement with Advancedments

The term explosive detection system (EDS) is used by the TSA to describe equipment that is certified to detect explosives in checked bags. The EDS, as certified, by the TSL must consist of device for interrogating a bag and an automated detection algorithm (ATD) for evaluating the results of the interrogation. We only consider CT as the interrogation device in this report. A schematic drawing of a CT-based EDS is shown in Figure 2. The output of the ATD is the binary decision of alarm or non-alarm. Alarms may true- or false-positives. Non-alarms may be true- or false-negatives. False positives are also denoted false alarms. The true detection means that the ATD reports an alarm when a threat is present in the scanned bag. The probability of detecting a threat given that a threat is present is denoted the probability of detection (PD). The probability of false alarm (PFA) is the case when an alarm is reported when a threat is not present in a bag. Certification in this context means passing tests for PD and PFA at the TSL. The results of the EDS include CT cross-sectional images of the bag and specifics about the alarmed objects generated by ATD. These results are presented on a display so that a person may override the decision of ATD and declare the alarm to be a non-alarm. This process is denoted clearing. Bags that are not cleared by the person are sent to a secondary inspection process. Here the bags may be opened or assessed with explosive trace detection (ETD) in order to clear the bags. Bags that are not cleared at this point are evaluated by an ordinance disposal team. The CT scanner along with ATD is denoted Level 1 screening. The process of clearing on a display is denoted Level 2 screening. Secondary inspection is denoted Level 3 screening. Vendors of the deployed EDSs supply the TSA with equipment for all three levels. Therefore, the term EDS may include the equipment provided for Levels 1, 2 and 3. A schematic diagram of an EDS and the levels of screening are shown in Figure 7. The decision processes used as a bag is scanned and cleared is shown in Figure 8. Shield alarms and exceptions are discussed below. Since most alarms are false alarms, the probability of alarm is oftentimes denoted the probability of a false alarm. The expenses associated with clearing false alarms occur in Levels 2 and 3.

42 ENGINEERING↗

Overview of Deployed EDS Technologies

The term explosive detection system (EDS) is used by the TSA to describe equipment that is certified to detect explosives in checked bags. The EDS, as certified, by the TSL must consist of device for interrogating a bag and an automated detection algorithm (ATD) for evaluating the results of the interrogation. We only consider CT as the interrogation device in this report. A schematic drawing of a CT-based EDS is shown in Figure 2. The output of the ATD is the binary decision of alarm or non-alarm. Alarms may true- or false-positives. Non-alarms may be true- or false-negatives. False positives are also denoted false alarms. The true detection means that the ATD reports an alarm when a threat is present in the scanned bag. The probability of detecting a threat given that a threat is present is denoted the probability of detection (PD). The probability of false alarm (PFA) is the case when an alarm is reported when a threat is not present in a bag. Certification in this context means passing tests for PD and PFA at the TSL. The results of the EDS include CT cross-sectional images of the bag and specifics about the alarmed objects generated by ATD. These results are presented on a display so that a person may override the decision of ATD and declare the alarm to be a non-alarm. This process is denoted clearing. Bags that are not cleared by the person are sent to a secondary inspection process. Here the bags may be opened or assessed with explosive trace detection (ETD) in order to clear the bags. Bags that are not cleared at this point are evaluated by an ordinance disposal team. The CT scanner along with ATD is denoted Level 1 screening. The process of clearing on a display is denoted Level 2 screening. Secondary inspection is denoted Level 3 screening. Vendors of the deployed EDSs supply the TSA with equipment for all three levels. Therefore, the term EDS may include the equipment provided for Levels 1, 2 and 3. A schematic diagram of an EDS and the levels of screening are shown in Figure 7. The decision processes used as a bag is scanned and cleared is shown in Figure 8. Shield alarms and exceptions are discussed below. Since most alarms are false alarms, the probability of alarm is often times denoted the probability of a false alarm. The expenses associated with clearing false alarms occur in Levels 2 and 3.

42 ENGINEERING↗

Tile-Based Fisher-Ratio Software for Improved Feature Selection Analysis of Comprehensive Two-Dimensional Gas Chromatography Time-of-Flight Mass Spectrometry Data

Two-dimensional (2D) gas chromatography coupled with time-of-flight mass spectrometry (GC × GC – TOFMS) is a highly capable instrumental platform that produces complex and information-rich multi-dimensional chemical data. The complex data can be overwhelming, especially when many samples (of various sample classes) are analyzed with multiple injections for each sample. Thus, the data must be analyzed in such a way to extract the most meaningful information. The pixel-based and peak table-based algorithmic use of Fisher ratios has been used successfully in the past to reduce the multi-dimensional data down to those chemical compounds that are changing between classes relative to those that are not (i.e., chemical feature selection). We report on the initial development of a computationally fast novel tile-based Fisher-ratio software that addresses challenges due to 2D retention time misalignment without explicitly aligning the data, which is a problem for both pixel-based and peak table- based methods. Concurrently, the tile-based Fisher-ratio software maximizes the sensitivity contrast of true positives against a background of potential false positives and noise. To study this software, eight compounds, plus one internal standard, were spiked into diesel at various concentrations. The tile-based F-ratio software was able to discover all spiked analytes, within the complex diesel sample matrix with thousands of potential false positives, in each possible concentration comparison, even at the lowest absolute spiked analyte concentration ratio of 1.06.

chemometrics↗

Rescoring Docking Hit Lists for Model Cavity Sites: Predictions And Experimental Testing

Molecular docking computationally screens thousands to millions of organic molecules against protein structures, looking for those with complementary fits. Many approximations are made, often resulting in low 'hit rates'. A strategy to overcome these approximations is to rescore top-ranked docked molecules using a better but slower method. One such is afforded by molecular mechanics-generalized Born surface area (MM-GBSA) techniques. These more physically realistic methods have improved models for solvation and electrostatic interactions and conformational change compared to most docking programs. To investigate MM-GBSA rescoring, we re-ranked docking hit lists in three small buried sites: a hydrophobic cavity that binds apolar ligands, a slightly polar cavity that binds aryl and hydrogen-bonding ligands, and an anionic cavity that binds cationic ligands. These sites are simple; consequently, incorrect predictions can be attributed to particular errors in the method, and many likely ligands may actually be tested. In retrospective calculations, MM-GBSA techniques with binding-site minimization better distinguished the known ligands for each cavity from the known decoys compared to the docking calculation alone. This encouraged us to test rescoring prospectively on molecules that ranked poorly by docking but that ranked well when rescored by MM-GBSA. A total of 33 molecules highly ranked by MM-GBSA for the three cavities were tested experimentally. Of these, 23 were observed to bind-these are docking false negatives rescued by rescoring. The 10 remaining molecules are true negatives by docking and false positives by MM-GBSA. X-ray crystal structures were determined for 21 of these 23 molecules. In many cases, the geometry prediction by MM-GBSA improved the initial docking pose and more closely resembled the crystallographic result; yet in several cases, the rescored geometry failed to capture large conformational changes in the protein. Intriguingly, rescoring not only rescued docking false positives, but also introduced several new false positives into the top-ranking molecules. We consider the origins of the successes and failures in MM-GBSA rescoring in these model cavity sites and the prospects for rescoring in biologically relevant targets.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Focal mass-like cardiac uptake on oncologic FDG PET/CT: Real lesion or atypical pattern of physiologic uptake?

Background: Cardiac uptake on oncologic FDG PET/CT can be unpredictable. Focal or mass-like cardiac uptake not confined to normal pattern is a real challenge for interpretation due to great variability in physiologic uptake and rarity of either primary or metastatic cardiac neoplasms. Methods and Results: Eight patients with suspicious mass-like cardiac uptake on oncologic FDG PET/CT were retrospectively analyzed with correlation to cardiac workups including contrast CT, echocardiography, and repeat PET/CT. Four patients had real cardiac lesions or metastases. Focal uptake was benign and might represent papillary muscle in the other four. SUV{sub max} ratio between the cardiac focus and surrounding background cardiac uptake was statistically higher in the true-positive group than that in the false-positive group. In addition, the patients with true-positive cardiac uptake had more diffuse distant metastases compared to those with false-positive cardiac uptake. Conclusions: Focal suspicious cardiac uptake on oncology FDG PET/CT warranted further evaluation. SUV{sub max} ratio between the cardiac focus and surrounding background cardiac uptake and status of distant metastases might help to differentiate malignant from benign nature of the focal cardiac uptake on FDG PET/CT. Focal uptake of the right ventricle on oncologic FDG PET/CT is more likely suggestive of a neoplasm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Demonstration that Correcting for Completeness and Reliability Is Critical for Robust Occurrence Rates

A measurement of planetary occurrence rates based on a planet catalog should be robust against details of how initial detections were classified as planets or false positives. This is accomplished by supplying the catalog’s rate of missed planets (completeness) and rate of non-planets incorrectly called planets (reliability). The final Kepler data release (DR25) includes products that can be used with the DR25 planet candidate catalog to correct for completeness and reliability in occurrence rate estimates. This is made possible by the Kepler Robovetter, which algorithmically and uniformly selects planets based on a variety of metrics and thresholds. Completeness, reliability, and occurrence rates potentially depend on these Robovetter thresholds. We study the impact of varying these vetting thresholds using the techniques of Bryson et al. 2019 (arXiv:1906.03575). We explore sets of thresholds that result in more or fewer planets (trading off completeness for reliability), as well as thresholds tuned to pass DR25 false positives identified as possible planets by the Kepler False Positive Working Group. We find that when correcting only for completeness, and not reliability, the resulting occurrence rates have a strong dependence on these threshold sets. For example, the value of SAG13 eta-Earth varies by over a factor of 4 when not corrected for reliability. However, when correcting for both completeness and reliability, occurrence rates using our threshold sets are statistically indistinguishable, with differences being well inside 1-sigma error bars. We present occurrence rates integrated over several period-radius ranges. For example, SAG13 eta-Earth is consistent with 0.127 (+0.094)(-0.054) (from Bryson et al. 2019) for all the Robovetter threshold sets. This result emphasizes the importance of correcting occurrence rates for both completeness and reliability. This suggests that inconsistent completeness and reliability correction may be a significant contributor to the large variation of occurrence rates in recent literature. We plan to make the Robovetter results for our threshold sets available, and encourage the community to use them to examine whether other occurrence rate methods yield similarly robust results.

Bryson, S.↗

TU-G-204-09: The Effects of Reduced- Dose Lung Cancer Screening CT On Lung Nodule Detection Using a CAD Algorithm

Purpose: While Lung Cancer Screening CT is being performed at low doses, the purpose of this study was to investigate the effects of further reducing dose on the performance of a CAD nodule-detection algorithm. Methods: We selected 50 cases from our local database of National Lung Screening Trial (NLST) patients for which we had both the image series and the raw CT data from the original scans. All scans were acquired with fixed mAs (25 for standard-sized patients, 40 for large patients) on a 64-slice scanner (Sensation 64, Siemens Healthcare). All images were reconstructed with 1-mm slice thickness, B50 kernel. 10 of the cases had at least one nodule reported on the NLST reader forms. Based on a previously-published technique, we added noise to the raw data to simulate reduced-dose versions of each case at 50% and 25% of the original NLST dose (i.e. approximately 1.0 and 0.5 mGy CTDIvol). For each case at each dose level, the CAD detection algorithm was run and nodules greater than 4 mm in diameter were reported. These CAD results were compared to “truth”, defined as the approximate nodule centroids from the NLST reports. Subject-level mean sensitivities and false-positive rates were calculated for each dose level. Results: The mean sensitivities of the CAD algorithm were 35% at the original dose, 20% at 50% dose, and 42.5% at 25% dose. The false-positive rates, in decreasing-dose order, were 3.7, 2.9, and 10 per case. In certain cases, particularly in larger patients, there were severe photon-starvation artifacts, especially in the apical region due to the high-attenuating shoulders. Conclusion: The detection task was challenging for the CAD algorithm at all dose levels, including the original NLST dose. However, the false-positive rate at 25% dose approximately tripled, suggesting a loss of CAD robustness somewhere between 0.5 and 1.0 mGy. NCI grant U01 CA181156 (Quantitative Imaging Network); Tobacco Related Disease Research Project grant 22RT-0131.

60 APPLIED LIFE SCIENCES↗

Exoplanet Biosignatures: Understanding Oxygen as a Biosignature in the Context of Its Environment

Here we review how environmental context can be used to interpret whether O 2 is a biosignature in extrasolar planetary observations. This paper builds on the overview of current biosignature research discussed in Schwieterman et al. (2017), and provides an in-depth, interdisciplinary example of biosignature identification and observation that serves as a basis for the development of the general framework for biosignature assessment described in Catling et al., (2017). O 2 is a potentially strong biosignature that was originally thought to be an unambiguous indicator for life at high-abundance. In exploring O 2 as a biosignature, we describe the coevolution of life with the early Earth's environment, and how the interplay of sources and sinks in the planetary environment may have resulted in suppression of O 2 release into the atmosphere for several billion years, a false negative for biologically generated O 2 . False positives may also be possible, with recent research showing potential mechanisms in exoplanet environments that may generate relatively high abundances of atmospheric O 2 without a biosphere being present. These studies suggest that planetary characteristics that may enhance false negatives should be considered when selecting targets for biosignature searches. Similarly our ability to interpret O 2 observed in an exoplanetary atmosphere is also crucially dependent on environmental context to rule out false positive mechanisms. We describe future photometric, spectroscopic and time-dependent observations of O 2 and the planetary environment that could increase our confidence that any observed O 2 is a biosignature, and help discriminate it from potential false positives. The rich, interdisciplinary study of O 2 illustrates how a synthesis of our understanding of life's evolution and the early Earth, scientific computer modeling of star-planet interactions and predictive observations can enhance our understanding of biosignatures and guide and inform the development of next-generation planet detection and characterization missions. By observing and understanding O 2 in its planetary context we can increase our confidence in the remote detection of life, and provide a model for biosignature development for other proposed biosignatures.

Victoria S Meadows↗

Kepler Planet Detection Metrics: Robovetter Completeness and Effectiveness for Data Release 25

In general, the Kepler pipeline identifies a list of Threshold Crossing Events (TCEs), which are periodic flux decrements meeting certain criteria (Jenkins, 2017). These TCEs are reviewed and those that appear consistent with astrophysically transiting or eclipsing systems are classified as Kepler Objects of Interest (KOIs). Further review is given to KOIs, which are then dispositioned as Planet Candidates (PCs) or False Positive (FPs). FPs are further denoted by four major flags that indicate if the signal is Not Transit-Like (NTL), due to a Stellar Eclipse (SS; previously referred to as Significant Secondary), and/or due to contamination from a source other than the target as evidenced by a Centroid Offset (CO) oran Ephemeris Match (EM) with another object. This entire TCE review process is known as dispositioning or vetting.In the first five Kepler mission planet candidate catalogs (Borucki et al., 2011a,b; Batalha et al., 2013; Burke et al., 2014; Rowe et al., 2015), TCEs were manually examined on an individual basis and dispositioned using various plots and quantitative diagnostic tests (see e.g., Coughlin, 2017). In the sixth catalog, Mullally et al. (2015a) employed partial automation via simple parameter cuts to automatically disposition a large fraction of TCEs as not transit-like. Mullally et al. (2015a) also used an automated technique known as the centroid Robovetter (Mullally, 2017) to automatically identify some FP KOIs due to centroid offsets - a telltale signature of light contamination from another target. The remaining targets were manually dispositioned. In the seventh catalog, Coughlin et al. (2016) automated theentire dispositioning process using what is collectively known simply as the Robovetter.In the eighth and final mission catalog, Thompson et al. (2017) use a revised Robovetter to automate the dispositioning of all TCEs with an emphasis on creating a catalog suitable for accurately determining planet occurrence rates. In order to calculate accurate occurrence rates, the completeness and effectiveness of the Robovetter must be characterized. We define these terms as applied to the Robovetter, following Thompson et al. (2017), as:1. Completeness: The fraction of transiting planets detected by the pipeline that are classified as planet candidates by the Robovetter.2. Effectiveness: The fraction of false positives detected by the pipeline that are classified as false positives by the Robovetter.The remainder of this document describes products that can be used to quantitatively assess Robovetter completeness and effectiveness for an arbitrary set of Kepler stars.

Robovetter↗

Neural Network Target Identification System for False Alarm Reduction

A multi-stage automated target recognition (ATR) system has been designed to perform computer vision tasks with adequate proficiency in mimicking human vision. The system is able to detect, identify, and track targets of interest. Potential regions of interest (ROIs) are first identified by the detection stage using an Optimum Trade-off Maximum Average Correlation Height (OT-MACH) filter combined with a wavelet transform. False positives are then eliminated by the verification stage using feature extraction methods in conjunction with neural networks. Feature extraction transforms the ROIs using filtering and binning algorithms to create feature vectors. A feed forward back propagation neural network (NN) is then trained to classify each feature vector and remove false positives. This paper discusses the test of the system performance and parameter optimizations process which adapts the system to various targets and datasets. The test results show that the system was successful in substantially reducing the false positive rate when tested on a sonar image dataset.

ATR↗