Field Assessment of Energy Audit Tools for Retrofit Programs

This project focused on the use of home energy ratings as a tool to promote energy retrofits in existing homes. A home energy rating provides a quantitative appraisal of a home’s energy performance, usually compared to a benchmark such as the average energy use of similar homes in the same region. Rating systems based on energy performance models, the focus of this report, can establish a home’s achievable energy efficiency potential and provide a quantitative assessment of energy savings after retrofits are completed, although their accuracy needs to be verified by actual measurement or billing data. Ratings can also show homeowners where they stand compared to their neighbors, thus creating social pressure to conform to or surpass others. This project field-tested three different building performance models of varying complexity, in order to assess their value as rating systems in the context of a residential retrofit program: Home Energy Score, SIMPLE, and REM/Rate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

HPXML to Home Energy Score Translator

Home Energy Score is a simulation-based rating method for existing homes. Home Performance XML (HPXML) is a data transfer standard for home energy audit and retrofit data used throughout the industry. This software receives an HPXML document and translates the building characteristics into HEScore inputs compliant with their API.

Market, Noel↗

Multi-state residential transaction estimates of solar photovoltaic system premiums

We report that as of the second quarter of 2016 more than 1.1 million solar photovoltaic (PV) homes exist in the US. Capturing the value these PV systems add to home sales is therefore important. Our study enhances the PV-home-valuation literature by analyzing 22,822 home sales, of which 3951 have PV, and which span eight states during 2002–2013. We also, for the first time, compare premiums with contributory value estimates derived from the present value of saved energy costs (income approach) and, separately, the replacement cost of systems at the time of sale (cost approach) to examine market signals. We find home buyers are consistently willing to pay PV home premiums across various states, housing and PV markets, and home types; average premiums equate to approximately $4/W or $15,000 for an average-sized 3.6-kW PV system. We find that a replacement cost net of state and federal incentives is a better proxy for premiums than gross installed costs, and that the income approach is a good signal if it accounts for tiered volumetric retail rates. Finally, other results include detailed premium analyses for PV home sub-populations.

14 SOLAR ENERGY↗

Manufactured Home Equipment Sizing and Selection Tool

This tool is for use for manufactured homes built to the HUD Code (thermal provisions of the Manufactured Housing Construction and Safety Standards, Subpart F, Section §3280), including manufactured homes certified as ENERGY STAR® and DOE Efficient New Homes. It provides a simple look-up procedure to assist equipment specifiers, HVAC contractors, home installers, retailers, manufacturers, and electric utility staff. For new manufactured homes, it guides in selection of single speed heat pumps and air conditioners. For existing homes, it determines design conditions and nominal equipment size. The guidelines provide a simple but accurate procedure that reduces oversizing and its associated problems.

Source record↗

Comfort in High-Performance Homes in a Hot-Humid Climate

TO5 2.3.2: Large-Scale Temperature Study Although space-conditioning systems are required to meet standards such as those in the Air Conditioning Contractors of America (ACCA) Manual RS (Rutkowski 1997) and the ASHRAE Standard 55 (ASHRAE 2013) comfort criteria, little is known about how space-conditioning systems are actually operating in the field and if these systems are meeting those standards. Unconventional space-conditioning systems may be necessary for low-load homes in the future. It is important to know how current systems are functioning in existing homes and to what temperatures occupants typically set the thermostats in their homes. The U.S. Department of Energy's Building America research team IBACOS set out to find some answers. By using low-cost data loggers and occupant surveys to monitor 37 single-family homes that have standard heating, ventilating, and air-conditioning (HVAC) equipment, the team gained insight into how sensitive occupants are to comfort in their homes relative to the ACCA and ASHRAE standards. This study focused on one climate zone (hot-humid); however, future studies may find differences among occupants- ideas of thermal comfort in other climate zones. Data were collected from installed sensors during a 2-month period from late August 2014 through late October 2014. The final aspect of this project was to review the business metrics associated with builders involved in a comfort and performance guarantee program. The results of this study-taken as an aggregate-show that the homes provided room-to-room temperature differences less than 6 degrees F 95% of the time. Temperature differences were less than 4 degrees F 80% of the time. Some homes showed better or worse performance. On average, two-story homes had a 3.3 degrees F temperature difference between rooms; single-story homes had an average of a 2.2 degrees F temperature difference between rooms. Occupants who did not use programmable thermostats had an average set point of 75 degrees F. Homes in which the thermostats were programmed with a setback schedule showed a median baseline temperature value of 74 degrees F and had a median afternoon setback of 75 degrees F. System runtime was analyzed and showed that the room-to-room temperature uniformity in some homes worsened during an on cycle, whereas the uniformity improved in other homes. That is, when the system was running, some rooms were receiving too much or too little air relative to the rest of the house, and the temperatures in those rooms were moving away from the temperatures of the other rooms in the house. Finally, analysis of the thermostat data shows a wide degree of variability among homes in the study. Interpretation of the measured data suggests that 21 occupants made no regular adjustments to the thermostats in their homes, seven had regular setbacks, seven showed varying setbacks, and 10 appeared to follow no pattern (with random adjustments). Ultimately, the data show that current systems are maintaining expected levels of comfort. As expected, it is more challenging to maintain a uniform temperature in all rooms of two-story homes, and future systems should address this issue. Furthermore, the data show that the majority of homes maintained relative humidity levels below 60% without any supplemental dehumidification

ACCA Manual RS↗

A Meta-Analysis of Single-Family Deep Energy Retrofit Performance in the U.S.

The current state of Deep Energy Retrofit (DER) performance in the U.S. has been assessed in 116 homes in the United States (US), using actual and simulated data gathered from the available domestic literature. Substantial airtightness reductions averaging 63% (n=48) were reported (two- to three-times more than in conventional retrofits), with average post-retrofit airtightness of 4.7 Air Changes per House at 50 Pascal (ACH 50 ) (n=94). Yet, mechanical ventilation was not installed consistently. In order to avoid indoor air quality (IAQ) issues, all future DERs should comply with ASHRAE 62.2-2013 requirements or equivalent. Projects generally achieved good energy results, with average annual net-site and net-source energy savings of 47%±20% and 45%±24% (n=57 and n=35), respectively, and carbon emission reductions of 47%±22% (n=23). Net-energy reductions did not vary reliably with house age, airtightness, or reported project costs, but pre-retrofit energy usage was correlated with total reductions (MMBtu). Annual energy costs were reduced $\$1,283$ ± $\$804$ (n=31), from a pre-retrofit average of $\$2,738$ ± $\$1,065$ to $\$1,588$ ± $\$561$ post-retrofit (n=25 and n=39). The average reported incremental project cost was $\$40,420$ ± $\$30,358$ (n=59). When financed on a 30-year term, the median change in net-homeownership cost was only $\$1.00$ per month, ranging from $\$149$ in savings to an increase of $\$212$ (mean= $\$15.67$ ± $\$87.74$; n=28), and almost half of the projects resulted in reductions in net-cost. The economic value of a DER may be much greater than is suggested by these net-costs, because DERs entail substantial non-energy benefits (NEBs), and retrofit measures may add value to a home at resale similarly to general remodeling, PV panel installation, and green/energy efficient home labels. These results provide estimates of the potential of DERs to address energy use in existing homes across climate zones that can be used in future estimates of the technical potential to reduce household energy use and greenhouse gas emissions through DERs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing Hydronic System Performance in Residential Applications

Even though new homes constructed with hydronic heat comprise only 3% of the market (US Census Bureau 2009), of the 115 million existing homes in the United States, almost 14 million of those homes (11%) are heated with steam or hot water systems according to 2009 US Census data. Therefore, improvements in hydronic system performance could result in significant energy savings in the US. When operating properly, the combination of a gas-fired condensing boiler with baseboard convectors and an indirect water heater is a viable option for high-efficiency residential space heating in cold climates. Based on previous research efforts, however, it is apparent that these types of systems are typically not designed and installed to achieve maximum efficiency. Furthermore, guidance on proper design and commissioning for heating contractors and energy consultants is hard to find and is not comprehensive. Through modeling and monitoring, CARB sought to determine the optimal combination(s) of components - pumps, high efficiency heat sources, plumbing configurations and controls - that result in the highest overall efficiency for a hydronic system when baseboard convectors are used as the heat emitter. The impact of variable-speed pumps on energy use and system performance was also investigated along with the effects of various control strategies and the introduction of thermal mass.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Remote Home Energy Score Assessments (Feasibility Study)

The delivery of Home Energy Scores (HES) has been significantly impacted over the last year by the recent pandemic and ongoing limitations to person-to-person interactions. There are also historic challenges in providing HES to more remote geographies where assessor infrastructure is not in place. Alternative approaches to in-person, on-site home energy assessments could help address these current restrictions, while also potentially providing opportunities for the efficient delivery of HES in certain use cases after COVID-related restrictions are lifted. From the program administrator’s perspective, there needs to be confidence that the remote scores closely match what they would have been if the assessment had been performed on-site. The recommendations shown on a report generated from a remote score should closely match those of an onsite assessment. A remote assessment should be an option for all HES Partners and have direction on how to deliver those scores. From the HES partner’s and assessor’s perspective, there needs to be understanding of what level of experience is needed, what system infrastructure is required, the time expenditure of the remote assessment process, and the limitations of a remote assessment. From the homeowner’s perspective, there needs to be an awareness and comfort with the time commitment, the level of knowledge of the home, the equipment needed, and any physical requirements of the remote assessment process. During this study, Earth Advantage assessed methods for delivering Home Energy Score assessments remotely through web-based technology platforms and resident interaction in a diverse array of home types in different geographic locations. Earth Advantage developed remote assessment test protocols and integrated those testing protocols into existing Home Energy Score programs being overseen by USDOE Home Energy Score partners New York State Energy Research & Development Authority (NYSERDA), the Oregon Department of Energy (ODOE), and the City of Portland (PDX). Earth Advantage staff acted as the Remote assessor and gathered HES data remotely during the video sessions with participants. Authorized Home Energy Score assessors performed the onsite assessments that were then used to compare with the remote assessment data. This allowed the research to effectively test the efficacy of various remote assessment approaches in a diverse array of home-types. Earth advantage identified the key components of a remote assessment infrastructure which included Remote Home Energy Score Assessments Page vi processes, tools, services, methods and mechanisms that would better enable remote assessments. This report details methods, results, and findings of the HES remote assessment research. In addition, the report provides recommendations and best practices that could be used as guidance for the Home Energy Score administrator and the HES partners seeking to effectively conduct remote assessments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing Hydronic System Performance in Residential Applications

Even though new homes constructed with hydronic heat comprise only 3% of the market (US Census Bureau 2009), of the 115 million existing homes in the United States, almost 14 million of those homes (11%) are heated with steam or hot water systems according to 2009 US Census data. Therefore, improvements in hydronic system performance could result in significant energy savings in the US.

AFUE↗

Wall Upgrades for Residential Deep Energy Retrofits: A Literature Review

In the United States, 39% of total energy consumption comes from the building sector, 20% of which is attributed to residential buildings. New, high-performance homes incorporate a combination of tight building envelopes, mechanical ventilation and efficient components to ensure comfort, adequate airflow and moisture control. These systems work together to create energy efficient homes that employ measures to manage moisture and indoor pollutants. Older homes, built before 1992 when DOE’s Building Energy Codes Program was established represent approximately 68% of building stock in the country, and often have significant air leakage and inadequate insulation. Homes with little to no air sealing or insulation result in heating and cooling losses, which can represent a substantial portion of utility bills. Done correctly, deep energy retrofits (DERs) can significantly improve the energy performance of a home’s thermal envelope, decrease indoor pollutants and increase homeowner comfort. This literature review summarizes current practices for exterior wall retrofits for existing homes, provides an overview of techno-economic approaches to investigate residential wall systems, and discusses thermal and hygrothermal modeling strategies. Accompanying this literature review is a larger effort to identify state-of-the-art technologies for existing wall energy efficiency retrofit systems that can be applied over existing siding and are suitable for the cold/very cold climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cost Analysis of Roof-Only Air Sealing and Insulation Strategies on 1 ½-Story Homes in Cold Climates

The External Thermal and Moisture Management System (ETMMS), typically seen in deep energy retrofits, is a valuable approach for the roof-only portions of existing homes, particularly the 1 ½-story home. It is effective in reducing energy loss through the building envelope, improving building durability, reducing ice dams, and providing opportunities to improve occupant comfort and health.

1 1/2-Story House↗

Cost Analysis of Roof-Only Air Sealing and Insulation Strategies on 1 ½-Story Homes in Cold Climates

The External Thermal and Moisture Management System (ETMMS), typically seen in deep energy retrofits, is a valuable approach for the roof-only portions of existing homes, particularly the 1 ½-story home. It is effective in reducing energy loss through the building envelope, improving building durability, reducing ice dams, and providing opportunities to improve occupant comfort and health.

1 ½-Story House↗

Bringing Low- and Moderate-Income Solar Financing Models to Scale (Final Technical Report (FTR))

In this final report, the Clean Energy States Alliance(CESA) and its project partners describe their work to accelerate the development of solar projects for three distinct subsets of the low- to moderate-income(LMI) solar market: single-family homes, manufactured homes, and community institutions, including multifamily affordable housing. For each market sector, the project team undertook research, outreach, and market-building activities. By advancing promising LMI solar financing innovations for different housing types and spreading them to new locations, the Scaling Up Solar for Under-Resourced Communities project has built momentum to scale up LMI solar. Although the report describes some research pertaining to solar adoption in LMI communities, this project was original in that it focused on two specific models to tackle single-family homes and community institutions. Until this project, very little research dedicated to solar for manufactured homes existed. For each market sector, the project team undertook research, outreach, and market-building activities. For the single-family homes sector, the project encouraged states to adapt a program model based on a successful Connecticut initiative that has brought solar to thousands of LMI homeowners. For manufactured homes, the project analyzed the potential for using solar for that housing sector and worked with states, utilities, and other stakeholders to launch pilot projects or programs. For community institutions, the project team worked with foundations, lenders, and community service organizations to inventory, analyze, and communicate models for philanthropic investment that accelerate the deployment of solar and solar+storage in multifamily affordable housing, health centers, and other LMI-serving community institutions.

14 SOLAR ENERGY↗

Feasibility Study: Ductless Hydronic Distribution Systems with Fan Coil Delivery

Hydronic distribution systems have a long history, and are widely used in commercial buildings. As with mini-split heat pumps, hydronic systems using small terminal fan coils have the potential to provide high-quality comfort to homes that have small heating and cooling loads, but at a lower cost and with greater flexibility. These “ductless hydronic” distribution systems eliminate space requirements needed for ducting, eliminate duct thermal losses, and are easy to zone. Since heat pump chiller-heaters can be charged with refrigerant at the factory, hydronic systems also avoid refrigerant system faults such as incorrect charge and inadequate evacuation of lines that can lead to sub-standard performance. Other advantages include: reduction in the amount of energy required to deliver heating and cooling, reduced equipment cycling, and the potential for incorporating energy storage for peak load avoidance and demand response. Ductless hydronic systems are best suited for new homes, but with the relative ease of installing piping in attic spaces (for example under attic insulation), they are also suitable for existing homes that have old, leaky, and poorly insulated ducts. With a broader and more affordable product offering from manufacturers, installation guidelines, and contractor training, this method of distribution has significant potential to meet the space conditioning needs of high performance homes. The primary objectives of this study are to estimate potential energy savings relative to conventional ducted air distribution, and to identify equipment requirements, costs, and barriers. The analysis focuses on ductless hydronic delivery systems that use water-to-air terminal units in each zone. This system type is applicable in all climate regions and can provide sensible and latent cooling and/or heating using a single hot and chilled water source such as a heat pump, or a separate water heater and chiller. Results of TRNSYS modeling indicate that annual heating and cooling energy use (site and source) can be reduced by up to 22% when substituting pipes, pump, small distributed fan coils, and a water-to-air heat pump for the ducts, air handler, indoor coil, and conventional air-to-air heat pump unit of similar rating as the air-to-water unit. Of the 22% savings, on average 36% is attributable to the lower energy required by pumps and small fans vs. air handler blowers, and 64% to the reduced losses from pipes as compared to ducts. Using the modeled energy savings and estimated costs, hydronic distribution appears to be economically viable in three of the four climates evaluated. Other current field studies of air-to-water heat pumps coupled to radiant floor systems are demonstrating heat pump performance that exceeds seasonal performance calculated using a standard heat pump performance map (German, 2011a, German, 2011b). Hydronic distribution systems can meet sensible and latent cooling needs in all climates. Major barriers to widespread application include the lack of low-cost, small, ceiling-mounted fan coils, and the limited availability and higher cost of air-to-water heat pumps. The latter could be overcome by the production of an add-on refrigerant-to-water conversion kit that could be used to adapt any heat pump to serve as a water chiller-heater. Development of accurate performance maps and additional data on field performance are areas that should be targeted by future research.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Excavationless Exterior Foundation Insulation Exploratory Study

The key objective of this exploratory study was to investigate the feasibility of the development or adoption of technologies that would enable a large percentage of existing homes in cold climates to apply a combination 'excavationless' soil removal process with appropriate insulation and water management on the exterior of existing foundations at a low cost. Our approach was to explore existing excavation and material technologies and systems to discover whether potential successful combinations existed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Cost Analysis of Roof-Only Air Sealing and Insulation Strategies on 1-1/2 Story Homes in Cold Climates, Minneapolis, MN (Fact Sheet)

The External Thermal and Moisture Management System (ETMMS), typically seen in deep energy retrofits, is a valuable approach for the roof-only portions of existing homes, particularly the 1 1/2-story home. It is effective in reducing energy loss through the building envelope, improving building durability, reducing ice dams, and providing opportunities to improve occupant comfort and health.

1 1/2-STORY HOUSE↗

Technology Solutions Case Study: Replacement of Variable-Speed Motors for Furnaces

In conjunction with the New York State Energy Research and Development Authority (NYSERDA) and Proctor Engineering Group, Ltd. (PEG), the Consortium for Advanced Residential Buildings (CARB) evaluated the Concept 3™ replacement motors for residential furnaces in eight homes in Syracuse, NY. These brushless, permanent magnet (BPM) motors can use much less electricity than their PSC (permanent split capacitor) predecessors. This evaluation focuses on existing homes in the heating-dominated climate of upstate New York with the goals of characterizing field performance and cost-effectiveness. The results of this study are intended to be useful to home performance contractors, HVAC contractors, and home efficiency program stakeholders. Tests and monitoring was performed both before and after fan motors were replaced. Average fan power reductions were approximately 126 Watts during heating and 220 Watts during cooling operation. Over the course of entire heating and cooling seasons, these translated into average electric energy savings of 163 kWh, with average cost savings of $20 per year. Homes where the fan was used outside of heating and cooling mode saved an additional $42 per year on average. Results indicate that BPM replacement motors will be most cost-effective in HVAC systems with longer run times and relatively low duct static pressures. More dramatic savings are possible if occupants use the fan-only setting when there is no thermal load.

air handler unit↗