Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “evaluation study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Preconceptual Feasibility Study to Evaluate Alternative Means to Produce Plutonium-238

There is currently no large-scale production of 238Pu in the United States. Feasibility studies were performed at the Idaho National Laboratory to assess the capability of developing alternative 238Pu production strategies. Initial investigations indicate potential capability to provision radioisotope-powered systems for future space exploration endeavors. For the short term production of 238Pu, sealed canisters of dilute 237Np solution in nitric acid could be irradiated in the Advanced Test Reactor (ATR). Targets in the large and medium “I” positions of the ATR were irradiated over a simulated period of 306 days and analyzed using MCNP5 and ORIGEN2.2. Approximately 0.5 kg of 238Pu could be produced annually in the ATR with purity greater than 92%. Optimization of the irradiation cycles could further increase the purity to greater than 98%. Whereas the typical purity of space batteries is between 80 to 85%, the higher purity 238Pu produced in the ATR could be blended with existing lower-purity inventory to produce useable material. Development of irradiation methods in the ATR provides the fastest alterative to restart United States 238Pu production. The analysis of 238Pu production in the ATR provides the technical basis for production using TRIGA® (Training, Research, Isotopes, General Atomics) nuclear reactors. Preliminary analyses envisage a production rate of approximately 0.7 kg annually using a single dedicated 5-MW TRIGA reactor with continuous flow loops to achieve high purity product. Two TRIGA reactors represent a robust means of providing at over 1 kg/yr of 238Pu annually using dilute solution targets of 237Np in nitric acid. Further collaboration and optimization of reactor design, radiochemical methods, and systems analyses would further increase annual 238Pu throughput, while reducing the currently evaluated reactor requirements.

07 ISOTOPE AND RADIATION SOURCES↗

Very High Efficiency Dedicated Outdoor Air System Field Site Re-Evaluation

The study reported here evaluated the long-term performance of Very High Efficiency (VHE) Dedicated Outside Air Systems (DOASs) installed at eight sites that participated in field evaluation studies performed by the Northwest Energy Efficiency Alliance (NEEA) and Institute for Market Transformation (IMT) from 2015 through 2020. The study compared the energy performance of the systems in 2021-2022 to the findings of the original evaluation. It also evaluated the indoor environmental quality (IEQ) as perceived by occupants and building operator feedback before and after the system conversion. The findings of the study are important for building owners and managers who are considering adopting VHE DOASs. The study found that the systems: (1) consistently saved energy over the long term, (2) improved occupant comfort, and (3) received positive feedback from building operators. All of the sites had similar or improved energy savings over the pre-conversion system compared to the original evaluation savings, and only one site had a small reduction in energy savings. The sites averaged 48 percent whole site energy savings compared to the pre-conversion system. The continued energy performance of these sites provides strong evidence that the energy savings achieved by VHE DOAS retrofits will be sustained long term. The study also investigated the changes in occupant comfort resulting from the VHE DOAS retrofit. Responses to a survey sent to the sites’ occupants revealed that the conversion resulted in a better indoor environment for the occupants. Most respondents reported that their satisfaction increased, and dissatisfaction decreased post-conversion. Overall occupants were 43 percent more satisfied and 30 percent less dissatisfied post-conversion compared to pre-conversion. The study's findings suggest that a VHE DOAS can be a solution to improve the energy efficiency, reduce energy costs, and increase occupant comfort in buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NAS-Wide Fast-Time Simulation Study for Evaluating Performance of UAS Detect-and-Avoid Alerting and Guidance Systems

This presentation contains the analysis results of NAS-wide fast-time simulations with UAS and VFR traffic for a single day for evaluating the performance of Detect-and-Avoid (DAA) alerting and guidance systems. This purpose of this study was to help refine and validate MOPS alerting and guidance requirements. In this study, we generated plots of all performance metrics that are specified by RTCA SC-228 Minimum Operational Performance Standards (MOPS): 1) to evaluate the sensitivity of alerting parameters on the performance metrics of each DAA alert type: Preventive, Corrective, and Warning alerts and 2) to evaluate the effect of sensor uncertainty on DAA alerting and guidance performance.

DAA Alerting Performance↗

Evaluating Utility Costs Savings and Resilience: A Case Study in Port Arthur, Texas

This study evaluates the techno-economic feasibility of integrating solar photovoltaics (PV), battery energy storage systems (BESS), and generators to enhance both cost savings and resilience in critical community facilities in Port Arthur, Texas. Using NREL's REopt model, we analyze four facilities: the Golden Triangle Empowerment Center (GTEC), Lamar State College (LSC), Port Arthur Independent School District (PAISD), and Port Arthur Transit (PAT). A key aspect of the analysis is the incorporation of the Value of Lost Load (VoLL) and microgrid upgrade costs to assess the hidden value of resilience during grid outages. While standalone PV scenarios show moderate cost reductions and a 10-15% decrease in CO2 emissions, the inclusion of resilience measures with BESS and generators significantly increases system costs. However, the hidden value of resilience - quantified through avoided outage costs - leads to a substantial improvement in financial outcomes, resulting in positive Net Present Value (NPV) at many sites. The study demonstrates that resilient solar and storage systems offer both economic and resilience benefits, particularly for underserved communities, by balancing energy savings and enhanced operational continuity during outages.

14 SOLAR ENERGY↗

Evaluation of U.S. Building Energy Benchmarking and Transparency Programs: Attributes, Impacts, and Best Practices

In the last decade, a new policy area has emerged to boost energy efficiency in buildings that focuses on the simple action of measuring energy use as compared to buildings of similar type and size, and making that data publicly available. These efforts, referred to as benchmarking and transparency (B&T) policies, seek to unlock new energy efficiency opportunities in the country’s existing buildings by promoting data-driven decision-making and creating stronger market signals. This report focuses on the 24 state and local jurisdictions that (as of December 31, 2016) require owners of privately owned commercial buildings, multifamily buildings, or both to comply with a B&T policy. The report provides a summary of U.S. B&T policy design and implementation characteristics, reports results and impacts for jurisdictions with B&T policies, and discusses opportunities for increasing the efficacy of B&T policies, as well as suggested areas for further research. Among the findings, all but one of the B&T policy evaluation studies reviewed indicate some reduction (from 1.6% to 14%) in energy use, energy costs, or energy intensity over the two- to four-year period of the analyses. More specifically, most of the studies reviewed indicate 3% to 8% reductions in gross energy consumption or energy use intensity over a two- to four-year period of B&T policy implementation. Two additional evaluation studies indicate that there is a causal relationship between B&T policies and energy savings or energy cost savings. These documented impacts should be reviewed with some caution. While consistently showing energy savings benefits associated with B&T policies, these savings estimates should be considered preliminary because of the limited period of analyses and inconsistencies in analysis methods for the various studies. A nationally standardized method for data collection, reporting, and evaluation of B&T policies—developed with an advisory group of state and local jurisdictions, energy efficiency and evaluation experts, building owner and real estate associations, and other stakeholders—could improve the consistency and quality of B&T impact studies, providing policymakers and others with a more complete understanding of the present and future impacts of these policies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Methods for Multidisciplinary Design Optimization (MDO)

The NASA Langley Multidisciplinary Design Optimization (MDO) method evaluation study seeks to arrive at a set of guidelines for using promising MDO methods by accumulating and analyzing computational data for such methods. The data are collected by conducting a series of reproducible experiments. This report documents all computational experiments conducted in Phase I of the study. This report is a companion to the paper titled Initial Results of an MDO Method Evaluation Study by N. M. Alexandrov and S. Kodiyalam (AIAA-98-4884).

Kodiyalam, Srinivas↗

Decommissioning concepts for the norwegian nuclear research facilities Halden and Kjeller - 15022

The Norwegian nuclear research facilities Halden and Kjeller are near the end of their current operational licenses. Thus, the Norwegian Ministry of Trade, Industry and Fisheries have decided that a concept evaluation study shall be made on the decommissioning alternatives for these facilities. This task was given to Ndcon (Westinghouse and Studsvik) with their broad experience in decommissioning planning and decades of nuclear expertise, together with DNV GL, that is certified in Norway for concept evaluation studies. The decommissioning alternatives that have been evaluated are strategy, end-state and waste management options. The decommissioning strategies are the IAEA defined immediate dismantling, deferred dismantling and entombment. The different end-states that have been evaluated are unrestricted use (green field), light industry (brown field) and other nuclear activity, in which the site will continue to have a nuclear license even after the decommissioning. The waste management options are direct disposal of materials, recycling of materials off-site and recycling on-site. The result of the cost estimation is that it is possible to identify viable alternatives for a chosen decommissioning strategy, end state and waste management options. The expected duration of the decommissioning program is 10 years for both sites, the dismantling and demolition period is expected to be able to perform within 4 years. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Meta-analysis of 18F-FDG PET/CT in the diagnosis of infective endocarditis

Background: The current diagnosis of infective endocarditis (IE) is based on the modified Duke criteria, which has approximately 80% sensitivity for the diagnosis of native valve endocarditis (NVE), with lower sensitivity for the diagnosis of prosthetic valve endocarditis (PVE) and culture-negative endocarditis. There is preliminary evidence that {sup 18}F-FDG PET/CT is an adjunctive diagnostic test with high accuracy reported in small studies to date. We therefore performed a meta-analysis of studies evaluating the use of PET/CT in the diagnosis of IE to establish a more precise estimate of accuracy. Methods: PubMed, Embase, Cochrane library, CINAHL, Web of Knowledge, and www.clinicaltrials.gov were searched from January 1990 to April 2017 for studies evaluating the accuracy of PET/CT for the evaluation of possible IE. Results: We identified 13 studies involving 537 patients that were included in the meta-analysis. The pooled sensitivity of PET/CT for diagnosis of IE was 76.8% (95% CI 71.8–81.4%; Q = 39.9, P < 0.01; I{sup 2} = 69.9%) and the pooled specificity was 77.9% (95% CI 71.9–83.2%; Q = 44.42, P < 0.01; I{sup 2} = 73.0%). Diagnostic accuracy was improved for PVE with sensitivity of 80.5% (95% CI 74.1–86.0%; Q = 25.5, P < 0.01; I{sup 2} = 72.5%) and specificity of 73.1% (95% CI 63.8–81.2%; Q = 32.1, P < 0.01; I{sup 2} = 78.2%). Additional extracardiac foci of infection were found on 17% of patients on whole body PET/CT. Conclusion: PET/CT is a useful adjunctive diagnostic tool in the evaluation of diagnostically challenging cases of IE, particularly in prosthetic valve endocarditis. It also has the potential to detect clinically relevant extracardiac foci of infection, malignancy, and other sources of inflammation leading to more appropriate treatment regimens and surgical intervention.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Million Person Study Innovation: Evaluating Cognitive Impairment and other Morbidity Outcomes from Chronic Radiation Exposure Through Linkages with the Centers for Medicaid and Medicare Services Assessment and Claims Data

Here, the study of One Million U.S. Radiation Workers and Veterans, the Million Person Study (MPS), examines the health consequences, both cancer and non-cancer, of exposure to ionizing radiation received gradually over time. Recently the MPS has focused on mortality patterns from neurological and behavioral conditions, e.g., Parkinson's disease, Alzheimer's disease, dementia, and motor neuron disease such as amyotrophic lateral sclerosis. A fuller picture of radiation-related late effects comes from studying both mortality and the occurrence (incidence) of conditions not leading to death. Accordingly, the MPS is identifying neurocognitive diagnoses from fee-for-service insurance claims from the Centers for Medicare and Medicaid Services (CMS), among Medicare beneficiaries beginning in 1999 (the earliest date claims data are available). Linkages to date have identified ∼540,000 workers with available health information. Such linkages provide individual information on important co-factor and confounding variables such as smoking, alcohol consumption, blood pressure, obesity, diabetes and many other health and demographic characteristics. The total person-level set of time-dependent variables, outcomes, organ-specific dose measures, co-factors, and demographics will be massive and much too large to be evaluated with standard software. Thus, development of specialized open-source software designed for large datasets (Colossus) is nearly complete. The wealth of information available from CMS claims data, coupled with individual dose reconstructions, will thus greatly enhance the quality and precision of health evaluations for this new field of low-dose radiation and neurocognitive effects.

Dauer, Lawrence T.↗

Perioperative Timing of Infliximab and the Risk of Serious Infection After Elective Hip and Knee Arthroplasty

Objective The optimal timing of tumor necrosis factor antagonists before elective surgery is unknown. This study evaluated the association between infliximab timing and serious infection after elective hip or knee arthroplasty. Methods A retrospective cohort study evaluated US Medicare patients with rheumatoid arthritis, inflammatory bowel disease, psoriasis, psoriatic arthritis, or ankylosing spondylitis who received infliximab within 6 months of elective knee or hip arthroplasty from 2007 to 2013. Propensity‐adjusted analyses examined whether infliximab stop timing (time between the most recent infusion and surgery) was associated with hospitalized infection within 30 days or prosthetic joint infection ( PJI ) within 1 year. Results Hospitalized infection within 30 days occurred after 270 of 4,288 surgeries (6.3%). Infliximab stop timing <4 weeks versus 8–12 weeks was not associated with an increase in infection within 30 days (propensity‐adjusted odds ratio [ OR ] 0.90 [95% confidence interval (95% CI ) 0.60–1.34]). The rate of PJI was 2.9 per 100 person‐years and was not increased in patients with stop timing <4 weeks versus 8–12 weeks (hazard ratio [ HR ] 0.98 [95% CI 0.52–1.87]). Glucocorticoid dosage >10 mg/day was associated with increased risk of 30‐day infection ( OR 2.11 [95% CI 1.30–3.40]) and PJI ( HR 2.70 [95% CI 1.30–5.60]). Other risk factors for infection included elderly age, comorbidities, revision surgery, and previous hospitalized infection. Conclusion Administering infliximab within 4 weeks of elective knee or hip arthroplasty was not associated with a higher risk of short‐ or long‐term serious infection compared to withholding infliximab for longer time periods. Glucocorticoid use, especially >10 mg/day, was associated with an increased infection risk.

George, Michael D.↗

Technical Note: Phantom study to evaluate the dose and image quality effects of a computed tomography organ-based tube current modulation technique

Purpose: This technical note quantifies the dose and image quality performance of a clinically available organ-dose-based tube current modulation (ODM) technique, using experimental and simulation phantom studies. The investigated ODM implementation reduces the tube current for the anterior source positions, without increasing current for posterior positions, although such an approach was also evaluated for comparison. Methods: Axial CT scans at 120 kV were performed on head and chest phantoms on an ODM-equipped scanner (Optima CT660, GE Healthcare, Chalfont St. Giles, England). Dosimeters quantified dose to breast, lung, heart, spine, eye lens, and brain regions for ODM and 3D-modulation (SmartmA) settings. Monte Carlo simulations, validated with experimental data, were performed on 28 voxelized head phantoms and 10 chest phantoms to quantify organ dose and noise standard deviation. The dose and noise effects of increasing the posterior tube current were also investigated. Results: ODM reduced the dose for all experimental dosimeters with respect to SmartmA, with average dose reductions across dosimeters of 31% (breast), 21% (lung), 24% (heart), 6% (spine), 19% (eye lens), and 11% (brain), with similar results for the simulation validation study. In the phantom library study, the average dose reduction across all phantoms was 34% (breast), 20% (lung), 8% (spine), 20% (eye lens), and 8% (brain). ODM increased the noise standard deviation in reconstructed images by 6%–20%, with generally greater noise increases in anterior regions. Increasing the posterior tube current provided similar dose reduction as ODM for breast and eye lens, increased dose to the spine, with noise effects ranging from 2% noise reduction to 16% noise increase. At noise equal to SmartmA, ODM increased the estimated effective dose by 4% and 8% for chest and head scans, respectively. Increasing the posterior tube current further increased the effective dose by 15% (chest) and 18% (head) relative to SmartmA. Conclusions: ODM reduced dose in all experimental and simulation studies over a range of phantoms, while increasing noise. The results suggest a net dose/noise benefit for breast and eye lens for all studied phantoms, negligible lung dose effects for two phantoms, increased lung dose and/or noise for eight phantoms, and increased dose and/or noise for brain and spine for all studied phantoms compared to the reference protocol.

60 APPLIED LIFE SCIENCES↗

Use of MODIS Terra Imagery to Estimate Surface Water Quality Standards, Using Lake Thonotosassa, Florida, as a Case Study

Lake Thonotosassa is a highly eutrophied lake located in an area with rapidly growing population in the Tampa Bay watershed, Florida. The Florida Administrative Code has designated its use for "recreation, propagation and maintenance of a healthy, well-balanced population of fish and wildlife." Although this lake has been the subject of efforts to improve water quality since 1970, overall water quality has remained below the acceptable state standards, and has a high concentration of nutrients. This condition is of great concern to public health since it has favored episodic blooms of Cyanobacteria. Some Cyanobacterial species release toxins that can reach humans through drinking water, fish consumption, and direct contact with contaminated water. The lake has been historically popular for fishing and water sports, and its overflow water drains into the Hillsborough River, the main supply of municipal water for the City of Tampa, this explains why it has being constantly monitored in situ for water quality by the Environmental Protection Commission of Hillsborough County (EPC). Advances in remote sensing technology, however, open the possibility of facilitating similar types of monitoring in this and similar lakes, further contributing to the implementation of surveillance systems that would benefit not just public health, but also tourism and ecosystems. Although traditional application of this technology to water quality has been focused on much larger coastal water bodies like bays and estuaries, this study evaluates the feasibility of its application on a 46.6 km2 freshwater lake. Using surface reflectance products from Moderate-Resolution Imaging Spectroradiometer (MODIS) Terra, this study evaluates associations between remotely sensed data and in situ data from the EPC. The parameters analyzed are the surface water quality standards used by the State of Florida and general indicators of trophic status.

Moreno, Max J.↗

Phthalate exposure associated with self-reported diabetes among Mexican women

Background: Phthalates are ubiquitous industrial chemicals used as plasticizers in plastics made of polyvinyl chloride (PVC) to confer flexibility and durability. They are also present in products used for personal-care, industry and in medical devices. Phthalates have been associated with several adverse health effects, and recently it has been proposed that exposure to phthalates, could have an effect on metabolic homeostasis. This exploratory cross-sectional study evaluated the possible association between phthalate exposure and self-reported diabetes among adult Mexican women. Methods: As part of an on-going case-control study for breast cancer, only controls were selected, which constituted 221 healthy women matched by age ({+-}5 years) and place of residence with the cases. Women with diabetes were identified by self-report. Urinary concentrations of nine phthalate metabolites were measured by online solid phase extraction coupled to high performance liquid chromatography-isotope-dilution tandem mass spectrometry. Results: Participants with diabetes had significantly higher concentrations of di(2-ethylhexyl) pththalate (DEHP) metabolites: mono(2-ethyl-5-hydroxyhexyl) phthalate (MEHHP), mono(2-ethyl-5-oxohexyl) phthalate (MEOHP) and mono(2-ethyl-5-carboxypentyl) phthalate (MECPP) but lower levels of monobenzyl phthalate (MBzP) a metabolite of benzylbutyl phthalate, compared to participants without diabetes. A marginally significant positive associations with diabetes status were observed over tertiles with MEHHP (OR{sub T3vs.T1}=2.66; 95% CI: 0.97-7.33; p for trend=0.063) and MEOHP (OR{sub T3vs.T1}=2.27; 95% CI; 0.90-5.75; P for trend=0.079) even after adjusting for important confounders. Conclusions: The results suggest that levels of some phthalates may play a role in the genesis of diabetes. - Highlights: {yields} This study evaluated phthalate exposure and diabetes status among Mexican women. {yields} Urinary phthalates metabolite concentrations were used to determine association. {yields} Participants with diabetes had higher concentrations of three DEHP metabolites. {yields} A positive association with diabetes status was found with MEHHP and MEOHP metabolites. {yields} Results suggest phthalate exposure can have a role in diabetes.

60 APPLIED LIFE SCIENCES↗

SU-D-209-05: Sensitivity of the Diagnostic Radiological Index of Protection (DRIP) to Procedural Factors in Fluoroscopy

Purpose: To evaluate the sensitivity of the Diagnostic Radiological Index of Protection (DRIP) to procedural factors in fluoroscopy in an effort to determine an appropriate set of scatter-mimicking primary beams (SMPB) to be used in measuring the DRIP. Methods: A series of clinical and factorial Monte Carlo simulations were conducted to determine the shape of the scattered X-ray spectra incident on the operator in different clinical fluoroscopy scenarios. Two clinical evaluations studied the sensitivity of the scattered spectrum to gantry angle and patient size while technical factors were varied according to measured automatic dose rate control (ADRC) data. Factorial evaluations studied the sensitivity of the scattered spectrum to gantry angle, field of view, patient size and beam quality for constant technical factors. Average energy was the figure of merit used to condense fluence in each energy bin to a single numerical index. Results: Beam quality had the strongest influence on the scattered spectrum in fluoroscopy. Many procedural factors affected the scattered spectrum indirectly through their effects on primary beam quality through ADRC, e.g., gantry angle and patient size. Lateral C-arm rotation, common in interventional cardiology, increased the energy of the scattered spectrum, regardless of the direction of rotation. The effect of patient size on scattered radiation depended on ADRC characteristics, patient size, and procedure type. Conclusion: The scattered spectrum striking the operator in fluoroscopy, and therefore the DRIP, is most strongly influenced by primary beam quality, particularly kV. Use cases for protective garments should be classified by typical procedural primary beam qualities, which are governed by the ADRC according to the impacts of patient size, anatomical location, and gantry angle. These results will help determine an appropriate set of SMPB to be used for measuring the DRIP.

60 APPLIED LIFE SCIENCES↗

SU-E-T-83: A Study On Evaluating the Directional Dependency of 2D Seven 29 Ion Chamber Array Clinically with Different IMRT Plans

Purpose: To evaluate the directional dependency of 2D seven 29 ion chamber array clinically with different IMRT plans. Methods: 25 patients already treated with IMRT plans were selected for the study. Verification plans were created for each treatment plan in eclipse 10 treatment planning system using the AAA algorithm with the 2D array and the Octavius CT phantom. Verification plans were done 2 times for a single patient. First plan with real IMRT (plan-related approach) and second plan with zero degree gantry angle (field-related approach). Measurements were performed on a Varian Clinac-iX, linear accelerator equipped with a millennium 120 multileaf collimator. Fluence was measured for all the delivered plans and analyzed using the verisoft software. Comparison was done by selecting the fluence delivered in static gantry (zero degree gantry) versus IMRT with real gantry angles. Results: The gamma pass percentage is greater than 97 % for all IMRT delivered with zero gantry angle and between 95%–98% for real gantry angles. Dose difference between the TPS calculated and measured for IMRT delivered with zero gantry angle was found to be between (0.03 to 0.06Gy) and with real gantry angles between (0.02 to 0.05Gy). There is a significant difference between the gamma analysis between the zero degree and true angle with a significance of 0.002. Standard deviation of gamma pass percentage between the IMRT plans with zero gantry angle was 0.68 and for IMRT with true gantry angle was found to be 0.74. Conclusion: The gamma analysis for IMRT with zero degree gantry angles shows higher pass percentage than IMRT delivered with true gantry angles. Verification plans delivered with true gantry angles lower the verification accuracy when 2D array is used for measurement.

60 APPLIED LIFE SCIENCES↗

WMC Database Evaluation. Case Study Report

The WMC Database is ultimately envisioned to hold a collection of experimental data, design information, and information from computational models. This project was a first attempt at using the Database to access experimental data and extract information from it. This evaluation shows that the Database concept is sound and robust, and that the Database, once fully populated, should remain eminently usable for future researchers.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Cost Effectiveness Analysis of Quasi-Static Wireless Power Transfer for Plug-In Hybrid Electric Transit Buses: Preprint

This study evaluates the costs and benefits associated with the use of a plug-in hybrid electric bus and determines the cost effectiveness relative to a conventional bus and a hybrid electric bus. A sensitivity sweep analysis was performed over a number of a different battery sizes, charging powers, and charging stations. The net present value was calculated for each vehicle design and provided the basis for the design evaluation. In all cases, given present day economic assumptions, the conventional bus achieved the lowest net present value while the optimal plug-in hybrid electric bus scenario reached lower lifetime costs than the hybrid electric bus. The study also performed parameter sensitivity analysis under low market potential assumptions and high market potential assumptions. The net present value of plug-in hybrid electric bus is close to that of conventional bus.

33 ADVANCED PROPULSION SYSTEMS↗

Pulmonary Inflammatory Responses To Acute Meteorite Dust Exposures - Implications For Human Space Exploration

The previous manned missions to the Moon represent milestones of human ingenuity, perseverance, and intellectual curiosity. However, one of the major ongoing concerns is the array of hazards associated with lunar surface dust. Not only did the dust cause mechanical and structural integrity issues with the suits, the dust 'storm' generated upon reentrance into the crew cabin caused "lunar hay fever" and "almost blindness" (Figure 1). It was further reported that the allergic response to the dust worsened with each exposure. The lack of gravity exacerbated the exposure, requiring the astronauts to wear their helmet within the module in order to avoid breathing the irritating particles. Due to the prevalence of these high exposures, the Human Research Roadmap developed by NASA identifies the Risk of Adverse Health and Performance Effects of Celestial Dust Exposure as an area of concern. Extended human exploration will further increase the probability of inadvertent and repeated exposures to celestial dusts. Going forward, hazard assessments of celestial dusts will be determined through sample return efforts prior to astronaut deployment. Studies on the lunar highland regolith indicate that the dust is not only respirable but also reactive, and previous studies concluded that it is moderately toxic; generating a greater response than titanium oxide but a lower response than quartz. The presence of reactive oxygen species (ROS) on the surface of the dust has been implicated. However, there is actually little data related to physicochemical characteristics of particulates and pulmonary toxicity, especially as it relates to celestial dust exposure. As a direct response to this deficit, the present study evaluates the role of a particulate's innate geochemical features (e.g., bulk chemistry, internal composition, morphology, size, and reactivity) in generating adverse toxicological responses in vitro and in vivo. This highly interdisciplinary study evaluates the relative toxicity of six meteorite samples representing either basalt or regolith breccia on the surfaces of the Moon, Mars, and Asteroid 4Vesta; three potential candidates for future human exploration or colonization. Terrestrial mid-ocean ridge basalt (MORB) is also used for comparison as a control sample.

Harrington, A. D.↗