MFRED, 10 second interval real and reactive power for groups of 390 US apartments of varying size and vintage

Abstract Building electricity is a major component of global energy use and its environmental impacts. Detailed data on residential electricity use have many interrelated research applications, from energy conservation to non-intrusive load monitoring, energy storage, integration of renewables, and electric vs. fossil-based heating. The dataset presented here, Multifamily Residential Electricity Dataset (MFRED), contains the electricity use of 390 apartments, ranging from studios to four-bedroom units. All apartments are located in the Northeastern United States (IECC-climate-zone 4 A), but differ in their heating/cooling system and construction year (early to late 20 th century). To adhere to privacy guidelines, data were averaged across 15 apartments each, based on annual electricity use. MFRED includes real and reactive power, at 10-second resolution, for January to December 2019 (246 million data points). The annual average real power per apartment is 343 W (3.27 W/m 2 of floor area), with strong variation between seasons and apartment size. Considering its large number of apartments, high time resolution, real and reactive power, and 12-month duration, MFRED is currently unique for the multifamily-sector.

97 MATHEMATICS AND COMPUTING↗

Model of ramp compression of diamond from ab initio simulations

Ramp compression experiments characterize high-pressure states of matter at temperatures well below those present in shock compression. However, because temperature is typically not directly measured during ramp compression, it is uncertain how much heating occurs under these shock-free conditions. Here, we performed a series of ab initio simulations on carbon in order to match the density-stress measurements of Smith et al. [Smith et al., Nature (London) 511, 330 (2014)]. We considered isotropically as well as uniaxially compressed solid carbon in the diamond and BC8 phases, with and without defects, as well as liquid carbon. Our idealized model ascribes heating during ramp compression to an initially uniaxially compressed cell transforming isochorically into an isotropically (hydrostatic equivalent) compressed state having lower internal energy, hence higher temperature so as to conserve energy. Multiple such heating events can occur during a single ramp experiment, leading to higher temperatures than with isentropic compression. Comparison with experiments shows that heating alone does not explain the equation of state measurements on diamond, instead implying that a significant uniaxial stress component remains present at high compression. The temperature predictions of our ramp compression model remain to be verified with future laboratory measurements.

58 GEOSCIENCES↗

Global and regional perspectives on optimizing thermo-responsive dynamic windows for energy-efficient buildings

Architectural thermo-responsive dynamic windows offer an autonomous solution for solar heat regulation, thereby reducing building energy consumption. Previous work has emphasized the significance of thermo-responsive windows in hot climates due to their role in solar heat control and subsequent energy conservation; conversely, our study provides a different perspective. Through a global-scale analysis, we explore over 100 material samples and execute more than 2.8 million simulations across over two thousand global locations. World heatmap results, derived from well-trained artificial neural network models, reveal that thermo-responsive windows are especially useful in climates where buildings demand both heating and cooling energy, whereas thermo-responsive windows with optimal transition temperatures show no dynamic features in most of low-latitude tropical regions. Additionally, this study provides a practical guideline and an open-source mapping tool to optimize the intrinsic properties of thermo-responsive materials and evaluate their energy performance for sustainable buildings at various geographical scales.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Peak Demand Limiting and Optimization of HVAC Systems for Common Areas in High-Rise Multi-Family Housing (CRADA 518)

This project aims to create an innovative energy saving solution that is affordable and easy to implement. Initially, the proposed solution will fulfill an existing need for HVAC systems that serve multi-family housing. However, the solution can be easily expanded to other markets such as large hospitals, hotels, and commercial buildings. The proposed solution will be creatively packaged so that it can work where peak demand charge is high or where goal is to conserve energy and reduce carbon footprint. Of course, both Peak Demand Limiting (PDL) and Set-point optimization (SPO) can also operate simultaneously.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Oklahoma State University – Industrial Assessment Center (Final Report)

Our first primary objective is to provide industrial assessments to clients in Oklahoma, Arkansas, Kansas, and north and northwest Texas, including the Texas Panhandle (about 10% of the state of Texas). This geographical region extends about 400 miles north and south and about 600 miles east and west. In addition, the partnership links two universities, Oklahoma State University (OSU) and Wichita State University (WSU) within our region together in a significant collaboration focused on improving our region’s industrial competitiveness. Our second primary objective is to produce competent, motivated energy engineers. Student training will be a combination of classroom work, individual mentoring, and on-the-job training. The focus will be on energy conservation technologies, in conjunction with increased productivity, the economics of the same, and client relationships including client recruiting, on-site assessment, reporting, and client-related communications. Finally, we will work to provide resources and expertise to complement the first two primary objectives. The effectiveness and efficiency of our IAC will be measured, internally, by four broad criteria: (1) client benefits, (2) student development and acceptance after graduation, (3) regional/national contribution to lowering energy use and reducing pollutants, and (4) compliance with DOE/FM requirements. Client-related benefits include client contacts, timeliness of assessments and reports, the value of recommendations provided, and the value of recommendations implemented. Student development includes many students trained and the level of training provided in energy, waste, and productivity-related technologies as well as teamwork and communication skills. The contribution to lower national energy use and waste production is a natural outcome of the program. Compliance with DOE/FM requirements includes timeliness of reports, participation in Best Practices activities, contributions to EERE goals and objectives, and other requirements as communicated to the IAC.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeled Retrofit Package Performance for Schools

This report details modeled energy performance and savings from retrofit packages in prototypical school buildings in climate zones throughout the U.S. The information herein serves as a reference for elementary and secondary schools interested in implementing retrofit packages in their facilities for energy savings as well as health and safety benefits. School models developed for simulating package performance differentiated between rural and urban environments. Simulations were run for 10 distinct climate zones covering a range of climate conditions throughout the U.S. Results include savings estimates for electricity, natural gas, CO 2 emissions, and annual utility costs for nine different retrofit packages that combine energy conservation measures, including HVAC controls and equipment upgrades, lighting efficiency upgrades, and electrification technologies such as heat pumps for space conditioning and domestic hot water. Nine additional retrofit packages were also developed for elementary schools and modeled in two climate zones. Appendix B describes the additional retrofit packages and presents savings estimates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Savings Performance Contract Energy Sales Agreements

An energy savings performance contract energy sales agreement - referred to as an ESPC ESA or ESPC with an ESA - is a project structure that uses the multiyear ESPC authority to implement distributed energy projects on federal buildings or land. The distributed energy project implemented under an ESPC ESA is referred to as an ESA energy conservation measure, or ESA ECM.

ENERGY PLANNING, POLICY, AND ECONOMY↗

General framework for quantifying dissipation pathways in open quantum systems. III. Off-diagonal subsystem–bath couplings

This paper extends the previously reported theory of dissipation pathways [C. W. Kim and I. Franco, J. Chem. Phys. 160, 214111 (2024)] to incorporate off-diagonal subsystem–bath coupling, which is often required to model molecular systems where the environment directly influences transitions and couplings between subsystem states. We systematically derive master equations for both population transfer and dissipation into individual bath components, for which we also rigorously prove energy conservation and detailed balance. The approach is based on second-order perturbation theory with respect to the subsystem–bath couplings, whose form is not limited to any specific model. The accuracy of the developed method is tested by applying it to diverse model Hamiltonians involving linearly coupled harmonic oscillator baths and comparing the outcomes against the hierarchical equations of motion (HEOM) method. Overall, our method accurately quantifies the contributions of specific bath components to the overall dissipation while significantly reducing the computational cost compared to numerically exact methods such as HEOM, thus offering a path to examine how vibronic interactions steer non-adiabatic processes in realistic chemical systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simulation-Based Analysis of Impacts of Reduced Envelope and Duct Air Leakage on Indoor Air Pollutant Concentrations in Occupied Manufactured Homes

This report presents a simulation-based analysis that estimates the magnitude of indoor air pollutant concentration changes that could result from the proposed energy conservation standards. The analysis was conducted for a 1568 ft 2 , double-wide MH with variations in heating and cooling equipment (either furnace + air conditioner or heat pump) and various types of whole-house mechanical ventilation (continuous exhaust fan or central fan integrated supply), in three locations with varying climate conditions: Chicago IL, Fresno, CA; and Houston TX. The simulations tracked four air pollutants that can reach levels exceeding established safe target levels in homes: acrolein, formaldehyde, fine particulate matter (PM 2.5 ), and nitrogen dioxide (NO 2 ). The simulations considered acrolein and formaldehyde emitted from continuous indoor sources; acrolein, NO 2 and PM 2.5 from cooking; PM 2.5 from dispersed occupant activities; and NO 2 and PM 2.5 from outdoors, using historical data to identify typical levels. The impacts in homes operating or not operating whole-house mechanical ventilation equipment, kitchen and bath exhaust fans, and window opening as ventilation approaches were examined.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mode transitions and spoke structures in E × B Penning discharge

Two-dimensional particle-in-cell simulations in the (radial-azimuthal) plane perpendicular to the axial direction of a cylindrical $E$ x $B$ Penning discharge are presented. The low-pressure discharge is self-consistently supported by plasma ionization from the electron beam injected axially, along the direction of the external magnetic field. It is shown that with the increasing strength of the external magnetic field, the discharge undergoes a sequence of transitions between several azimuthal modes. Azimuthal m > 1 spiral arm structures are excited at low magnetic field values as plasma confinement improves and the radial density profile becomes peaked. With a larger field, spiral arms with m > 1 are replaced by the m = 1 spoke mode, most clearly seen in plasma density. A transition from spiral arms to the spoke regime occurs when the plasma potential in the center changes from weakly positive (or zero) to negative. Further increase in the magnetic field results in a well-developed m = 1 spoke mode with additional small-scale higher-frequency m > 1 structures inside and around the spoke. It is shown that while ionization and collisions affect some characteristics of the observed fluctuations, the basic features of the spoke and m > 1 spiral structure remained similar without ionization. The role of energy conservation in small-scale high-frequency modes and spoke dynamics is discussed. It is demonstrated that in regimes with the m = 1 spoke mode, additional m = 4 harmonics of the ion and electron fluxes to the wall appear due to the square boundary. The frequency of the m = 1 mode is weakly affected by the geometry of the boundary.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An implicit particle code with exact energy and charge conservation for electromagnetic studies of dense plasmas

A collisional particle code based on implicit energy- and charge-conserving methods is presented. A modified version of the particle-suppressed Jacobian-Free Newton-Krylov method that can enhance the solver efficiency is introduced. Mathematically, it is shown that this new approach can be viewed as a fixed-point iteration method for the particle positions. The model can exactly conserve global energy and local charge and can efficiently use time steps larger than the plasma period. In conclusion, the algorithm's ability to simulate dense plasmas accurately and efficiently is quantified by simulating the dynamic compression of a plasma slab via a magnetic piston in 1D planar geometry.

97 MATHEMATICS AND COMPUTING↗

Next generation retrofit wall panels with integrated vacuum insulation panels

Approximately two-thirds of residential buildings in the United States were constructed before the Department of Energy established energy conservation measures. These buildings present major opportunities for improving energy efficiency, though retrofitting them remains technically and economically challenging. This study presents the development and the durability evaluation of an innovative retrofit panel system that integrates vacuum insulation panels (VIP) with a nail-base panel (called a retrofit insulated panel) to enhance thermal performance with minimal disruption to occupants and without altering standard nail-based panel installation practices. Hygrothermal simulations were conducted to assess the moisture behavior of wall assemblies before and after retrofit installation under varying water vapor control strategies and climate conditions. Results indicate that, with appropriate moisture control strategy, the retrofit system effectively prevents moisture accumulation, keeping mold index values and relative humidity levels below critical thresholds. Additionally, Guarded Hot Box testing was performed to compute the effective R-value of the panel under different coverage areas that demonstrates its effectiveness in enhancing both thermal and moisture performance in existing residential buildings.

Iffa, Emishaw [ORNL]↗

Renewable energy and biological conservation in a changing world

Without a shift to renewable energy sources, climate change will have adverse effects on many terrestrial and aquatic species. On the other hand, replacing fossil fuels with renewable energy will have different effects on wildlife, some negative. To protect biota, while navigating the complexities surrounding the transition to renewable energy, will require sharing knowledge between energy experts and wildlife experts, as well as policy makers and resource managers. This special issue is intended to advance the conversation. Interactions between renewable energy facilities and fauna are complex. Each source of renewable energy has its own conservation concerns, and each presents its own set of opportunities for mitigation; Other concerns and mitigations are shared. In this overview, we review climate risks to biota, clarify the complementarities among renewables for the conservation community, and summarize research on energy effects on biota for the energy community. The papers invited for this special issue address fossil (coal, oil, natural gas) and renewable energy (terrestrial biomass energy, hydropower, marine-hydrokinetic energy, wind energy, solar energy) and affected fauna. Finally, we hope that the results of these studies, and others like them, set us on a path toward low-carbon energy systems that provide society with energy while protecting future biodiversity.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

HydraGNN v5.0

HydraGNN v5.0 expands the code base into a more portable, scalable, and flexible framework for scientific graph learning, with particular strength in atomistic machine-learning interatomic potentials and large-scale distributed training. The release adds Fully Sharded Data Parallel (FSDP) support alongside existing DDP and DeepSpeed paths, including FSDP-aware checkpointing and optimizer integration, and introduces a configurable multi-precision training workflow supporting FP32, BF16, and FP64 across GPUs and Intel XPUs. For atomistic modeling, HydraGNN v5.0 strengthens its MLIP capabilities through dynamic graph construction at every forward pass, energy-conserving force prediction via automatic differentiation, and per-atom energy loss formulations, while extending EGNN models to properly handle periodic boundary conditions. The release also broadens model expressiveness through graph-level attribute conditioning, adds new multi-task and model-parallel extensions such as MACE support and encoder/decoder branch optimization, and expands application coverage with integrated examples for datasets including OC25, Nabla2-DFT, QCML, Open Polymers 2026, and OPF. In parallel, HydraGNN v5.0 improves production readiness through performance optimizations for large-scale runs, stratified sampling and linear-regression preprocessing utilities, and tested installation scripts for DOE supercomputers including Frontier, Aurora, Perlmutter, and Andes. Overall, the release advances HydraGNN as a robust software platform for scalable graph neural networks across materials science, chemistry, and scientific machine learning workflows

Lupo Pasini, Massimiliano [Oak Ridge National Labo↗

Characteristics of Ultralow Aspect Ratio Toroidal Plasmas and Non-Solenoidal Startup and Edge Stability Studies at Near-Unity Aspect Ratio (Final Report)

This grant supported a long-term research and development program to explore the physics and technology of spherical tokamak (ST) plasma behavior at near-unity aspect ratio ( A ). The PEGASUS Toroidal Experiment is a university-scale ( R ) ~ 0.40 m, α ~ .35 m, I p ≤ 0.3 MA, B T ≤ 0.15 T) experiment that accesses A → 1, to provide large values of the normalized plasma current, I N = I p /α B T , or equivalently the toroidal field utilization factor I p / I TF . The research activities focused on: 1) developing the technique of Local Helicity Injection (LHI) as a viable means of initiating and growing an ST plasma without the use of a central solenoid; 2) exploring the equilibrium and stability properties of spherical tokamak plasmas at extremely low aspect ratio; and 3) obtaining new insights in the properties of the enhanced confinement H-mode regime at A ~ 1. The initial (Phase I) facility employed a unique high-stress central solenoid Ohmic for current drive and heating with simple magnet current waveforms. A subsequent major upgrade (Phase II) offered more flexible control of the plasma evolution along with a powerful LHI system for plasma initiation, heating and sustainment. The LHI technique consists of injection of high-density current streams into vacuum toroidal and vertical magnetic fields. These streams become unstable and support magnetic reconnection to allow the system to relax into a tokamak-like magnetic configuration. This program focused on: 1) development of electron current sources that provide sufficiently high injection currents in the challenging edge plasma region; 2) validation of theoretical limits to achievable I p arising from magnetic helicity and energy conservation plus absolute limits arising from relaxation to a minimal energy states; 3) tests of a power balance model to describe the evolution of the plasma current I p (t); and 4) study of magnetic fluctuations and their role in the I p evolution. This culminated in the production of toroidal currents of I p ≥ 0.2 MA with only ~8 kA of injected current. Operation with Ohmic induction alone in Phase I created plasmas with soft limits on the achievable I p and field utilization ( I p / I TF ~ 1) due to the onset of large low-order (2/1 or 3/2) internal resonant tearing modes. With the expanded capabilities in Phase II operation, methods employed to mitigate those modes and achieve I p / I TF > 1 were: 1) I TF ramp-downs; 2) non-solenoidal startup via LHI; and 3) extremely low I TF Ohmic operations assisted by LHI current injector pre-ionization. Extensive use of LHI-driven startup and drive for non-solenoidal operation produced favorable current profiles to stably operate tokamak plasmas with unprecedentedly high I N = I p / aB T ~ 15 and I p / I TF > 2. With strong reconnection-driven anomalous ion heating, this in turn provided access to tokamak plasmas with B t up to 100%, a world record 2 times higher than that previously achieved in advanced or spherical tokamaks. This high B t regime had a large fraction (~50%) of the plasma volume in a region of an absolute minimum- B configuration. The MHD stability limit in this regime was the ideal external kink mode without a stabilizing wall. These results provided the first demonstration of access to tokamak plasmas with very high B t , high i N , high elongation κ, and low internal inductance ℓ i , and as such served as a proof-ofprinciple for access to this long-sought ST regime. The naturally low B T needed for stability at A ≤ 1.2 reduces the L-H mode power threshold, P LH , so that H-mode plasmas were achieved with Ohmic heating alone. The power threshold for the transition to the H-mode regime was found to be 10× the accepted values from the ITER international scaling, confirming initial trends indicated by experiments on MAST and NSTX, and suggesting that the physics behind this transition is not yet fully understood. The density dependence of the transition and the observed insensitivity to whether the plasma is bounded by a limiter or magnetic divertor are consistent with the recent FM 3 model. Multiple unstable toroidal magnetic modes were measured during ELM (Edge Localized Mode) crashes, with generally lower toroidal mode numbers than seen at higher A , which was attributed to the larger peeling mode instability drive at low A . First-ever edge current profile measurements through an ELM crash showed current-carrying filaments were generated, as seen in ELM simulations and in electromagnetic blob transport theory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Environmental Impact of Deep Energy Retrofits in Residential Construction

Almost two thirds of the residential homes in the U.S. were constructed before the Department of Energy implemented energy conservation measures that were later formalized in the building codes. To reduce energy consumption and carbon emissions from the built environment, improvement to the existing housing stock is a prerequisite. However, improvements that lower energy consumption address carbon emissions related to heating, cooling and plug loads but not the embodied carbon of the building materials that also contribute to global carbon emissions. As the enclosure is made more efficient a larger portion of total carbon emissions is embodied carbon from the building materials. To mitigate carbon emissions, a holistic approach is required so that any improvement to the home results in a net reduction in carbon emissions. To understand the overall environmental impact of building enclosure improvements, the embodied and operational carbon emissions are calculated in this investigation and compared to the overall energy savings associated with enclosure improvements. The energy savings together with a reduction in operational carbon emissions are calculated using a novel building envelope metric. The net carbon emissions are then determined before and after the energy improvement measures. This approach allows or enables architects and builders to select designs that result in maximizing the overall reduction in energy and carbon emissions.

Aldykiewicz Jr, Antonio↗

Conservation laws in coupled cluster dynamics at finite temperature

We extend the finite-temperature Keldysh non-equilibrium coupled cluster theory (Keldysh-CC) [A. F. White and G. K.-L. Chan, J. Chem. Theory Comput. 15, 6137–6253 (2019)] to include a time-dependent orbital basis. When chosen to minimize the action, such a basis restores local and global conservation laws (Ehrenfest’s theorem) for all one-particle properties while remaining energy conserving for time independent Hamiltonians. We present the time-dependent Keldysh orbital-optimized coupled cluster doubles method in analogy with the formalism for zero-temperature dynamics, extended to finite temperatures through the time-dependent action on the Keldysh contour. To demonstrate the conservation property and understand the numerical performance of the method, we apply it to several problems of nonequilibrium finite-temperature dynamics: a 1D Hubbard model with a time-dependent Peierls phase, laser driving of molecular H2, driven dynamics in warm-dense silicon, and transport in the single impurity Anderson model.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a simplified calibrated building simulation model of a supermarket for proposed ECMs and control strategies impact evaluation

Calibrated building energy simulation is an important pathway to more energy-efficient buildings, but the information requirements of some approaches to this problem are significant. This is particularly true for supermarkets and other so-called “big-box” retail stores. Another characteristic of supermarkets is the significant interaction between Heating Ventilating and Air Conditioning (HVAC) and refrigeration systems in these buildings. These buildings could contain a wide variety of systems and a degree of load diversity that makes calibrated modeling a challenge. This paper describes a simplified approach that uses OpenStudio and EnergyPlus to combine known building parameters with “typical” parameters, resulting in a simplified building that is amenable to calibration. This approach was applied to a big-box store located in Nashville, Tennessee, and a calibrated model was obtained that was used to study potential energy conservation measures. Further, the paper also explores the capabilities of whole-building energy modeling tools, such as EnergyPlus, for modeling the HVAC controls and sequences and their impact evaluation. Although some measures are precluded by the model simplicity, several measures were found to improve the efficiency of the model and demonstrate that the simplified modeling approach is effective. Practical Application: This paper introduces a hybrid approach of building energy model calibration using limited information available from the actual building in combination with characteristics of a “typical” building of the same type. This hybrid approach would also be applicable for other building types than discussed in this paper to calibrate the building energy model using limited information from the actual building.

42 ENGINEERING↗