Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Hexagonal boron nitride: Epitaxial growth and device applications

As a newest family member of the III-nitrides, BN is considered amongst the remaining frontiers in wide energy bandgap semiconductors with potentials for technologically significant applications in deep UV (DUV) optoelectronics, solid-state neutron detectors, electron emitters, single photon emitters, switching/memory devices, and super-capacitors. It was shown that it is possible to produce h-BN epilayers with high hexagonal phase purity, UV transparency, and film stoichiometry by employing nitrogen-rich growth conditions. The quasi-2D nature of h-BN supports unusually strong optical transitions near the band edge and a large exciton binding energy on the order of 0.7 eV. Since the isotope of B-10 has a large capture cross-section for thermal neutrons, h-BN is an ideal material for the fabrication of solid-state neutron detectors for special nuclear materials detection, well and geothermal logging, and medical imaging applications. Freestanding B-10 enriched h-BN (h- 10 BN) epilayers with varying thicknesses up to 200 μm have been successfully synthesized by metal organic chemical vapor deposition (MOCVD) as of this writing. By utilizing the conductivity anisotropy nature of h-BN, 1 cm 2 lateral detectors fabricated from 100 μm thick h-10BN epilayers have demonstrated a detection efficiency of 59% for thermal neutrons, which is the highest on record among all solid-state neutron detectors as of today. It was noted that high growth temperatures, long growth times and the use of sapphire substrate tend to incorporate oxygen related impurities into h- 10 BN epilayers, which strongly impacted the carrier mobility-lifetime (μτ) products and charge collection efficiencies of h- 10 BN neutron detectors. As the h-BN material technology further develops, improved carrier mobilities and μτ products will allow the fabrication of h-BN devices with enhanced performance.

42 ENGINEERING↗

Overview of the front-end electronics of CMS HGCal - including readout and powering

The end-cap calorimeters of CMS will be upgraded to a single High Granularity Calorimeter (HG-Cal) for the HL-LHC, including both silicon sensors and scintillator tiles with on-tile SiPMs as active elements. The readout of the active elements is performed by an ASIC (HGCROC in 130 nm CMOS technology) that measures the amplitude and arrival time of the signals. The amplitude is measured over a large dynamic range to allow calibration with single particles and the measurement of TeV showers. The time of arrival of high-energy showers will be measured with a precision of around 30 ps. A second pair of “concentrator” ASICs - ECON-T and ECON-D - takes the data from the HGCROC channels and packages them for transmission via optical links to the off-detector electronics. The ECON-T transmits trigger data at 40 MHz, to form part of the level-1 trigger. The ECON-D transmits concentrated data packets at up to 1 MHz, upon reception of a level-1 trigger signal. In addition to these ASICs, HGCal will use modified versions of common HL-LHC electronics developments, for the power chain and the optical control and readout. The dense nature of the HGCal provides additional challenges for the electronic boards and cabling. In this proceedings the overall HGCal front electronics scheme, including the latest performance of the HGCROC and ECON ASICs is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging nanoscale carrier, thermal, and structural dynamics with time-resolved and ultrafast electron energy-loss spectroscopy

Time-resolved and ultrafast electron energy-loss spectroscopy (EELS) is an emerging technique for measuring photoexcited carriers, lattice dynamics, and near-fields across femtosecond to microsecond timescales. When performed in either a specialized scanning transmission electron microscope or ultrafast electron microscope (UEM), time-resolved and ultrafast EELS can directly image charge carriers, lattice vibrations, and heat dissipation following photoexcitation or applied bias. Yet, recent advances in theoretical calculations and electron optics are often required to realize the full potential of ultrafast EEL spectrum imaging. Here, in this review, we present a comprehensive overview of the recent progress in the theory and instrumentation of time-resolved and ultrafast EELS. We begin with an introduction to the technique, followed by a physical description of the loss function. We outline approaches for calculating and interpreting ground-state and transient EEL spectra spanning low-loss plasmons to core-level excitations analogous to x-ray absorption. We then survey the current state of time-resolved and ultrafast EELS techniques beyond photon-induced near-field electron microscopy, highlighting abilities to image carrier and thermal dynamics. Finally, we examine future directions enabled by emerging technologies, including electron beam monochromation, in situ and operando cells, laser-free UEM, and high-speed direct electron detectors. These advances position time-resolved and ultrafast EELS as a critical tool for uncovering nanoscale dynamic processes in quantum materials and solar energy conversion devices.

Computational methods↗

Atomic structures determined from digitally defined nanocrystalline regions

Nanocrystallography has transformed our ability to interrogate the atomic structures of proteins, peptides, organic molecules and materials. By probing atomic level details in ordered sub-10 nm regions of nanocrystals, scanning nanobeam electron diffraction extends the reach of nanocrystallography and in principle obviates the need for diffraction from large portions of one or more crystals. Scanning nanobeam electron diffraction is now applied to determine atomic structures from digitally defined regions of beam-sensitive peptide nanocrystals. Using a direct electron detector, thousands of sparse diffraction patterns over multiple orientations of a given crystal are recorded. Each pattern is assigned to a specific location on a single nanocrystal with axial, lateral and angular coordinates. This approach yields a collection of patterns that represent a tilt series across an angular wedge of reciprocal space: a scanning nanobeam diffraction tomogram. Using this diffraction tomogram, intensities can be digitally extracted from any desired region of a scan in real or diffraction space, exclusive of all other scanned points. Intensities from multiple regions of a crystal or from multiple crystals can be merged to increase data completeness and mitigate missing wedges. It is demonstrated that merged intensities from digitally defined regions of two crystals of a segment from the OsPYL/RCAR5 protein produce fragment-based ab initio solutions that can be refined to atomic resolution, analogous to structures determined by selected-area electron diffraction. In allowing atomic structures to now be determined from digitally outlined regions of a nanocrystal, scanning nanobeam diffraction tomography breaks new ground in nanocrystallography.

36 MATERIALS SCIENCE↗

Quantitative Scanning Transmission Electron Microscopy for Materials Science: Imaging, Diffraction, Spectroscopy, and Tomography

Scanning transmission electron microscopy (STEM) is one of the most powerful characterization tools in materials science research. Due to instrumentation developments such as highly coherent electron sources, aberration correctors, and direct electron detectors, STEM experiments can examine the structure and properties of materials at length scales of functional devices and materials down to single atoms. STEM encompasses a wide array of flexible operating modes, including imaging, diffraction, spectroscopy, and 3D tomography experiments. This review outlines many common STEM experimental methods with a focus on quantitative data analysis and simulation methods, especially those enabled by open source software. The hope is to introduce both classic and new experimental methods to materials scientists and summarize recent progress in STEM characterization. The review also discusses the strengths and weaknesses of the various STEM methodologies and briefly considers promising future directions for quantitative STEM research.

36 MATERIALS SCIENCE↗

The incommensurate modulation of tetragonal tungsten bronze quantified by high resolution 4D STEM

Many members of the tetragonal tungsten bronze (TTB) family of oxides display an incommensurate periodic lattice distortion, the nature of which has been the subject of some controversy. Here we present a study of this structural modulation in the relaxor ferroelectric Ba 5 SmSn 3 Nb 7 O 30 (BSSN) by quantitative scanning transmission electron microscopy (STEM). Additionally, we characterize the modulation in BSSN by employing a fast, pixelated direct electron detector to perform high resolution phase contrast STEM imaging of the crystalline lattice. By quantitatively analyzing the images, we visualize the atomic structural correlations present in the material on both the cation and anion sublattices. This analysis reveals the incommensurate structure to have an octahedral tilting pattern and cooperative A2 site cation displacements, analogous to an Ama2 commensurate cell. Finally, we show that the modulation is composed of a structural motif with a period of 3 x $d_{1\bar{1}0}$ and modified by discommensurations, likely arise from frustrated octahedral tilting in the odd-valued periodicity.

Differential phase contrast↗

A method for crystallographic mapping of an alpha-beta titanium alloy with nanometre resolution using scanning precession electron diffraction and open-source software libraries

An approach for the crystallographic mapping of two-phase alloys on the nanoscale using a combination of scanned precession electron diffraction and open-source python libraries is introduced in this paper. This method is demonstrated using the example of a two-phase α/β titanium alloy. The data were recorded using a direct electron detector to collect the patterns, and recently developed algorithms to perform automated indexing and analyse the crystallography from the results. Very high-quality mapping is achieved at a 3 nm step size. The results show the expected Burgers orientation relationships between the α laths and β matrix, as well as the expected misorientations between α laths. A minor issue was found that one area was affected by 180° ambiguities in indexing occur due to this area being aligned too close to a zone axis of the α with twofold projection symmetry (not present in 3D) in the zero-order Laue Zone, and this should be avoided in data acquisition in the future. Nevertheless, this study demonstrates a good workflow for the analysis of nanocrystalline two- or multi-phase materials, which will be of widespread use in analysing two-phase titanium and other systems and how they evolve as a function of thermomechanical treatments.

36 MATERIALS SCIENCE↗

Electromagnetic wave absorption of multifunctional cementitious composites incorporating polyvinyl alcohol (PVA) fibers and fly ash: Effects of microstructure and hydration

Highlights: • The cementitious composite shows excellent wide-band electromagnetic wave absorption in a frequency range of 2–18 GHz. • The PVA fibers and the fly ash change the dielectric properties of the cementitious composite by Debye polarization. • The iron oxide of the cementitious binders contributes to the magnetic properties of the composites. • The impacts of the microstructure and the hydration of the cementitious composite on its microwave absorption are analyzed. This paper devises a novel method for the adjustment of the pore structure and the hydration of cement to improve the electromagnetic wave absorption of the cementitious composites incorporating polyvinyl alcohol (PVA) fibers and fly ash in a frequency range of 2–18 GHz. The underlying mechanism of the absorption is investigated to explore the possibility of the structural and functional integration of these composites. The electromagnetic parameters of the prepared cementitious composites and those of the raw materials are analyzed in a frequency range of 0.5–18 GHz. Moreover, the pore structure and the chemical environment of the cementitious composites are examined by mercury intrusion porosimetry (MIP), back-scattered electron detector (BSE), and X-ray photoelectron spectroscopy (XPS). The results indicate that the PVA fibers and the high-volume fly ash have a positive effect on electromagnetic wave absorption of the cementitious composites through the adjustment of their pore structure and hydration.

36 MATERIALS SCIENCE↗

Design and performance of a silicon–tungsten calorimeter prototype module and the associated readout

Here, we describe the details of a silicon–tungsten prototype electromagnetic calorimeter module and associated readout electronics. Detector performance for this prototype has been measured in test beam experiments at the CERN PS and SPS accelerator facilities in 2015/16. The results are compared to those in Monte Carlo Geant4 simulations. This is the first real-world demonstration of the performance of a custom ASIC designed for fast, lower-power, high-granularity applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

From Gargamelle to MINERvA: exploring the structure of the nucleon with neutrinos

Neutrino scattering experiments have been exploring the structure of the nucleon with Deep-Inelastic Scattering for over 50 years. Although hints of nucleon structure were available using CERN’s first neutrino beam in the 1960s, the study actually started quantitatively in the early 1970s with the Gargamelle heavy liquid bubble chamber that produced first neutrino confirmation of scaling. This study of nucleon structure continued with both bubble chambers and more massive electronic detectors that, with higher energy neutrino beams and $Q^2$ reach, examined the breaking of this scaling while testing Quantum Chromodynamics. Here, a significant factor when including neutrino explorations of nucleon structure in the overall picture is that to gather significant statistics, neutrino experiments have had to use heavier nuclear targets. It has been experimentally demonstrated that the structure of the nucleon in the nuclear environment is indeed different than the free nucleon structure. Understanding this modified structure has played an important part in the experimental and theoretical exploration of nucleon structure by neutrinos and is one of the important goals of the on-going MINERvA experiment at Fermilab.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Internship In ISR-1 [Slides]

ISR-1 is the Space Science and Applications division, so much of what we work with involves satellites, detectors, electronics, radiation, etc.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Refining Methods to Determine the Isotopic Composition of Uranium Particles by Laser Ablation MC-ICP-MS

We report on efforts to mitigate the generation of isotopic anomalies during the ablation of micrometer-sized uranium oxide particles and analysis by MC-ICP-MS. The results of testing on particles of U200 indicate that laser fluence and frequency can affect isotopic data produced by laser ablation, but no settings were tested that could eradicate the signal spiking effect and generation of anomalous isotopic data for 234U/238U and 236U/238U. These anomalies are more frequent in samples with higher 235U enrichments, which is expected given their higher abundances of 234U and 236U. Of the standards tested here, only U005-A was anomaly-free. Efforts to compare the laser traces for particles with normal and anomalous isotopic compositions showed subtle differences in the behavior of the 234U/238U and 236U/238U ratios. However, it would be challenging to identify anomalous data points from a population of unknowns using this distinction, i.e., this is unlikely to be diagnostic. Thus, using current analytical hardware, we cannot eradicate the signal spiking phenomenon and cannot unambiguously identify isotopic anomalies from laser ablation traces. Ultimately, laser ablation ICP-MS would either require dramatic improvement to the ablation process and generation of more homogenous aerosols and/or improvements to detector electronics to identify and correct for the spiking phenomenon. Even if the reliability of the technique could be improved, a broader question to address is whether current data quality is of a high enough standard for laser ablation MC-ICP-MS to be used as a complementary technique to LG-SIMS for Safeguards.

organic↗

Analysis and Mitigation of Pulse-Pile-Up Artifacts in Plasma Pulse-Height X-ray Spectra

Pulse pile-up in pulse-height energy analyzers increases when the incident rate of pulses increases relative to the inverse of the dead time per pulse of the detection system. Changes in the observed energy distributions with incident rate and detector-electronics-formed pulse shape then occur. Here, we focus on weak high energy tails in X-ray spectra, important for measurements on partially ionized, warm (50–500 eV average electron energy), pure hydrogen plasma. A first-principles two-photon pulse-pile-up model is derived specific to trapezoidal-shaped pulses; quantitative agreement is found between the measurements and the model’s predictions. The model is then used to diagnose pulse-pile-up tail artifacts and mitigate them in relatively low count-rate spectra.

2-photon↗

Electromagnetic flowmeter.

Transducer and electronic detector of electromagnetic flow meter for volumetric flow measurement for both electrically conducting and dielectric fluids

FLOW METER↗