Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron beams”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Broadband hard X-ray attosecond pulses from extremely chirped electron beams

Attosecond pulses from free-electron lasers have opened the doors to atomic site-specific studies of bound electronic dynamics on their natural, sub-femtosecond timescales. Key to their success has been electron beam shaping techniques enabling the generation of sub-femtosecond current spikes with peak currents on the order of 10 kA. We demonstrate in an RF linac the generation of current spikes with extreme chirps on the order of 350 MeV/micron, directly competitive with the chirps expected from beam-driven plasma wakefield accelerators. Leveraging chirp-taper compensation, we use these highly chirped beams to generate hard X-ray attosecond pulses with bandwidths exceeding 30 eV, a factor of two beyond previous demonstrations. We simultaneously present the first explicit experimental evidence of chirp-taper compensation in an attosecond XFEL, finding that optimal tapering improves the bandwidth and pulse energy by factors of two and five, respectively, for our conditions. In addition to the immediate utility of such broadband hard X-ray pulses, electron beams with such extreme chirps can be utilized for unique new experimental modalities by performing further compression after the undulators. Such post-lasing compression can enable subsequent superradiant light emission at longer wavelengths, or direct excitation of quantum systems with the beam's intense space-charge field for unique attosecond pump-probe possibilities.

43 PARTICLE ACCELERATORS↗

Comments on 'Pulsed electron beam emission in space' by Neubert et al. (1988)

Using the potentials measured by the Spacelab's Charge and Current Probe during beam ejections and the signature of the harmonic emissions generated by pulsed electron beams, Neubert et al. (1988) presented evidence that overdense electron beams (with electron density above 150,000/cu cm) can escape the near vicinity of the Shuttle. This paper supplements these results by presenting a further indication of the beam escape and propagation out to at least 200 m, using the whistler-mode wave signature obtained during the SL-12 electron beam ejection which occurred on DOY 213 of 1985 from 03:30 to 03:37 UT. The combined results support the hypothesis that overdense electron beams can and will escape from a spacecraft, contrary to predictions based upon idealized simulations of the injection process.

Farrell, W. M.↗

Rotational temperature determination in flowing nitrogen using an electron beam

The measurement of rotational temperature by the electron-beam fluorescence technique is investigated for temperatures between 78 K and 300 K by using the 0-0 band of the nitrogen first negative system. Existing methods for calculating the rotational temperature from electron-beam spectra result in values which are higher than the true temperature and the error increases with density and electron-beam current. The errors are believed to arise through neglect of the effects of secondary electrons. Excitation by low-energy secondary electrons can increase the population of the sparsely populated rotational ground states at the expense of the abundantly populated states. This secondary excitation is proposed as the cause of the error in the calculated rotational temperature and a theoretical study determines that the density and beam current govern the excitation rate. Rotational-temperature measurements are made in a flowing stream of nitrogen at a known temperature for a range of densities and beam currents.

Lillicrap, D. C.↗

Electron-beam flow visualization - Applications in the definition of configuration aerothermal characteristics.

Comparisons between flow visualization systems using electron-beam fluorescence, schlieren, and shadowgraph techniques illustrate the advantages associated with the electron beam. Specific applications of this method as an aid in defining the origin of erosion on a heat-transfer model are cited. Results of combined electron-beam oil-flow studies on configurations illustrate that the simultaneous definition of the external flow field and its surface flow can be obtained. Comparisons between the electron-beam oil-flow visualization method and phase-change coating heat-transfer tests on a shuttle ascent configuration indicate the complementary nature of these two testing techniques. Potential methods for improving the electron-beam technique are included.

Woods, W. C.↗

Strategies to overcome electron-beam issues in liquid phase TEM: Study of chemical processes

Abstract Liquid phase (or liquid cell) transmission electron microscopy (TEM) has become a powerful platform for in situ investigation of various chemical processes at the nanometer or atomic level. The electron beam for imaging can also induce perturbation to the chemical processes. Thus, it has been a concern that the observed phenomena in a liquid cell could deviate from the real-world processes. Strategies have been developed to overcome the electron-beam-induced issues. This article provides an overview of the electron-beam effects, and discusses various strategies in liquid cell TEM study of nucleation, growth, and self-assembly of nanoscale materials, where an electron beam is often used to initiate the reactions, and highly electron-beam-sensitive electrochemical reactions. Graphical abstract

Zheng, Wenjing↗

Multiple electron beam generation with different energies and comparable currents from a single cathode potential for high power traveling wave tubes (TWTs)

We present a technique for generating multiple electron beams with different energies and comparable currents from a single cathode stalk at a single potential using nested magnetically insulated coaxial diodes (MICDs). The application is for a multi-stream traveling wave tube. Particle-in-cell simulations are performed for an experimental parameter-based geometry where two thin-walled intense relativistic electron beams immersed in a strong uniform magnetic field propagate through a cylindrical vacuum channel. The analytically derived results are obtained by extending Fedosov’s solution for generating a hollow electron beam from an MICD on a cathode stalk in an infinite magnetic field. Two electron beams are generated and accelerated downstream assuming zero initial kinetic energy of the electrons from the cathodes. Results show both electron beam currents ranging from 66 to 2.8 kA with an energy difference ranging from 6% to 27% depending on voltages applied from 100 to 600 kV and the geometry of the two MICDs. An optimal geometry is a crucial factor in achieving the maximum energy difference between the electron beams for comparable currents. The analytical and numerical simulation results show good agreement. We are currently in the process of planning experiments using the electron beam accelerator (SINUS-6 at UNM) to validate the analytical and simulation results.

Islam, K. N. (ORCID:0000000214397710)↗

Selection of Target Thickness and Size of Drive Electron Beam for Ce+BAF Injector

A baseline concept for a continuous wave (CW) polarized positron injector was developed for the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. This concept is based on the generation of CW longitudinally polarized positrons by a high-current, polarized electron beam (1 mA, 130-370 MeV, and 90% longitudinal polarization) that passes through a rotating, water-cooled, tungsten target. The positron yield and longitudinal polarization are calculated for the 123 MeV Ce+BAF injector at the Low Energy Recirculator Facility (LERF). The longitudinal and transverse CEBAF acceptances, defined as an energy spread of less than 1% and a normalized emittance of less than 100 mm·mrad, have been used in these calculations. The impact of target thickness, transverse electron beam size, and electron beam energy on the yield and polarization of a positron injector is evaluated. The total energy deposited by the beams in the tungsten target and the peak energy density are calculated for different target thicknesses, electron beam sizes, and energies.

Ushakov, Andriy [Thomas Jefferson National Acceler↗

A determination of the current density in electron beams

Current gathering rotating probe techniques were used to examine the envelope shape and power density profile of electron beams used in electron beam welding devices. The electron power density contours which determine the shape of the weld vapor cavity, penetration, and local heat distribution were considered. A mathematical analysis consistent with a rotating probe technique necessary to determine the current density distribution (assumed symmetrically radial) in a cross-section of the beam is provided. An explanation of the experimental technique for obtaining data, a BASIC language computer program to determine the current density from the data, and a study indicating the level of confidence to be associated with results obtained are also provided. An example of the application of the analysis to some experimental electron beam data is included.

Beil, R. J.↗

Focusing of relativistic electron beams with permanent magnetic solenoid

Achieving strong focusing of MeV electron beams is a critical requirement for advanced beam applications such as compact laboratory x-ray sources, high gradient accelerators, and ultrafast electron scattering instrumentation. To address these needs, a compact radially magnetized permanent magnetic solenoid (PMS) has been designed, fabricated, and tested. The solenoid provides a compact and inexpensive solution for delivering high axial magnetic fields (1 T) to focus MeV electron beams. Field characterization of the solenoid demonstrates good agreement with analytical models, validating the PMS design. The electron beam test employs a high-brightness photoinjector to study the focusing properties of the PMS. The results indicate a focal length of less than 10 cm and a significant reduction in beam size with small spherical aberrations. Two application cases are evaluated: angular magnification in ultrafast electron diffraction setups and strong focusing for Compton scattering or other microfocus uses.

Electron diffraction↗

Anticathode effect on multimodal azimuthal oscillations in electron beam generated E×B plasma

Electron beam (e-beam) generated plasmas with applied crossed electric and magnetic (⁠E x B⁠) fields are promising for low-damage (gentle) material processing. However, these plasmas can be subject to the formation of plasma non-uniformities propagating in the ⁠E x B direction. These rotating plasma structures (or “spokes”) enhance the transport of charged species across the magnetic field, which can harm the gentle processing capability of the plasma. In this work, we investigate the role of electrostatically active boundaries on the spoke formation by incorporating a variable bias conducting boundary (known as an anticathode) placed on the axially opposite side of the cathode. Our findings indicate azimuthal mode suppression occurs when the anticathode is electron collecting. Furthermore, we show selective azimuthal mode suppression by biasing the anticathode to an intermediate potential between the cathode and anode potentials. In conclusion, these findings suggest a link between the axial electron confinement in the e-beam generated plasma and azimuthally propagating plasma structure formation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Space charge effects during the injection of dense electron beams into space plasmas

One-dimensional electrostatic particle simulations are used to investigate the injection and propagation of intense electron beams and the plasma response to the beam injection. Beam densities greater than about the plasma density are considered. It is shown that if the injection is continuous, most of the beam electrons are drawn back into the spacecraft because of the buildup of positive charge on the spacecraft. Those electrons which are able to propagate away from the spacecraft are emitted periodically because of space charge oscillations induced by electric fields associated with the beam. A substantial increase in the fraction and average energy of electrons which can propagate away can be obtained if the injection is changed to periodic pulses having width and period matched to the induced space charge oscillations.

Winglee, R. M.↗

Electron Beam Freeform Fabrication in the Space Environment

This viewgraph presentation describes the effect of microgravity on the fabrication of electron beam freeform (EBF) in aerospace environments. The contents include: 1) Electron Beam Freeform Fabrication (EBF3) Process Description; 2) Portable Electron Beam Freeform Fabrication System at NASA LaRC; 3) Electron Beam Freeform Fabrication in the Space Environment; 4) Effect of Gravity on Surface Tension; 5) Effect of Deposit Height on Cooling Path; 6) Microgravity Testing Aboard JSC's C-9; 7) Typical Test Flight Plates; 8) Direction and Height Trials for Process Control; 9) Effect of Wire Entry Direction into Molten Pool; 10) Microstructure of Single Layer EBF Deposits; 11) 0-g Deposit with Incorrect Standoff Distance; 12) Successful Demonstration of EBF in 0-g; and 13) Conclusion.

Taminger, Karen M.↗

VLF wave emissions by pulsed and dc electron beams in space. I - Spacelab 2 observations

The properties of radio waves generated by electron beams in space were investigated using data from the wideband wave receiver on the Spacelab 2. The VLF observations were found to confirm the results of the STS 3/OSS-1 mission. It was found that a 1-keV electron beam injected from the orbiter produced copious broadband electromagnetic emissions. When the electron beam was square-wave modulated, narrow-band emissions at the pulsing frequency and harmonics of that frequency were produced along with the broadband emissions. The observations indicated that dc 50-mA electron beams and pulsed 50-percent duty-cycle 100-mA beams produce broadband radiation which is comparable in intensity and spectral shape at all points for which the wave field was sampled.

Reeves, G. D.↗

Electron beam welder X-rays its own welds

Beam of an electron beam welder X rays its own welds, enabling rapid weld quality checks to be made without removing the work from the vacuum chamber. A tungsten target produces X rays when hit by the beam. They are directed at the weld specimen and recorded on polaroid film.

Roden, W. A.↗

Theoretical investigation of plasma wave generation by pulsed electron beams in space

Here, we report theoretical calculations of plasma wave generation in the whistler modes and in the extraordinary modes, by pulsed electron beams in a magnetized plasma. The numerical simulations of the wave generation take into account the longitudinal expansion of the electron beam due to the space charge force and the energy spread. The work presented in this article provides predictions for the wave generation performance of the beam plasma interactions experiment (Beam PIE), where pulsed electron beams were produced by a spaceborne radio frequency (RF) linear accelerator. We also theoretically explore the desirable properties of the pulsed electron beam for future space experiments, which will be the next step toward eventually demonstrating the radiation-belt remediation (RBR).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Low-Pressure Gas Effects on the Potency of an Electron Beam Against Ceramic Cloth

An 8-kv electron beam with a current in the neighborhood of 100 mA from the Ukrainian space welding "Universal Hand Tool" (UHT) burned holes in Nextel AF-62 ceramic cloth designed to withstand temperatures up to 1,427 C. The burnthrough time was on the order of 8 scc at standoff distances between UHT and cloth ranging from 6-24 in. At both closer (2 in.) and farther (48 in.) standoff distances the potency of the beam against the cloth declined and the burnthrough time went up significantly. Prior to the test it had been expected that the beam would lay down a static charge on the cloth and be deflected without damaging the cloth. The burnthrough is thought to be an effect of partial transmission of beam power by a stream of positive ions generated by the high-voltage electron beam from contaminant gas in the "vacuum" chamber. A rough quantitative theoretical computation appears to substantiate this possibility.

Nunes, A. C., Jr.↗

Wiggler-based electron beam microbunching amplifier study

The wiggler-based amplifier of the microbunching instability in the electron beam is considered and compared to a longitudinal space charge amplifier consisting of the drifts and chicanes. The gain in the magnitude of a seed perturbation of the electron beam density is evaluated analytically as a function of the period of the perturbation, the electron beam parameters, the wiggler parameters, and the amplifier lattice parameters. The theory is compared with the results of the numerical calculations of the gain based on simulations of the electron beam transport through the amplifier lattice. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

An Assessment of Molten Metal Detachment Hazards During Electron Beam Welding in Space

The safety issue has been raised with regards to potential molten metal detachments from the weld pool and cold filler wire during electron beam welding in space. This investigation was undertaken to evaluate if molten metal could detach and come in contact with astronauts and burn through the fabric of the astronauts' Extravehicular Mobility Unit (EMU) during electron beam welding in space. Molten metal detachments from either the weld/cut substrate or weld wire could present harm to a astronaut if the detachment was to burn through the fabric of the EMU. Theoretical models were developed to predict the possibility and size of the molten metal detachment hazards during the electron beam welding exercises at Low Earth Orbit (LEO). The primary molten metal detachment concerns were those cases of molten metal separation from the metal surface due to metal cutting, weld pool splashing, entrainment and release of molten metal due to filler wire snap-out from the weld puddle, and molten metal accumulation and release from the end of the weld wire. Some possible ways of obtaining molten metal drop detachments would include an impulse force, or bump, to the weld sample, cut surface, or filler wire. Theoretical models were developed for these detachment concerns from principles of impact and kinetic energies, surface tension, drop geometry, surface energies, and particle dynamics. The surface tension represents the force opposing the liquid metal drop from detaching whereas the weight of the liquid metal droplet represents a force that is tending to detach the molten metal drop. Theoretical calculations have indicated that only a small amount of energy is required to detach a liquid metal drop; however, much of the energy of an impact is absorbed in the sample or weld plate before it reaches the metal drop on the cut edge or surface. The tendency for detachment is directly proportional to the weld pool radius and metal density and inversely proportional to the surface tension of the liquid metal. For a detachment the initial kinetic energy of the weld pool with respect to the plate has to exceed the energy to form the extra surface required for the detachment of the pool. The difficulty is in transferring the energy from the point of impact through the plate and sample to the cut edge. It is likely that not all of the kinetic energy is available for detaching the pool; some may be sequestered in weld pool oscillations. The coefficient of restitution for the collision will be lower than one if irreversible deformation, for example plastic flow deformation, takes place during the collision. Thus determining the amount of energy from an impact that actually reaches the molten metal droplet is critical. Various molten metal detachment scenarios were tested experimentally in an enclosed vacuum chamber using the Ukrainian Universal Hand Tool, an electron beam welder designed for space welding. The experimental testing was performed in a 4 ft. X 4 ft. vacuum chamber at Marshall Space Flight Center, evacuated to vacuum levels of at least 50 microTorr, and also some welding garment material was utilized to observe the effect of the molten metal detachments on the material. A "carillon" apparatus consisting of four pendulum hammer strikers, each weighing approximately 3.65 lbs, raised to predetermined specific heights was used to apply an impact force to the weld sample/plate during electron beam welding and cutting exercises. The strikers were released by switching on an electric motor to rotate a pin holding wires retaining the strikers at desired heights. The specimens were suspended so as to be free to respond to the blows with a sudden velocity increment. The specimens were mounted on a hinged plate for minimizing effective mass with the option to fasten it down so as to raise its effective mass closer to that anticipated for an actual space welding scenario. Measurements were made of the impact energy and the horizontal fling distances of the detached metal drops. It was not particularly easy to generate the detachments for this experiment. This document presents the details of the theoretical modeling effort and a summary of the experimental effort to measure molten metal drop detachments from terrestrial electron beam welding in the enclosed vacuum chamber. The results of the experimental effort have shown that molten metal detachments can occur from the sample/weld plate only if a sufficiently large impact force is applied to the weld plate. A "weld pool detachment parameter" was determined to indicate whether detachment would occur. Detachment can be either full or partial (dripping), Partial detachment means that the weld pool detached from one side of the liquid-solid boundary so as to leave a hole at the puddle site but remained attached over part of the liquid-solid boundary and dripped down the plate with no fully detached material detected. Full detachment, however, does not necessarily mean that the whole pool fully detached; in some cases only a smaller portion of the pool detached, the remainder dripping down the plate. The weld pool detachment parameter according to theory and according to the empirical data allows a determination of whether full detachments might occur. Theoretical calculations indicated titanium alloy would be the most difficult from which to detach molten metal droplets followed by stainless steel and then by aluminum. The experimental results were for the most part consistent with the theoretical analysis and predictions. The above theory is applicable to other situations as desired for assessing the potential for molten metal detachments.

Fragomeni, James M.↗