Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electric power grid operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Oak Ridge National Laboratory Pilot Demonstration of an Attestation and Anomaly Detection Framework using Distributed Ledger Technology for Power Grid Infrastructure

This report summarizes the design and pilot demonstration of a framework called Grid Guard that was created to provide increased data and device trustworthiness to electric grid devices by leveraging distributed ledger technology (DLT), specifically blockchain. Grid Guard contains a combination of core cryptographic methods such as the secure hash algorithm (SHA), and asymmetric cryptography, private permissioned blockchain, baselining configuration data, consensus algorithm (Raft) and the Hyperledger Fabric (HLF) framework. The system implements a low energy, fast, and robust enhancement to system trustworthiness within and across electric grid systems such as substations, control centers and metering infrastructures. Blockchain is a distributed database structured that provides a practically unalterable (immutable) timeline of stored transactions. By relying on hashing and the Raft consensus algorithm, if an entity tries to illegitimately alter a record at one instance of the database the other ledger nodes are not altered. They work to cross-reference each other and easily locate any incorrectly added data and remove it. The bulk raw data is stored in an off-chain storage (outside of the blockchain ledger) and a hash of this baseline data is stored in the Blockchain ledger via hashing windows of time-series and configuration data, after aggregation and filtering. The bulk off-chain data repository is then considered to be trust-anchored using the hashes stored in the blockchain. To secure the electric grid testbed devices and data, device configuration baselines were compared to those baselines that had been previously stored in the ledger. Statistical baselines for device configurations, network communication patterns, and high-speed sensor data are calculated and then stored off-chain and hashes stored in the ledger. Measurements such as three-phase voltage and current, frequency, breaker status, protection scheme settings, network configuration settings (and other device configuration artifacts) and network traffic features (packet interarrival times) are compared every minute or other selected time windows. During phase 1 of the Grid Guard DLT project different DLT technologies were studies, and an assessment was performed on DLT technology vulnerabilities, uses, and key characteristics. DLT consensus protocols were studies (e.g., RAFT, named after Reliable, Replicated, Redundant, And Fault-Tolerant). Also, cryptography, public, private and permissioned or permissionless systems were assessed. Grid Guard implements a permissioned private DLT. Consensus algorithm selection and choice of DLT implementation depended heavily on the use-case. For this use-case, parameters were selected to measure performance and existing tools for assessment. Benchmarking was performed theoretically and practically. During phase 2 hashed transactions/blocks were inserted into the ledger every second. During phase 2 of the Grid Guard DLT project, a prototype framework was developed and demonstrated for attestation of critical substation devices and data using precision timing systems that use PTP and IRIG-B protocols) on a testbed of operational devices that emulated a distribution substation, control center, and power metering infrastructure using real Operational Technology (OT). The testbed includes OT devices such as protective relays, human machine interfaces (HMI), and power meters. To determine when to collect and compare system and network baselines, an initial examination of an anomaly detection capability to identify malicious manipulation of data streams was conducted. The resulting anomaly detection was demonstrated in a set of experiments and leveraged to trigger device artifact attestation checks. Attestation checks occur against device configuration baselines when compared with the immutable blockchain-stored baselines, which provided a cryptographically supported means by which to store baselines. The electrical substation-grid testbed was created to test the Grid Guard framework. The testbed emulates the operations of a portion of a power grid and SCADA systems as closely as possible. The testbed integrates real protocols, mainly IEC 61850 standard protocols, such as the Sampled Value (SV) and the GOOSE protocols. The testbed also supports DNP3 and other layer 2 and layer 3 protocols such as Telnet, SSH, SFTP/FTP and other proprietary protocols needed to connect to industrial control system equipment. The testbed emulates real power conditions using the OpalRT hardware-in-the-loop (HIL) device which can create fault situations that cannot be easily tested on real systems. The electrical substation-grid testbed was created using real measurement, communication, and protection devices that electrical utilities commonly use.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A review of energy storage for power system resilience: Functions, metrics, and applications

Aging infrastructure, increasing operational complexity, and surging electricity demand from artificial intelligence and electrification are straining the grid and heightening the risks of disruptions, making resilience a critical priority. Energy storage is increasingly deployed to provide critical power supply, fast grid support, and rapid restoration. However, current practice lacks consistent metrics and systematic methodologies to rigorously quantify the resilience benefits of storage. This paper provides a comprehensive review of energy storage in resilience enhancement, focusing on functional roles, quantification metrics, and integration strategies. A structured resilience metrics library is compiled and categorized to encompass both technical and economic performance aspects. Existing methodologies for resilience-oriented storage planning and operations are critically examined. Key technical and practical challenges are identified, and future research directions are outlined to strengthen storage contributions to grid resilience.

Benefit quantification↗

On the Impact of High-Order Harmonic Generation in Electrical Distribution Systems

The modern power grid has seen a rise in the integration of non-linear loads, presenting a significant concern for operators. These loads introduce unwanted harmonics, leading to potential issues such as overheating and improper functioning of circuit breakers. In pursuing a more sustainable grid, the adoption of electric vehicles (EVs) and photovoltaic (PV) systems in residential networks has increased. Understanding and examining the effects of high-order harmonic frequencies beyond $1.5$ kHz is crucial to understanding their impact on the operation and planning of electrical distribution systems under varying nonlinear loading conditions. This study investigates a diverse set of critical power electronic loads within a household modeled using PSCAD/EMTdc, analyzing their unique harmonic spectra. This information is utilized to run the time-series harmonic analysis program in OpenDSS on a modified IEEE 34 bus test system model. The impact of high-order harmonics is quantified using metrics that evaluate total harmonic distortion (THD), transformer harmonic-driven eddy current loss component, and propagation of harmonics from the source to the substation transformer.

Peerzada, Aaqib A. [BATTELLE (PACIFIC NW LAB)]↗

Renewable energy integration and system operation challenge: control and optimization of millions of devices

The electric power infrastructure, originally designed and built on large-scale power plants, is evolving into a more resilient power generation and delivery system in which millions of smaller units of distributed energy generation resources units will be installed in sub-transmission and distribution networks. In order to control, manage and optimize the future grid, a hierarchical design is presented in this chapter which enables the distributed control on grid edge while inheriting the existing centralized control structure. This layered design of large-scale power system operation and control uses the following principle: reactive power control is treated as a primary control for voltage stability, and the real power control is primarily a grid-level control but can also be a supplementary control for voltage support in the case of insufficient reactive power control capacity. For the purpose of active control and operation at the distribution level, a recursive power network model is derived from nodal injection and branch power flow models. Based on the model, the proposed algorithms of hierarchical control, grid-edge inference and dynamic hosting allowance are developed and presented for multi-level controlled operation. And, a co-simulation architecture of integrated T&D system is presented to validate and demonstrate the feasibility and scalability of proposed algorithms.

Xu, Ying↗

Understanding the Computing and Analysis Needs for Resiliency of Power Systems from Severe Weather Impacts

As the frequency and intensity of severe weather has increased, its effect on the electric grid has manifested in the form of significantly more and larger outages in the United States. This has become especially true for regions that were previously isolated from weather extremes. In this paper, we analyze the weather impacts on the electric power grid across a variety of weather conditions, draw correlations, and provide practical insights into the operational state of these systems. High resolution computational modeling of specific meteorological variables, computational approaches to solving power system models under these conditions, and the types of resiliency needs are highlighted as goal-oriented computing approaches are being built to address grid resiliency needs. An example analysis correlating outages to 1km day-ahead weather from two historical winter storms, calculated on a large cluster using a combination of interpolated and extrapolated inputs from multiple instrumented sites to workflows that produce primary meteorological outputs, is shown as initial proof of concept.

analysis↗

Communication Network Layer State Estimation Measurement Model for a Cyber-Secure Smart Grid

Network communication has been proven to be a very important tool and a key factor in the recent development and progress of the power grid operation. It is also considered as the foundation for the smart grid because information and communication are integrated into electricity distribution to achieve reliable and accurate knowledge of the power grid. In previous years, absorbing energy from substations and delivering it to customers was the only type of interaction we knew between utility companies and customers. Presently, the growing connections of small distributed generation units caused by the cost reduction of most of the technologies used in generation and storage of electrical energy, along with the potential benefits of renewable energy have pushed many researchers to look into the improvement of information and communication technologies (ICT) in order to ensure a bidirectional flow of power and data. Moreover, the evolution of information and communication technologies and its applications to smart grid have converted the smart grid into a cyber-physical system where vulnerabilities and additional security challenges such as cyber-threats and cyber-attacks have emerged. Previously, we have demonstrated that using machine learning-based processing on data gathered from communication networks and the power grid was a promising solution for detecting cyber threats by implementing a co-simulation of cyber-security for cross-layer strategy. Since the majority of the challenges observed can only be solved in the network communication layer, we present in this work a physics-based state estimation model of the communication network system towards enhanced cyber-physical security of the smart grid. Information integration with the previously developed machine learning model is developed, providing a enhanced cyber-physical security application for the smart grid. Easy-to-implement model, without hard-to-derive parameters, highlight potential aspects of the model for real-life applications.

Mathieu, Reynold↗

Impact of Non-Steady State Operation on Cooling Water Consumption at Coal- and Natural Gas-Fired Power Plants

Increased renewable energy penetration in the electricity grid in coming decades will result in more frequent cycling at thermal power plants. Simultaneously, thermal power plants may face water scarcity with declining availability of cooling water. Therefore, to enhance thermal power plants’ resiliency to water shortages it is important to understand how non-steady conditions due to cycling will impact cooling water consumption and withdrawal intensity. Non-steady operation at power plants has been previously shown to decrease power plant thermal efficiency. Energy balance models have also demonstrated that a decrease in thermal efficiency is expected to increase cooling water consumption intensity. Furthermore, past work has used operating hours data to show idling and cycling gaps where cooling systems operate more than corresponding generators. As a result, an increase in cycling behavior may impact cooling water consumption and withdrawal intensity. This study uses data from the Energy Information Administration (EIA) and Environmental Protection Agency (EPA) to quantify the impact of cycling cooling water consumption intensity for recirculating cooling systems and withdrawal intensity for once-through cooling systems using energy balance and statistical approaches. In a novel application of a fixed effects model to study the effect of temperature on cooling water consumption and withdrawal intensity, this study finds temperature was consistently expected to increase consumption intensity and withdrawal intensity. Non-steady state conditions do not increase cooling water consumption intensity with statistical significance across unit types. However, additional validation of cooling water data is required to confirm these observed trends due to the sensitivity of these findings to model form and concerns with data quality of the dependent variables, cooling water consumption and withdrawal.

20 FOSSIL-FUELED POWER PLANTS↗

How the U.S. Power Grid Kept the Lights on in Summer 2024

Maintaining the reliability of the bulk power system, which supplies and transmits electricity, is a critical priority of electric grid planners, operators, and regulators. As demand for electricity increases and the U.S. resource mix changes, how grid operators meet peak demand is changing. In summer 2024, grid operators in all regions maintained enough capacity to keep the lights and air conditioners on during periods of peak demand, even as older generators have been retired. And, an increasing number of regions used more solar and storage to meet peak demand. In this publication, we describe grid operations on the highest demand day in ERCOT and a few other regions and how solar and storage in particular worked together to help meet peak demand.

14 SOLAR ENERGY↗

Economic Dispatch Optimization of Multi-Unit SMR Site

With the increase of integration of variable renewable into the grid, grid resilience can be compromised without flexible electricity suppliers. Flexible operation of NPP can expand the scope of integration of new nuclear power plants in regions with high share of renewables. It also provides opportunity to increase profits through participation in ancillary services. In this research, NuScale modules are used as the case study. NuScale is an integrated pressurized water reactor with thermal power of 250 MWth. Having multiple units can provide higher flexibility in changing power levels and supplying the grid with electricity all year long. Additionally, load-following might perturbate the ordered sequence of refueling (every 24 months for NuScale). To maintain the 2 year refueling cycles, the loading patterns will need to be adjusted in a year-to-year basis, resulting in additional unnecessary costs. Another solution is to find the optimal outage schedule. This will also shift the focus of the planned outage to a more optimized predictive outages and maintenance. Results from short-term optimization (i.e., daily participation in energy and ancillary services markets) shows that average commitment to regulation down ancillary service markets during late night and early morning hours can increase revenues. Participating in upward reserves during pre-work commuting hours and early evening hours can also generate additional revenues due to high ramp up of electricity demand. Having multiple units at a single site can also help operate flexibly. Results from long-term optimization show that daily fluctuation in electric power is usually handled by few units while other units operate on base-load profile. It is possible to combine base-load operation with flexible operation to extend component remaining useful life in some units and find optimal outage schedule for the units.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Comparison of Long-Term Bioenergy with Carbon Capture and Storage to Reference Power Generation Technologies Using CO2 Avoidance Cost in the U.S.

Bioenergy with carbon capture and storage (BECCS) can sequester atmospheric CO2, while producing electricity. The CO2 avoidance cost (CAC) is used to calculate the marginal cost of avoided CO2 emissions for BECCS as compared to other established energy technologies. A comparative analysis using four different reference-case power plants for CAC calculations is performed here to evaluate the CO2 avoidance cost of BECCS implementation. Results from this work demonstrate that BECCS can generate electricity at costs competitive with other neutral emissions technologies, while simultaneously removing CO2 from the atmosphere. Approximately 73% of current coal power plants are approaching retirement by the year 2035 in the U.S. After considering CO2 sequestered from the atmosphere and coal power plant CO2 emissions displaced by BECCS, CO2 emissions can be reduced by 1.4 billion tonnes per year in the U.S. alone at a cost of $88 to $116 per tonne of CO2 removed from the atmosphere, for 10% to 90% of available biomass used, respectively. CAC calculations in this paper indicate that BECCS can help the U.S. and other countries transition to a decarbonized electricity grid, as simulations presented in this paper predict that BECCS power plants operate at lower CACs than coal plants with CCS.

25 ENERGY STORAGE↗

Conceptual Design of Pulverized Coal Electricity Generating Units for Flexible Operation

This presentation was given by Marc Turner, NETL Support Contractor, at the International Center for Sustainable Carbon's "The Energy Transition - the Role for Sustainable Carbon" workshop held in Sardinia, Italy on November 16-18, 2022. The presentation addresses the NETL report titled "Conceptual Design of Pulverized Coal Electricity Generating Units for Flexible Operation" published on September 6, 2022. This study presents an independent conceptual assessment of the features, cost, and performance of pulverized coal power plants (without carbon dioxide capture) intended for flexible, rather than baseload, operation. The objective was to leverage the already substantial knowledge base about flexible operation and develop state-of-the-art pulverized coal power plant cases that are designed to accommodate flexible operation within an electric grid having a high level of renewable generation. This is of significant importance in coal-dependent regions of the world as variable renewable energy becomes more prevalent.

Turner, Marc↗

Architecture for Quantum-in-the Loop Real-Time Simulations for Designing Resilient Smart Grids

With the power grid growing more complex every day with the inclusion of new sensors and regulatory approvals that enable end-users and small local developers to participate in the grid, it is becoming challenging for conventional smart grid simulation, emulation, and testing technologies to keep up. In this work, we propose that quantum-encoded real-time simulations can be helpful under the new paradigm and operational circumstances to solve optimization problems for power grids. By leveraging the principles of quantum mechanics, the proposed quantum-in-loop (QIL) framework will enable better and faster optimization solutions based on real-world, real-time data streams, facilitating the real-time planning and operations of electrical grids that rely on millions of distributed sensors and controllers. Furthermore, QIL will allow researchers and engineers to assist utilities in designing, developing, and de-risking algorithms to optimize power grid operation and resilience by considering inputs from millions of grid-connected devices. QIL framework is being developed to have a self-limiting triage mechanism, which will help engineers and practitioners identify fundamental physical limits on quantum processors, revealing what quantum algorithms can and cannot do in utility-specific use cases and must continue to count on classical high-performance computing infrastructure.

digital real-time simulation↗

Networked Microgrid Operations: Supporting a Resilient Electric Power Infrastructure

Modern electric power systems operate using large generating units managed with a centralized control structure. The current systems are the result of over a hundred years of technological development and consolidation to leverage economies of scale. While the existing systems have proven cost effective and reliable, modern systems are experiencing a wide range of operational challenges that are causing a reexamination of the centralized control structure. Despite the nearly universal adoption of centralized control, electric power systems are fractal in their operational requirements. Specifically, the fundamental operational requirements are the same, regardless of the system size. While past technologies have not allowed for exploitation of this fractal behavior, emerging technologies are making it possible; these technologies include grid-forming inverters, modern telecommunications systems, and distributed control architectures. Here we show emerging technologies that allow the fractal operational requirements of electric power systems to be exploited as networked microgrids to increase the resiliency of the world’s critical electrical infrastructure.

Schneider, Kevin P.↗

On the Feasibility of Market Manipulation and Energy Storage Arbitrage via Load-Altering Attacks

Around the globe, electric power networks are transforming into complex cyber–physical energy systems (CPES) due to the accelerating integration of both information and communication technologies (ICT) and distributed energy resources. While this integration improves power grid operations, the growing number of Internet-of-Things (IoT) controllers and high-wattage appliances being connected to the electric grid is creating new attack vectors, largely inherited from the IoT ecosystem, that could lead to disruptions and potentially energy market manipulation via coordinated load-altering attacks (LAAs). In this article, we explore the feasibility and effects of a realistic LAA targeted at IoT high-wattage loads connected at the distribution system level, designed to manipulate local energy markets and perform energy storage (ES) arbitrage. Realistic integrated transmission and distribution (T&D) systems are used to demonstrate the effects that LAAs have on locational marginal prices at the transmission level and in distribution systems adjacent to the targeted network.

25 ENERGY STORAGE↗

Field Verification of Grid-Forming Inverter-Based Power Plant Performance for Transmission System Reliability

This report describes some examples of the operation of two grid-forming (GFM) inverter-based photovoltaic-battery hybrid power plants connected to the electric system of the island of Kauai in Hawaii. Both plants are photovoltaic power plants with battery energy storage and are connected to the networked transmission system operated by Kauai Island Utility Cooperative (KIUC), along with several other power plants including an oil-fired plant, diesel generators, small hydroelectric plants, a biofuel plant, and several other photovoltaic plants.

14 SOLAR ENERGY↗

Seasonal Cost-Benefit Analysis of Automated Distribution Feeder Upgrades with Advanced Mitigation Technologies

The increasing deployment of distributed solar photovoltaics (DPV) to meet clean energy goals can trigger adverse grid operation issues, such as voltage excursions and the violation of thermal loading constraints of the power delivery elements (e.g., lines and transformers) on the evolving electricity infrastructure. Such integration issues would require distribution upgrades with associated costs to mitigate them and to maintain reliable and resilient grid operating conditions. Traditional distribution network upgrade approaches use a specific single snapshot analysis that is overly conservative. This study considers a multi-time point analysis to capture both moderate (probable bounds) and extreme grid operating conditions using time points such as minimum load with minimum photovoltaics (PV), maximum load with maximum PV, maximum load with minimum PV, and minimum load with maximum PV. Further, this study investigates seasonal variation impacts and associated distribution upgrade costs for a spring season case (March, representing a low load and high PV scenario) and a summer case (July, representing a high load and high PV scenario). Such seasonal analysis will allow system operators to characterize upgrade requirements and associated costs across various periods. Because the spatial distribution of DPV can impact upgrade and associated costs, this study investigates three common DPV deployment scenarios - randomly deployed, close to the substation, and far from the substation - at different penetration levels. Apart from spatial distribution impacts, this project evaluates the techno-economic impacts of the nodal photovoltaic penetration factor (NPPF) for generating the various DPV deployment scenarios at increasing penetration levels. This project investigates the impact of varying nodal PV-to-load ratios using conservative and extreme NPPF values of 3 and 10, respectively. This study investigates the deployment of traditional infrastructure upgrade strategies, such as installing new voltage regulating equipment, transformers and lines replacements, and the activation of advanced inverter functionality (e.g., autonomous volt/VAR) in expanding PV hosting capacity. Existing DPV systems are assumed to operate with the legacy unity power factor, and we considered the possibility of retrofitting such systems with the activation of volt/VAR control as integration standards and regulations continue to evolve to allow such functions. The cost-benefit analysis metrics used in study include distribution upgrade costs, average cost per watt of the upgrade cost, average marginal cost per watt of the upgrade cost, and power losses.

14 SOLAR ENERGY↗

U.S. Department of Energy-National Lab Equity Summit: Grid Planning and Operations (Workshop Report)

This report summarizes the U.S. DOE and national laboratories equity summit that was held on February 5, 2024, and focused on grid planning and operations. The objectives of the summit were to connect DOE and lab researchers working on grid-related equity issues, share information on current and planned grid-related equity projects and initiatives, and inspire and educate participants by hearing from our panelists about solutions and challenges to integrating equity in grid planning and operations. The summit included two panels of industry leaders. The first was a state and community perspectives panel that included representatives from a state public utility commission (Oregon Public Utility Commission), a state energy office (Washington Department of Commerce), a state utility consumer advocate (Connecticut Consumer Counsel), and industry consultants (Elevated Engagement and ArkSpring Consulting). Panelists shared successes they have seen, critical challenges related to equity and grid planning and operations, and other considerations. The second panel addressed utility perspectives and included representatives from two utilities (Commonwealth Edison and Tacoma Power), the National Rural Electric Cooperative (NRECA), and a former utility employee and legal consultant. Panelists discussed the role of the utility concerning equity, the most significant technical and data modeling needs and opportunities, and the role the labs could help advance equity in grid planning and operations. There was also a session on partner organization presentations. Argonne National Laboratory made a short presentation on the Grid Modernization Laboratory Consortium (GMLC) project they are leading on equity-informed power system planning. NARUC, NASEO, and the Clean Energy States Alliance, as partners of the GMLC project also shared updates on relevant activities and resources. During the summit, there were two rounds of lightning presentations by national labs and DOE highlighting research that addresses equity and grid planning and operations (Tables 5 and 6 and slides in the Appendix). The goal of the lightning rounds was to share information between participants to encourage collaboration and leverage ongoing research at labs and DOE. The summit included two interactive exercises where summit participants shared their perspectives on relevant equity projects and initiatives (Table 2), key challenges regarding equity and grid planning and operations (Table 3), and promising innovations or progress (Table 4). At the end of the session, participants were asked to share essential insights from the event (Table 7) and an action they plan to take as a result of the event. Participants agreed that the event was useful in helping them share and learn from each other. The project team plans to use the information from the summit as a starting point to help inform future research and technical assistance. In 2026, another Equity Summit will be held (virtually or in person) as part of the same project to help raise awareness and disseminate research and resources completed during the project's duration.

24 POWER TRANSMISSION AND DISTRIBUTION↗