Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electric grid systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Community-Based Transactive Coordination Mechanism for Enabling Grid Edge Systems

The changing landscape of the electricity industry, characterized by a surge in distributed energy resources (DERs) and proactive customers, necessitates practical solutions for coordinated operations especially at the distribution-level. This paper introduces a community-based transactive coordination mechanism designed to incentivize customers for providing localized and system-level services reflected through real-time prices. The work presents a bidding approach for communities with DERs, such as solar photovoltaic (PV) and battery energy storage systems (BESS), to formulate their price-responsiveness for retail energy coordination, emphasizing a community-centric model. By sending bidding curves to a third-party, the mechanism enables customers with DER assets to actively participate in localized coordination with the load serving entity (LSE), thereby supplementing each other’s and even the utilities needs through a shared energy economy. The proposed transactive mechanism is implemented leveraging a co-simulation framework that integrates a distribution grid simulator and Python-based agents for performance evaluation. Collaboration with a local utility to access real distribution feeder models and consumption profiles yields simulation results demonstrating the potential to reduce costs by 12\% for communities with DERs like PV and BESS.

Community-based coordination, grid-edge systems, R↗

A python package for analyzing Resilience of Complex Systems (pyRoCS) v.0.0

SAND2024-01040O PyRoCS software synthesizes mathematical equations from several domains—including information theory, ecology, and engineering sciences—to support resilience analysis for complex systems. Resilience is the ability of the complex system being analyzed to withstand, operate through, and recover from a disruption. The complex system can be a physical system such as an electric grid, an organization such as a company, or even a subfunction of an organization. Existing mathematical equations for resilience analysis are found within multiple domains including information theory, biological sciences, and complex systems. This package synthesizes and refactors equations from these various domains to make them more generalizable for application across different types of complex systems relevant for resilience analysis. Users will be able to apply these equations to characterize different components of complex systems based on available data. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Verzi, Stephen↗

Flexible Charging to Unify the Grid and Transportation Sectors for EVs at Scale (FUSE)

Electric vehicle (EV) adoption will expand beyond light-duty vehicles charging at lower-power public locations and family residences to include medium- and heavy-duty applications with more powerful charging at public stations and private depots. The Vehicle Grid Integration (VGI) and Smart Charge Management (SCM) pillar in EVs@Scale supports multiple projects. The FUSE project is developing and evaluating enabling technologies, charging solutions, and infrastructure design approaches to investigate the intricacies and potential benefits of vehicle grid integration and the application of smart charge management to charging of electric vehicles at scale. This presentation summarizes the findings of this research in 2024.

ADVANCED PROPULSION SYSTEMS↗

Distributed Energy Resource (DER) Reliability for Backup Electric Power Systems

Hospitals, emergency services, military bases, ports, airports, industries, commercial facilities, and others rely on backup power systems to provide electricity for their critical loads during grid outages. The purpose of this report it to provide accurate reliability information on commonly deployed distributed energy resources (DERs) to improve quantitative estimates for the reliability of these backup power systems during a grid outage. A backup power system consists of DERs, an electric distribution system with its associated switches and other devices, and mechanisms to control and manage the flow of electricity. Too often, facilities and campuses fail to properly quantify the reliability of their backup power systems. DERs are assumed to be 100% reliable, with the only concern being the availability of fuel. Such assumptions can lead to gross errors in the backup system's reliability estimates, particularly for long-duration outages. This report provides a set of estimates for reliability of emergency diesel generators (EDGs), natural gas prime generators and combined heat and power (CHP) prime movers, solar photovoltaics (PV), wind turbines, and Li-ion battery energy storage systems (BESS). The estimates are derived from empirical data when available and supplemented by modeling results when needed. These reliability estimates are for the DERs ability to provide power during a grid outage, ranging from an hour to 2 weeks.

14 SOLAR ENERGY↗

Investigation of Nonflammable Electrolytes for Behind-the-Meter Storage Batteries

Behind-the-Meter Storage (BTMS) is a battery-based, stationary energy storage system that is connected to the residential or industrial customer's side of the electrical grid utility service meter. BTMS systems enable consumers to (A) economically schedule charging and usage of stored energy, (B) store and use energy from on-site generation, especially from inconstant, renewable sources like solar and wind, and (C) avoid overloading the grid during peak hours via supplementation with stored energy. BTMS battery performance requirements and general priorities differentiate from other applications, like EVs, which has prompted the development of batteries with tailored electrode and electrolyte materials. These materials prioritize low cost, avoiding critical materials; longevity, achieving 8000 cycle and 20-year shelf lives; and importantly, high safety. Nonflammable electrolytes show promise to improve safety by mitigating thermal runaway, yet often come with sacrifices to battery performance. In this presentation (1) primary categories of nonflammable electrolytes will be discussed; (2) a rational design of experiment will be presented for efficient performance evaluation of several nonflammables electrolyte in BTMS-relevant battery chemistry, Li4Ti5O12- and LiNi0.90Mn0.10O2; and (3) preliminary results will be presented.

battery↗

Assessment of peak power demand reduction available via modulation of building ventilation systems.

Peak power demand strains electrical grids and increases cost of electricity generation, transmission and distribution infrastructure. Many studies have examined ways of reducing peak power demand, including modification of room air temperature setpoints or reduction of lighting levels. However, very few or no studies have examined the peak power reduction resource offered by temporary curtailment of building ventilation systems. For this reason, we conducted a simulation campaign in which we examined the resource offered by temporary ventilation curtailment in commercial buildings of different use types across the United States and in residences in the state of California, with the essential constraint that any changes resulted in air quality acceptable to occupants through additional ventilation to compensate for the curtailment. To do this, we employed previously validated building models implemented in the airflow and contaminant transport tool CONTAM and building thermal and systems modeling tool EnergyPlus, in some cases co-simulated. Overall, results show savings are highly dependent on building type and climate but range from 0–2 W/ft 2 and up to 40% of total peak building power demand. Depending on building type, this power shed can be conducted for 1.5–8 h before acute exposure or odor concerns are expected, assuming a safety factor of 2. This reduction is of the same magnitude as that offered by thermal control strategies such as setpoint increase, or from lighting reduction strategies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A 20-kW DC Oak Ridge Converter with Integrated AC & DC Sources for Grid Services and Energy Storage Systems

This paper proposes a wireless power transfer (WPT) platform with integrated energy conversion that has the capability for 1) recharging the energy storage systems (ESSs) from the grid systems, including renewable energy sources such as wind, solar, etc., 2) off grid systems recharging the ESSs from dc grid systems, 3) grid recharging of electric vehicles (EVs), and 4) off grid recharging of EVs from ESSs. The unique aspect of the method is the use of multi-interface power electronic converter for the grid and ESSs and EVs that can support a range of applications with ac / dc and dc / dc energy conversion ability in a single converter system. The key enabling technology to achieve these functionalities is Oak Ridge Converter (ORC) with polyphase coupler coil system both developed at ORNL. This new technology enables higher power density WPT systems while allowing the coils to interface from ac grid at 60 Hz frequency or dc source directly merging with 85 kHz operating frequency of switching component. The experimental results of the proposed system are presented for 20 kW output power with the system overall efficiency around 95.4% from dc source and 93% overall efficiency from ac grid achieving 9-10% current total harmonic distortion (THD) and 0.98-0.99 power factor (PF).

Asa, Erdem↗

An Overview of Issues Related to IEEE Std 1547-2018 Requirements Regarding Voltage and Reactive Power Control

The revised Institute of Electrical and Electronics Engineers (IEEE) 1547 Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces (IEEE Std 1547-2018) was published in April 2018. This standard is one of the foundational documents in the United States needed for integrating distributed energy resources (DERs), including solar energy systems, with the electric distribution grid. The revised standard contains 11 chapters (clauses) and 8 annexes that comprise 136 pages. The revision is significantly different from the 2003 version, and it contains new concepts and new technical requirements. Each clause specifies information or requirements that apply to certain aspects important to the interconnection of DERs to the electric power system. Implementing the requirements necessitates a careful study of the underlying technical concept and requires the appropriate information required to calculate relevant settings and configurations. Various stakeholders have different roles in implementing the standard, and portions of the standard are directed toward a specific audience who must possess specialized information and technical training to use and apply the requirements. This document aims to (1) summarize a specific portion of the standard as concisely as possible and (2) provide the reader with introductory knowledge and information to support the utilization of the requirements.

14 SOLAR ENERGY↗

Community-scale interaction of energy efficiency and demand flexibility in residential buildings

Demand-side management (DSM) strategies, including energy efficiency (EE) and demand flexibility (DF), contribute to cost-effective operation of the electricity grid. From a system-level perspective, such programs reduce costs, enhance reliability, and reduce network issues. Similarly, DSM programs help participating customers reduce utility bills while maintaining occupant comfort. Understanding the relationship between EE and DF is key to realizing the full potential of DSM programs. In this study, we modeled an all-electric residential community based on a 498-home community that is planned for construction in Fort Collins, Colorado in the United States. We used this community model to study the relationship between different EE measures, including building envelope upgrades and smart appliances, and DF enabled by a home energy management system (HEMS) responding to a time-varying tariff. Various EE levels in the homes – code-minimum, zero energy ready, and even higher levels of envelope efficiency – were simulated. DF is enabled by the HEMS, which coordinates behind-the-meter resources, including flexible building loads, PV, and home battery systems, to minimize utility bills while maintaining occupant comfort. When comparing to the code-minimum homes, EE upgrades alone reduce HVAC energy use during peak hours by up to 50% and the HVAC utility bill by up to $312/year. With the addition of HEMS, the average daily peak demand can be reduced by up to 0.58 MW or 1.2 kW/home in the higher envelope efficiency homes. The combination of EE upgrades, HEMS, and home battery systems is expected to save homeowners up to $590/year while increasing community load flexibility. However, HEMS and home battery systems are less effective in increasing the DF in the more efficient homes due to the lower load.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Background Information on the Power Quality Requirements in IEEE Std 1547-2018

The revised Institute of Electrical and Electronics Engineers (IEEE) 1547-2018, Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces, was published in April 2018. This standard is one of the foundational documents in the United States needed for integrating distributed energy resources (DERs), including solar energy systems, and energy storage systems with the electric distribution grid. The revised standard contains 11 chapters (clauses) and 8 annexes that comprise 136 pages. The revision is significantly different from the 2003 version, and it contains new concepts and new technical requirements. Each clause specifies information or requirements that apply to certain aspects that are important to the interconnection of DERs to the electric power system. Implementing the requirements necessitates a careful study of the underlying technical concepts and requires appropriate information to calculate relevant settings and configurations. This document provides informative material on the requirements related to electrical power quality in IEEE Std 1547-2018, with the intent to equip the reader with basic knowledge and background information to improve understanding and use of the requirements specified.

14 SOLAR ENERGY↗

Grid-Integrated Electric Mobility Model (GEM) v1.0

Transportation is the fastest-growing source of greenhouse gas (GHG) emissions and energy consumption globally. The convergence of shared mobility, vehicle automation, and electrification has the potential to drastically reduce transportation impacts, but requires careful integration with rapidly evolving electricity systems. We have developed the GEM Model (Grid-Integrated Electric Mobility) to examine these interactions with a U.S.-wide simulation framework encompassing private electric vehicles (EVs); shared automated EVs (SAEVs); charging infrastructure; controlled EV charging; and a grid economic dispatch model to simulate mobility futures exclusively using EVs. We find that an SAEV fleet 9% the size of today's active vehicles can satisfy trip demand with only 2.6 million chargers (0.2 per EV). Controlled EV charging can also reduce electricity demand variability, significantly reducing GHG emissions and decreasing solar curtailment by about one-third. While private EVs with uncontrolled charging would reduce GHG emissions by 53% compared to gasoline vehicles, SAEVs could achieve a 70% reduction.

Sheppard, Colin↗

High Speed Medium Voltage CHP System with Advanced Grid Support

The project was a collaboration between Clemson University and TECO Westinghouse Motor Company. The goal of the project was to develop a medium voltage commercial grid-tied system with advanced grid support functions. Current state-of-the-art in medium voltage, multi-megawatt power electronic systems do not support advanced grid functions, traditionally due to power electronic limitations and required applications. The developed system is capable of interacting with the power system at the distribution level to efficiently integrate gas turbine generation systems or any other ac generation system with up to 20MWe of power production capacity. This project demonstrated a high level of technical readiness of the 1MW, 500Hz, 15000 RPM high frequency Combined Heat and Power (CHP) generator and electric machine system, utilizing advanced grid support functions required by IEEE Std. 1547-2018.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The value of integrating a geothermal district heating system into a microgrid

As electrical grids increasingly rely on variable renewable energy, maintaining reliability and cost efficiency becomes more complex. To address these challenges, this study analyzed the integration of geothermal district heating as a grid-responsive thermal resource within a microgrid in Tuttle, Oklahoma. Building energy modeling using EnergyPlus estimated annual district heating demand at 2.9 GWh, with a peak load of 2.8 MW th . Techno-economic analyses were conducted to meet the heating demand under three geothermal scenarios, varying by production depth, flow rate, and thermal output, each supplemented by natural gas peaking boilers. In parallel, equivalent electrical load profiles were developed using typical coefficients of performance (COPs) for air-source heat pumps and electric boilers to establish an electrified baseline scenario. A complete end-use electrical load profile was also developed for the microgrid using Cambium dataset. The modeling results demonstrated reliable and economic operation of the geothermal systems over 30 years, with COPs ranging from 2.6 to 8.9 and the lowest levelized heating cost at $\$$54.6/MWh. Geothermal integration reduced electricity consumption by up to 94.7 % compared to the non-geothermal base case, yielding annual energy savings of up to $\$$803 k. Avoided grid costs ranged from $\$$65 k–$\$$147 k per year, with individual events avoiding up to $\$$4,863 per hour. Grid-responsive operation further reduced wholesale energy costs by 53–56 %. These findings demonstrate geothermal heating, traditionally treated as a non-grid-responsive thermal resource, can be reconfigured to support dynamic grid services, offering a scalable pathway to enhance reliability and reduce costs in renewable-rich microgrids and district heating networks.

15 GEOTHERMAL ENERGY↗

Probabilistic Grid Reliability Analysis with Energy Storage Systems

SAND2025-12025O The Probabilistic Grid Reliability Analysis with Energy Storage Systems (ProGRESS) software tool is an open-source tool for assessing the resource adequacy of the evolving electric power grid integrated with energy storage systems (ESS). This tool uses a simulation engine to create diverse scenarios that test the limits of the modern power grid consisting of a high-volume ESS and variable energy resources (VER). Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Nguyen, Tu↗

Impacts of Regional Coordination on Transmission Needs for Power System Resource Adequacy [Slides]

Resource adequacy (RA) is an important component of bulk power system reliability that addresses whether there are sufficient resources available to meet electricity demand at all times. RA analysis is used to assess whether the planned power system will provide reliable electricity to consumers while accounting for equipment outages, weather variability, and load uncertainty. Coordination between regions can enable resource sharing to meet RA needs if sufficient transmission capacity exists. Transmission's role in RA coordination can be particularly pronounced for large power systems like the U.S. electricity grid which contains geographically diverse demand and weather-dependent resources. Depending on the level of coordination desired, existing inter-regional transmission capacity may not be sufficient. This study is designed to assess optimal pathways for the development of inter-regional transmission in the U.S. under varying levels of RA coordination. Results can inform long-term grid infrastructure planning and provide insights into potential benefits of greater coordination for generation and transmission planning between regional U.S. power systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Modeling the Potential Impact of Storage on the US Power Sector in a Multisector Dynamic Context

The electric power sector is expected to grow in size, importance, and complexity around the world as economies expand and electric supply technologies and demand patterns evolve in significant ways. At the same time the electric power sector may see substantial increases in VRE generating technologies which can add variability and uncertainty to the diurnal and seasonal profile of electric supply. With these forces in play, the emergence of modular, flexible electricity storage technologies may have profound impacts on the operation of electric power systems. Here we reduce a storage modeling gap in MSD models by incorporating grid-based electricity storage into the electric sector dynamics of the Global Change Analysis Model-USA (GCAM-USA) with improved power sector representation. We find a potentially significant role for storage technologies in the future of the U.S. power system, with storage capacity ranging from 7.7 to 14.7 GW in 2050 and 13.9 to 31.6 GW in 2100 across several techno-economic scenarios. We also find that storage can help to smooth variability in residual load arising from evolving electricity demands and the introduction of high shares of VRE to the electric grid. This reduces reliance on high-cost peaking generators, improves system-wide capacity factors, and limits curtailment of VRE.

Patel, Pralit L.↗

Higher Efficiency, Demand Flexible Refrigerator with On-Demand Micro-Vibrational De-icing Technology

Refrigerator technology has advanced significantly over the last couple of decades. Today’s refrigerators use only about 25% of the energy that was required to power models built in 1975. Even as they continually improve efficiency to meet standards, refrigerators have increased in size by almost 20%, added energy-consuming features such as through-the-door ice, and provide more benefits than ever before. However, a few challenges and technology gaps are preventing further improvement of the demand responsiveness and efficiency of the refrigerators. One of the major technology gaps in existing refrigerators is their outdated de-icing process. When the evaporator generates frost, an old-fashioned resistive heating element melts the ice. Most refrigerators have a timed defrost cycle, rather than an active system that could monitor the state of the frost. In these systems, not only is the precious electricity used at its least efficient form of conversion (direct conversion of electricity to heat), but also all the latent heat associated with the ice is wasted during the melting process. On top of that, the refrigerator needs to work harder to pull the temperature down after defrosting, and, last but not least, the food quality is severely impacted by the temperature swings during the defrost cycle. According to a study, the EU alone wastes 89 million tons of food in the supply chain every year. Any temperature swing during defrosting (about 6F according to Emerson for low-temperature cases) can negatively impact the shelf life of meat and other products for multiple days. All these issues can happen during the peak demand time of the electric grid. Unlike the conventional systems, the proposed novel advanced micro-vibrational deicing process uses no heat for defrosting. Instead, it uses the micro vibrations generated by a piezoelectric or vibration-generating module to mechanically break ice from the heat exchanger almost instantaneously. The project titled “Higher Efficiency, Demand Flexible Refrigerator with On-Demand Micro-Vibrational De-icing Technology, performed by Ultrasonic Technology Solutions, LLC (UTS) of Knoxville, TN, in collaboration with Emerson (now Copeland), represents the final phase of a multi-year effort funded under the U.S. Department of Energy’s Building Technologies Office (BTO) BENEFIT FOA 2020. Initiated on October 1, 2021, and completed after a nine-month no-cost extension ending September 30, 2025, this project aimed to develop and validate a novel micro-vibrational mechanical defrosting system, achieving more than 25% improvement in defrosting energy efficiency over conventional baseline defrosting technologies. Over sixteen quarters, the project advanced from fundamental ice-mechanical characterization and prototype development to full-scale system integration and validation. Initial efforts established project management infrastructure and characterized ice adhesion properties, followed by the design and fabrication of early aluminum-based prototypes for resonance frequency testing. Subsequent quarters saw rapid technical progression, including the identification of optimal piezoelectric and motor-based vibration mechanisms, the demonstration of effective de-icing over 6x6-inch aluminum surfaces. The team achieved its Go/No-Go milestone by exceeding the 25% energy-efficiency improvement target—reaching up to 3,340% under optimized conditions—and later confirmed that motor-driven systems offered superior performance and energy efficiency compared to piezoelectric alternatives. Continued refinement led to the development of amplifier systems on printed circuit boards, improved control and instrumentation hardware, and integration into full-scale heat exchanger (HX) prototypes at both UTS and Copeland facilities. Multiple vibration-mounting studies and frost-growth experiments guided mechanical optimization and noise-mitigation strategies, achieving a 17.5 dB reduction in sound pressure level and verifying robust mechanical performance. Advanced analyses, including modal and harmonic simulations, established a quantitative understanding of vibrational behavior and de-icing efficiency across >1000 cm² systems. The final project phase successfully demonstrated scalable integration within reach-in and chest freezer prototypes, confirmed >25% efficiency improvements in large-area systems, and completed a comprehensive business model and scale-up strategy identifying electric defrost systems as the primary beachhead market. The culmination of this DOE-supported effort establishes micro-vibrational defrosting as a viable, high-efficiency, low-noise, and demand-flexible de-icing technology, paving the way for commercial deployment and broader application in next-generation refrigeration systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗