Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “drum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Nanowire and micro wire fabrication technique and product

A continuous or semi-continuous process for fabricating nanowires or microwires makes use of the substantially planar template that may be moved through electrochemical solution to grow nanowires or microwires on exposed conductive edges on the surface of that template. The planar template allows fabrication of the template using standard equipment and techniques. Adhesive transfer may be used to remove the wires from the template and in one embodiment to draw a continuous wire from the template to be wound around the drum.

Sumant, Anirudha V.↗

Thermodynamic Analysis of Thermo-vacuum Clothes Drying Operation

Clothes drying accounts for a significant amount of energy consumed in residential and commercial sectors. A thermal vacuum clothes drying technology (TVCD) is proposed as an advanced clothes dryer which can significantly reduce the energy requirements by expediting the drying process. In the conventional convective clothes dryer, hot dry air is introduced into the drum which gets in direct contact to dry the clothes. This process is energy inefficient since the significant amount of heat and the water carried out with the exhaust stream are wasted. In contrast to the conventional convective drying technique, the drying mechanism of TVCD is through nucleate boiling at low temperature due to reduced vessel pressure. The process is not only efficient but also reduces the required time for drying. The objective of this paper is to develop a comprehensive thermodynamic model to predict the transient drying process of TVCD. The three-stage system model including the detail analysis of individual components is capable of simulating the variation of the water content in the textile under various operational conditions. The preliminary results show that the drying time of 3 lb textile from 70% to 2.5% in TVCD is approximately four times less than the time required in the conventional clothes dryer. Parametric studies are carried out to understand the effect of operation conditions and component geometry on the system performance. Energy consumption of the system is also analyzed.

Yang, Cheng-Min↗

Hybrid Temperature-Reactivity PID Controllers for Nuclear Thermal Propulsion Startup

In this work, a novel temperature-reactivity controller is introduced to rotate control drums based on a chamber temperature signal. It consists of two components: (1) a reactivity-driven proportional controller converting the temperature demand into a reactivity signal, and (2) a temperature-driven proportional-derivative controller which relies on a derivative term to anticipate sudden changes in demand and limit temperature overshoot. A weighting function is proposed to continuously transition from one component to the other.

33 ADVANCED PROPULSION SYSTEMS↗

Hybrid Temperature-Reactivity PID Controllers for Nuclear Thermal Propulsion Startup

In this work, a novel temperature-reactivity controller is introduced to rotate control drums based on a chamber temperature signal. It consists of two components: (1) a reactivity-driven proportional controller converting the temperature demand into a reactivity signal, and (2) a temperature-driven proportional-derivative controller which relies on a derivative term to anticipate sudden changes in demand and limit temperature overshoot. A weighting function is proposed to continuously transition from one component to the other.

33 ADVANCED PROPULSION SYSTEMS↗

Low Level Radon Concentration and Radon Daughter Dose Monitoring in an Arid-zone Waste Store - 20081

Radioactive waste containing predominantly soil and rubble from the clean-up of a former uranium and thorium minerals processing research facility is currently stored at the Woomera Test Range in South Australia awaiting final disposal. Prior to commencing any manipulation of the nearly 10,000 waste drums (205 L or 55 gallon each), radon concentration monitoring and radon daughter dosimetry has been undertaken to (i) gain understanding of the temporal and spatial variation of radon and its daughters within the storage facility, which could provide insights into the radiological source term and (ii) confirm that radiological risks to workers are below the guideline values. A time series of nearly 12 months of detailed observations shows low level radon concentrations with annual average values that are slightly above the average radon concentrations in Australian homes. Peak values in summer are about three times higher than the annual average based on the CRM measurements. Both radon concentrations and annual effective dose are well below the regulatory limits. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

OPTIMUS{sup TM} Packaging for Intermediate Level Wastes and Spent Fuel - 20129

NAC's OPTIMUS{sup TM} packaging is a family of Type B(U)F transportation packages designed for maximum flexibility and cost-efficiency to support shipment of a wide range of challenging wastes and materials. They are small, modular packaging designs meeting DOT weight limits for road transport. OPTIMUS{sup TM} contents include low level waste, mixed low-level waste, irradiated fuel waste and intermediate level waste. Contents can also include aerosol cans with compressed gas and liquefied gas propellants and standard DOT 3E lecture bottles for shipment to treatment facilities. OPTIMUS{sup TM} packaging provides a cost-effective solution for challenging and unique waste contents combined with design simplicity and operational flexibility meeting the requirements of both SSR-6 and 10 CFR 71 for Type B(U)F packaging. The modular design of the packaging components combined with the flexibility to add modified internals for enhanced packaging performance makes OPTIMUS{sup TM} the preferred solution for many radioactive material transportation needs. The OPTIMUS{sup TM} product line currently includes two packaging designs; OPTIMUS{sup TM}-L and OPTIMUS{sup TM}-H. OPTIMUS{sup TM}-L is a lightweight transportation packaging intended for low-activity wastes, whereas OPTIMUS{sup TM}-H is a larger, heavier package intended for high-activities wastes. Due to its small size and weight, six (6) to ten (10) OPTIMUS{sup TM}-L packages can be accommodated on a single legal-weight truck shipment, depending on the weight of the contents. For typical payloads, two (2) OPTIMUS{sup TM}-H packages can be accommodated on a single legal-weight truck shipment. The OPTIMUS{sup TM} packaging share the same cask containment vessel (CCV) in the OPTIMUS{sup TM}-H and OPTIMUS{sup TM}-L. The large cavity size of the CCV, which can accommodate a 416-liter (110-gallon) drum, combined with the small size, low weight and modularity of the OPTIMUS{sup TM} packaging provides unmatched flexibility. In this paper, NAC provides a technical overview of the OPTIMUS{sup TM} packaging and identifies the design features and technology advancements making the OPTIMUS{sup TM} a readily adaptable and flexible solution for packaging processing facilities, reactor and decommissioning wastes. Optimized shielding performance through the addition of internal shielding components and alternative shipping configurations are discussed. In addition, an overview of the first major deployment of the OPTIMUS{sup TM} packaging for the Whiteshell Laboratories Closure Project (WLCP) is discussed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Non-destructive Material Characterization of Radioactive Waste Packages with QUANTOM{sup R} - 20130

During the last decades, the nuclear and non-nuclear industry has produced a considerable amount of low and intermediate level radioactive wastes. In many countries, it is foreseen to dispose of these waste packages safely in a final repository under strict waste acceptance requirements (e.g. the radiological and material characterization) defined by national licensing and supervisory authorities. The material characterization of waste packages can be performed on the basis of existing documentation or, if the documentation is insufficient, on further destructive or non-destructive analysis. Non-destructive methods are to be preferred to minimize radiation exposures of operating personnel as well as costs. We offer here an innovative non-destructive technology called QUANTOM{sup R} (Quantitative Analysis of Toxic and nontoxic Materials) based on prompt and delayed gamma neutron activation analysis (P and DGNAA). This technology is able to identify, quantify and thus verify the amount of hazardous and non-hazardous substances in 200-l radioactive drums, which is required for a final disposal characterization. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improving PCM Waste Management Through New Approaches to Screening for LLW Treatment and Disposal - 20145

A major step forward in the management of Plutonium Contaminated Material (PCM) Waste has been taken at the Sellafield site with the introduction of new capabilities to enable wastes previously conservatively designated as PCM Intermediate Level Waste (ILW) to be re-classified for treatment as Low Level Waste (LLW). The Sellafield site, located in the North West of England, within the United Kingdom (UK), has operated plutonium processing plants and waste facilities for almost 70 years. During this time management of the raw PCM waste produced has presented a variety of challenges. The waste is currently processed by high force waste compaction in the Waste Treatment Complex (WTC). The WTC converts 200 litre drums of raw PCM waste into a compacted, grout encapsulated monolith form within stainless steel containment, ready for emplacement within the UK's Geological Disposal Facility (GDF) when it becomes available. To help progress some of the wastes waiting for treatment, recent improvements have been made with the introduction of new waste assay instrumentation which enables the identification of a 'candidate' waste potentially suitable for disposal via the LLW treatment route. Opening a new LLW route for previously designated PCM has been a major advance in PCM waste management policy. It has required a range of technical assessment arrangements to be developed, tested and commissioned and involved the engagement of a wide range of stakeholders. In particular, very detailed technical analysis methods have been developed to ensure that there is a robust and conservative approach to the final sentencing of waste. Following completion of commissioning tests, the first 86 m{sup 3} of previously designated PCM waste was successfully treated through the LLW route and consigned to LLW disposal in June 2019. The direct benefit of sentencing waste to the correct waste route (LLW) is the significant cost savings across the complete range of waste management activities. This work is also strategically important for demonstrating to a range of stakeholders including workforce and regulators, that waste previously designated as PCM can be re-classified in a systematic and justifiable way without increasing risk to personnel or the wider environment. By ensuring that waste is being managed appropriately it will be possible to carry out more remediation work safely, in less time, and at a lower cost. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improvement of Quantification in Non-Destructive Characterization of Radioactive Waste Packages -Introduction to the Ideas of a Currently Started Project - 20197

For the characterization of radioactive waste packages (e.g. 200-L drums) with inhomogeneous activity and density distributions preferably non-destructive methods like segmented gamma scanning and transmission measurements are applied. While the first is used for identification of the radioactive inventory, both are necessary for a reliable activity quantification. Although at nuclear facilities, segmented gamma scanner are state-of-the-art and are mostly equipped with a vertically moveable transmission source the combining of this data and further a-priori information improving accuracy in data estimation giving realistic, reliable and traceable uncertainty estimations are improvable. This challenge is tackled by a R and D project funded by the German Federal Ministry of Education and Research (BMBF). The boundary conditions for this project are (i) taking into account the typical instrumentation available at nuclear facilities, (ii) minimize the overall measurement time and (iii) combining data from emission and transmission measurements by Bayesian methods. For the R and D project, being still in its initial stage, the basic ideas, the data used for evaluation and the result of a preliminary investigation demonstrating the proof of principle are presented. Additionally, some first aspects on spatial resolution in emission and transmission measurements are addressed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Feedback on Forty-year Long Clean-up Operations of a Contaminated Soil for Environmental Purpose - 20026

One of the CEA facilities in France is the place of miscellaneous mapping and clean-up operations since the 1980's. The final purpose of the conducted work deals with the environmental remediation of the building. In France, the absence of a regulatory framework for the management of sites polluted by radioactive substances, especially as the lack of release thresholds, has led to develop different approaches of soil radiological characterization. The geostatistical approach is part of them. Preliminary investigations are an unavoidable step prior to clearance and remediation. First, historical analysis enables to define site perimeters to investigate as well as to precisely locate expected contaminated parts. For radioactive pollutants, the media (water, soil, air) and transfer routes participate in the definition of the investigation perimeter and thus also need to be identified through a geological study. At the same time, functional analysis leads to choose the best measurement means which could provide useful information when combined with visual inspection. An equipment well adapted to easy-to-measure radionuclides as gamma emitters, such as gamma probe or on-site gamma spectrometry, is usually selected as a non-destructive assay. Coupled with spatial positions, processed on-site radiological data can be mapped. Data processing consists in mapping and kriging before a geostatistical analysis in order to identify the zones of interest to be targeted. Selected zones are not only linked to high level count rates but also to low level ones so that a pollution-free reference is known in the area. This data processing also enables to categorize waste types according to their origin and contamination levels. An expected volume of different waste then follows as well as the waste characterization equipments. In-depth investigations, e.g. core drillings and samplings, naturally ensue to aim at remediation optimization through the assessment of environmental impact. After clean-up operations, non-destructive assays as well as destructive samplings enable to check the effective clearance. Following this methodology in the present remediation work, results of the first non-destructive assay campaign highlighted a long-lived transuranic radionuclides contamination in the concrete flagstone. Successive non-destructive assays were then performed in the defined zones of interest. Count rates measured with a surface probe were first mapped. The best localization of destructive assays, i.e. core drillings at a 1 meter depth, came from this surface mapping followed by a geostatistical analysis. The concrete flagstone was totally removed. Then, the depth of soil to remove under the flagstone was optimized from the results of radiological activities measured in core drillings samples. A new surface mapping was then drawn after this partial soil excavation. The sand and demolition rubble samples, homogeneously constituted from the flagstone fragments, were analyzed by gamma spectrometry. Meanwhile, waste drums and other containers were also measured by gamma spectrometry and passive neutron measurement devices. All these results have brought miscellaneous pieces of information. In this context, major issues appear in terms of physical constraints such as the premises tininess as well as of soil sampling techniques and in terms of measurement performances assessment and the representativeness of homogeneous samples. The choice of radiological soil and waste characterization devices is described in the light of enhanced performances by keeping in mind radiation protection requirements and a willing to always optimize waste categories (very low level waste) and volume. The improvement of the characterization methods appears through this forty-year long work while sharing the feedback of encountered difficulties. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Declaration of the Chemical Composition of Waste-products for the German Repository Konrad Using Substance Vectors - 20500

The waste acceptance criteria of the German repository Konrad require beside a radiological declaration a compositional declaration to be able to avoid negative impact on the groundwater by a presumed leakage into the groundwater after complete corrosion of the containers in the future. The declaration of the composition has to specify compounds and substances not element analyses, because the chemical behavior and toxicity especially of organic compounds varies strongly The relevant compounds have to be described and quantified using defined substance codes provided by the operator. For simple waste types like pure concrete or steel components, the definition of the composition is rather simple. The composition of more complex waste streams is generally declared using producer specific material vectors, which can be derived for defined waste types (e.g. grouted fluids, ash from combustion, super-compacted mixed waste etc.). Additional substance vectors exist for containers, drums and grout, which together with the waste composition yield the total composition of the waste packages. The substance vectors for homogeneous waste streams like cementitious demolition waste, solidified fluids and ash are mostly based on analyses provided by the waste owner. In some cases, analyses from non-radioactive analogues or data sheets can also be used to demonstrate the composition. For each qualified treatment of radioactive waste streams the material composition is described and balanced on the basis of specific material vectors, which are composed of material codes from the material and cask list provided by the Federal company for radioactive waste disposal. For mixed waste streams like super-compacted or grouted mixed waste or materials simply packed in containers an analyses cannot be used. In these cases, the compositional information from the bookkeeping can be used for the entire waste stream to calculate a mean composition including a compositional range (min / max composition). Only waste packages with an approved material description can be delivered to Konrad. Therefore, the material declaration of all waste streams and the resulting waste products is crucial for all waste owners in Germany to be able to have enough waste packages ready, when the repository is going to open in 2027. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MOOSE framework enhancements for meshing reactor geometries

MOOSE is an open-source, parallel finite element framework designed to permit rapid development of robust multi-physics modeling capabilities. Under the DOE-NEAMS program, numerous solvers have been developed utilizing the open-source MOOSE framework for multiphysics reactor analysis. These solvers require input finite element meshes representing the discretized geometry. Typically, reactor analysts turn to licensed external tools for creation of reactor geometry meshes. Recently, enhancements have been added to the MOOSE framework to mesh common reactor geometries and improve MOOSE-based application user workflows. Support for hexagonal pins, assemblies, and cores has been added, and Cartesian support has been extended. Options for modeling static and rotating control drums within a hexagonal assembly are now available. Pin, assembly, and plane regions can be identified through automatically applied tags on the mesh called 'reporting IDs' for easier post- processing of physics results. An external open-source triangle routine has been leveraged within MOOSE to mesh core periphery zones. A set of reactor geometry builder routines further streamline the construction of hexagonal and Cartesian cores and include the ability to assign materials to regions during mesh generation. The new meshing routines are available through the MOOSE framework in the open-source 'Reactor' module, and the resulting directly within MOOSE-based applications or exported as Exodus II files for use in other finite element solvers. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Application of the ANSI/ANS-8.3-2022 Minimum Accident to Tube Vault Storage

In support of planned site activities, the existing basis for criticality safety in nuclear facilities is being revisited. One such technical basis is the demonstration of Criticality Accident Alarm System (CAAS) coverage in tube vaults at Y-12 National Security Complex. The configuration of the vaults places significant shielding between the source and the detector stations and is dissimilar to drum storage or other processes. This paper describes tube vault storage at Y-12, describes the basis for the application of the 2022 minimum accident for system design (MASD) to the analysis, and presents how the accident is implemented in the analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Uncertainty Quantification and Sensitivity Analysis of Non-Nuclear Advanced Controls Testbed Reactor Mockup

The research presented in this report describes our progress in applying stochastic methods and uncertainty quantification, parametric study, and variance-based sensitivity analysis (also known as Sobol sensitivity analysis) to a full-core model of a nuclear thermal propulsion (NTP) system simulated with Griffin, with the goal of developing a reduced order (surrogate) model which can be rapidly sampled while perturbing multiple input parameters. In this NTP system, reactivity and power feedback affect the rotation of control drums, which are controlled by a hybrid proportional, integral and derivative (PID) controller, actuated by the power demand and reactivity feedback from the numerical model. This model uses reactor kinetic feedback (mean generation time and $\beta$ from a transient Griffin simulation executed with the improved quasi-static method to provide the kinetic parameters) as inputs to functions which control the CD rotation angle. Using a number of stochastic method approaches, we developed a dual purpose training-surrogate model of the NTP system using polynomial regression. The trained model can be rapidly sampled while simultaneously perturbing various input parameters of the model, such as coefficients on the PID control, or temperature (directly affect the neutron cross section). The surrogate model delivers accurate results orders-of-magnitude faster (minutes, not days) than the base model. Once the base model has been trained, distributions of the uncertain parameters can be changed at will to investigate the effects of perturbing multiple inputs and their effect on the output. For example, coefficients used in the PID control system may vary due to some physical interference, or there may be uncertainty in the temperature of the neutron cross sections in various regions of the reactor. A distribution can be placed on these parameters and operational boundaries can be determined. The goal of this work is to support development of an advanced control system to operate CDs in a functioning NTP system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Investigation of the Mechanical Degradation of Zinc-Based Cold Spray Coatings for Steel Pipelines

Internal corrosion in wet natural gas is a big challenge in the oil and gas industry due to corrosive constituents such as carbon dioxide (CO2), hydrogen sulfide (H2S), other forms of sulfur, and water in the gas stream. To mitigate internal corrosion, zinc-based cold spray coatings were designed for use in natural gas pipelines to increase the lifespan of the pipeline network. However, one of the requirements in designing internal coatings is the resistance of the coatings to mechanical forces applied on the pipeline's internal wall during pigging operations. These forces are primarily compressive and shear/friction forces. This study examines material properties that must be considered when evaluating mechanical considerations. To determine the viability of the developed coatings with respect to the shear/friction forces, the shear adhesion and wear resistance of the materials have been evaluated. Shear adhesion testing was performed with modified clevises to determine the shear stress required to cause adhesion failure at the coating/substrate interface. Scanning electron microscopy was utilized to characterize the interfaces after failure. Wear testing was performed on coatings and pipeline materials utilizing pin-on-drum testing. These tests display the stress limitations and wear that the coatings can tolerate from pigging.

mechanical degradation↗

ViBRANT Applied as a Closed Loop Flux and Thermal Surrogate

Surrogate testing platforms provide a means to develop a target aspect of a larger system. Some systems target single aspects while others are more wholistic. ViBRANT (Visual Benign Reactor as Analog for Nuclear Testing) aims to be a wholistic system by representing the primary reactor behaviors through an accessible LED driven reactor core, photodiodes, thermocouples, and high-performance software interfaces being developed to the standards required for actual microreactor deployment such as MARVEL. With the ability to drive control drums enabled with full reactor capability (e.g. speed/angle/torque capability/limits for operation and clutch/spring scram capability), drive ViBRANT’s high fidelity 36 pin hexagon core to represent phenomena via LEDs, and capture the analog response of distributed photodiodes/thermocouples, this paper will show the system’s ability to operate in a closed-loop fashion and do well at matching reactor power/temperature distribution in an accessible reactor surrogate environment.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Comparing Control Performance Between Simulation and Experiment using the Microreactor Automated Control System Testbed

In the advanced reactor domain, a flexible and scalable software/hardware infrastructure is crucial for integrating and validating various control technologies. This study used the Microreactor Automated Control System (MACS) hardware platform as a testbed. MACS was originally designed to mirror Idaho National Laboratory (INL)'s Microreactor Applications Research Validation and Evaluation (MARVEL), a 85-kW thermal fission microreactor. It features control drums for simulated reactivity control; lights that function as a surrogate reactor core, with the brightness being proportional to the reactor power; and light sensors that emulate neutron detectors. To transform MACS into a physical twin of MARVEL for evaluating control methods, the Control and Optimization Modular Modeling Application for Nuclear Deployment (COMMAND) software was employed. This software integrated the hardware with two models of the MARVEL core, based on Reactor Excursion and Leak Analysis Program (RELAP5-3D) and Monte Carlo N-Particle (MCNP) models. The study aimed to demonstrate the gap between control theory and actual practice—a gap that often necessitates empirical adjustments such as control gain retuning, filters, time discretization, and integrator anti-windup measures. Controllers were developed based on increasingly complex simulations without hardware, starting from the base MARVEL model and then introducing actuator saturation constraints and sensor noise. The final control strategy was then tested using MACS, and a comparative performance analysis was conducted.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗