Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dose assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Depth Dose Distribution Study within a Phantom Torso after Irradiation with a Simulated Solar Particle Event at NSRL

The adequate knowledge of the radiation environment and the doses incurred during a space mission is essential for estimating an astronaut's health risk. The space radiation environment is complex and variable, and exposures inside the spacecraft and the astronaut's body are compounded by the interactions of the primary particles with the atoms of the structural materials and with the body itself Astronauts' radiation exposures are measured by means of personal dosimetry, but there remains substantial uncertainty associated with the computational extrapolation of skin dose to organ dose, which can lead to over- or underestimation of the health risk. Comparisons of models to data showed that the astronaut's Effective dose (E) can be predicted to within about a +10% accuracy using space radiation transport models for galactic cosmic rays (GCR) and trapped radiation behind shielding. However for solar particle event (SPE) with steep energy spectra and for extra-vehicular activities on the surface of the moon where only tissue shielding is present, transport models predict that there are large differences in model assumptions in projecting organ doses. Therefore experimental verification of SPE induced organ doses may be crucial for the design of lunar missions. In the research experiment "Depth dose distribution study within a phantom torso" at the NASA Space Radiation Laboratory (NSRL) at BNL, Brookhaven, USA the large 1972 SPE spectrum was simulated using seven different proton energies from 50 up to 450 MeV. A phantom torso constructed of natural bones and realistic distributions of human tissue equivalent materials, which is comparable to the torso of the MATROSHKA phantom currently on the ISS, was equipped with a comprehensive set of thermoluminescence detectors and human cells. The detectors are applied to assess the depth dose distribution and radiation transport codes (e.g. GEANT4) are used to assess the radiation field and interactions of the radiation field with the phantom torso. Lymphocyte cells are strategically embedded at selected locations at the skin and internal organs and are processed after irradiation to assess the effects of shielding on the yield of chromosome damage. The initial focus of the present experiment is to correlate biological results with physical dosimetry measurements in the phantom torso. Further on, the results of the passive dosimetry within the anthropomorphic phantoms represent the best tool to generate reliable data to benchmark computational radiation transport models in a radiation field of interest. The presentation will give first results of the physical dose distribution, the comparison with GEANT4 computer simulations based on a Voxel model of the phantom, and a comparison with the data from the chromosome aberration study.

Berger, Thomas↗

Evaluation of a rapid, generic human gestational dose model

Chemical risk assessment considers potentially susceptible populations including pregnant women and developing fetuses. Humans encounter thousands of chemicals in their environments, few of which have been fully characterized. Toxicokinetic (TK) information is needed to relate chemical exposure to potentially bioactive tissue concentrations. Observational data describing human gestational exposures are unavailable for most chemicals, but physiologically based TK (PBTK) models estimate such exposures. Development of chemical-specific PBTK models requires considerable time and resources. As an alternative, generic PBTK approaches describe a standardized physiology and characterize chemicals with a set of standard physical and TK descriptors – primarily plasma protein binding and hepatic clearance. Here we report and evaluate a generic PBTK model of a human mother and developing fetus. We used a published set of formulas describing the major anatomical and physiological changes that occur during pregnancy to augment the High-Throughput Toxicokinetics (httk) software package. We simulated the ratio of concentrations in maternal and fetal plasma and compared to literature in vivo measurements. We evaluated the model with literature in vivo time-course measurements of maternal plasma concentrations in pregnant and non-pregnant women. Finally, we prioritized chemicals measured in maternal serum based on predicted fetal brain concentrations. This new model can be used for TK simulations of 859 chemicals with existing human-specific in vitro TK data as well as any new chemicals for which such data become available. Furthermore, this gestational model may allow for in vitro to in vivo extrapolation of point of departure doses relevant to reproductive and developmental toxicity.

60 APPLIED LIFE SCIENCES↗

Maps of Primary Radiatoin Dose Around the Lunar South Pole: Preliminary Assessment of Artemis Landing Sites

The Moon has a harsh radiation environment that poses significant challenges to future science and exploration activities. Exposure hazards from space radiation are primarily due to galactic cosmic rays (GCRs) and solar energetic particles (SEPs) that are incident at the lunar surface from all directions. The Lunar Reconnaissance Orbiter’s (LRO) Cosmic Ray Telescope for Effects of Radiation (CRaTER) instrument has been observing space radiation around the Moon since 2009. The CRaTER observations show a steady GCR flux with intermittent SEP events that have much higher fluxes. During solar minimum, the GCR flux is higher, while the SEP events are less common. On the other hand, during solar maximum, the SEP events have are more frequent and the GCR flux is lower. This is due to variations in solar activity. GCRs have characteristic energies spanning from 1 MeV to 10s of GeV. SEPs, however, have much lower energy ranges of 50 keV to 100s of MeV.

P. H Phipps↗

Biota Modeling in EPA’s Preliminary Remediation Goal and Dose Compliance Concentration Calculators for Use in EPA Superfund Risk Assessment: Explanation of Intake Rate Derivation, Transfer Factor Compilation, and Mass Loading Factor Sources

The Preliminary Remediation Goal (PRG) and Dose Compliance Concentration (DCC) calculators are screening level risk assessment tools that set forth the Environmental Protection Agency’s (EPA) recommended approaches and currently available risk assessment guidance for response actions at Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) sites, commonly known as Superfund. The environmental screening levels derived by the PRG and DCC calculators are used to identify isotopes contributing the highest risk and dose as well as establish preliminary remediation goals. Each calculator has residential gardening and subsistence farmer exposure scenarios that model transfer of contaminants from soil and water into various types of biota (crops and animal products). New publications of human intake rates of biota; farm animal intakes of water, soil, and fodder; and soil to plant interactions require updates be implemented into the PRG and DCC calculators. Recent improvements in the biota modeling for these calculators include newly derived biota intake rates, enhanced soil mass loading factors (MLFs), and more comprehensive soil to plant transfer factors (BV’s) and soil to tissue transfer factors (TFs) for animals. New biota have been added in both the produce and animal products categories that greatly improve the accuracy and utility of the PRG and DCC calculators and encompass greater geographic diversity on a national and international scale.

54 ENVIRONMENTAL SCIENCES↗

Calcium kinetics with microgram stable isotope doses and saliva sampling

Studies of calcium kinetics require administration of tracer doses of calcium and subsequent repeated sampling of biological fluids. This study was designed to develop techniques that would allow estimation of calcium kinetics by using small (micrograms) doses of isotopes instead of the more common large (mg) doses to minimize tracer perturbation of the system and reduce cost, and to explore the use of saliva sampling as an alternative to blood sampling. Subjects received an oral dose (133 micrograms) of 43Ca and an i.v. dose (7.7 micrograms) of 46Ca. Isotopic enrichment in blood, urine, saliva and feces was well above thermal ionization mass spectrometry measurement precision up to 170 h after dosing. Fractional calcium absorptions determined from isotopic ratios in blood, urine and saliva were similar. Compartmental modeling revealed that kinetic parameters determined from serum or saliva data were similar, decreasing the necessity for blood samples. It is concluded from these results that calcium kinetics can be assessed with micrograms doses of stable isotopes, thereby reducing tracer costs and with saliva samples, thereby reducing the amount of blood needed.

Clinical Trial↗

E-Area Low-Level Waste Facility GoldSim System Model

This report documents the development of the E-Area Low-Level Waste Facility (ELLWF) trench system model. The GoldSim® Monte Carlo simulation software is utilized to model the release and transport of radiological inventory disposed (both currently and in the future) within Engineered and Slit Trenches. This model is in support of the sensitivity and uncertainty analysis for the ELLWF Performance Assessment. The ELLWF system model utilizes a hybrid-approach to accurately describe the disposal system. The Hydrologic Evaluation of Landfill Performance model provides the infiltration data to both PORFLOW and GoldSim. PORFLOW is used to calibrate the GoldSim model to ensure confidence in the stochastic results. Finally, the concentrations from GoldSim transport simulations are fed into the SRNL Dose Toolkit to calculate dose impacts and assess plume interaction

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Transient Copper Exposure During Embryogenesis and Temperature Affect Developmental Rate, Survival, and Fin Regeneration in Japanese Medaka ( Oryzias latipes )

Combined environmental stressors that an organism experiences can have both immediate and lasting consequences. In this paper we exposed medaka (Oryzias latipes) embryos to sublethal copper sulfate (CuSO 4 ) (0, 10, and 100 ppb) in combination with different rearing temperatures (27, 30, and 33°C) to assess acute and latent effects on development, growth, and regenerative capacity. Embryos exposed to CuSO 4 and/or higher temperatures hatched significantly earlier. At 4 months post-exposure, fish exposed to low levels of CuSO 4 during development had higher survival, while fish exposed to both 100 ppb CuSO 4 and 33°C temperatures had significantly lower survival. Additionally, a sex-specific effect of embryonic CuSO 4 exposure was observed as female mass decreased with increasing copper dose. We also assessed caudal fin regenerative capabilities in both embryo-exposed fish at 4 months of age and adult medaka that were exposed to 0, 10, and 100 ppb CuSO 4 at room temperature during a 14- day trial. Whereas fin regeneration was unaffected by adult exposure to copper, fish transiently exposed during embryogenesis displayed an initial increase in fin growth rate and an increased incidence of abnormal fin morphology following regrowth. Collectively, these data suggest that developmental copper exposure has the potential to exert long lasting impacts to organismal growth, survival, and function.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Stability of Radiation Induced Chromosome Damage in Human Peripheral Blood Lymphocytes

Chromosome damage in an individual's peripheral blood lymphocytes can be an indicator of radiation exposure and this data can be used to evaluate dose after accidental or occupational exposure. Evidence suggests that the yield of chromosome damage in lymphocytes is also a relevant biomarker of cancer risk in humans that reflects individual cancer susceptibility. It follows that biomonitoring studies can be used to uncover subjects who are particularly susceptible to radiation damage and therefore at higher risk of cancer. Translocations and other stable aberrations are commonly believed to persist in peripheral blood cells for many years after exposure, and it has been suggested that translocations can be used for assessing retrospective radiation doses or chronic exposures. However, recent investigations suggest that translocations might not always persist indefinitely. We measured chromosome aberrations in the blood lymphocytes of six astronauts before their respective missions of approximately 3 to 6 months onboard the international space station, and again at various intervals up to 5 years after flight. In samples collected a few days after return to earth, the yield of chromosome translocations had significantly increased compared with preflight values, and results indicate that biodosimetry estimates lie within the range expected from physical dosimetry. However, for five of the astronauts, follow up analysis revealed a temporal decline in translocations with half-lives ranging from 10 to 58 months. The yield of exchanges remained unchanged for the sixth astronaut during an observation period of 5 months post-flight. These results may indicate complications with the use of stable aberrations for retrospective dose reconstruction and could affect cancer risk predictions that are estimated from yields of chromosome damage obtained shortly after exposure.

Cucinotta, F. A.↗

Beyond Contrast Transfer: Spectral SNR as a Finite-Dose Metric for STEM Phase Retrieval

The contrast transfer function (CTF) is widely used to evaluate phase retrieval methods in scanning transmission electron microscopy (STEM), including center-of-mass imaging, parallax imaging, direct ptychography, and iterative ptychography. However, the CTF reflects only the maximum usable signal, neglecting the effects of finite electron fluence and the Poisson-limited nature of detection. As a result, it can significantly overestimate practical performance, especially in low-dose regimes. Here, we employ the spectral signal-to-noise ratio (SSNR), as a finite-dose statistical framework to evaluate the recoverable signal as a function of spatial frequency. Using numerical reconstructions of white-noise objects, we show that center-of-mass, parallax, and direct ptychography exhibit dose-independent SSNRs, with close-form analytic expressions. In contrast, iterative ptychography exhibits a surprising dose dependence: at low fluence, its SSNR converges to that of direct ptychography; at high fluence, it saturates at a value consistent with the maximum detective quantum efficiency predicted by recent quantum Fisher information bounds. The results highlight the limitations of CTF-based evaluation and motivate SSNR as a more accurate, finite-dose metric for assessing STEM phase retrieval methods.

STEM phase retrieval↗

Annual Site Environmental Report (2019)

Los Alamos National Laboratory’s (the Laboratory’s) annual site environmental reports are prepared by the Laboratory’s environmental organizations, as required by U.S. Department of Energy Order 231.1B, Administrative Change 1, Environment, Safety, and Health Reporting, and Order 458.1, Administrative Change 3, Radiation Protection of the Public and the Environment. The following chapters in this report discuss our success in complying with environmental laws, regulations, and orders (Chapter 2, Compliance Summary); how we manage the Laboratory’s environmental performance (Chapter 3, Environmental Programs); how we monitor for air emissions of radioactive materials and climate conditions (Chapter 4, Air Quality); how we monitor for effects of Laboratory operations on groundwater quality (Chapter 5, Groundwater Protection); how we monitor the movement of chemicals and radionuclides by storm water runoff and the levels of chemicals and radionuclides in deposited sediment (Chapter 6, Watershed Quality); how we monitor for the presence, levels, and effects of chemicals and radionuclides in plants, animals, and soil (Chapter 7, Ecosystem Health); and finally, what radionuclide dose or risk from chemical exposure members of the public may experience as a result of Laboratory operations (Chapter 8, Public Dose and Risk Assessment).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ASER Annual Site Environmental Report 2020

Los Alamos National Laboratory’s (the Laboratory’s) annual site environmental reports are prepared each year by the Laboratory’s environmental organizations, as required by U.S. Department of Energy Order 231.1B, Administrative Change 1, Environment, Safety, and Health Reporting, and Order 458.1, Administrative Change 4, Radiation Protection of the Public and the Environment. The following chapters in this report discuss our success in complying with environmental laws, regulations, and orders (Chapter 2, Compliance Summary); how we manage the Laboratory’s environmental performance (Chapter 3, Environmental Programs and Analytical Data Quality); how we monitor for air emissions of radioactive materials and climate conditions (Chapter 4, Air Quality); how we monitor for effects of Laboratory operations on groundwater quality (Chapter 5, Groundwater Protection); how we monitor the movement of chemicals and radionuclides by storm water runoff and the levels of chemicals and radionuclides in deposited sediment (Chapter 6, Watershed Quality); how we monitor for the presence, levels, and effects of chemicals and radionuclides in plants, animals, soil, and vegetation (Chapter 7, Ecosystem Health); and finally, what radionuclide dose or risk from chemical exposure members of the public may experience as a result of Laboratory operations (Chapter 8, Public Dose and Risk Assessment).

54 ENVIRONMENTAL SCIENCES↗

Los Alamos National Laboratory 2022 Annual Site Environmental Report (Rev. 2)

Los Alamos National Laboratory (Laboratory) annual site environmental reports are prepared each year by the Laboratory’s environmental organizations as required by U.S. Department of Energy Order 231.1B, Administrative Change 1, Environment, Safety, and Health Reporting, and Order 458.1, Administrative Change 4, Radiation Protection of the Public and the Environment. The chapters in this report discuss our compliance with environmental laws, regulations, and orders (Chapter 2, Compliance Summary); how we manage the Laboratory’s environmental performance and assure the quality of data from analysis of environmental samples (Chapter 3, Environmental Programs and Analytical Data Quality); how we monitor for air emissions of radioactive materials and for weather conditions (Chapter 4, Air Quality); how we monitor for effects of Laboratory operations on groundwater quality (Chapter 5, Groundwater Protection); how we monitor the levels of chemicals and radionuclides in storm water runoff and sediment (Chapter 6, Watershed Quality); how we monitor for the levels and effects of chemicals and radionuclides in plants, animals, soil, and vegetation (Chapter 7, Ecosystem Health); and finally, what radioactive dose or risk from chemical exposure that members of the public could experience as a result of Laboratory operations (Chapter 8, Public Dose and Risk Assessment).

54 ENVIRONMENTAL SCIENCES↗

Radiation: Physical Characterization and Environmental Measurements

In this session, Session WP4, the discussion focuses on the following topics: Production of Neutrons from Interactions of GCR-Like Particles; Solar Particle Event Dose Distributions, Parameterization of Dose-Time Profiles; Assessment of Nuclear Events in the Body Produced by Neutrons and High-Energy Charged Particles; Ground-Based Simulations of Cosmic Ray Heavy Ion Interactions in Spacecraft and Planetary Habitat Shielding Materials; Radiation Measurements in Space Missions; Radiation Measurements in Civil Aircraft; Analysis of the Pre-Flight and Post-Flight Calibration Procedures Performed on the Liulin Space Radiation Dosimeter; and Radiation Environment Monitoring for Astronauts.

Source record↗

Influence of neutron cross-section resonances on organ/tissue equivalent and effective dose coefficients for the ICRP voxel phantoms

The materials which compose the ICRP Voxel phantoms used in the computation of conversion coefficients involve neutron interaction cross-sections that have resonances at specific energies. Depending on the energy bin structure used in the computations, these cross-section resonances may occur at energies that fall between energies at which dose coefficients are computed, thus their effects may not be completely accounted for in the reported coefficients. Here In this study, a highly refined energy grid that closely follows the resonance structure in the phantom material cross-sections was identified and used to calculate dose coefficients. Both the equivalent organ/tissue doses for male and female voxel phantoms were computed as well as their summation to obtain the effective dose coefficients. The used refined energy grid tracks very closely the cross-sections in the vicinity of the resonances. The resulting refined energy grid coefficients are compared to coefficients for the coarser energy grid used in ICRP Publication 116. Additionally, reference spectra have been folded with both the fine and coarse sets of conversion coefficients. The resulting total effective doses for these reference spectra are used to assess the adequacy of the dose coefficients calculated on the original ICRP 116 energy grid. The dose coefficients were similarly computed for the local skin dose on the trunk of the body using the ICRU Report 95 phantom. The overall impact of the resonances on the organ/tissue equivalent dose, the effective dose, and the local skin dose are presented and discussed. In general, it was found that resonances can impact neutron dose coefficients, but in most cases the wide range of neutron energies encountered minimized this effect. The impact of resonances was further limited when computing effective dose due to organ/tissue summing and sex-averaging. For the neutron fields studied here, the impact was below 5%.

36 MATERIALS SCIENCE↗

Toward an effective use of laser-driven very high energy electrons for radiotherapy: Feasibility assessment of multi-field and intensity modulation irradiation schemes

Radiotherapy with very high energy electrons has been investigated for a couple of decades as an effective approach to improve dose distribution compared to conventional photon-based radiotherapy, with the recent intriguing potential of high dose-rate irradiation. Its practical application to treatment has been hindered by the lack of hospital-scale accelerators. High-gradient laser-plasma accelerators (LPA) have been proposed as a possible platform, but no experiments so far have explored the feasibility of a clinical use of this concept. We show the results of an experimental study aimed at assessing dose deposition for deep seated tumours using advanced irradiation schemes with an existing LPA source. Measurements show control of localized dose deposition and modulation, suitable to target a volume at depths in the range from 5 to 10 cm with mm resolution. The dose delivered to the target was up to 1.6 Gy, delivered with few hundreds of shots, limited by secondary components of the LPA accelerator. Measurements suggest that therapeutic doses within localized volumes can already be obtained with existing LPA technology, calling for dedicated pre-clinical studies.

59 BASIC BIOLOGICAL SCIENCES↗

Quantitative assessment of the cataractogenic potential of very low doses of neutrons

We report on the prevalence and relative biological effectiveness (RBE) for various stages of lens opacification in rats induced by very low doses (2 to 250 mGy) of medium-energy (440 keV) neutrons, compared to those for X rays. Neutron doses were delivered either in a single fraction or in four separate fractions and the irradiated animals were followed for over 100 weeks. At the highest observed dose (250 mGy) and at early observation times, there was evidence of an inverse dose-rate effect; i.e., a fractionated exposure was more potent than a single exposure. Neutron RBEs relative to X rays were estimated using a non-parametric technique. The results were only weakly dependent on time postirradiation. At 30 weeks, for example, 80% confidence intervals for the RBE of acutely delivered neutrons relative to X rays were 8-16 at 250 mGy, 10-20 at 50 mGy, 50-100 at 10 mGy and 250-500 at 2 mGy. The results are consistent with the estimated neutron RBEs in Japanese A-bomb survivors, though broad confidence bounds are present in the Japanese results. Our findings are also consistent with data reported earlier for cataractogenesis induced by heavy ions in rats, mice, and rabbits. We conclude from these results that, at very low doses (<10 mGy), the RBE for neutron-induced cataractogenesis is considerably larger than the RBE of 20 commonly used, and use of a significantly larger value for calculating equivalent dose would be prudent.

NASA Discipline Radiation Health↗

Estimation Methodology to Evaluate Hypothetical Downwind Impacts from Fusion Plants

The continuing move toward establishing fusion systems for power generation and the associated research to that end is prompting examination of the potential health and safety impacts of such plants to the environment and human health. As many fusion facilities will have tritium inventories on site as part of the fusion fuel, evaluating the potential for downwind impacts from fusion facilities or power plants resulting from accident or routine emissions is a general requirement for assessing location and impacts to workers and the public. As part of siting considerations and permitting, the fusion facilities would be evaluated for potential for downwind concentration and dose impacts. For accident assessment scenarios, the downwind impacts are usually modeled as an instantaneous (or near-instantaneous) release of material transported following the wind. A range of meteorological conditions are usually assessed to determine a bounding case which results in a dose exceeding a specified threshold (e.g., 95 th or 99 th percentile; DOE 2015). This report provides initial estimates of the downwind dose impacts from a potential tritium release at a fusion power plant-relevant facility and identifies potential distances required to limit impacts to nearby population. This effort is meant to provide a bounding analysis and theoretical understanding of impacts of tritium releases for facilities subject to various environmental and atmospheric conditions. Using a Gaussian dispersion model to simulate a brief plume, downwind concentration and dose is projected for tritium oxide. Releases are assumed to consist entirely of tritium oxide due to the increased dose impacts from the oxide form relative to the elemental form of tritium. We also briefly identify how climatological conditions could potentially be used to support risk profile determination.

54 ENVIRONMENTAL SCIENCES↗