Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distribution system voltage control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Data-Driven Global Sensitivity Analysis of Three-Phase Distribution System with PVs

Global sensitivity analysis (GSA) of distribution system with respect to stochastic PV variations plays an important role in designing optimal voltage control schemes. This paper proposes a Kriging, i.e., Gaussian process modeling enabled data-driven GSA method. The key idea is to develop a surrogate model that captures the hidden global relationship between voltage and real and reactive power injections from the historical data. With the surrogate model, the Sobol index can be conveniently calculated to assess the global sensitivity of voltage to various power injection variations. Comparison results with other model-based GSA methods on the IEEE 37-bus feeder, such as the polynomial chaos expansion and the Monte Carlo approaches demonstrate that the proposed method can achieve accurate GSA outcomes while maintaining high computational efficiency.

distribution system analysis↗

Adaptive primal–dual control for distributed energy resource management

With the increased adoption of distributed energy resources (DERs) in distribution networks, their coordinated control with a DER management system (DERMS) that provides grid services (e.g., voltage regulation, virtual power plant) is becoming more necessary. One particular type of DERMS using primal–dual control has recently been found to be very effective at providing multiple grid services among an aggregation of DERs; however, the main parameter, the primal–dual step size, must be manually tuned for the DERMS to be effective, which can take a considerable amount of engineering time and labor. To this end, we design a simple method that self-tunes the step size(s) and adapts it to changing system conditions. Additionally, it gives the DER management operator the ability to prioritize among possibly competing grid services. Here we evaluate the automatic tuning method on a simulation model of a real-world feeder in Colorado with data obtained from an electric utility. Through a variety of scenarios, we demonstrate that the DERMS with automatically and adaptively tuned step sizes provides higher-quality grid services than a DERMS with a manually tuned step size.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Privacy Preserving Distributed Model Identification Algorithm for Power Distribution Systems

Distributed control/optimization is a promising approach for network systems due to its advantages over centralized schemes, such as robustness, cost-effectiveness, and improved privacy. However, distributed methods can have drawbacks, such as slower convergence rates due to limited knowledge of the overall network model. Additionally, ensuring privacy in the communication of sensitive information can pose implementation challenges. To address this issue, we propose a distributed model identification algorithm that enables each agent to identify the sub-model that characterizes the relationship between its local control and the overall system outputs. The proposed algorithm maintains the privacy of local agents by only communicating through dummy variables. We demonstrate the efficacy of our algorithm in the context of power distribution systems by applying it to the voltage regulation of a modified IEEE distribution system. The proposed algorithm is well-suited to the needs of power distribution controls and offers an effective solution to the challenges of distributed model identification in network systems.

data-driven modeling↗

A Privacy Preserving Distributed Model Identification Algorithm for Power Distribution Systems: Preprint

Distributed control/optimization is a promising approach for network systems due to its advantages over centralized schemes, such as robustness, cost-effectiveness, and improved privacy. However, distributed methods can have drawbacks, such as slower convergence rates due to limited knowledge of the overall network model. Additionally, ensuring privacy in the communication of sensitive information can pose implementation challenges. To address this issue, we propose a distributed model identification algorithm that enables each agent to identify the sub-model that characterizes the relationship between its local control and the overall system outputs. The proposed algorithm maintains the privacy of local agents by only communicating through dummy variables. We demonstrate the efficacy of our algorithm in the context of power distribution systems by applying it to the voltage regulation of a modified IEEE distribution system. The proposed algorithm is well-suited to the needs of power distribution controls and offers an effective solution to the challenges of distributed model identification in network systems.

data-driven modeling↗

Grid Value Investigation of Medium-Voltage Back-to-Back Converters

This paper presents the results of an investigation into the value that medium voltage back-to-back (MVB2B) converters can be realized through two potential applications: voltage regulation via the provision of reactive power supply or absorption, and distributed energy resource (DER) hosting capacity improvement via the controlled transfer of real power within the distribution system. Two groups of distribution systems have been prepared for the value investigation: the IEEE 123-bus system for the voltage regulation study and two utility-provided, realistic distribution systems for the DER hosting capacity improvement study. The results demonstrate that the MVB2B converter can realize significant value for the grid through these two applications. In particular, with the MVB2B converter transferring power between two feeders, DER-based power can be routed to nearby loads instead of feed through the distribution substation. Additionally, the size of energy storage elements used to enable higher levels of DERs can be significantly reduced.

28 EE - Advanced Manufacturing Office (EE-5A)↗

Single-Phase to Split-Phase Inverters with Advanced Grid Support Functions for Grid-Interactive Applications

This work presents a cost-effective single-phase to split-phase inverter with a reduced switch count, achieving grid interactive performance while maintaining operational efficiency. The proposed system integrates an Andronov-Hopf oscillator based secondary controller, which inherently embeds a nonlinear resistive droop architecture, ensuring rapid dynamic response. A Lyapunov energy function-based primary control enhances transient stability and regulation, while an internal model-based point of common coupling voltage estimation enables cost optimization without additional sensors. Equipped with advanced grid support functionalities, the inverter facilitates seamless distribution system operation with enhanced robustness. The effectiveness of the proposed architecture and control strategy is validated through MATLAB/Simulink and PLECS simulations, demonstrating its feasibility for high-performance grid-supportive applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

WAMS-Based HVDC Damping Control for Cyber Attack Defense

Owing to the fast and large power regulating the capacity of the HVDC system, the wide-area measurement system (WAMS) based high voltage direct current (HVDC) system has been regarded as a prospective solution to deal with the low-frequency oscillation issue. However, due to the vulnerability of the WAMS communication, WAMS based HVDC system control can be a prime target of malicious penetrations that could lead to disastrous events. To remediate this adverse effect, an improved WAMS based HVDC damping control framework is proposed in this paper. First, a lightweight network named Attack Shuffle convolutional neural Networks (ASNet) is proposed to learn the characteristics of cyber attacks. Then, a model-free-based cyber attack defense framework is introduced to quickly identify the attack types based on the continuous wavelet transform and ASNet. Additionally, an improved control framework of the WAMS and HVDC-based wide-area power oscillation damping control (WH-PODC) is developed to provide different response control for mitigation of the impact of cyber attacks. Finally, the performance of the proposed WH-PODC control framework is evaluated with real PMU data in multiple scenarios in RTDS, where the results indicate that the response intensity can be kept under multiple types of cyber attacks while providing similar effectiveness in oscillation suppression to conventional controls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Two-Stage Deep Reinforcement Learning for Distribution System Voltage Regulation and Peak Load Management

The growing integration of distributed solar photovoltaic (PV) in distribution systems could result in adverse effects during grid operation. This paper develops a two-agent soft actor critic-based deep reinforcement learning (SAC-DRL) solution to simultaneously control PV inverters and battery energy storage systems for voltage regulation and peak demand reduction. The novel two-stage framework, featured with two different control agents, is applied for daytime and nighttime operations to enhance control performance. Comparison results with other control methods on a real feeder in Western Colorado demonstrate that the proposed method can provide advanced voltage regulation with modest active power curtailment and reduce peak load demand from feeder's head.

deep reinforcement learning↗

Voltage regulation in distribution grids: A survey

Environmental and sustainability concerns have caused a recent surge in the penetration of distributed energy resources into the power grid. This may lead to voltage violations in the distribution systems making voltage regulation more relevant than ever. Owing to this and rapid advancements in sensing, communication, and computation technologies, the literature on voltage control techniques is growing at a rapid pace in distribution networks. In particular, there is a paradigm shift from traditional offline centralized approaches to distributed ones leveraging increased and varied types of actuators, real-time sensing, fast and efficient computations, and an overall distributed situational awareness. This paper reviews state-of-the-art voltage control algorithms, summarizes the underlying methods, and classifies their coordination mechanisms into local, centralized, distributed, and decentralized. The underlying solution methodologies are further classified into two categories, open-loop and feedback-based. Two specific example workflows are provided to illustrate these solutions for voltage regulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Optimization in Distribution Systems: Use Cases, Limitations, and Research Needs

We report electric distribution grid operations typically rely on both centralized optimization and local non-optimal control techniques. As an alternative, distribution system operational practices can consider distributed optimization techniques that leverage communications among various neighboring agents to achieve optimal operation. With the rapidly increasing integration of distributed energy resources (DERs), distributed optimization algorithms are growing in importance due to their potential advantages in scalability, flexibility, privacy, and robustness relative to centralized optimization. Implementation of distributed optimization offers multiple challenges and also opportunities. This paper provides a comprehensive review of the recent advancements in distributed optimization for electric distribution systems and classifications using key attributes. Problem formulations and distributed optimization algorithms are provided for example use cases, including volt/var control, market clearing process, loss minimization, and conservation voltage reduction. Finally, this paper also presents future research needs for the applicability of distributed optimization algorithms in the distribution system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data-driven based coordinated smart inverter control for distributed energy resources

Smart inverters (SI) for distributed energy resources (DER) are becoming popular since they have the ability to stabilize as well as restore the voltage and frequency of power systems. Aiming at establishing the mathematical models combined with SI control methods, multiple optimization methods are developed. However, the computational complexity of solving such a mathematical model with various uncertainties limits the real-time application of the SI control. To conquer this challenge, a data-driven-based SI control approach is developed to achieve coordinated control in the high penetration DER system. First, an optimization problem for maximizing the active power generation and minimizing the power loss is designed using the Volt/VAR control. To reduce the time consumption, the recurrent neural network (RNN) is proposed to model the relationship between the uncertainties and control actions during the offline site. The RNN with different sub-structures such as the long short-term memory cell and gated recurrent unit cell are included to enrich the diversity of features. In the last stage, different experiment comparisons, including multiple uncertainties maps and stateof- art machine learning methods, are conducted to verify the effectiveness of the proposed method based on the IEEE 123 bus power system. The results demonstrate that the proposed method can effectively achieve a rapid and coordinated control with a lower error rate.

Qiu, Wei↗

A Machine Learning-Based Method to Estimate Transformer Primary-Side Voltages with Limited Customer-Side AMI Measurements

Distribution control applications such as volt/var optimization, network reconfiguration, and distribution automation require accurate knowledge of the distribution system state. The lack of sufficient sensors on the primary side of distribution networks often limits the accuracy of the control decisions by these applications. The deployment of advanced metering infrastructure (AMI) provides utilities an opportunity to translate the AMI data on the secondary onto the primary so that it can be used as pseudo-measurements to augment the limited existing measurements on the primary. This paper develops an approach for estimating service transformer primary-side voltages by using limited secondary-side AMI measurements. The estimated primary-side voltages can be used by utilities as pseudo-measurements for distribution control applications. The detailed secondary model topology, which is an essential input data for many existing algorithms, is not required for the proposed method. The performance of the proposed method is validated by using AMI measurements from the field and an actual distribution feeder model of San Diego Gas & Electric Company.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Soft-Fault Detection Technologies Developed for Electrical Power Systems

The NASA Glenn Research Center, partner universities, and defense contractors are working to develop intelligent power management and distribution (PMAD) technologies for future spacecraft and launch vehicles. The goals are to provide higher performance (efficiency, transient response, and stability), higher fault tolerance, and higher reliability through the application of digital control and communication technologies. It is also expected that these technologies will eventually reduce the design, development, manufacturing, and integration costs for large, electrical power systems for space vehicles. The main focus of this research has been to incorporate digital control, communications, and intelligent algorithms into power electronic devices such as direct-current to direct-current (dc-dc) converters and protective switchgear. These technologies, in turn, will enable revolutionary changes in the way electrical power systems are designed, developed, configured, and integrated in aerospace vehicles and satellites. Initial successes in integrating modern, digital controllers have proven that transient response performance can be improved using advanced nonlinear control algorithms. One technology being developed includes the detection of "soft faults," those not typically covered by current systems in use today. Soft faults include arcing faults, corona discharge faults, and undetected leakage currents. Using digital control and advanced signal analysis algorithms, we have shown that it is possible to reliably detect arcing faults in high-voltage dc power distribution systems (see the preceding photograph). Another research effort has shown that low-level leakage faults and cable degradation can be detected by analyzing power system parameters over time. This additional fault detection capability will result in higher reliability for long-lived power systems such as reusable launch vehicles and space exploration missions.

Button, Robert M.↗

Space Shuttle Upgrades Advanced Hydraulic Power System

Three Auxiliary Power Units (APU) on the Space Shuttle Orbiter each provide 145 hp shaft power to a hydraulic pump which outputs 3000 psi hydraulic fluid to 41 hydraulic actuators. A hydrazine fuel powered APU utilized throughout the Shuttle program has undergone many improvements, but concerns remain with flight safety, operational cost, critical failure modes, and hydrazine related hazards. The advanced hydraulic power system (AHPS), also known as the electric APU, is being evaluated as an upgrade to replace the hydrazine APU. The AHPS replaces the high-speed turbine and hydrazine fuel supply system with a battery power supply and electric motor/pump that converts 300 volt electrical power to 3000 psi hydraulic power. AHPS upgrade benefits include elimination of toxic hydrazine propellant to improve flight safety, reduction in hazardous ground processing operations, and improved reliability. Development of this upgrade provides many interesting challenges and includes development of four hardware elements that comprise the AHPS system: Battery - The battery provides a high voltage supply of power using lithium ion cells. This is a large battery that must provide 28 kilowatt hours of energy over 99 minutes of operation at 300 volts with a peak power of 130 kilowatts for three seconds. High Voltage Power Distribution and Control (PD&C) - The PD&C distributes electric power from the battery to the EHDU. This 300 volt system includes wiring and components necessary to distribute power and provide fault current protection. Electro-Hydraulic Drive Unit (EHDU) - The EHDU converts electric input power to hydraulic output power. The EHDU must provide over 90 kilowatts of stable, output hydraulic power at 3000 psi with high efficiency and rapid response time. Cooling System - The cooling system provides thermal control of the Orbiter hydraulic fluid and EHDU electronic components. Symposium presentation will provide an overview of the AHPS upgrade, descriptions of the four hardware elements, and a summary of development results to date.

Source record↗

A Machine Learning-Based Method to Estimate Transformer Primary-Side Voltages with Limited Customer-Side AMI Measurements

Distribution control applications such as volt/var optimization, network reconfiguration, and distribution automation require accurate knowledge of the distribution system state. The lack of sufficient sensors on the primary side of distribution networks often limits the accuracy of the control decisions by these applications. The deployment of advanced metering infrastructure (AMI) provides utilities an opportunity to translate the AMI data on the secondary onto the primary so that it can be used as pseudo-measurements to augment the limited existing measurements on the primary. This paper develops a machine learning based approach for estimating service transformer primary-side voltages by using limited secondary-side AMI measurement. The machine learning model is developed by using random forest algorithm. The estimated primary-side voltages can be used by utilities as pseudo-measurements for distribution control applications. The detailed secondary model topology, which is an essential input data for many existing algorithms, is not required for the proposed method. The performance of the proposed method is validated by using AMI measurements from the field and an actual distribution feeder model of San Diego Gas & Electric Company.

advanced metering infrastructure↗

Network-cognizant voltage droop control

The present disclosure provides techniques for network-cognizant droop control in power systems, such as a power distribution system. An example device includes a processor configured to determine, based on (i) a model representing a structure of a power system that includes a plurality of energy resources and (ii) an indication of predicted uncontrollable power injections in the power system, for each controllable energy resource in the plurality of energy resources, a respective value of a first droop coefficient and a respective value of a second droop coefficient. The processor may be further configured to cause at least one controllable energy resource in the plurality of energy resources to modify an output power of the at least one energy resource based on the respective value of the first droop coefficient and the respective value of the second droop coefficient.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Adaptive Deep Reinforcement Learning Algorithm for Distribution System Cyber Attack Defense With High Penetration of DERs

With grid modernization, smart inverters are increasingly used to execute advanced controls for distribution network reliability. However, this also increases the cyber-attack space. Here this paper focuses on the defense approaches to restore the system to normal operation circumstances in the presence of cyber-attacks. A unique deep reinforcement learning (DRL) method is developed to minimize voltage violations and reduce power losses for impacted feeders. The defense problem is reformulated as a Markov decision-making process to dynamically control DERs while minimizing load shedding. This is achieved via an improved soft actor-critic (SAC)-based DRL algorithm, which can govern DER set points and load-shedding scenarios in discrete and continuous modes via the auto-tune entropy and Gaussian policy features. Numerical comparison results on the modified IEEE 123-node system with other control approaches, such as Volt-VAR (VV), Volt-Watt (VW), and model predictive control (MPC) show that the proposed method can eliminate voltage violations and provide feasible control actions that perform complete mitigation of cyber-threats.

24 POWER TRANSMISSION AND DISTRIBUTION↗