Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distribution monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

XML-Based Visual Specification of Multidisciplinary Applications

The advancements in the Internet and Web technologies have fueled a growing interest in developing a web-based distributed computing environment. We have designed and developed Arcade, a web-based environment for designing, executing, monitoring, and controlling distributed heterogeneous applications, which is easy to use and access, portable, and provides support through all phases of the application development and execution. A major focus of the environment is the specification of heterogeneous, multidisciplinary applications. In this paper we focus on the visual and script-based specification interface of Arcade. The web/browser-based visual interface is designed to be intuitive to use and can also be used for visual monitoring during execution. The script specification is based on XML to: (1) make it portable across different frameworks, and (2) make the development of our tools easier by using the existing freely available XML parsers and editors. There is a one-to-one correspondence between the visual and script-based interfaces allowing users to go back and forth between the two. To support this we have developed translators that translate a script-based specification to a visual-based specification, and vice-versa. These translators are integrated with our tools and are transparent to users.

Al-Theneyan, Ahmed↗

Seismic Monitoring near Ithaca, New York, Reveals Nonuniform Distribution of Microseismicity in an Intraplate Region

Abstract Cornell University intends to use a deep direct-use geothermal system to heat its Ithaca, New York, campus. In preparation for this project, the Cornell Seismic Network has been monitoring the background seismicity in this intraplate region since 2019. From January 2020 to June 2023, 95 events were detected within 20 km of the proposed geothermal well site, with local magnitudes ranging from −1.02 to 0.56. None of these events appear in regional or national catalogs. Events locate in a narrow geographic band, with one-fourth exhibiting multimodal hypocentral probability peaks both near the surface and at 1–4 km depth. We relocate events with a joint hypocenter and 1D velocity model inversion, in addition to a fully nonlinear method, and then compare observations with synthetic waveforms. Together, these approaches provide strong evidence for >95% of events locating at the surface or within the 3-km-thick sedimentary sequence. We explore how anthropogenic activity and regional topographic stress may contribute to frequent surficial events. This information is critical for characterizing the background microseismicity for comparison during future geothermal operations. Ithaca’s geology of Paleozoic sediments overlying Precambrian crystalline basement is typical of many continental interiors, so these results also provide insight into intraplate microseismicity patterns.

Geochemistry & Geophysics↗

Toward local core outlet temperature monitoring in gas-cooled nuclear reactors using distributed fiber-optic temperature sensors

Gas-cooled nuclear reactors operate at temperatures up to 950 °C with significant spatial variations in power generation and coolant flow through hundreds of parallel flow channels, resulting in complex mixing at the core outlet. The high temperatures and complex mixing can damage downstream components, challenge reactor calorimetry for power determination, and result in significant conservatism in calculated peak fuel temperatures, which ultimately limits the total power output. Directly measuring each gas stream individually is unrealistic using single point thermocouples, requiring more robust sensing techniques. Fiber-optic sensors are resilient to high temperatures (up to 1,000 °C) and radiation damage. Moreover, distributed measurements can be made along the length of one fiber, making them potential candidates for monitoring local core outlet temperatures to improve core calorimetry and identify hot channels. Here, to the authors’ knowledge, this manuscript is the first to report spatially distributed fiber optic temperature measurements to quantify mixing at the outlet of a relevant orifice plate under prototypic temperature and flow regimes to assess the feasibility of using fiber-optic sensors for distributed measurements of coolant temperature in gas-cooled reactors. A single optical fiber captured dynamic changes in local temperatures, whereas the mixed outlet temperature exhibited a muted response and could not identify which channels were responsible for the change in the mixed outlet temperature. The discussion focuses on potential challenges for deploying distributed optical fibers in gas-cooled reactors, including the effects of vibrations, radiation-induced signal attenuation and drift, and routing of the fiber while minimizing flow obstructions.

42 ENGINEERING↗

Vertical Characterization of Flow and Contaminant Concentration in New Hanford Extraction Wells

Effective groundwater remediation should focus on high-concentration, low-permeability zones within the aquifer, as these areas often present significant challenges to contaminant removal. Characterizing the vertical distribution of contamination in an aquifer is therefore critical for optimizing and monitoring pump-and-treat (P&T) systems to meet target cleanup timelines. Flow patterns driven by hydraulic gradients and variations in permeability are described to provide insight into contaminant mass removal from long-screened wells. The objective of this multi-phase work is to provide actionable recommendations for improving remedy performance monitoring and P&T operations, which ongoing evaluations will address. This report summarizes the preliminary results of vertical flow and contaminant distribution monitoring in new extraction wells at the Hanford Site.

54 ENVIRONMENTAL SCIENCES↗

Atmospheric Ozone 1985. Assessment of Our Understanding of the Processes Controlling Its Present Distribution and Change, Volume 1: Global Ozone Research and Monitoring Project - Report No. 16

Topics addressed include: stratospheric chemistry; tropospheric trace gas (sources, distributions, and trends); tropospheric chemistry (processes, controlling the ozone and hydroxyl radicals); stratosphere-troposphere exchange; dynamic processes; and radiative processes (solar and terrestrial).

Source record↗

Disparities in the air quality monitoring stations and PM₂.₅ in Chicago’s air quality landscape

Fine particulate matter (PM₂.₅) poses significant public and environmental health risks in urban areas. Chicago’s dense industry and traffic create variable air quality, yet monitoring is unevenly distributed, resulting in undersampling of air quality data in some city areas. This study applied a hybrid approach using GIS-based kernel density mapping, interpolation modeling (IDW, Spline, Kriging) of USEPA monitoring data, multi-scale temporal trend analyses (hourly to annual), and ESDA. Accordingly, the density surface showed that monitors are concentrated in the affluent north, northwest, and southwest sides of Chicago (up to ~ 0.07 stations per sq mile), while the south and southeast regions, with predominantly minority communities, have virtually no coverage. Overall, citywide coverage is minimal (~ 4–5 monitors total; ~0.02 per sq mile; ≈1 per 600,000 residents). Temporal analyses showed that the city’s mean annual PM₂.₅ (~ 10.8 µg/m³) exceeds USEPA/WHO standards (9 µg/m³), with summer means (~ 17.1 µg/m³) significantly higher than other seasons. Diurnally, a clear pattern was observed, with PM₂.₅ concentrations peaking overnight (00:00–03:00) and during the morning rush hours, and dipping during midday to late afternoon. Spatial distribution of PM₂.₅ identified hotspots near O’Hare Airport, the downtown Loop area, and south-side neighborhoods, contrasting with lower concentrations on the north side, revealing Chicago’s socioeconomic divides and resulting environmental inequities. The findings underscore the need for expanded monitoring and targeted interventions in under-monitored, high-pollution communities to advance equitable community health.

54 ENVIRONMENTAL SCIENCES↗

Direct observation of strain-enhanced hydrogen segregation and failure at high-angle grain boundaries in nickel

Understanding the mechanisms underlying hydrogen embrittlement remains difficult, even in single-element metals. Both microstructure and stress state influence hydrogen distribution in metals and alloys, which impacts deformation and failure. Here, in this work, we use in-situ Kelvin probe force microscopy (KPFM) to monitor the hydrogen distribution in pure nickel over time at 1.1 % and 3.5 % strain. The sample strained to 3.5 % results in preferential hydrogen segregation to high-angle grain boundaries whereas the sample strained to 1.1 % does not exhibit preferential hydrogen segregation. Optical digital image correlation (DIC) shows that hydrogen charging results in both localized and reduced strains during tensile testing of a notched sample. Later stages of deformation and failure (e.g. microcracking) are studied by using in-situ transmission X-ray microscopy (TXM). TXM reveals nanoscale structural changes to a propagating crack in a hydrogen environment. Localized void growth and secondary cracking occur at grain boundaries near the primary crack front. Correlative electron backscattering diffraction (EBSD) is used to relate the cracking at grain boundaries to the hydrogen segregation observed in KPFM. These findings are unified in a proposed hydrogen embrittlement mechanism that describes the interaction of hydrogen with grain boundaries, and the role of grain boundaries in hydrogen embrittlement.

Grain boundary fracture↗

Autonomous Mission Operations Roadmap

As light time delays increase, the number of such situations in which crew autonomy is the best way to conduct the mission is expected to increase. However, there are significant open questions regarding which functions to allocate to ground and crew as the time delays increase. In situations where the ideal solution is to allocate responsibility to the crew and the vehicle, a second question arises: should the activity be the responsibility of the crew or an automated vehicle function? More specifically, we must answer the following questions: What aspects of mission operation responsibilities (Plan, Train, Fly) should be allocated to ground based or vehicle based planning, monitoring, and control in the presence of significant light-time delay between the vehicle and the Earth?How should the allocated ground based planning, monitoring, and control be distributed across the flight control team and ground system automation? How should the allocated vehicle based planning, monitoring, and control be distributed between the flight crew and onboard system automation?When during the mission should responsibility shift from flight control team to crew or from crew to vehicle, and what should the process of shifting responsibility be as the mission progresses? NASA is developing a roadmap of capabilities for Autonomous Mission Operations for human spaceflight. This presentation will describe the current state of development of this roadmap, with specific attention to in-space inspection tasks that crews might perform with minimum assistance from the ground.

Mission Operations↗

Deep Neural Network Assisted Distributed Strain and Temperature Fiber Sensor System for Natural Gas Pipeline Monitoring

Natural gas pipeline integrity monitoring is crucial to detect potential leaks, find structural issues, and prevent environmental damage. This article presents a system of natural gas pipeline monitoring that uses a specialized double Brillouin peak sensing fiber along with the Brillouin optical time domain analysis (BOTDAs) technique. The calibrated sensing fiber coefficients for strain and temperature are 41.8 kHz/ με and 0.9 MHz/°C for peak 1; and 47.2 kHz/ με , and 1.11 MHz/°C for peak 2, respectively. Initially, lab tests were performed by installing a short section of double Brillouin peak fiber (DBPF) on a 1-in steel pipe under pressure up to 1000 per square inch (psi) at elevated temperatures. Simultaneous distributed measurements of temperature and pressure-induced hoop strain were successfully measured. Considering the long processing speed to extract Brillouin frequency shift (BFS), we employ a novel probabilistic deep neural network (PDNN) framework for rapid BFS prediction. Additionally, using the Finite Element Method, the effects of the pipeline pressure on hoop strain were modeled and compared to the experimental hoop strain under the same set of pipeline conditions. Finally, an actual 4-in outer diameter steel natural gas pipeline was used for pilot-scale tests, where hoop strain was measured at various pressure levels. Leaks were simulated to demonstrate accurate pipeline integrity monitoring. At an internal pipe pressure of 1000 psi, hoop strain of approximately 300 με was observed, and the sensitivity was calculated as 0.28 με /psi. The results of this pilot-scale study demonstrated that the system is capable of performing distributed monitoring sufficient to detect pipeline pressure and the presence of leaks to ensure the safe operation of gas pipelines in the field.

03 NATURAL GAS↗

Casing Annulus Monitoring of CO 2 Injection Using Wireless Autonomous Distributed Sensor Networks

Effective and secure carbon subsurface storage, involving the deep underground injection of CO 2 into geological formations where it is permanently trapped, is paramount to mitigating CO 2 emissions (Figure I). Ensuring the integrity of these storage sites and detecting potential leakage through the casing annulus necessitates robust monitoring. This work provides the first integrated demonstration of a wireless casing-annulus monitoring architecture that can operate in highly attenuating cement-brine environments relevant to CO 2 storage. This project focused on developing and validating a novel sensor system for integration with autonomous monitoring near the cement reservoir interface. The goal was a fully integrated Technology Readiness Level (TRL) 4/5 field validation of a distributed wireless intelligent sensor system providing real-time, direct subsurface formation measurements to enhance fluid movement monitoring in the cemented casing annulus. Achieving this objective required the development and integration of 1) wireless autonomous microsensor technology by California Institute of Technology (Caltech); 2) sensor packaging and emplacement technology by Research Triangle Institute (RTI); and 3) smart well completions using wireless active casing collars and NOV pipe by the Sandia National Lab (SNL). The collaboration with the Caltech team in this project aimed to develop millimeter-scale radio frequency identification (RFID) sensors capable of detecting CO 2 , pH, and/or methane levels. These sensors are engineered to be impervious to fluids, allowing them to be mixed with cement and installed within the casing annulus. They operate using RFID protocols at frequencies of 902–928 MHz for both power and communication. A Sandia National Laboratories’ team engaged their expertise in the development of a Smart Collar system designed for the wireless data collection from these RFID sensors embedded in the cement annulus and transmission of this information to the ground surface via IntelliPipe/IntelliServ NOV drill pipe. This is accomplished through inductive coupling at the collar, which facilitates data transfer through each segment of the pipe. Because the system cannot transmit a direct current signal to power the Smart Collar, both power and communication were implemented using alternating current and electromagnetic signals at varying frequencies. Furthermore, the developed microsensor technology had to be demonstrated and validated in comparison with reference transducer measurements in a field test site at The University of Texas at Austin (UT-Austin). Although the full sensor suite did not reach field-deployment readiness, the system-level integration achieved in this project establishes a validated pathway for future incorporation of advanced microsensors.

47 OTHER INSTRUMENTATION↗

Arcade: A Web-Java Based Framework for Distributed Computing

Distributed heterogeneous environments are being increasingly used to execute a variety of large size simulations and computational problems. We are developing Arcade, a web-based environment to design, execute, monitor, and control distributed applications. These targeted applications consist of independent heterogeneous modules which can be executed on a distributed heterogeneous environment. In this paper we describe the overall design of the system and discuss the prototype implementation of the core functionalities required to support such a framework.

Chen, Zhikai↗

Polarimetric Remote Sensing of Atmospheric Aerosols: Instruments, Methodologies, Results, and Perspectives

Polarimetry is one of the most promising types of remote sensing for improved characterization of atmospheric aerosol. Indeed, aerosol particles constitute a highly variable atmospheric component characterized by a large number of parameters describing particle sizes, morphologies (including shape and internal structure), absorption and scattering properties, amounts, horizontal and vertical distribution, etc. Reliable monitoring of all these parameters is very challenging, and therefore the aerosol effects on climate and environment are considered to be among the most uncertain factors in climate and environmental research. In this regard, observations that provide both the angular distribution of the scattered atmospheric radiation as well as its polarization state at multiple wavelengths covering the UV–SWIR spectral range carry substantial implicit information on the atmospheric composition. Therefore, high expectations in improving aerosol characterization are associated with detailed passive photopolarimetric observations. The critical need to use space-borne polarimetry for global accurate monitoring of detailed aerosol properties was first articulated in the late 1980s and early 1990s. By now, several orbital instruments have already provided polarization observations from space, and a number of advanced missions are scheduled for launch in the coming years by international and national space agencies. The first and most extensive record of polarimetric imagery was provided by POLDER-I, POLDER-II, and POLDER/PARASOL multi-angle multi-spectral polarization sensors. Polarimetric observations with the POLDER-like design intended for collecting extensive multi-angular multi-spectral measurements will be provided by several instruments, such as the MAI/TG-2, CAPI/TanSat, and DPC/GF-5 sensors recently launched by the Chinese Space Agency. Instruments such as the 3MI/MetOp-SG, MAIA, SpexOne and HARP2 on PACE, POSP, SMAC, PCF, DPC–Lidar, ScanPol and MSIP/Aerosol-UA, MAP/Copernicus CO2 Monitoring, etc. are planned to be launched by different space agencies in the coming decade. The concepts of these future instruments, their technical designs, and the accompanying algorithm development have been tested intensively and analyzed using diverse airborne prototypes. Certain polarimetric capabilities have also been implemented in such satellite sensors as GOME-2/MetOp and SGLI/GCOM-C.

Aerosols↗

Synchrophasors-based Master State Awareness Estimator for Cybersecurity in Power Grid: Testbed Implementation & Field Demonstration

The integration of distributed energy resources(DERs) and expansion of complex network in the distribution grid requires an advanced distributed state estimator to monitor the grid health at micro-level. The distribution state estimator will improve the situational awareness and resiliency of distributed power system. This paper proposes a synchrophasors-based master state awareness (MSA) estimator to enhance the cybersecurity in distribution grid by providing a real-time estimation of system operating states to control center operators. In this paper, the proposed MSA estimator utilizes only phasor measurements, bus magnitudes and angles, from phasor measurement units (PMUs),deployed in local substations, to estimate the system states and also detects data integrity attacks, such as load tripping attack that disconnects the load. To validate the proof of concept, we implement the proposed methodology in cyber-physical testbed environment at the Idaho National Laboratory (INL) Electric Grid Security Testbed. Further, to address the “valley of death” and support technology commercialization, field demonstration is also performed at the Critical Infrastructure Test Range Complex(CITRC) at the INL. Our experimental results reveal a promising performance in detecting load tripping attack and providing an accurate situational awareness through an alert visualization dashboard in real-time

42 ENGINEERING↗

Smart Meter Pinging and Reading Through AMI Two-Way Communication Networks to Monitor Grid Edge Devices and DERs

Today’s power distribution system is changing to a power-electronics-enabled distribution system, especially with the increasing penetration of distributed energy resources (DERs). To monitor and manage those electronic devices and DERs at the grid edge, the advanced metering infrastructure (AMI) with two-way communications presents great potential. At present, extensive research explores the upstream communication from smart meters to electric utilities (e.g., meter reading) but few examine the downstream communication from the utilities to smart meters (e.g., meter pinging). This article discusses the AMI two-way communication and its recent industrial practice in the U.S., especially for applying the smart meter pinging functionality to monitor grid-edge devices and DERs. This paper then develops the two-way communication model and the network calculus method to quantify the impact of the two-way communication on the AMI network. In the end, the proposed method is validated with ns-3 simulation using the modified 13-node test feeder and real-world feeder systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗