Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distributed frequency regulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Pulse-width-modulated attenuator for AGC

Automatic-gain-control (AGC) circuit regulates gain of intermediate-frequency and radio-frequency signals over wide dynamic range with high linearity and very low phase shift. Device has potential uses in radio and television receivers, signal distribution systems, and test and measurement instruments.

Macconnell, J. W.↗

Optimizing DER Participation in Inertial and Primary-Frequency Response

This paper develops an approach to enable the optimal participation of distributed energy resources (DERs) in inertial and primary-frequency response alongside conventional synchronous generators. Leveraging a reduced-order model description of frequency dynamics, DERs' synthetic inertias and droop coefficients are designed to meet time-domain performance objectives of frequency overshoot and steady-state regulation. Furthermore, an optimization-based method centered around classical economic dispatch is developed to ensure that DERs share the power injections for inertial- and primary-frequency response in proportion to their power ratings. Simulations for a modified New England test-case system composed of ten synchronous generators and six instances of the IEEE 37-node test feeder with frequency-responsive DERs validate the design strategy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrical signal transmission and gap junction regulation in a bone cell network: a cable model for an osteon

A cable model is formulated to estimate the spatial distribution of intracellular electric potential and current, from the cement line to the lumen of an osteon, as the frequency of the loading and the conductance of the gap junction are altered. The model predicts that the characteristic diffusion time for the spread of current along the membrane of the osteocytic processes, 0.03 sec, is nearly the same as the predicted pore pressure relaxation time in Zeng et al. (Annals of Biomedical Engineering. 1994) for the draining of the bone fluid into the osteonal canal. This approximate equality of characteristic times causes the cable to behave as a high-pass, low-pass filter cascade with a maximum in the spectral response for the intracellular potential at approximately 30 Hz. This behavior could be related to the experiments of Rubin and McLeod (Osteoporosis, Academic Press, 1996) which show that live bone appears to be selectively responsive to mechanical loading in a specific frequency range (15-30 Hz) for several species.

NASA Discipline Musculoskeletal↗

Grid Connected Functionality

Dataset demonstrating the potential benefits that residential buildings can provide for frequency regulation services in the electric power grid. In a hardware-in-the-loop (HIL) implementation, simulated homes along with a physical laboratory home are coordinated via a grid aggregator, and it is shown that their aggregate response has the potential to follow the regulation signal on a timescale of seconds. Connected (communication-enabled), devices in the National Renewable Energy Laboratory's (NREL's) Energy Systems Integration Facility (ESIF) received demand response (DR) requests from a grid aggregator, and the devices responded accordingly to meet the signal while satisfying user comfort bounds and physical hardware limitations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Microgrid's Role in Enhancing the Security and Flexibility of City Energy Systems

Smart cities depend on flexible and secure energy systems to ensure resilient power for critical infrastructure; however, recent weather-related events and cyberattacks have highlighted weaknesses in our energy systems, with the potential for widespread economic and security impacts. As stated by the Executive Office of the President, "the resilience of the US electric grid is a key part of the nation's defense against severe weather." To address the energy delivery security challenge, microgrids are rising as a viable solution that enhances the flexibility and resilience of the distribution grid and boosts the reliability of the local supply for the end-user. Traditionally, high capital investment has been a barrier to large-scale adoption of microgrid technology. Understanding the flexibility and resilience benefits of microgrids and accounting for the associated value streams can make the microgrid's proposition economically viable. In this chapter, microgrids' utility and their potential to serve as a flexible and resilient resource for the utility grid by providing capabilities such as peak shaving, demand response, and frequency regulation is presented. Moreover, other value streams, such as (1) their ability to island during a disaster and sustain critical loads which makes them a robust resilience solution for end-users, in the event of the utility grid outage and (2) microgrids also provide a flexible platform for integrating distributed energy resources in conjunction with storage and conventional generation technologies, strengthen microgrid's role in reducing the over-arching goal of emission reduction. Given the myriad of benefits associated with microgrids, we present strategies which can be employed for making microgrid itself resilient against physical and cyberthreats by employing hardware, software, and personnel training solutions to operate the microgrid before, during, and after a potential disaster. This chapter, thus, provides a holistic study of the microgrid as a resilience resource, for the utility grid, and a self-contained end-user for the end-user.

cyber-physical system↗

Microgrid Service Restoration Incorporating Unmonitored Automatic Voltage Controllers and Net Metered Loads

Islanded microgrids may experience voltage and frequency instability due to uncontrolled state changes of voltage regulation devices and inaccurate demand forecasts. Uncontrolled state changes can occur if optimal microgrid restoration and dispatch algorithms, used for generating control commands for distributed energy resources, do not incorporate the behavior of automatic controllers of voltage regulation devices. Inaccurate demand forecasts may be encountered since post-outage demand of behind-the-meter net metered (NM) loads can vary significantly from their historical NM profiles. Here, this paper proposes an optimization formulation which allows optimal control of voltage regulators and capacitor banks without remote control and communication capabilities. A generalized demand model for NM loads is proposed which incorporates the cold load pickup phenomenon and their time varying post-outage demand in accordance with the IEEE 1547 standard. The time dependent optimal control formulation and the NM demand model are integrated in a sequential microgrid restoration algorithm by linearization of the involved logic propositions. A detailed case study on the unbalanced IEEE 123-node test system in OpenDSS validates the effectiveness of the proposed approach.

30 DIRECT ENERGY CONVERSION↗

Controlling Wind Turbines for Secondary Frequency Regulation: An Analysis of AGC Capabilities Under New Performance Based Compensation Policy: Preprint

As wind energy becomes a larger portion of the world's energy portfolio there has been an increased interest for wind turbines to control their active power output to provide ancillary services which support grid reliability. One of these ancillary services is the provision of frequency regulation, also referred to as secondary frequency control or automatic generation control (AGC), which is often procured through markets which recently adopted performance-based compensation. A wind turbine with a control system developed to provide active power ancillary services can be used to provide frequency regulation services. Simulations have been performed to determine the AGC tracking performance at various power schedule set-points, participation levels, and wind conditions. The performance metrics used in this study are based on those used by several system operators in the US. Another metric that is analyzed is the damage equivalent loads (DELs) on turbine structural components, though the impacts on the turbine electrical components are not considered. The results of these single-turbine simulations show that high performance scores can be achieved when there is sufficient wind resource available. The capability of a wind turbine to rapidly and accurately follow power commands allows for high performance even when tracking rapidly changing AGC signals. As the turbine de-rates to meet decreased power schedule set-points there is a reduction in the DELs, and the participation in frequency regulation has a negligible impact on these loads.

17 WIND ENERGY↗

Controlling Wind Turbines for Secondary Frequency Regulation: An Analysis of AGC Capabilities Under New Performance Based Compensation Policy

As wind energy becomes a larger portion of the world's energy portfolio there has been an increased interest for wind turbines to control their active power output to provide ancillary services which support grid reliability. One of these ancillary services is the provision of frequency regulation, also referred to as secondary frequency control or automatic generation control (AGC), which is often procured through markets which recently adopted performance-based compensation. A wind turbine with a control system developed to provide active power ancillary services can be used to provide frequency regulation services. Simulations have been performed to determine the AGC tracking performance at various power schedule set-points, participation levels, and wind conditions. The performance metrics used in this study are based on those used by several system operators in the US. Another metric that is analyzed is the damage equivalent loads (DELs) on turbine structural components, though the impacts on the turbine electrical components are not considered. The results of these single-turbine simulations show that high performance scores can be achieved when there are insufficient wind resources available. The capability of a wind turbine to rapidly and accurately follow power commands allows for high performance even when tracking rapidly changing AGC signals. As the turbine de-rates to meet decreased power schedule set-points there is a reduction in the DELs, and the participation in frequency regulation has a negligible impact on these loads.

17 WIND ENERGY↗

Control Strategies for Distributed Energy Resources to Maximize the Use of Wind Power in Rural Microgrids

The focus of this paper is to design control strategies for distributed energy resources (DERs) to maximize the use of wind power in a rural microgrid. In such a system, it may be economical to harness wind power to reduce the consumption of fossil fuels for electricity production. In this work, we develop control strategies for DERs, including diesel generators, energy storage and demand response, to achieve high penetration of wind energy in a rural microgrid. Combinations of centralized (direct control) and decentralized (autonomous response) control strategies are investigated. Detailed dynamic models for a rural microgrid are built to conduct simulations. The system response to large disturbances and frequency regulation are tested. It is shown that optimal control coordination of DERs can be achieved to maintain system frequency while maximizing wind power usage and reducing the wear and tear on fossil fueled generators.

17 WIND ENERGY↗

Beta Test Plan for Advanced Inverters Interconnecting Distributed Resources with Electric Power Systems

This document provides a preliminary (beta) test plan for grid interconnection systems of advanced inverter-based DERs. It follows the format and methodology/approach established by IEEE Std 1547.1, while incorporating: 1. Upgraded tests for responses to abnormal voltage and frequency, and also including ride-through. 2. A newly developed test for voltage regulation, including dynamic response testing. 3. Modified tests for unintentional islanding, open phase, and harmonics to include testing with the advanced voltage and frequency response functions enabled. Two advanced inverters, one single-phase and one three-phase, were tested under the beta test plan. These tests confirmed the importance of including tests for inverter dynamic response, which varies widely from one inverter to the next.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Short-Term Forecasting of Inertial Response from a Wind Power Plant

The total inertia stored in all rotating masses (synchronous generators, induction motors, etc.) connected to a power system grid is an essential force that keeps the system stable after disturbances. Power systems have been experiencing reduced inertia during the past few decades [1]. This trend will continue as the level of renewable generation (e.g., wind and solar) increases. Wind power plants (WPPs) and other renewable power plants with power electronic interfaces are capable of delivering frequency response (both droop and/or inertial response) by a control action; thus, the reduction in available online inertia can be compensated by designing the plant control to include frequency response. The source of energy to be delivered as inertial response is determined by the type of generation (wind, photovoltaic, concentrating solar power, etc.) and the control strategy chosen. The importance of providing ancillary services to ensure frequency control within a power system is evidenced from many recent publications with different perspectives (manufacturer, system operator, regulator, etc.) [2]-[6]. This paper is intended to provide operators with a method for the real-time assessment of the available inertia of a WPP. This is critical to managing power system stability and the reserve margin. In many states, modern WPPs are required to provide ancillary services (e.g., frequency regulation via governor response and inertial response) to the grid. This paper describes the method of estimating the available inertia and the profile of the forecasted response from a WPP.

17 WIND ENERGY↗

Power Hardware-in-the-Loop Testing of Distribution Solid State Transformers

Savannah River National Laboratory and Resilient Power Systems have developed a utility grade solid state transformer and are planning on deploying it for testing in January 2018. The solid state transformer is the next generation solution to implementation of distributed energy resources such as solar and batteries. They can directly connect the solar and battery systems to DC ports and rout power between these DC ports and load ports. The solid state transformer can revolutionize current grid modernization initiatives by supplying grid support and building support services at the edge of the grid. These services consist of volt-VAR optimization, power factor correction, voltage regulation, frequency regulation, fault current support, demand side management, DC bus for AC/DC capable houses, and power routing between multiple ports for transactive control. For this fiscal year a test plan for testing the SST capabilities was develop. Along with the FPGA controls for the SST output ports. These controls will allow for any waveform to be produced by each port of the SST. Finally, a hybrid distribution SST was tested at the eGRID resulting in medium voltage testing experience for SRNL engineering team. DOE is currently engaged, through the Building Technology Office and Infrastructure Security and Energy Restoration in future work building from this project.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Secondary Frequency Regulation from Variable Generation through Uncertainty Decomposition: An Economic and Reliability Perspective

The rapid integration of variable generation (VG), such as photovoltaics (PV), necessitates an increase in the secondary frequency regulation (SFR) to handle the system intra-dispatch interval imbalance because of VG's variation. Although PV has the control capability to provide SFR, the main challenge is in guaranteeing the delivery of PV's energy and SFRs capacities in the automatic generation control (AGC) within each dispatch interval considering its uncertainty. This paper proposes a deliverable VG SFR provision model with endogenous VG's power uncertainty decomposition. First, the uncertainty of VG is decomposed using distributionally robust chance constraints through which the deliverable SFR provision is guaranteed. Next, the intra-interval frequency response of PV's SFR is validated with a user defined AGC model including the PV power plant. Finally, the economic benefits and the reliability improvements such as the frequency deviation reduction with PV providing SFRcan be integrated and evaluated. The proposed model is tested in a modified 18-bus system and in the Western Electricity Coordinating Council test system. Results demonstrate that with the deliverable SFR from PV, the system cost and the frequency reliability can be improved simultaneously. PV's SFR performance can be guaranteed with the proposed model.

14 SOLAR ENERGY↗

Adaptive Gain-based Stable Power Smoothing of a DFIG

In a power system that has a high wind penetration, the output power fluctuation of a large-scale wind turbine generator (WTG) caused by the varying wind speed increases the maximum frequency deviation, which is an important metric to assess the quality of electricity, because of the reduced system inertia. This paper proposes a stable power-smoothing scheme of a doubly-fed induction generator (DFIG) that can suppress the maximum frequency deviation, particularly for a power system with a high wind penetration. To do this, the proposed scheme employs an additional control loop relying on the system frequency deviation that operates in combination with the maximum power point tracking control loop. To improve the power-smoothing capability while guaranteeing the stable operation of a DFIG, the gain of the additional loop is modified with the rotor speed and frequency deviation. The gain is set to be high if the rotor speed and/or frequency deviation is large. Here, the simulation results based on the IEEE 14-bus system demonstrate that the proposed scheme significantly lessens the output power fluctuation of a WTG under various scenarios by modifying the gain with the rotor speed and frequency deviation, and thereby it can regulate the frequency deviation within a narrow range.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Primary Frequency Control Using Motor Drives for Short Term Grid Disturbances

Industrial motor systems make up a quarter of all electric sales in the United States. Variable speed drives (VSDs) can provide energy efficiency savings to the customer by regulating motor speed based on specific and varying needs. In addition to the benefits provided to the customer, VSDs can provide support to the grid through ancillary services. The Center for Ultra-Wide-Area Resilient Electric Energy Transmission Networks (CURENT) developed a power electronics converter-based grid emulator to allow testing of various power system architectures and demonstration of key technologies in monitoring, control, actuation, and visualization. This paper proposes using an active front-end VSD's connected motor load to provide frequency regulation to a large scale power grid. Each part of the emulator is described including motor and power electronics model and control. The proposed frequency regulation is implemented in VSDs and modeled in both a transmission system in EMTDC/PSCAD and verified on CURENT's hardware testbed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Two-Stage Series-Resonant Inverter

Two-stage inverter includes variable-frequency, voltage-regulating first stage and fixed-frequency second stage. Lightweight circuit provides regulated power and is invulnerable to output short circuits. Does not require large capacitor across ac bus, like parallel resonant designs. Particularly suitable for use in ac-power-distribution system of aircraft.

Stuart, Thomas A.↗

Grid-Level Application of Electrical Energy Storage: Example Use Cases in the United States and China

Electrical energy storage (EES) systems are expected to play an increasing role in helping the United States and China-the world's largest economies with the two largest power systems-meet the challenges of integrating more variable renewable resources and enhancing the reliability of power systems by improving the operating capabilities of the electric grid. EES systems are becoming integral components of a resilient and efficient grid through a diverse set of applications that include energy management, load shifting, frequency regulation, grid stabilization, and voltage support.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimization of a Virtual Power Plant to Provide Frequency Support.

Increasing the penetration of distributed renewable sources, including photovoltaic (PV) sources, poses technical challenges for grid management. The grid has been optimized over decades to rely upon large centralized power plants with well-established feedback controls, but now non-dispatchable, renewable sources are displacing these controllable generators. This one-year study was funded by the Department of Energy (DOE) SunShot program and is intended to better utilize those variable resources by providing electric utilities with the tools to implement frequency regulation and primary frequency reserves using aggregated renewable resources, known as a virtual power plant. The goal is to eventually enable the integration of 100s of Gigawatts into US power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗