Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distributed fault detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

155 records · Page 9

AI-Based Protective Relays for Electric Grid Resiliency

The protection systems (circuit breakers, relays, reclosers, and fuses) of the electric grid are the primary component responding to resilience events, ranging from common storms to extreme events. The protective equipment must detect and operate very quickly, generally <0.25 seconds, to remove faults in the system before the system goes unstable or additional equipment is damaged. The burden on protection systems is increasing as the complexity of the grid increases; renewable energy resources, particularly inverter-based resources (IBR) and increasing electrification all contribute to a more complex grid landscape for protection devices. In addition, there are increasing threats from natural disasters, aging infrastructure, and manmade attacks that can cause faults and disturbances in the electric grid. The challenge for the application of AI into power system protection is that events are rare and unpredictable. In order to improve the resiliency of the electric grid, AI has to be able to learn from very little data. During an extreme disaster, it may not be important that the perfect, most optimal action is taken, but AI must be guaranteed to always respond by moving the grid toward a more stable state during unseen events.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber risk assessment and investment optimization using game theory and ML-based anomaly detection and mitigation for wide-area control in smart grids

The electric power grid is increasingly becoming susceptible to cyber attacks that exploit vulnerabilities in the smart grid control, information, and physical layers. Successful cyber attacks can have catastrophic impacts on the social and economic well-being of any nation all over the globe. It has, thus, become imperative to secure the smart grid against such adversarial actions to ensure stable, secure, and reliable operation of the grid. The existing research and industry practices prove to be inadequate in terms of providing pragmatic and effective defense methodologies and measures for long-term cybersecurity planning and real-time cybersecurity for grid operation. For example, existing works lack models that incorporate uncertain behavior of cyber-attackers and pragmatic defense measures for cyber risk assessment and cybersecurity investment optimization which often provide unreliable and strictly qualitative solutions to these problems. At the same time, with the growing number of cyber incidents in the grid, there still exists a need to develop attack-resilient algorithms for wide-area monitoring, protection, and control (WAMPAC) applications like the wide-area voltage control systems (WAVCS) for Flexible AC Transmissions Systems (FACTS) that lack in scalable and feasible solutions from the cybersecurity perspective. This dissertation proposes novel models and methodologies for: (1) Cybersecurity planning, and (2) Cybersecurity for system operation. The cybersecurity planning is achieved through cyber risk assessment and cybersecurity resource investment optimization for long-term cybersecurity of the grid using game theory and attack-defense trees. Cybersecurity for system operation consists of development of cyber anomaly detection and mitigation algorithms for flexible AC transmission system (FACTS) controller-based wide-area voltage control systems (WAVCS) using machine learning (ML), and software defined networking-based moving target defense network routing for achieving real-time cyber-physical security for grid operations. This is followed by hardware-in-the-loop (HIL) implementation and evaluation of these attack prevention, detection, and mitigation algorithms and methodologies showcasing their feasibility in a close to real-world environment. For cybersecurity planning, a novel approach involving a combination of game theory and attack defense trees (ADT) for optimal cybersecurity resource allocation in the smart grid is proposed. This methodology involves modeling of the cyber-physical smart grid substations as ADTs, defining attacker costs, defense costs, and attack probabilities for attack access points. Using game theoretical formulation, optimal defense strategies for the defender of the system to invest cybersecurity resources in the grid are obtained. Additionally, a game-theoretic framework is developed for quantitative cyber-physical risk assessment of the grid under a dynamically changing cyber threat space and uncertain behavior of cyber attackers which is further used to optimize investments in the smart grid's cybersecurity resources. The attacker, defender, and the smart grid system are modeled while incorporating attacker-stochasticity and federal guidelines for smart grid cybersecurity. This allows quantification of threat, vulnerabilities, and attack impact of the grid for quantitative risk assessment. The defender's budget to invest in the security resources in the grid is optimized based on the strategies leading to minimum system risk. The evaluation of the proposed solutions highlight the feasibility for practical implementation of these methodologies and algorithms in the smart grid, while taking the federal requirements and guidelines for smart grid security into consideration. For achieving cybersecurity for system operation, attack prevention, detection, and mitigation algorithms and methodologies are developed specifically for FACTS-based WAVCS. Anomaly detection and mitigation in the WAVCS are achieved using algorithms based on machine learning which involves offline training and testing of ML models with CPS datasets incorporating physics-based features that allow accurate distinction between system faults and cyber attacks. For attack prevention, a methodology based on software defined network (SDN)-based moving target defense (MTD) network routing is proposed that enables prevention of Denial of Service (DoS) type attacks on the smart grid communication system. Subsequently, these methodologies and algorithms are implemented and evaluated on an HIL testbed that allows for real-time attack prevention, detection, and mitigation of emulated cyber attacks on the WAVCS in a close to real-world environment. The results show highly accurate and efficient performance of the implemented algorithms and methodologies with the smart grid system operating within the NERC's system operation limits even in the presence of DoS and data integrity cyber attacks. This work opens up future research opportunities in other directions such as (1) Expanding cybersecurity planning methodologies to real-time cyber contingency analysis with different game formulations; and (2) Applying the cybersecurity for system operation algorithms to broader categories of wide-area control applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

T-Type Modular DC Circuit Breaker (T-Breaker) for Future DC Networks

The developed T-Type Modular DC Circuit Breaker (T-Breaker) technology offers an all-in-one solution to challenges in DC networks. This includes swift fault detection and protection, power transient stability, and power quality improvement, achieved through the utilization of wide bandgap (WBG) power semiconductors and energy storage devices. The T-Breaker not only facilitates rapid fault current detection and interruption but also implements fault current limiting through active insertion of storage devices or by operating WBG devices in the saturation region. Additionally, with the assistance of energy storage devices, potential overvoltage issues on power devices induced by control signal misalignment can be mitigated. The T-Breaker can be regulated to perform shunt current injection/absorption using the vertical arm and series voltage insertion via the horizontal arm, thereby enhancing DC system stability during voltage or load power fluctuation transients. The OSU team and Raytheon team actively worked together on designing, fabricating, assembling, and testing of two T-Breaker prototypes. The first prototype is rated at 1 kV, 500 A with half-bridge (unipolar) structure to validate the T-Breaker concept. The second prototype is rated at 20 kV, 50 A with full-bridge (bipolar) topology which can reach an efficiency of 99.977%, realize a power density of 60.2 MW/m3, and eliminate the 500-A fault current with a fault response time of around 20 µs. The prototypes show great feasibility of adopting this technology in multiple applications including electrified aircraft, super charging stations, data centers, etc.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cybersecurity for Distance Relay Protection

This project is a DOE follow-up effort on the CREDC workshop held on September 13, 2018 in Cambridge, MA to discuss cybersecurity of distance relays, which considered the benefits, vulnerabilities and risk mitigations for the use of communication systems in power system protection. The objectives of this project are to define the taxonomy of relay protection and associated communications; define use cases describing approaches to reduce the cyber-attack surface on those protective relays; and evaluate the loss of operational functional capability from changes to communication coverage. Mitigating controls will also be evaluated to understand if there are other approaches to reduce attack surfaces while maintaining communications or partial communications. Distance relays are used to protect transmission lines of approximately 10 to 300 miles in length, by detecting short circuits (i.e., faults) on the lines and then tripping circuit breakers in the substation. Such protection systems are a subset of the power system and they incorporate sensing, logic and communication functions. Protection system exposure to cyberattack could be drastically limited by disconnecting relays from all vulnerable communication systems, but this may adversely impact overall power system performance in the absence of cyberattack. This project began with a use case analysis of protection systems with communications, as summarized in this report. It continued with modeling, testing and evaluation in a miniature power system (MPS), located in the Western Area Power Administration (WAPA) Electric Power Training Center (EPTC). The project also incorporated feedback from two industry meetings held in February and September 2019. The suggested next steps account for and complement the work already underway with DOE/CESER funding: 1. Study the performance of LCD and PC vs. PUTT, which is less reliant on communication system performance and GPS timing references. The PUTT scheme could prove to be more resilient to cyberattack or communications-related disruption. It could also be more tolerant of message re-routing with SDN/SDR communication systems. On the other hand, it will be more vulnerable to false tripping during dynamic events or to loss of the voltage signal. The optimum choice of scheme may depend on the specific power system and risk assessment. This study could provide a new template for evaluation based on business functions. 2. Research and develop new methods to detect and monitor distributed physical attacks, possibly using drones, video sensors, thermal sensors, machine learning and other advanced techniques. This will help mitigate the impact of cyberattack on the protection system, and will also help mitigate the impact of wild fires. 3. Implement a scalable PKI for use in electric utility protection systems. This will encourage widespread adoption of secure authentication methods that are already available, but not widely used at present. This will help secure engineering access to the relays. 4. Investigate the use of SDN in combination with SDR to achieve better cybersecurity and electromagnetic security of the network, incorporating path variability. This would help secure both engineering access and peer-to-peer GOOSE messaging. 5. Perform additional testing, with operator evaluation of “red button” scenarios, PUTT vs. LCD, relay mis-operations, and other cyberattacks in the EPTC. This is an important advantage of testing in the EPTC rather than by computer simulation or even hardware-in-the-loop simulation; the EPTC is already dedicated to managing the situational awareness, operator response times and other human impacts. One of the project objectives was to settle on a common nomenclature for this problem space. We have concluded that the OSI layer model, supplemented by ANSI device numbers and other IEEE standards, is already well-accepted by the industry. The IEEE PSRC knowledge base provides a great deal of public information

24 POWER TRANSMISSION AND DISTRIBUTION↗

Monitoring of Liquid Metal Reactor Heater Zones with Recurrent Neural Network Learning of Temperature Time Series

Advanced high-temperature fluid reactors (ARs), such as sodium fast reactors (SFRs) and molten salt cooled reactors (MSCRs) utilize high-temperature fluids at ambient pressure. To melt the fluid during reactor startup and prevent fluid freezing during cooldown, the thermal–hydraulic systems of such ARs include heater zones consisting of specific heaters with controllers, temperature sensors, and thermal insulation. The failure of heater zones due to insulation material degradation or improper installation, resulting in parasitic heat losses, can lead to fluid freezing. The detection of faults using a heat-transfer model is difficult because of a lack of knowledge of the experimental details. Data-driven machine learning of heater zone temperature time series offers a viable alternative. In this study, we benchmarked the performance of recurrent neural networks (RNNs) in an analysis of heat-up transient temperature time series of heater zones installed on a liquid sodium vessel. The RNN models include long short-term memory (LSTM) and gated recurrent unit (GRU) networks, as well as their bi-directional variants, BiLSTM and BiGRU. Anomalous temperature points were designated using a percentile-based threshold applied to residual fluctuations in the detrended temperature time series. Additionally, the impact of the exponentially weighted moving average (EWMA) method on detection accuracy was examined. The RNN models’ performance was assessed using precision, recall, and F 1 score metrics. Results demonstrated that RNN models effectively detect anomalies in temperature time series with the best models for each heater zone achieving F 1 scores of over 93%. To explain the variations in RNN model performance across different heater zones, we used Kullback–Leibler (KL) divergence to quantify the relative entropy between training and testing data, and the Detrended Fluctuation Analysis (DFA) to assess long-range temporal correlations. For datasets with strong long-range correlations and minimal relative entropy between training and testing data, GRU is the best-performing model. When the data exhibits weaker long-term correlations and a significant relative entropy between training and testing distributions, BiGRU shows the best performance. For the data sets with intermediate values of both KL divergence and DFA, the best performance is obtained with LSTM and BiLSTM, respectively.

gated recurrent unit↗

IS BLOCKCHAIN A SUITABLE TECHNOLOGY FOR ENSURING THE INTEGRITY OF DATA SHARED BY LIGHTING AND OTHER BUILDING SYSTEMS?

Increasing amounts of data are available from lighting and other building systems. In commercial buildings, these data can be used to improve system and energy performance, detect and diagnose faults, and facilitate maintenance. Building data are not only of interest to owners and operators of the building systems, however. Owners and operators of similar buildings, manufacturers of building systems, utilities, and city agencies also have interesting use cases. Energy data can, for example, be used to verify the performance of energy-conservation measures, issue renewableenergy certificates, and financially settle grid services. Increased data sharing, however, significantly expands the cyber-attack surface, creating new challenges. In this work, blockchain is explored as an option for ensuring the integrity of data that are shared by lighting and other building systems. Blockchain fundamentals and variants are briefly reviewed, and value propositions relevant to building systems are discussed. A recently developed blockchain applicability framework (BAF) that builds upon and addresses the limitations of previous applicability models is also briefly reviewed. The BAF is used to assess the suitability of blockchain over other technologies or approaches for building-data applications, using emerging connected lighting systems as an example use case.

blockchain, connected lighting system, data integr↗

Relocating microseismicity from downhole monitoring of the Decatur CCS site using a modified double-difference algorithm

SUMMARY The injection of CO2 at the Decatur carbon capture and storage site has generated significant microseismic activity, which occurs in distinct spatial clusters up to approximately 2.2 km from the primary injection well. Accurate and precise event locations are vital for the characterization of the microseismicity to help understand the reservoir response to the CO2 injection, whilst enabling the identification of minor faults and fractures below the resolution of conventional active seismic imaging. However, microseismic monitoring of fluid injection sites, such as Decatur, is often performed using a network of borehole sensors often from a single well. While these downhole sensors have excellent detection capabilities, their poor azimuthal coverage limits the ability to precisely determine event locations. We have developed a modified double-difference relocation algorithm suitable for both 1-D and 3-D velocity models, and which incorporates differential back azimuth observations to allow the benefits of the original double-difference algorithm to be applicable to a downhole microseismic monitoring setting. Applying the modified double-difference algorithm to the microseismicity at Decatur, we have successfully relocated 4293 events. The relocation included over 59 million observations for 757 285 event pairs, split across seven geographic regions. Despite the majority of observations being recorded in only two boreholes, with an almost identical azimuthal coverage, the results have shown to be reliable with significantly reduced residuals and low uncertainties associated with the final locations. We have analysed the residuals in terms of their association with each geographic region, data type, station and individual events, to fully appreciate their influence in the inversion and the fit of the data to the final set of event locations. For each region, the relocated seismicity has become less diffuse with improved clustering, and with newly visible linear features often orientated in a NE–SW direction. These results show the potential improvements that can be made to microseismic event locations recorded by a borehole network with a limited and variable azimuthal distribution.

58 GEOSCIENCES↗

Mitigating Data Center Impact on Grid Stability: A Coordinated Control Strategy Using Verrus StabiliGrid Architecture

Large data centers, which now represent a significant and growing share of the total U.S. grid load, can inadvertently destabilize the electrical grid when they disconnect simultaneously during brief voltage disturbances. The July 10, 2024, Eastern Interconnection incident, in which a sub-100-millisecond transmission fault triggered the cascading loss of approximately 1,500 MW of data center load, illustrates this vulnerability. While commercial battery energy storage systems (BESS) deployed in data centers provide device-level fault ride-through per IEEE 1547, they lack coordination with facility protection logic and uninterruptible power supplies (UPS), limiting their effectiveness as grid-stabilizing assets. This report presents the Verrus StabiliGrid architecture, a coordinated control framework that integrates BESS, UPS, and point-of-interconnection (POI) protection settings to enable data centers to ride through both undervoltage and overvoltage grid contingencies without disconnecting. The four-step strategy encompasses: (1) high-resolution power quality monitoring to detect the grid state during events such as undervoltage, overvoltage, underfrequency, and overfrequency; (2) POI protection settings that allow for extended ride-through and grid-connected operation during grid contingencies; (3) grid state-driven autonomous dispatch of assets to improve grid resilience by reducing power draw during undervoltage or absorbing more power during overvoltage events; and (4) coordinated post-recovery dispatch of data center assets to restore firm load to pre-contingency levels. Validated through controller-hardware-in-the-loop (C-HIL) simulations at the National Laboratory of the Rockies, results show grid import restoration to pre-fault levels within 100 milliseconds of voltage recovery. This work advances the ability of data centers to transition from passive, disturbance-sensitive loads to active participants in grid stability, a capability increasingly required by emerging NERC and ERCOT regulatory frameworks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Seismic Characterization of the Blue Mountain Geothermal Field

Subsurface characterization is crucial for geothermal energy exploration and production. Yet hydrothermal reservoirs usually reside in highly fractured and faulted zones where accurate characterization is very challenging because of low signal-to-noise ratios of land seismic data and lack of coherent reflection signals. We perform an active-source seismic characterization for the Blue Mountain geothermal field in Nevada using active seismic data to reveal the elastic medium property complexity and fault distribution at this field. We first employ an unsupervised machine learning method to attenuate groundroll and near-surface guided-wave noise and enhance coherent reflection and scattering signals from noisy seismic data. We then build a smooth initial P-wave velocity model based on an existing magnetotellurics survey result, and use 3D first-arrival traveltime tomography to refine the initial velocity model. We then derive a set of elastic wave velocities and anisotropic parameters using elastic full-waveform inversion, and obtain PP and PS images using elastic reverse-time migration. We identify major faults by analyzing the variations of seismic velocities and anisotropy parameters, and reveal mid- to small-scale faults by applying a supervised machine learning method to the seismic migration images. Our characterization reveals complex velocity heterogeneities and anisotropies, as well as faults, with a high spatial resolution. These results can provide valuable information for optimal placement of future injection and production wells to increase geothermal energy production at the Blue Mountain geothermal power plant.

58 GEOSCIENCES↗

Enabling Realistic Communications Evaluations for ADMS

Increasing penetration levels of inverter-based distributed energy resources (DERs) in distribution systems are creating challenges in system operation. Currently, wired or proprietary wireless communications are used by advanced distribution management systems (ADMS) to detect the state of the system and control the DERs for optimal operation. Wireless communications are an alternative solution that can enable connectivity between the dispersed assets used in distribution system applications. As demand for the seamless integration of distributed energy resources (DERs) continues to increase, proper networking and communications systems are becoming important to support the DER infrastructure. This report summarizes validation of a private wireless LTE network in a laboratory environment. The purpose of this work is to 1) demonstrate the effectiveness of private wireless LTE communication for grid applications and 2) provide a means of evaluating latency and overall performance of wireless communication in grid applications. First, private wireless LTE communication was validated in a direct transfer trip relaying scenario as an example of one-way communications using grid equipment. This study provided a baseline understanding of the variation in latency for seven different kinds of wireless scenarios shown in Figure A below. As expected, weak (attenuated) wireless signal-based communication yielded the widest ranges in latency. When higher priority was set for the trip signal communication, this resulted in lower latency in communication timing. In the final phase of this project, the private wireless LTE network was validated using two-way communications in an advanced distribution management system (ADMS) testbed which was developed in the ESIF at NREL. The purpose of this was to study the impact of wireless communication on grid performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗