Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “disconnection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Independent Orbiter Assessment (IOA): Analysis of the purge, vent and drain subsystem

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results corresponding to the Orbiter PV and D (Purge, Vent and Drain) Subsystem hardware. The PV and D Subsystem controls the environment of unpressurized compartments and window cavities, senses hazardous gases, and purges Orbiter/ET Disconnect. The subsystem is divided into six systems: Purge System (controls the environment of unpressurized structural compartments); Vent System (controls the pressure of unpressurized compartments); Drain System (removes water from unpressurized compartments); Hazardous Gas Detection System (HGDS) (monitors hazardous gas concentrations); Window Cavity Conditioning System (WCCS) (maintains clear windows and provides pressure control of the window cavities); and External Tank/Orbiter Disconnect Purge System (prevents cryo-pumping/icing of disconnect hardware). Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode. Four of the sixty-two failure modes analyzed were determined as single failures which could result in the loss of crew or vehicle. A possible loss of mission could result if any of twelve single failures occurred. Two of the criticality 1/1 failures are in the Window Cavity Conditioning System (WCCS) outer window cavity, where leakage and/or restricted flow will cause failure to depressurize/repressurize the window cavity. Two criticality 1/1 failures represent leakage and/or restricted flow in the Orbiter/ET disconnect purge network which prevent cryopumping/icing of disconnect hardware. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode.

Bynum, M. C., III↗

Comparison of the plasma tails of four comets: P/Halley, Okazaki-Levy-Rudenko, Austin, and Levy

Photographic and charge coupled device (CCD) plasma tail observations are compared for four comets: P/Halley (22 nights in 1985/1986), Okazaki-Levy-Rudenko 1989 XIX (1989 December 2), Austin 1990 V (nine nights in 1990), and Levy 1990 XX (two nights in 1991). We present a discussion of several image-processing techniques used to enhance the visibility of the plasma tail features in order to measure velocities, accelerations, and position angles. The data are used to assess the validity of various physical mechanisms proposed to explain plasma tail phenomena. Seven disconnection events were observed in the comet P/Halley data, two in the Austin data, and none for the other comets. Analysis of these data suggests that while the crossing of the solar neutral sheet (the sector boundary) is a prominent factor in the production of a disconnection event, it is likely that several mechanisms are at work. A sector boundary crossing has been ruled out as the cause of either the 1986 April 26 P/Halley disconnection or the 1990 May 5/6 Austin disconnection. The motions of the disconnection events, knots, and condensations in the tails were seen to increase from 30-60 km/s near the nucleus (within 10(exp 6) km) to 80-100 km/s at 10(exp 7) km, consistent with either bulk motion or Alfven waves. Distinguishing between the two cases is not possible with these data. It was found that although the tail ray rotation rate slows as the ray approaches the tail axis, it is not a good indicator of the solar wind speed. Historical plasma tail data are also used to look for clues as to why some comets form well-developed plasma tails and others do not.

Farnham, Tony L.↗

Structures far from the head of comet Kohoutek. II - A discussion of the Swan Cloud of January 11 and of the general morphology of cometary plasma tails

Photographs show that the 'Swan Cloud' observed in comet Kohoutek on January 11, 1974 was an advanced stage of a plasma tail disconnection event, of which the rejected tail appeared to decelerate as it receded from the head. The event commenced with the development of strong tail ray activity followed by the actual tail disconnection, the merging of the disconnected tail with the new tail to form the Swan and the formation of arcade loops in the space between closing tail rays. The observed morphological sequence is easily understood in the sector boundary model (Niedner et al., 1978), and the arcade loops are proposed to be reconnected flux tubes between oppositely polarized tail rays in the incipient new tail which followed the disconnection

Niedner, M. B., Jr.↗

Stringy ER = EPR

The ER = EPR correspondence relates a superposition of entangled, disconnected spacetimes to a connected spacetime with an Einstein-Rosen bridge. We construct examples in which both sides may be described by weakly-coupled string theory. The relation between them is given by a Lorentzian continuation of the FZZ duality of the two-dimensional Euclidean black hole CFT in one example, and in another example by continuation of a similar duality that we propose for the asymptotic Euclidean AdS 3 black hole. This gives a microscopic understanding of ER = EPR: one has a worldsheet duality between string theory in a connected, eternal black hole, and in a superposition of disconnected geometries in an entangled state. The disconnected description includes a condensate of entangled folded strings emanating from a strong-coupling region in place of a bifurcation point. Our construction relies on a Lorentzian interpretation of Euclidean time winding operators via angular quantization, as well as some lesser known worldsheet string theories, such as perturbation theory around a thermofield-double state, which we define using Schwinger-Keldysh contours in target space.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Use of non-contact voltmeter to quantify potential induced degradation in CdTe modules

Potential induced degradation (PID) is a significant reliability issue for photovoltaic modules in the field. Conventionally, to detect the PID-affected modules, all the modules in a string are individually disconnected and measured using I-V (current–voltage) tracers. It is extremely time-consuming, expensive and unsafe (if the module connectors are field aged) approach. In our approach, we aim detecting the PID-affected modules quickly, inexpensively and safely without disconnecting individual modules in the string. In this study, contactless electrostatic voltmeter’s (ESV) strength was explored to detect the PID-affected cadmium telluride (CdTe) modules in a string. These contactless measurements on high-voltage PV strings could make this technique unique and preferable to detect PID-affected modules in a string compared to the I-V curve method. In this work, a CdTe module was stressed for PID using the Aluminum (Al) foil method in a walk-in environmental chamber, which resulted in a reduction of module's peak current (I max ), peak voltage (Vmax), and fill factor (FF), and hence power (Pmax). Outdoor light I-V, EL, and ESV measurements were performed pre- and post-PID to determine the effectiveness of the non-contact ESV technique. Further, the ESV technique successfully detected the change in V max , and hence Pmax, compared to the pre-and post-PID conditions. A difference of less than 2% was observed in the results of the non-contact and non-interruptive method compared to the conventionally used interruptive voltmeter or I-V tracer method. This technique and the test results demonstrate a significant promise to identify poor-performing modules in PV string without disconnection of individual modules in the string.

14 SOLAR ENERGY↗

Direct observation of dual-step twinning nucleation in hexagonal close-packed crystals

Design and processing of advanced lightweight structural alloys based on magnesium and titanium rely critically on a control over twinning which, however, remains elusive to date and is dependent on an explicit understanding on the twinning nucleation mechanism in hexagonal close-packed (HCP) crystals. Here, by using in-situ high resolution transmission electron microscopy, we directly reveal a “dual-step” twinning nucleation mechanism in HCP rhenium nanocrystals. It is found that nucleation of the predominant {10 -12} twinning is initiated by disconnections on the Prismatic¦Basal interfaces which establish the lattice correspondence of the twin with a minor deviation from the ideal orientation. Subsequently, the minor deviation is corrected by the formation of coherent twin boundaries through rearrangement of the disconnections on the Prismatic¦Basal interface; thereafter, the coherent twin boundaries propagate by twinning disconnections. The findings provide much-needed high-resolution evidences to the twinning nucleation mechanism in HCP crystals, with crucial implications for engineering advanced structural alloys.

36 MATERIALS SCIENCE↗

Interstitial hydrogen enhances the mobility of some grain boundaries in tungsten

Segregation of interstitials at a grain boundary (GB) is known to generally lower its mobility. This phenomenon, called 'solute-drag', has important ramifications on the process of recrystallization and microstructural evolution. Here, we present predictions from molecular dynamics (MD) simulations which demonstrate that interstitial hydrogen in tungsten can in fact increase the mobility of some GBs which exhibit shear coupling. Assuming a disconnection-based mechanism, activation energies and pre-factors for disconnection nucleation are predicted from simulations of shear-coupled motion. In GBs where enhanced mobility is predicted, interstitial H reduces both the activation energy and the pre-factor for disconnection nucleation, thus effectively increasing the mobility. For GBs with diminished mobility, MD predicts that presence of interstitial H reduces the pre-factor and, in some cases, increases the activation energy. The reduction in the activation energy inferred from MD simulations are confirmed by nudged elastic band calculations. Temperature-dependent structural transitions are observed for some GBs, and the effect of interstitial H is found to change with the changes in structure. The effect of interstitial H is predicted to be complex and highly variable, providing some plausible explanations for experimental observations on the recrystallization of tungsten in presence of H-loaded plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spread Spectrum Time Domain Reflectivity for String Monitoring in PV Power Plants (Final Technical Report)

This final report describes the methods and results of applying Spread Spectrum Time Domain Reflectivity (SSTDR) for String Monitoring in PV Power Plants for DE-EE0008169. The project created a new system for both detecting and locating electrical faults in photovoltaic systems. In this work, we address photovoltaic electric faults that are both common and costly. Based on interviews with photovoltaic power plant owners, operators, and maintainers, three types of faults are common and of significant interest: disconnects, ground faults, and arc faults. Disconnects can originate from many sources. They are often due to everyday events, such as lawnmowing (accidentally running over a cable), animals eating through the cables, or degradation that occurs over time due to corrosion or general degradation. Ground faults occur when the cables (for example, due to frayed insolation) connect to the ground, relaying current into the ground. These faults are particularly problematic since the ground faults are often intermittent. That is, ground faults commonly appear during rain storms due to a change in soil conductivity and then disappear when the rain ends. This makes the ground fault difficult to find because while current systems can detect the overall change in voltage and current associated with a ground fault, technicians are necessary to locate the fault. As a result, ground faults may disappear before the technician arrives at the power plant. Hence, locating and fixing ground faults often require multiple trips. We also study arc faults, which can result when nearby conductors create an arc of electrical current through the air. While less common, arc faults can be extremely dangerous. The energetic electrical arc can cause fires and destroy equipment, costing significant damage. Overall all three types of faults cost owners and operators money, either from the destruction of equipment or from technician time. Furthermore, while devices exist for detecting ground faults (ground fault circuit interrupters) and arc faults (arc fault circuit interrupter), these systems only search patterns of electrical current that correspond to each fault. This information cannot be used to locate the fault. In addition, these protection systems experience nuisance trips due to nearby electromagnetic interference, such as from a lawn mower or other motors that produce significant amounts of electromagnetic radiation. Hence, the overall goal of this project is to create an SSTDR tool that provides photovoltaic power plants with more reliable fault detection in addition to the localization of faults. SSTDR works by transmitting electrical signals into the photovoltaic string. Those signals reflect from impedance discontinuities (i.e., disconnects, ground faults, and arc faults). These faults are then detected by measuring the presence of a reflection at the SSTDR and can be located by identifying the location of that reflection in time. In addition, unlike current protection systems, these systems do not experience nuisance trips since their low amplitude, high frequency, and coded signal can by analyzed without interference from the regular operational voltage on the photovoltaic string.

14 SOLAR ENERGY↗

EMP Testing of NAE Magnetic Motor Starters

Sandia National Laboratories (SNL) performed a high-altitude nuclear electromagnetic pulse (HEMP) critical generation station component vulnerability test campaign with a focus on high-frequency, conducted early-time (E1) HEMP for the Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER). This report provides vulnerability test results to investigate component response and/or damage thresholds to reasonable HEMP threat levels that will help to inform site vulnerability assessments, mitigation planning, and modeling calibrations. This work details testing of North American Electric (NAE) magnetic motor starters to determine the effects of conducted HEMP environments. Motor starters are the control elements that provide power to motors throughout a generating plant; a starter going offline would cause loss of power to critical pumps and compressors, which could lead to component damage or unplanned plant outages. Additionally, failed starters would be unable to support plant startup. Six industrial motor starters were tested: two 2 horsepower (HP) starters with breaker disconnects and typical protection equipment, two 20 HP starters with breaker disconnects, and two 20 HP starters with fused disconnects. Each starter was placed in a circuit with a generator and inductive motor matching the starter rating. The conducted EMP insult was injected on the power cables passing through the motor starter, with separate tests for the generator and motor sides of the starter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Spread Spectrum Time Domain Reflectometry (SSTDR) Digital Twin Simulation of Photovoltaic Systems for Fault Detection and Location

Utilizing spread spectrum time domain reflectometry (SSTDR) to detect, locate, and characterize faults in photovoltaic (PV) systems is examined in this paper. We present a method to obtain the model parameters that are needed to produce digital twin SSTDR responses for PV systems. The digital twin SSTDR responses could be used to predict faults within the PV systems. Here, the model parameters are the reflection and transmission coefficients at each impedance discontinuity in the PV system along with the propagation coefficients across each PV cable segment. We obtain model parameter by applying inverse modeling techniques to experimental SSTDR data associated with PV systems. Our model parameters can be used in any digital twin simulation method for modeling reflectometry in frequency-dependent and complex loads. For validation, we used the model parameters in a graph network simulation engine and adapted it to be used for SSTDR digital twin simulations in PV systems. We produced simulations for 0 to 10 PV modules connected in series. We also simulated SSTDR responses for open circuit disconnections in a PV setup containing 10 PV modules in series. Results show that all but one simulated disconnect locations match experimental disconnection locations of the same setup with an error of less than 5%.

14 SOLAR ENERGY↗

Source circuit design considerations

The cost of several circuit configurations for large (5MW) array fields were investigated to assess the relative costs of high and low voltage configurations. Three source circuit NOC voltages were evaluated: 400V (ungrounded), 800V (+ or 400V center grounded), and 2000V (+ or - 1000V center grounded). Four source circuit configurations were considered for each of the three NOC voltages. The configurations correspond to source circuit currents of 15, 30, 45, and 60 amperes, respectively. Conceptual layouts for 5MW building blocks for each of the above configurations were developed. The designs were optimized to minimize BOS electrical and structural costs. Only the BOS electrical costs were evaluated. The designs were broken down into the following elements for cost: (1) basic source circuit intermodule wiring, bypass diodes and associated hardware, source circuit to J-Box wiring, etc; (2) J-Box blocking diodes, varistors, heat sinks, and housing; (3) disconnects source circuit disconnects, fuses, and housing; (4) bus cabling J-Box to PCU interface wiring, and trenching; (5) interface bus bar, group disconnects, and fuses; and (6) fault detection shunts, signal wire, electronics, and alarm. It is concluded that high voltage low current circuits are not economical, at higher currents high and low voltage circuit costs approach each other, high voltage circuits are not likely to offer near term advantage, and development work/manufacturer stimulation is needed to develop low cost high voltage hardware.

Noel, G. T.↗

A direct-interface, fusible heat sink for astronaut cooling

Astronaut cooling during extravehicular activity is a critical design issue in developing a portable life support system that meets the requirements of a space station mission. Some of the requirements are that the cooling device can be easily regenerable and nonventing during operation. In response to this, a direct-interface, fusible heat sink prototype with freezable quick-disconnects was developed. A proof-of-concept prototype was constructed and tested that consists of an elastic container filled with normal tap water and having two quick-disconnects embedded in a wall. These quick-disconnects are designed so that they may be frozen with the ice and yet still be joined to the cooling system, allowing an immediate flow path. The inherent difficulties in a direct-interface heat sink have been overcome, i.e., (1) establishing an initial flow path; (2) avoiding low-flow freeze-up; and (3) achieving adequate heat-transfer rates at the end of the melting process. The requirements, design, fabrication, and testing are discussed.

Lomax, Curtis↗

A direct-interface fusible heat sink for astronaut cooling

Astronaut cooling during extravehicular activity is a critical design issue in developing a portable life support system that meets the requirements of a space station mission. Some the requirements are that the cooling device can be easily regenerable and nonventing during operation. In response to this, a direct-interface, fusible heat sink prototpye with freezable quick-disconnects was developed. A proof-of-concept prototype was constructed and tested that consists of an elastic container filled with normal tap water and having two quick-disconnects embedded in a wall. These quick-disconnects are designed so that they may be frozen with the ice and yet still be joined to the cooling system, allowing an immediate flow path. The inherent difficulties in a direct-interface heat sink have been overcome, i.e., (1) establishing an initial flow path; (2) avoiding low-flow freeze-up; and (3) achieving adequate heat-transfer rates at the end of the melting process. The requirements, design, fabrication, and testing are discussed.

Lomax, Curtis↗

Customized Hermetic Feedthrough Developed to Isolate Fluids

A common problem occurs when refrigerant fluids wick inside the insulation of thermocouple wires through a compressor's casing feedthrough and then leak into the adjacent disconnect box outside the casing. Leaking fluids create an unfavorable situation inside the disconnect box and may contaminate the fluids. To address this problem, NASA Lewis Research Center s Manufacturing Engineering Division developed a customized hermetic feedthrough for a bank of Worthington compressors. In these compressors, bearing temperatures are measured by internal thermocouples embedded in bearings located inside the compressor casings. The thermocouple wires need to be routed outside the casing and read at another location. These wires are short and are terminated to a disconnect strip inside the casing. The bearings operate at about 170 F, but because the casing is filled with R12 refrigerant oil, the casing has a maximum temperature of about 100 F. The operating conditions of these compressors permit the use of an epoxy that is compatible with the R12 fluid. The desired finished product is a stainless steel tube that has been filled solid with epoxy after thermocouple wires bonded and sealed by epoxy have been inserted through its length. Shrink tubing extends from both ends of the tube. The process that was developed to isolate the thermocouple wires from the R12 fluid follows. For this application, use an 8-in.-long piece of 0.500-in. 304 stainless steel tube with six pairs of 24-gauge stranded, PTFE-insulated (polytetrafluoroethylene) type "T" thermocouple wires for each feedthrough. Use shrink tubing to strain relief the insulated wires at their exit from the stainless steel tube. Cut the wire to length and identify the location of the stainless steel tube sleeve with masking tape. Then, remove the outer insulation from a 2-in. section of wire that will be inside the tube, and carefully strip to bare wire a 1-in. section in the middle of the section with the outer insulation removed. For an effective seal, the epoxy must penetrate between the strands when stranded conductors are used. Make the seal with epoxy bond on the bare wire. The bare wire must be encapsulated with a thin layer of the epoxy that leaves only a very low profile. These encapsulated wires must cure before the assembly can be continued. Then, inspect the cured wires for complete encapsulation before going to the next step. Insert the wires in the stainless steel tube and orient them so that the epoxied stripped sections are staggered within the tube; then, apply shrink tubing to one end of the cleaned wires, positioning it inside the edge of the tube. The small gaps between the wires on the other end will be used to inject the epoxy into the tube. Let the epoxy cure inside the tube, free of any voids. Then, continue to fill the tube until the entire 8-in. length is nearly filled, allowing room for the other strain-relieving shrink tubing. Since this first design, the process has been adjusted to fit many needs and situations. Customized feedthroughs have been assembled from various wire types, wire gauges, and/or stainless steel tube passages. The fittings selected to mount these feedthroughs allow their use in other areas, such as pressure or vacuum systems.

Meredith, Roger D.↗

Cryogenic Transport of High-Pressure-System Recharge Gas

A method of relatively safe, compact, efficient recharging of a high-pressure room-temperature gas supply has been proposed. In this method, the gas would be liquefied at the source for transport as a cryogenic fluid at or slightly above atmospheric pressure. Upon reaching the destination, a simple heating/expansion process would be used to (1) convert the transported cryogenic fluid to the room-temperature, high-pressure gaseous form in which it is intended to be utilized and (2) transfer the resulting gas to the storage tank of the system to be recharged. In conventional practice for recharging high-pressure-gas systems, gases are transported at room temperature in high-pressure tanks. For recharging a given system to a specified pressure, a transport tank must contain the recharge gas at a much higher pressure. At the destination, the transport tank is connected to the system storage tank to be recharged, and the pressures in the transport tank and the system storage tank are allowed to equalize. One major disadvantage of the conventional approach is that the high transport pressure poses a hazard. Another disadvantage is the waste of a significant amount of recharge gas. Because the transport tank is disconnected from the system storage tank when it is at the specified system recharge pressure, the transport tank still contains a significant amount of recharge gas (typically on the order of half of the amount transported) that cannot be used. In the proposed method, the cryogenic fluid would be transported in a suitably thermally insulated tank that would be capable of withstanding the recharge pressure of the destination tank. The tank would be equipped with quick-disconnect fluid-transfer fittings and with a low-power electric heater (which would not be used during transport). In preparation for transport, a relief valve would be attached via one of the quick-disconnect fittings (see figure). During transport, the interior of the tank would be kept at a near-ambient pressure far below the recharge pressure. As leakage of heat into the tank caused vaporization of the cryogenic fluid, the resulting gas would be vented through the relief valve, which would be set to maintain the pressure in the tank at the transport value. Inasmuch as the density of a cryogenic fluid at atmospheric pressure greatly exceeds that of the corresponding gas in a practical high-pressure tank at room temperature, a tank for transporting a given mass of gas according to the proposed method could be smaller (and, hence, less massive) than is a tank needed for transporting the same mass of gas according to the conventional method.

Ungar, Eugene K,↗

Suited Occupant Injury Potential During Dynamic Spacecraft Flight Phases

In support of the Constellation Space Suit Element [CSSE], a new space-suit architecture will be created for support of Launch, Entry, Abort, Microgravity Extra- Vehicular Activity [EVA], and post-landing crew operations, safety and, under emergency conditions, survival. The space suit is unique in comparison to previous launch, entry, and abort [LEA] suit architectures in that it utilizes rigid mobility elements in the scye (i.e., shoulder) and the upper arm regions. The suit architecture also utilizes rigid thigh disconnect elements to create a quick disconnect approximately located above the knee. This feature allows commonality of the lower portion of the suit (from the thigh disconnect down), making the lower legs common across two suit configurations. This suit must interface with the Orion vehicle seat subsystem, which includes seat components, lateral supports, and restraints. Due to the unique configuration of spacesuit mobility elements, combined with the need to provide occupant protection during dynamic vehicle events, risks have been identified with potential injury due to the suit characteristics described above. To address the risk concerns, a test series has been developed in coordination with the Injury Biomechanics Research Laboratory [IBRL] to evaluate the likelihood and consequences of these potential issues. Testing includes use of Anthropomorphic Test Devices [ATDs; vernacularly referred to as "crash test dummies"], Post Mortem Human Subjects [PMHS], and representative seat/suit hardware in combination with high linear acceleration events. The ensuing treatment focuses on test purpose and objectives; test hardware, facility, and setup; and preliminary results.

Dub, Mark O.↗

Performance and Safety Tests of Lithium-Ion Cells Arranged in a Matrix Design Configuration

Matrix Packs display large variations in cell bank voltages at the charge and discharge current (C/2) used in this test program. The voltage difference is larger at the end of discharge than at the end of charge under the conditions studied. Disconnection of a cell from the pack leads to a larger voltage difference during discharge (greater than 2.0 V) between the bank that has one less cell and the other banks. Thermal profile does not show any significant changes or increase in temperature after one cell was disconnected from the bank in spite of falling to very low voltages at the end of discharge. All tests on the matrix pack with the HAM displayed lower max in general due to the placement of thermocouple on the outside of the HAM rather than on the cells. Disconnection of cells has almost no influence on the performance of the packs and does not show any abnormal thermal changes for the 100 cycles obtained in this test program. Longer cycle life may influence the performance especially if the low voltage cell goes into reversal. Overcharge leads to CID activation of cells. If the matrix configuration has a larger number of cells in series, (more than 5 S configuration), the limitations of protective devices may manifest itself irrespective of it being in a matrix configuration. External short circuit causes a fire with expulsion of content from some cells. The fire does not propagate itself laterally, but if there was cell module stacking, then the fire would cause the cells above it to also go into flames/thermal runaway. Limitations of protective devices are observed in this case as the PTCs in the cells did not protect under this abusive condition. Matrix configurations seem to provide protection against lateral propagation of fire and flame. Matrix pack configuration seems to provide good performance in spite of losing cell connections; at least for the configuration tested under this program.

Jeevarajan, Judith↗

Pilot/Controller Coordinated Decision Making in the Next Generation Air Transportation System

Introduction: NextGen technologies promise to provide considerable benefits in terms of enhancing operations and improving safety. However, there needs to be a thorough human factors evaluation of the way these systems will change the way in which pilot and controllers share information. The likely impact of these new technologies on pilot/controller coordinated decision making is considered in this paper using the "operational, informational and evaluative disconnect" framework. Method: Five participant focus groups were held. Participants were four experts in human factors, between x and x research students and a technical expert. The participant focus group evaluated five key NextGen technologies to identify issues that made different disconnects more or less likely. Results: Issues that were identified were: Decision Making will not necessarily improve because pilots and controllers possess the same information; Having a common information source does not mean pilots and controllers are looking at the same information; High levels of automation may lead to disconnects between the technology and pilots/controllers; Common information sources may become the definitive source for information; Overconfidence in the automation may lead to situations where appropriate breakdowns are not initiated. Discussion: The issues that were identified lead to recommendations that need to be considered in the development of NextGen technologies. The current state of development of these technologies provides a good opportunity to utilize recommendations at an early stage so that NextGen technologies do not lead to difficulties in resolving breakdowns in coordinated decision making.

Bearman, Chris↗