Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “discharge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Investigation of nanosecond pulsed dielectric barrier discharge using plate-to-plate electrode with asymmetric dielectric arrangement in airflow

Atmospheric pressure dielectric barrier discharge plasma is produced in airflow by applying nanosecond high voltage pulses with peak voltage about 35 kV and rising time about 40 ns on a plate-to-plate electrode arrangement. The effects of airflow rate (0–50 m/s) on the discharge characteristics are investigated under different barrier conditions (the bare anode case and the bare cathode case). For both cases, the breakdown voltage and the time lag increase distinctly and the discharge intensity decreases sharply when the airflow rate increases from 0 to 30 m/s, and then keep almost constant until the airflow rate is further increased to 50 m/s. For the bare anode case (the cathode is covered by dielectric plate), the discharge mode transforms gradually from filamentary to diffuse discharge with the increasing airflow rate. While for the bare cathode case, some micro-discharge channels are still excited, though the discharge becomes more diffuse when the airflow rate is higher than 30 m/s. By acquiring the time-resolved images of the discharge, it is proved that it is the primary discharge which becomes diffuse when airflow is introduced and the following two discharges of the same voltage pulse occur principally at the positions where the primary discharge is more intense. And in both cases, the plasma temperatures are reduced, but the degree is different. All the phenomena can be explained mainly by the variation of the space charge distribution when the airflow is introduced into the discharge gap. And it is indicated that the bare anode case has an advantage in obtaining diffuse discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hydrodynamic model of a dielectric-barrier discharge in pure chlorine

A one-dimensional hydrodynamic model of a dielectric-barrier discharge (DBD) in pure chlorine is developed, and the properties of the discharge are modeled. The discharge is excited in an 8-mm-long discharge gap between 2-mm-thick dielectric quartz layers covering metal electrodes. The DBD spatiotemporal characteristics at gas pressures of 15–100 Torr are modeled for the case in which a 100-kHz harmonic voltage with an amplitude of 8 kV is applied to the electrodes. The average power density deposited in the discharge over one voltage period is 2.5–5.8 W/cm{sup 3}. It is shown that ions and electrons absorb about 95 and 5% of the discharge power, respectively. In this case, from 67 to 97% of the power absorbed by electrons is spent on the dissociation and ionization of Cl{sub 2} molecules. Two phases can be distinguished in the discharge dynamics: the active (multispike) phase, which follows the breakdown of the discharge gap, and the passive phase. The active phase is characterized by the presence of multiple current spikes, a relatively high current, small surface charge density on the dielectrics, and large voltage drop across the discharge gap. The passive phase (with no current spikes) is characterized by a low current, large surface charge density on the dielectrics, and small voltage drop across the discharge gap. The peak current density in the spikes at all pressures is about 4 mA/cm{sup 2}. In the multispike phase, there are distinct space charge sheaths with thicknesses of 1.5–1.8 mm and a mean electron energy of 4.3–7 eV and the central region of quasineutral plasma with a weak electric field and a mean electron energy of 0.8–3 eV. The degree of ionization of chlorine molecules in the discharge is ~0.02% at a pressure of 15 Torr and ~0.01% at 100 Torr. The DBD plasma is electronegative due to the fast attachment of electrons to chlorine atoms: e + Cl{sub 2} → Cl + Cl{sup –}. The most abundant charged particles are Cl{sub 2}{sup +} and Cl{sup −} ions, and the degree of ionization during current spikes in the active phase is (4.1–5.5) × 10{sup –7}. The mechanism of discharge sustainment is analyzed. The appearance of a series of current spikes in the active phase of the discharge is explained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Space Induced Discharge Model to Be Used on Interface Circuit Vulnerability Assessment

Charging can occur in space due to plasma and high energy particles. Charging is especially severe in certain earth orbits such as geostationary orbit, medium earth orbit and highly inclined orbit. A spacecraft that travels to other planets such as Jupiter also encounters high level of charging due to Jupiter’s radiation belt. The major concern for spacecraft operation due to charging is the survival of sensitive electrical circuits. Dielectrics and floating metal can charge up and discharge onto interface circuits. The electrical circuits need to be evaluated for survival from the electrostatic-discharge (ESD) threat. Both ESD induced upset and damage need to be assessed. The interface circuits are often located inside a shielded unit in the spacecraft structure or a shielded vault with sufficient radiation shielding to avoid surface and internal charging. The materials external to the highly shielded area can charge up and discharge onto wires that can directly dissipate the ESD onto the interface circuits. Figure 1 shows a possible discharge mechanism onto the interfacing circuits. If the wire has an external shield or a coaxial line, some or most of the discharge can flow on the shield to chassis ground. There is always coupling from external discharge. If the wire has no shield, the discharge flows onto the interface circuit. Fig. 1 Possible discharge paths onto the interface circuits. The purpose of this article is to address how to model the ESD threat to be used as the discharge source onto the interface circuit based on the electron beam test data. Different models are needed for different impedances associated with the interface circuits. Once those models are derived, one needs to analyze the interface circuit with the corresponding model using an electrical simulation tool. Then, the circuit’s front-end components can be assessed for damage and upset. Upset is highly dependent on the circuit operation and system requirements, and thus it is not addressed any further. Damage of electrical parts is often rated under Human-Body-Model (HBM) ESD. One can utilize this industry-wide available information to assess the damage vulnerability due to space discharges. However, the HBM waveform does not always match the discharge waveform. To estimate the damage vulnerability of the circuit and set margin, one needs to compare the equivalent energy delivered to the victim between a HBM discharge and the results from an ESD source model based on actual discharges. This paper presents such a comparison for a few select cases.

Xie, Julie↗

Two-dimensional simulation of spatiotemporal generation of dielectric barrier columnar discharges in atmospheric helium

A two-dimensional (2D) fluid model is presented to investigate the spatiotemporal generation and dynamic mechanics of dielectric barrier columnar discharges in atmospheric helium. The model was examined with discharge currents measured in experiments and images taken by an intensified charge couple device camera. Based on the model, a columnar discharge was simulated for several cycles after being ignited. The discharge could be regarded as an initial unstable stage for the first three and a half cycles, then a steady state for the following cycles. In the initial stage, the discharge evolves from a uniform pattern into a columnar one. The calculated equipotential lines, 2D radial electric field, and electron density distributions at the edge of uniform discharges show the radial electric field accounts for the shrinking discharge area and the formation of discharge columns in the end. The columnar glow discharges and the Townsend discharges beyond the columns could coexist in the initial stage, and a Townsend discharge might develop into a new glow column in the next half-cycle. The radial electric field surrounding a glow discharge column has an inhibiting effect on the ionization in the peripheral area.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The impact of multi-sensor land data assimilation on river discharge estimation

River discharge is one of the most critical renewable water resources. Accurately estimating river discharge with land surface models (LSMs) remains challenging due to the difficulty in estimating land water storages such as snow, soil moisture, and groundwater. While data assimilation (DA) ingesting optical, microwave, and gravity measurements from space can help constrain theses storage states, its impacts on runoff and eventually river discharge are not fully understood. In this study, by taking advantage of recently published land DA results that jointly assimilate eight different combinations of observations from the Moderate Resolution Imaging Spectroradiometer (MODIS), Gravity Recovery and Climate Experiment (GRACE), and Advanced Microwave Scanning Radiometer for EOS (AMSR-E), we quantify to what degree multi-sensor land DA improves the river discharge simulation skills over 40 global river basins, and investigate the complementary strengths of different satellite measurements on river discharge. To be more specific, river discharge is updated by feeding gridded runoff from the eight multi-sensor DA simulations into a vector-based river routing model named the Routing Application for Parallel computatIon of Discharge (RAPID). Our modeling results, including 7-year simulations at 177,458 river reaches globally, are used to study the seasonal to interannual variability of river discharge. It is found that assimilating GRACE has the greatest impact on global runoff patterns, leading to the most pronounced improvements in spatial river discharge in the middle and high latitudes with the R 2 increased by 0.16. The seasonal variation of spatial discharge is most skillful during the boreal summer. However, our evaluation also shows model and DA still struggle to generate reasonable variability and averaged discharge over permafrost regions. Finally, by assessing how different satellites add value to discharge forecasts, this study paves the way for more advanced multi-sensor satellite data assimilation to predict the terrestrial hydrological cycle.

54 ENVIRONMENTAL SCIENCES↗

Non-linear macro evolution of a dc driven micro atmospheric glow discharge

We studied the macro evolution of the micro atmospheric glow discharge generated between a micro argon jet into ambient air and static water. The micro discharge behaves similarly to a complex ecosystem. Non-linear behaviors are found for the micro discharge when the water acts as a cathode, different from the discharge when water behaves as an anode. Groups of snapshots of the micro discharge formed at different discharge currents are captured by an intensified charge-coupled device with controlled exposure time, and each group consisted of 256 images taken in succession. Edge detection methods are used to identify the water surface and then the total brightness is defined by adding up the signal counts over the area of the micro discharge. Motions of the water surface at different discharge currents show that the water surface lowers increasingly rapidly when the water acts as a cathode. In contrast, the water surface lowers at a constant speed when the water behaves as an anode. The light curves are similar to logistic growth curves, suggesting that a self-inhibition process occurs in the micro discharge. Meanwhile, the total brightness increases linearly during the same time when the water acts as an anode. Discharge-water interactions cause the micro discharge to evolve. The charged particle bomb process is probably responsible for the different behaviors of the micro discharges when the water acts as cathode and anode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Lawrence Livermore National Laboratory (LLNL) Experimental Test Site (Site 300) Salinity Evaluation and Minimization Plan for Cooling Towers and Mechanical Equipment Discharges

This document was created to comply with the Central Valley Regional Water Quality Control Board (CVRWQCB) Waste Discharge Requirement (Order No. 98-148). This order established new requirements to assess the effect of and effort required to reduce salts in process water discharged to the subsurface. This includes the review of technical, operational, and management options available to reduce total dissolved solids (TDS) concentrations in cooling tower and mechanical equipment water discharges at Lawrence Livermore National Laboratory's (LLNL's) Experimental Test Site (Site 300) facility. It was observed that for the six cooling towers currently in operation, the total volume of groundwater used as make up water is about 27 gallons per minute and the discharge to the subsurface via percolation pits is 13 gallons per minute. The extracted groundwater has a TDS concentration of 700 mg/L. The cooling tower discharge concentrations range from 700 to 1,400 mg/L. There is also a small volume of mechanical equipment effluent being discharged to percolation pits, with a TDS range from 400 to 3,300 mg/L. The cooling towers and mechanical equipment are maintained and operated in a satisfactory manner. No major leaks were identified. Currently, there are no re-use options being employed. Several approaches known to reduce the blow down flow rate and/or TDS concentration being discharged to the percolation pits and septic systems were reviewed for technical feasibility and cost efficiency. These options range from efforts as simple as eliminating leaks to implementing advanced and innovative treatment methods. The various options considered, and their anticipated effect on water consumption, discharge volumes, and reduced concentrations are listed and compared in this report. Based on the assessment, it was recommended that there is enough variability in equipment usage, chemistry, flow rate, and discharge configurations that each discharge location at Site 300 should be considered separately when deciding on an approach for reducing the salt discharge to the subsurface. The smaller units may justify moderate changes to equipment, and may benefit from increased cleaning frequencies, more accurate and suitable chemical treatment, and sources of make up water and discharge re-use. The larger cooling towers would be more suitable for automated systems where they don't already exist, re-circulation and treatment of blow down water, and enhanced chemical dosing strategies. It may be more technically feasible and cost efficient for the smaller cooling towers to be replaced by closed loop dry coolers or hybrid towers. There are several potential steps that could be taken at each location to reduce the TDS concentration and/or water use. These include: sump water filtration, minimization of drift, accurate chemical dosing, and use of scale and corrosion coupons for chemical calibration. The implementation of some of these options could be achieved by a step-wise approach taken at two representative facilities. Once viable prototype systems have been proven in the field, systematic implementation should proceed for the remaining systems, with cost, desired reduction, and general feasibility taken into consideration for such systems.

54 ENVIRONMENTAL SCIENCES↗

Ammonia generation in Ns pulse and Ns pulse/RF discharges over a catalytic surface

Plasma-catalytic ammonia synthesis in a ns pulse discharge and a 'hybrid' ns pulse/RF discharge in plane-to-plane geometry is studied by Fourier Transform infrared absorption spectroscopy. The data are taken in a preheated H 2 –N 2 mixture, with and without Ni/γ-Al 2 O 3 or Co/γ-Al 2 O 3 catalyst placed in the discharge section. The measurement results are taken using two different approaches. The first is a 'single-stage' process, where a ns pulse discharge in the H 2 –N 2 mixture is sustained continuously. In this case, the ammonia yield increases slowly, over a period of tens of minutes. The second is a 'two-stage' process, where the catalyst is first activated by the ns pulse discharge sustained in pure nitrogen, and then the activated catalyst is exposed to the H 2 –N 2 flow, with or without the discharge. In this case, a strong overshoot of the NH 3 number density at the reactor exit is detected, by over a factor of two compared to the single-stage process. After the initial overshoot, the ammonia yield gradually decreases to the 'single stage' value (with the discharge on), or to near zero (with the discharge off). The results demonstrate that the ammonia yield in the plasma-catalytic reactor is controlled by the N atom accumulation on the catalyst surface, which reacts with H atoms thermally dissociated on the catalyst or generated in the plasma. The results also show that the plasma-catalytic ammonia yield is significantly higher compared to that in the ns pulse discharge without the catalyst. The accumulation of H atoms on the catalyst, with their subsequent reactions with N atoms generated in the plasma, is of relatively minor importance at the present conditions. An additional series of measurements was made with a sub-breakdown RF waveform overlapped with the ns pulse discharge train, to enhance the vibrational excitation of nitrogen. The ammonia yield measured with the RF waveform added is approximately 20% higher compared to that at the baseline ns pulse discharge conditions, both with and without the catalyst. This effect is weaker compared to that of the catalyst activation by N atoms. Additional data are necessary to isolate the possible effect of the vibrationally excited N 2 molecules on the ammonia synthesis in the plasma catalytic reactions.

surface reactions↗

Optimal discharge placement in plasma-assisted combustion of a methane jet in cross flow

Repetitively pulsed, nonequilibrium plasma discharges are studied for their ability to ignite and stabilize methane jet flames in cross flow air. The placement of the discharge is surveyed to optimize the flame duty cycle (stability). We find that flame ignition is not achieved when the discharge is located in the potential core region of the fuel jet or on the windward side of the most upstream part of the near field of the jet. A low (but nonzero) duty cycle is seen when the discharge is placed on the leeward side of the upstream near-field region. A high duty cycle (up to unity) is seen for discharge placement on both the leeward and windward sides of the downstream part of the near field. These results confirm that the effectiveness of the nonequilibrium discharge in stabilizing this flame depends on its placement in the complex scalar and velocity field. The mixture fraction at the discharge placement is characterized by plasma-induced breakdown spectroscopy (PIBS). The ratio of emission intensity of the CN band at 388 nm to the N{sub 2} band at 337 nm is used to map the local equivalence ratio in the flow. We find that the methane mixture fraction at optimal discharge placements is lower than that where the flame resides in non-discharge-stabilized diffusion flames and is equal to that found in plasma-assisted methane jets in coflow air. Planar laser-induced fluorescence (PLIF) imaging of CH radicals is carried out to qualitatively understand the structure of the ignition flame kernel. The plasma discharge and flame base are spatially separated, suggesting that the discharge is a steady supplier of reactive species but not an instantaneous flame ignition source. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Methodology to evaluate design modifications intended to eliminate frosting and high discharge temperatures in air-source heat pumps (ASHPs) in cold climates

Air-source heat pumps (ASHPs) operating in cold climates experience problems with frosting and high refrigerant temperatures. These problems increase energy consumption, and their severity depends on the climatic conditions. In the present paper, a methodology for identifying the prevailing problem between frosting and high discharge temperatures is presented. Three performance indices, the frosting index (FI), the discharge index (DI), and the total loss index (TLI), are proposed to quantify the impacts of frosting and high discharge temperatures on the annual performance of ASHPs in different climatic conditions. The FI and DI show which problem (frosting or high discharge temperature) dominates, and the TLI indicates the combined effect of frosting and high discharge temperatures on the performance of an ASHP. A thermodynamic model of an ASHP coupled with the TRNSYS building simulation tool is used to estimate the performance of an ASHP and the proposed loss indices to estimate the impact of both frosting and high discharge temperatures for 45 cities in Canada. The results can be extended to other parts of the world that experience similar climatic conditions The results reveal that in cities in ASHRAE climatic zones 5 and 6 (classified as cold regions) where the ambient air temperatures are predominantly between -15 °C to 6 °C, ASHPs are heavily impacted by frosting. The problem of high discharge temperatures in ASHPs is predominant in cities in climate zones 7 and 8 (classified as very cold and subarctic regions) where the temperatures are frequently below -20 °C in winter. Among the cities considered, St. John, NL has the highest fraction of heating hours experiencing frosting (90 %), where the annual increase in energy consumption due to frosting is 13.5 % of the annual heating energy consumption. The highest annual increase in energy consumption due to high discharge temperatures is in Isachsen, NU (zone 8), where the increase is 30 % of the annual heating energy consumption. Based on the proposed indices, another index called the performance gain index (PGI) is created, which can be used as a first step to assess the energy-saving potential of design modifications applied to ASHPs to solve the problems of frosting and high discharge temperatures. The PGI will aid in developing climate specific ASHPs. One possible design modification is the use of a two-stage ASHP with an economizer. It is observed that the two-stage ASHP with economizer can mitigate high discharge temperatures and improve performance in very cold and subarctic regions (zones 7 and 8). However, it is not as beneficial in zones 5 and 6, where the impact of high discharge temperatures on performance is minimal and frosting dominates. Finally, a case study, using the PGI to evaluate the economic and environmental effectiveness of a two-stage ASHP with economizer is presented for the city of Saskatoon.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effects of inter-pulse coupling on nanosecond pulsed high frequency discharge ignition in a flowing mixture

This work numerically investigates the effects of non-equilibrium nanosecond plasma discharge pulse rep- etition frequency, pulse number, and flow velocity on the critical ignition volume, minimum ignition energy, and chemistry in a plasma-assisted H 2 /air flow at 300 K and 1 atm using a multi-scale adaptive reduced chemistry solver for plasma assisted combustion (MARCS-PAC). The interactions between discharges/ignition kernels spanning decoupled, partially-coupled and fully-coupled regimes in a pulse train are studied. For a single pulse discharge, increased flow velocity increases the minimum ignition energy required due to the increase of convective heat loss and flame stretch. The results show that the minimum ignition kernel prop- agation speed at the critical ignition kernel volume increases with the flow velocity. The minimum critical ignition volume decreases with the increase of plasma discharge energy. For sequential two-pulse discharges, ignition fails at both decoupled and partially-coupled regimes even when the total discharge energy is above the minimum ignition energy, but succeeds only in the fully-coupled regime at a shorter inter-pulse time. Overlap of the OH radical pool between the sequential two-pulse discharges and the increase of the chemistry effect due to the increase of reduced electric field in the fully-coupled regime contribute to the ignition enhancement. In addition, for two-pulse discharges in the fully-coupled discharge regime, the mixture can be ignited at a total energy below the minimum ignition energy of a single pulse with the same flow conditions. Moreover, for a given total discharge energy with multiple pulsed discharges, the enhancement of the ignition kernel volume has a non-monotonic dependence on discharge frequency and pulse number. The effective ignition enhancement can be achieved with an optimal pulse repetition frequency and pulse number. Furthermore, this work provides a new understanding of the mechanism for repetitive plasma ignition and insights for the optimization of plasma ignition in a reactive flow.

42 ENGINEERING↗

Numerical simulation of operation modes in atmospheric pressure uniform barrier discharge excited by a saw-tooth voltage

The characteristics of dielectric barrier discharge excited by a saw-tooth voltage are simulated in atmospheric pressure helium based on a one-dimensional fluid model. A stepped discharge is obtained per half voltage cycle with gas gap width less than 2 mm by the simulation, which is different to the pulsed discharge excited by a sinusoidal voltage. For the stepped discharge, the plateau duration increases with increasing the voltage amplitude and decreasing the gas gap. Therefore, uniform discharge with high temporal duty ratio can be realized with small gap through increasing the voltage amplitude. The maximal densities of both electron and ion appear near the anode and the electric field is almost uniformly distributed along the gap, which indicates that the stepped discharge belongs to a Townsend mode. In contrast to the stepped discharge with small gas gap, a pulsed discharge can be obtained with large gas gap. Through analyzing the spatial density distributions of electron and ion and the electric field, the pulsed discharge is in a glow mode. The voltage-current (V-I) characteristics are analyzed for the above mentioned discharges under different gas gaps, from which the different discharge modes are verified.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the physical processes ruling an atmospheric pressure air glow discharge operating in an intermediate current regime

Low-frequency (100 Hz), intermediate-current (50 to 200 mA) glow discharges were experimentally investigated in atmospheric pressure air between blunt copper electrodes. Voltage–current characteristics and images of the discharge for different inter-electrode distances are reported. A cathode-fall voltage close to 360 V and a current density at the cathode surface of about 11 A/cm{sup 2}, both independent of the discharge current, were found. The visible emissive structure of the discharge resembles to that of a typical low-pressure glow, thus suggesting a glow-like electric field distribution in the discharge. A kinetic model for the discharge ionization processes is also presented with the aim of identifying the main physical processes ruling the discharge behavior. The numerical results indicate the presence of a non-equilibrium plasma with rather high gas temperature (above 4000 K) leading to the production of components such as NO, O, and N which are usually absent in low-current glows. Hence, the ionization by electron-impact is replaced by associative ionization, which is independent of the reduced electric field. This leads to a negative current-voltage characteristic curve, in spite of the glow-like features of the discharge. On the other hand, several estimations show that the discharge seems to be stabilized by heat conduction; being thermally stable due to its reduced size. All the quoted results indicate that although this discharge regime might be considered to be close to an arc, it is still a glow discharge as demonstrated by its overall properties, supported also by the presence of thermal non-equilibrium.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Critical Role of the Routing Scheme in Simulating Peak River Discharge in Global Hydrological Models

Global hydrological models (GHMs) have been applied to assess global flood hazards, but their capacity to capture the timing and amplitude of peak river discharge which is crucial in flood simulations has traditionally not been the focus of examination. Here we evaluate to what degree the choice of river routing scheme affects simulations of peak discharge and may help to provide better agreement with observations. To this end we use runoff and discharge simulations of nine GHMs forced by observational climate data (1971-2010) within the ISIMIP2a (Inter-Sectoral Impact Model Intercomparison Project phase 2a) project. The runoff simulations were used as input for the global river routing model CaMa-Flood (Catchment-based Macro-scale Floodplain). The simulated daily discharge was compared to the discharge generated by each GHM using its native river routing scheme. For each GHM both versions of simulated discharge were compared to monthly and daily discharge observations from 1701 GRDC (Global Runoff Data Centre) stations as a benchmark. CaMa-Flood routing shows a general reduction of peak river discharge and a delay of about two to three weeks in its occurrence, likely induced by the buffering capacity of floodplain reservoirs. For a majority of river basins, discharge produced by CaMa-Flood resulted in a better agreement with observations. In particular, maximum daily discharge was adjusted, with a multi-model averaged reduction in bias over about two-thirds of the analysed basin area. The increase in agreement was obtained in both managed and near-natural basins. Overall, this study demonstrates the importance of routing scheme choice in peak discharge simulation, where CaMa-Flood routing accounts for floodplain storage and backwater effects that are not represented in most GHMs. Our study provides important hints that an explicit parameterisation of these processes may be essential in future impact studies.

peak river discharge↗

Edge-Propagation Discharge Mechanism in CFx Batteries—A First-Principles and Experimental Study

Graphite fluoride (CF x ) cathodes coupled with lithium anodes yield one of the highest theoretical specific capacities (>860 mAh/g) among primary batteries. In practice, the observed discharge voltage (~2.5 V) is significantly lower than thermodynamic limits (>4.5 V), the discharge rate is low, and so far Li/CF x has only been used in primary batteries. Understanding the discharge mechanism at atomic length scales will improve practical CFx energy density, rate capability, and rechargeability. So far, purely experimental techniques have not identified the correct discharge mechanism or explained the discharge voltage. In this work, we apply density functional theory calculations to demonstrate that a CF x -edge propagation discharge mechanism based on lithium insertion at the CF/C boundary in partially discharged CF x exhibits a voltage range of 2.5 to 2.9 V—depending on whether solvent molecules are involved. The voltages and solvent dependence agree with our discharge and galvanostatic intermittent titration technique measurements. The predicted discharge kinetics are consistent with CF x operations. Finally, we predict some Li/CF x rechargeability under the application of high potentials, along a charging pathway different from that of discharge. Our work represents a general, quasi-kinetic framework to understand the discharge of conversion cathodes, circumventing the widely used phase diagram approach which most likely does not apply to Li/CF x because equilibrium conditions are not attained in this system.

25 ENERGY STORAGE↗

Discharge Chamber Performance of the NEXIS Ion Thruster

The Nuclear-Electric Xenon Ion System (NEXIS) thruster was designed to produce greater than or equal to 70% efficiency at ISPs in excess of 6500 sec and total power levels in excess of 15 kW. In order to achieve this performance, the thruster requires a large area plasma generator capable of high propellant utilimtion efficiency and low discharge loss while producing a very flat, uniform beam profile. Fortunately, larger thrusters can be made more uniform and efficient due to the higher volume to surface ratio, provided that the magnetic cusp confinement is designed properly and the thruster length to diameter ratio is adequate. This paper describes the discharge chamber performance of the NEXIS Laboratory Model (LM) thruster. The LM discharge chamber is 65 cm in diameter at the grid plane and uses 6 ring-cusps to provide magnetic confinement of the plasma. The thruster was tested with flat carbon-carbon composite grids with the hole pattern masked to 57 cm in diameter and a conventional Type-B "1/2" diameter hollow cathode. During the preliminary "discharge only" tests, the LM thruster demonstrated profile factors of 0.84 and a discharge loss of about 160 eV/ion at 25 V discharge voltage and over 90% propellant utilization efficiency in simulated beam extraction experiments at 3.9 A of beam current. Analysis of the data from these tests used the discharge-only model developed by Brophy. Subsequent beam extraction experiments validated the key variables used in the model to predict the performance from the discharge-only data, and demonstrated 3.9 A of beam current at over 90% propellant utilization efficiency with a flatness parameter of better than 0.8 and a discharge loss of about 185 eV/ion. The slightly higher discharge loss measured during beam extractions was found to be due to a lower screen transparency in the as-manufactured LM grid set. Plasma measurements with a scanning probe internal to the thruster near the screen grid showed plasma densities over l x 10(exp 11) per cubic centimeter and electron temperatures of 3.5 to 5.5 eV depending on the operation parameters. The performance of the NEXIS discharge chamber contributed to the over 78% thruster efficiency measured during beam extraction at 7500 sec ISP and 25 kW of power, and over 81% thruster efficiency measured at 8500 sec ISP.

plasma generation↗

Temporally, spatially, and spectrally resolved barrier discharge produced in trapped helium gas at atmospheric pressure

Experimental study was made on induced effects by trapped helium gas in the pulsed positive dielectric barrier discharge (DBD) operating in symmetrical electrode configuration at atmospheric pressure. Using fast photography technique and electrical measurements, the differences in the discharge regimes between the stationary and the flowing helium are investigated. It was shown experimentally that the trapped gas atmosphere (TGA) has notable impact on the barrier discharge regime compared with the influence of the flowing gas atmosphere. According to our experimental results, the DBD discharge produced in trapped helium gas can be categorized as a multi-glow (pseudo-glow) discharge, each discharge working in the sub-normal glow regime. This conclusion is made by considering the duration of current pulse (few {mu}s), their maximum values (tens of mA), the presence of negative slope on the voltage-current characteristic, and the spatio-temporal evolution of the most representative excited species in the discharge gap. The paper focuses on the space-time distribution of the active species with a view to better understand the pseudo-glow discharge mechanism. The physical basis for these effects was suggested. A transition to filamentary discharge is suppressed in TGA mode due to the formation of supplementary source of seed electrons by surface processes (by desorption of electrons due to vibrationally excited nitrogen molecules, originated from barriers surfaces) rather than volume processes (by enhanced Penning ionisation). Finally, we show that the pseudo-glow discharge can be generated by working gas trapping only; maintaining unchanged all the electrical and constructive parameters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impact of In Situ Chemical Oxidation on Contaminant Mass Discharge: Linking Source-Zone and Plume-Scale Characterizations of Remediation Performance

A large-scale permanganate-based in situ chemical oxidation (ISCO) effort has been conducted over the past ten years at a federal Superfund site in Tucson, AZ, for which trichloroethene (TCE) is the primary contaminant of concern. Remediation performance was assessed by examining the impact of treatment on contaminant mass discharge, an approach that has been used for only a very few prior ISCO projects. Contaminant mass discharge tests were conducted before and after permanganate injection to measure the impact at the source-zone scale. The results indicate that ISCO caused a significant reduction in mass discharge (approximately 75%). The standard approach of characterizing discharge at the source-zone scale was supplemented with additional characterization at the plume scale, which was evaluated by examining the change in contaminant mass discharge associated with the pump-and-treat system. The integrated contaminant mass discharge decreased by approximately 70%, consistent with the source-zone-scale measurements. The integrated mass discharge rebounded from 0.1 to 0.2 kg/d within one year after cessation of permanganate injections, after which it has been stable for several years. Collection of the integrated contaminant mass discharge data throughout the ISCO treatment period provided a high-resolution, real-time analysis of the site-wide impact of ISCO, thereby linking source-zone remediation to impacts on overall risk. The results indicate that ISCO was successful in reducing contaminant mass discharge at this site, which comprises a highly heterogeneous subsurface environment. Analysis of TCE sediment concentration data for core material collected before and after ISCO supports the hypothesis that the remaining mass discharge is associated in part with poorly accessible contaminant mass residing within lower permeability zones.

54 ENVIRONMENTAL SCIENCES↗