Filtration Performance Results: Sierra Peaks Material No. 4

Sandia National Laboratories (SNL) assessed the filtration performance of materials from Sierra Peaks to identify alternatives which may perform similarly to materials used in FDA-approved N95 respirators. This work is meant to characterize the aerosol performance of materials to give Sierra Peaks information for them to determine if they elect to submit masks made using these materials for follow-on N95 certification testing at an accredited facility. The R&D testbed used is a large-scale filtration system designed to test commercial filter boxes. System modifications were performed to simulate, where possible, parameters defined by the National Institute for Occupational Safety and Health (NIOSH) for certification of filter materials for N95 respirators (NIOSH 2019). The system is a pull-through design. Air enters through a Laminar Flow Element (LFE) and the volumetric flow is measured based on the pressure drop across the LFE. Pressure is measured via a Pressure Transducer (PT). The air then passes through a High Efficiency Particulate Air (HEPA) filter to purge the air of ambient airborne particulates. Test aerosol is injected into the flow shortly after and mixing is induced via a coarse mesh. The airflow is allowed to fully develop prior to arriving at the test section. The aerosol then passes through the test material mounted in a box in the test section. Pressure drop across the test article is measured and aerosol sampling probes measure the aerosol concentrations upstream and downstream of the sample. The air passes through a second HEPA filter prior to being exhausted to ambient by a blower. A Topas aerosol generator is used to produce the test aerosol from Sodium Chloride (NaC1) dissolved in deionized (DI) water. Generated aerosol passes through a heated mixing chamber and a desiccant dryer to produce nanosized solid-state particulates. A dilution loop allows for the aerosol concentration to be regulated. The aerosol sampling probes upstream and downstream of the test section are aligned with the flow path. These are ducted directly to the aerosol sizing and counting instruments. A Laser Aerosol Spectrometer (LAS) was used for data collection in the original configuration of the system and was also used for initial testing in this project. Because the lower measurement range for the LAS is 90 nanometers (nm), the LAS was switched out for a more complicated Scanning Mobility Particle Sizer (SMPS) spectrometer system. The SMPS is comprised of an Electrostatic Classifier (EC), Differential Mobility Analyzer (DMA), and a Condensation Particle Counter (CPC). This enabled data collection at 75 nm, the particle size called out in the NIOSH guidelines.

36 MATERIALS SCIENCE↗

Measuring Local Turbulence Along the Optical Path: Multi-Beam Optical Seeing Sensor

Deflection of light along the optical path is a major source of image degradation for ground-based telescopes. Methods have been developed to measure upper atmospheric seeing based on models of the turbulence in the atmosphere, but due to boundary conditions, transmission within telescope enclosures is more complex. The Multi-beam Optical Seeing Sensor (MOSS) directly measures the component of the image quality degradation from inhomogeneity of the index of refraction within the telescope dome. MOSS outputs four near-parallel beams of light that travel along the optical path and are imaged by the telescope’s detector, landing like starlight on the telescope’s focal plane. By using a strobed light source, we can ‘freeze’ the instantaneous index variations transverse to the optical path. This system captures both ‘dome’ and ‘mirror’ seeing. Through plotting the standard deviation of differential motion between pairs of beams, MOSS enables characterization of the length scale of turbulence within the dome. The temporal coherence of temperature gradients can be probed with different pulse lengths, and the spatial coherence by comparing pairs at different separations across the aperture of the telescope. Optical path turbulence measurements, alongside other telemetry metrics, will guide thermal and airflow management to optimize image quality. A MOSS prototype was installed in the 1.2[Formula: see text]m Auxiliary Telescope (AuxTel) at the Vera C. Rubin Observatory in Chile, and preliminary data constrain the optical path turbulence with a lower bound of 1.4 arcsec. The optical path turbulence varied throughout the night of observing.

Astronomical seeing↗

Experimental clean combustor program: Phase 3: Turbulence measurement addendum

Airflow turbulence parameters were measured in the high pressure, high temperature flow stream leaving the compressor of an operating gas turbine engine. A water cooled hot film turbulence probe was used to determine the turbulence intensity and length scale in the compressor exit flow stream of the CF6-50 engine. Data were obtained only at idle operating conditions. At engine power levels above idle conditions, durability problems and erratic data readings were encountered with the turbulence measurement probes. Turbulence measurements were made at three radial immersions at a point 15.5 cm downstream of the compressor outlet guide vanes in the compressor exit diffuser. The passage height at this point is 5.54 cm. Data reduction was accomplished with a time-data fast Fourier transform (FFT) system. This system finds the power spectral density distribution (PSD) of a large number of data samples using a direct Fourier transform algorithm and finds the autocorrelation parameter for these data by doing an FFT analysis of the PSD curves for a series of time delay intervals.

Taylor, J. R.↗

Flow quality studies of the NASA Lewis Research Center Icing Research Tunnel

A series of studies have been conducted to determine the flow quality in the NASA Lewis Icing Research Tunnel. The primary purpose of these studies was to document airflow characteristics, including flow angularity, in the test section and tunnel loop. A vertically mounted rake was used to survey total and static pressure and two components of flow angle at three axial stations within the test section (test section inlet, test plane, and test section exit; 15 survey stations total). This information will be used to develop methods of improving the aerodynamic and icing characteristics within the test section. The data from surveys made in the tunnel loop were used to determine areas where overall tunnel flow quality and efficiency can be improved. A separate report documents similar flow quality surveys conducted in the diffuser section of the Icing Research Tunnel. The flow quality studies were conducted at several locations around the tunnel loop. Pressure, velocity, and flow angularity measurements were made by using both fixed and translating probes. Although surveys were made throughout the tunnel loop, emphasis was placed on the test section and tunnel areas directly upstream of the test section (settling chamber, bellmouth, and cooler). Flow visualization, by video recording smoke and tuft patterns, was also used during these studies. A great deal of flow visualization work was conducted in the area of the drive fan. Information gathered there will be used to improve the flow quality upstream and downstream of the fan.

Arrington, E. Allen↗

Airplane Ice Detector Based on a Microwave Transmission Line

An electronic instrument that could detect the potentially dangerous buildup of ice on an airplane wing is undergoing development. The instrument is based on a microwave transmission line configured as a capacitance probe: at selected spots, the transmission-line conductors are partly exposed to allow any ice and/or liquid water present at those spots to act as predominantly capacitive electrical loads on the transmission line. These loads change the input impedance of the transmission line, as measured at a suitable excitation frequency. Thus, it should be possible to infer the presence of ice and/or liquid water from measurements of the input impedance and/or electrical parameters related to the input impedance. The sensory transmission line is of the microstrip type and thus thin enough to be placed on an airplane wing without unduly disturbing airflow in flight. The sensory spots are small areas from which the upper layer of the microstrip has been removed to allow any liquid water or ice on the surface to reach the transmission line. The sensory spots are spaced at nominal open-circuit points, which are at intervals of a half wavelength (in the transmission line, not in air) at the excitation frequency. The excitation frequency used in the experiments has been 1 GHz, for which a half wavelength in the transmission line is .4 in. (.10 cm). The figure depicts a laboratory prototype of the instrument. The impedance-related quantities chosen for use in this version of the instrument are the magnitude and phase of the scattering parameter S11 as manifested in the in-phase (I ) and quadrature (Q) outputs of the phase detector. By careful layout of the transmission line (including the half-wavelength sensor spacing), one can ensure that the amplitude and phase of the input to the phase detector keep shifting in the same direction as ice forms on one or more of the sensor areas. Although only one transmission-line sensor strip is used in the laboratory version, in a practical application, it could be desirable to install multiple strips on different areas to detect localized icing. In that case, a multiplexer should be used to connect the various strips to the phase detector for sequential measurements. Experiments have been performed with freezing and thawing of water and of water/glycol mixtures. The experiments have shown that, whether or not glycol is present, it is possible to distinguish between liquid water and ice via the I and Q outputs; in particular, the equipment can be adjusted so that when water freezes, I decreases and Q increases. With respect to the operation of this instrument, the main effect of glycol is to increase the freezing or thawing time.

Ngo, Phong↗

Coupling Mesoscale Budget Components to Large-Eddy Simulations for Wind-Energy Applications

To simulate the airflow through a wind farm across a wide range of atmospheric conditions, microscale models (e.g., large-eddy simulation, LES, models) have to be coupled with mesoscale models, because microscale models lack the atmospheric physical processes to represent time-varying local forcing. Here we couple mesoscale model outputs to a LES solver by applying mesoscale momentum- and temperature-budget components from the Weather Research and Forecasting model to the governing equations of the Simulator fOr Wind Farm Applications model. We test whether averaging the budget components affects the LES results with regard to quantities of interest to wind energy. Our study focuses on flat terrain during a quiescent diurnal cycle. The simulation results are compared with observations from a 200-m tall meteorological tower and a wind-profiling radar, by analyzing time series, profiles, rotor-averaged quantities, and spectra. However, while results show that averaging reduces the spatio-temporal variability of the mesoscale momentum-budget components, when coupled with the LES model, the mesoscale bias (in comparison with observations of wind speed and direction, and potential temperature) is not reduced. In contrast, the LES technique can correct for shear and veer. In both cases, however, averaging the budget components shows no significant impact on the mean flow quantities in the microscale and is not necessary when coupling mesocale budget components to the LES model.

17 WIND ENERGY↗

Computational Assessment of a 3-Stage Axial Compressor Which Provides Airflow to the NASA 11- by 11-Foot Transonic Wind Tunnel, Including Design Changes for Increased Performance

A 24 foot diameter 3-stage axial compressor powered by variable-speed induction motors provides the airflow in the closed-return 11- by 11-Foot Transonic Wind Tunnel (11-Foot TWT) Facility at NASA Ames Research Center at Moffett Field, California. The facility is part of the Unitary Plan Wind Tunnel, which was completed in 1955. Since then, upgrades made to the 11-Foot TWT such as flow conditioning devices and instrumentation have increased blockage and pressure loss in the tunnel, somewhat reducing the peak Mach number capability of the test section. Due to erosion effects on the existing aluminum alloy rotor blades, fabrication of new steel rotor blades is planned. This presents an opportunity to increase the Mach number capability of the tunnel by redesigning the compressor for increased pressure ratio. Challenging design constraints exist for any proposed design, demanding the use of the existing driveline, rotor disks, stator vanes, and hub and casing flow paths, so as to minimize cost and installation time. The current effort was undertaken to characterize the performance of the existing compressor design using available design tools and computational fluid dynamics (CFD) codes and subsequently recommend a new compressor design to achieve higher pressure ratio, which directly correlates with increased test section Mach number. The constant cross-sectional area of the compressor leads to highly diffusion factors, which presents a challenge in simulating the existing design. The CFD code APNASA was used to simulate the aerodynamic performance of the existing compressor. The simulations were compared to performance predictions from the HT0300 turbomachinery design and analysis code, and to compressor performance data taken during a 1997 facility test. It was found that the CFD simulations were sensitive to endwall leakages associated with stator buttons, and to a lesser degree, under-stator-platform flow recirculation at the hub. When stator button leakages were modeled, pumping capability increased by over 20 of pressure rise at design point due to a large reduction in aerodynamic blockage at the hub. Incorporating the stator button leakages was crucial to matching test data. Under-stator-platform flow recirculation was thought to be large due to a lack of seals. The effect of this recirculation was assessed with APNASA simulations recirculating 0.5, 1, and 2 of inlet flow about stators 1 and 2, modeled as axisymmetric mass flux boundary conditions on the hub before and after the vanes. The injection of flow ahead of the stators tended to re-energize the boundary layer and reduce hub separations, resulting in about 3 increased stall margin per 1 of inlet flow recirculated. In order to assess the value of the flow recirculation, a mixing plane simulation of the compressor which gridded the under-stator cavities was generated using the ADPAC CFD code. This simulation indicated that about 0.65 of the inlet flow is recirculated around each shrouded stator. This collective information was applied during the redesign of the compressor. A potential design was identified using HT0300 which improved overall pressure ratio by removing pre-swirl into rotor 1, replacing existing NASA 65 series rotors with double circular arc sections, and re-staggering rotors and the existing stators. The performance of the new design predicted by APNASA and HT0300 is compared to the existing design.

Turbomachinery↗

Towards replacing physical testing of granular materials with a Topology-based Model

In the study of packed granular materials, the performance of a sample (e.g., the detonation of a high-energy explosive) often correlates to measurements of a fluid flowing through it. The “effective surface area,” the surface area accessible to the airflow, is typically measured using a permeametry apparatus that relates the flow conductance to the permeable surface area via the Carman-Kozeny equation. This equation allows calculating the flow rate of a fluid flowing through the granules packed in the sample for a given pressure drop. However, Carman-Kozeny makes inherent assumptions about tunnel shapes and flow paths that may not accurately hold in situations where the particles possess a wide distribution in shapes, sizes, and aspect ratios, as is true with many powdered systems of technological and commercial interest. To address this challenge, we replicate these measurements virtually on micro-CT images of the powdered material, introducing a new Pore Network Model based on the skeleton of the Morse-Smale complex. Pores are identified as basins of the complex, their incidence encodes adjacency, and the conductivity of the capillary between them is computed from the cross-section at their interface. We build and solve a resistive network to compute an approximate laminar fluid flow through the pore structure. Here, we provide two means of estimating flow-permeable surface area: (i) by direct computation of conductivity, and (ii) by identifying dead-ends in the flow coupled with isosurface extraction and the application of the Carman-Kozeny equation, with the aim of establishing consistency over a range of particle shapes, sizes, porosity levels, and void distribution patterns.

36 MATERIALS SCIENCE↗

Numerical Investigation of Enhanced Dehumidification Processes By Using Dielectrophoresis Principles in Moist Airflows

Dispersed particle-laden flows are encountered in many building and industrial applications, such as flow in a fluidized bed, hydrocarbon transportation in pipelines, and the fouling of air-cooled heat exchangers (Kuruneru et al., 2016; Ray et al., 2019; Wang et al., 2019). Computational fluid dynamic (CFD) models have been developed in recent years to depict particle-fluid and particle-particle interactions in laminar or turbulent flows with increasing accuracy and stability. One particular particle-laden system of interest for moisture control is electrically-enhanced condensation in air and water droplet flows. Electrically-enhanced condensation consists of the use of highly charged water droplets injected in the moist air. The droplets become electric seeds that attract polar water vapor molecules to their surfaces and promote condensation. The nucleation and growth of the charged droplets deplete the vapor phase near a droplet, which is compensated for by the dielectrophoresis flow and diffusion. Dielectrophoresis flow involves surrounding vapor at a distance of about 10 to 100 nm for droplets charged by an electrospray compared to ~2 nm for a single electron charge in a droplet. As the vapor molecules collapse on the surface of the droplets, their initial electrical charge decreases with time due to the neutralization of the ions. While the physics of this phenomena is well known, engineering models for predicting the condensation rates are not available. This work computationally investigates dehumidification of moist airflow in a converging rectangular duct. The objective is to develop an engineering model that predicts water vapor condensation by employing dielectrophoresis principles. We construct a Computational Fluid Dynamics (CFD) model of the duct with electrically-enhanced condensation. The model is implemented in the open-source software OpenFOAM. We utilize the Multi-Phase Particle-In-Cell (MP-PIC) method coupled with a Population Balance Equation (PBE) approach to simulate the particle-laden system. This methodology is an Eulerian-Lagrangian approach used to simulate the droplets' behavior in the humid air. The MP-PIC approach (Andrews and O'Rourke, 1996) mitigates the computational cost by parceling several fundamental particles with similar properties (such as types, sizes, and temperature) into one computational particle. Thus, the billions of particles can be substituted by millions of computational particles without significant loss of information. The PBE was considered with the Lagrangian frame to combine the particle distribution function used in MP-PIC (Kim et al., 2020). This approach preserves mass and energy conservation between the phases in the Eulerian and Lagrangian structures. The PBE in this procedure was directly linked to the discrete parcels, making the simulation of the particle distribution computationally efficient and robust. The MP-PIC-PBE approach used in the present work was applied to the dehumidification of air. Water droplets were injected in the air stream and forced to grow according to experimentally derived correlation. The experiments were conducted on a converging duct with the same geometry and boundary conditions used to build the CFD model. This approach enabled us to approximate the effect of dielectrophoresis phenomena on the droplet and air interface. This presentation will discuss the details of the new CFD model built for the duct, the implementation of the model in OpenFOAM CFD programming language, and the experimental validation of the newly developed model. The results revealed a moderate yet measurable increase in droplet diameter due to water vapor condensation at the vapor-liquid interface of the electrically charged droplets' surface. The seed water droplet particles grew in size by capturing the water vapor in the surrounding air. The OpenFOAM model predicted reductions of humidity in the air from 5 to 10 percent.

Yel Mahi, Maliha↗

3-D CFD in a day - The laser digitizer project

The computation of airflow over complex configurations requires a complete description of the geometry. This can be obtained from CAD data, from blueprints, or from actual models. In any case, the time required is currently estimated at 4 to 6 months. It is proposed to shorten this time by a factor of 10 to 100 through the use of automated software, a fast, highly parallel computer and a three-dimensional laser digitizer. This device can provide (x,y,z) coordinates of surface points at rates exceeding 14,500/sec. Thus, it is possible to digitize an entire model in a few minutes. The accuracy of measurement on a flat white surface is better than 0.005 inches. Higher accuracy is available at higher cost. This work discusses the challenges which remain to be addressed. In particular, the surface point data need to be converted into a surface description, the surface description needs to be made into a surface grid, and the surface grid used to make a volume grid for the flow solver. Algorithms are kept in place or in mind for all of these problems. Integration of the more mature flow solution and visualization algorithms then allows generation of solution graphics directly from a wind tunnel model.

Merriam, Marshal↗

WIPP Safety Significant Confinement Ventilation System (SSCVS) HEPA Filtration System - 20165

Construction and major equipment fabrication are underway for a new ventilation exhaust system at the Waste Isolation Pilot Plant (WIPP). The new system will provide continuous High Efficiency Particulate Air (HEPA) filtration of the exhaust from the WIPP underground while meeting the ventilation demands for expanded waste emplacement and mining operations over the next 40 years. The integrated system design provides for reducing the salt, clay and diesel particulates from the exhaust airflow from the mine, prior to full filtration using Nuclear Safety Significant HEPA filters. The SSCVS design and equipment provides for continuous HEPA filtration over a wide range of operating and environmental conditions. The new exhaust system connects to the existing underground exhaust shaft, and the exhaust air flows from the underground through Salt Reduction Units (SRUs) to protect the final filter banks from excessive moisture and rapid salt/dust buildup. Each of the six (6) SRUs consists of a demister to remove entrained moisture, a dry salt remover unit to filter approximately 90% of the entrained salt/dust, and an automated water treatment system to periodically clean the demisters and to remove salt from the SRU filters. At the maximum expected exhaust flowrate of 540,000 Cubic Feet per Minute (CFM) / 255 Cubic Meters per Second (m{sup 3}/s), five (5) salt removal units will be in operation with one unit in standby or maintenance. An in-line variable frequency drive booster fan will offset pressure losses through each SRU and reduce the relative humidity of the air exiting the SRUs. In the event of a high radiation alarm from the underground Continuous Air Monitors (CAMs), the SRUs will be automatically bypassed, which places the SRS and building outside of the Safety Significant confinement boundary. From the SRUs, the exhaust is directed to the HEPA filter banks located in the New Filter Building. The exhaust system is designed to provide continuous HEPA filtration prior to release to the exhaust stack. There are 22 HEPA filter banks rated at 27,000 CFM / 12.75 m{sup 3}/s each. Each filter bank has two stages of pre-filters and two stages of HEPA filters. The filtered air from each of the 22 filter banks discharges into a common concrete plenum, which is maintained under a negative pressure by the main exhaust fans. Six 1,000 HP variable frequency drive exhaust fans are provided on the south side of the plenum. At the maximum expected exhaust flow of 540,000 CFM, four exhaust fans and twenty filter banks will be in operation. The fans discharge vertically to a separate concrete exhaust plenum. The filtered exhaust is routed from the exhaust plenum to a 125-foot-tall exhaust stack via a 13-foot diameter duct. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dynamic Testing of the NASA Hypersonic Project Combined Cycle Engine Testbed for Mode Transition Experiments

NASA is interested in developing technology that leads to more routine, safe, and affordable access to space. Access to space using airbreathing propulsion systems has potential to meet these objectives based on Airbreathing Access to Space (AAS) system studies. To this end, the NASA Fundamental Aeronautics Program (FAP) Hypersonic Project is conducting fundamental research on a Turbine Based Combined Cycle (TBCC) propulsion system. The TBCC being studied considers a dual flow-path inlet system. One flow-path includes variable geometry to regulate airflow to a turbine engine cycle. The turbine cycle provides propulsion from take-off to supersonic flight. The second flow-path supports a dual-mode scramjet (DMSJ) cycle which would be initiated at supersonic speed to further accelerate the vehicle to hypersonic speed. For a TBCC propulsion system to accelerate a vehicle from supersonic to hypersonic speed, a critical enabling technology is the ability to safely and effectively transition from the turbine to the DMSJ-referred to as mode transition. To experimentally test methods of mode transition, a Combined Cycle Engine (CCE) Large-scale Inlet testbed was designed with two flow paths-a low speed flow-path sized for a turbine cycle and a high speed flow-path designed for a DMSJ. This testbed system is identified as the CCE Large-Scale Inlet for Mode Transition studies (CCE-LIMX). The test plan for the CCE-LIMX in the NASA Glenn Research Center (GRC) 10- by 10-ft Supersonic Wind Tunnel (10x10 SWT) is segmented into multiple phases. The first phase is a matrix of inlet characterization (IC) tests to evaluate the inlet performance and establish the mode transition schedule. The second phase is a matrix of dynamic system identification (SysID) experiments designed to support closed-loop control development at mode transition schedule operating points for the CCE-LIMX. The third phase includes a direct demonstration of controlled mode transition using a closed loop control system developed with the data obtained from the first two phases. Plans for a fourth phase include mode transition experiments with a turbine engine. This paper, focusing on the first two phases of experiments, presents developed operational and analysis tools for streamlined testing and data reduction procedures.

Source record↗

Thermal Management Solution for an Integrated Outer-Rotor Motor Drive: Opportunities and Challenges

This work highlights an integrated thermal management solution for the outer-rotor motor (ORM) drive. The integrated ORM drive utilizes water-ethylene glycol coolant for power electronics and stator cooling. Air cooling is used for rotor laminations, magnets and outer-rotor structures, and the rotor shaft. To fully understand the performance of the integrated ORM drive and thermal management coupling effects, a full drive conjugate heat transfer model has been developed to investigate coupled cooling performance of various components of the ORM drive. Various motor rotational speeds, power output scenarios, and cooling options for the integrated ORM drive have been investigated. The model estimates the operating window for the ORM drive while keeping component operating temperatures below prescribed limits. The model also highlights the importance of windage losses at higher rotational speeds for this ORM design, which involves higher rotor surface area per unit width of the rotor. Different designs are also investigated, particularly focusing on rotor cooling with air either naturally induced by rotor spin or forced airflow with the help of a blower, to circumvent challenges imposed by higher windage losses. The work highlights motor rotational speed limitations and the need for potential liquid cooling options for desired rotor performance at higher rotational speeds. Liquid cooling for the rotor may even become more critical for nonuniform rotor-stator gaps, leading to even higher and uneven windage losses across the full circumference of the motor, consequentially, more heating for the rotor.

30 DIRECT ENERGY CONVERSION↗

Impact to Cooling Airflow from Truck Platooning

We investigate tradeoffs between the airflow strategies related to engine cooling and the aerodynamic-enabled fuel savings created by platooning. By analyzing air temperatures, engine temperatures and cooling air flow at different platoon distances, we show the thermal impact to the engine from truck platooning. Previously, we collected wind and thermal data for numerous heavy-duty truck platoon configurations (gaps ranging from 4 to 87 meters) and reported the significant fuel savings enabled by these configurations. The fuel consumption for all trucks in the platoon were measured using the SAE J1321 gravimetric procedure as well as calibrated J1939 instantaneous fuel rate while travelling at 65 mph and loaded to a gross weight of 65,000 lb. Using thermocouples mounted 1 m ahead of each truck, anemometers at the grill and a grid of under-hood thermocouples as well as J1939 reported engine temperatures, we analyze the impact to critical operating temperatures from different platoon configurations. Results show significant changes in the engine and under-hood air temperatures that correlate with vehicle gap distance and platoon position.

adaptive cruise control (ACC)↗

Machine learning enables reconstruction of past fire regimes from charcoal-derived fire intensity and fuel composition

Background Fire is a foundational ecological process that shapes ecosystem structure, diversity, and resilience. Quantifying paleofire regime attributes such as frequency, severity, and intensity is essential for understanding the historical range of variability in fire behavior and its ecological effects. While frequency and severity are often reconstructed in paleofire studies, quantitative reconstructions of fire intensity remain limited. Recent work has shown that maximum pyrolysis temperature—a proxy for fire intensity—and plant species type can be inferred from charcoal using transmission Fourier-transform infrared (FTIR) spectroscopy. However, the sample preparation for transmission FTIR is destructive and time-consuming, limiting application and reuse of materials for other analyses. We evaluated reflectance FTIR spectroscopy as a non-destructive alternative for reconstructing combustion temperature and plant species from laboratory-generated charcoal. We also examined the influence of contrasting airflow environments (ambient air versus nitrogen-rich) on pyrolysis temperature and plant species reconstruction prediction accuracies and compared predictive performance between a novel, neural network–based deep learning model with the traditional modern analogue technique (MAT) using k-nearest neighbor functions. As proof of concept, we apply our enhanced methodology to ancient charcoal to demonstrate applicability at improving long-term fire regime reconstructions and the ability to link paleofire records with contemporary fire ecology. Results Our analysis shows that transmission and reflectance FTIR spectra yield comparable spectral profiles. However, sample preparation for reflectance FTIR is minimal and non-destructive, unlike transmission FTIR which is destructive. We demonstrate that oxygen environments improved reconstruction accuracy relative to nitrogen-rich conditions. Finally, our deep learning neural network (DL) achieved testing accuracies of 98.7% for temperature and 96.2% for species identification, outperforming MAT’s k-NN approach (89.8% and 65.9%, respectively). A Shapley importance analysis identified 5 key spectral regions that greatly influenced the model’s temperature or species categorization. When applied to ancient charcoal, our results show historic fires from the most recent past primarily burned at low intensities (400–500 °C), reflective of natural fire regimes in ponderosa pine forests. Our results corroborate charcoal morphology data that suggests all ancient charcoal originated from burned woody plant types. Conclusions By combining reflectance FTIR spectroscopy with a deep learning approach, we provide the first accuracies high enough to confidently identify both species and temperature from laboratory-produced charcoal, improving quantitative reconstructions of fire intensity and fuel composition from paleofire records. This opens a wide range of research into the link between fire and larger drivers (i.e., climate or human) and greater ecological understanding of fire regimes beyond that of burn scars or recent observations. These methodological improvements have direct relevance for fire management by improving interpretation of historical fire behavior, informing fuel–fire relationships, and providing a scalable analytical framework applicable to both long-term ecological studies and contemporary fire science.

54 ENVIRONMENTAL SCIENCES↗

Dual-Fuel Ammonia Equivalence Ratio Sweep Data

Ammonia (NH3) has garnered significant interest as an alternative fuel for meeting international emissions reduction mandates in sectors with high weight and distance requirements, such as shipping. Technical barriers and unanswered questions remain on the combustion strategies that can maximize ammonia utilization and minimize emissions. Prior research studies at the US Department of Energy’s Oak Ridge National Laboratory have shown strong performance with NH3 under dual-fuel mode using conventional diesel combustion (CDC) manifold air pressure settings. Diesel airflow was initially used to simplify retrofitting (no turbocharger modification), which resulted in air-fuel equivalence ratios (λ) greater than 1.5. To characterize potential improvements in dual-fuel NH3 combustion performance at richer in-cylinder conditions, a global λ sweep compared the use of early (E-pilot) and late (L-pilot) single diesel injections. The experiments were conducted at 1200 RPM and 12.8 ± 0.2 bar (75 % load), and λ was varied by decreasing the commanded air flow to the engine at greater than 90 % ammonia energy substitution level. A diesel injection timing sweep was conducted for both the injection strategies at fixed λ, and the timing with the lowest engine-out N2O emissions was identified. The results indicated an optimal balance between CO2,eq and thermal efficiency benefits both E-pilot and L-pilot injection strategy cases compared with CDC at a λ of 1.4. The indicated nitrogen-based emissions exhibited a strong correlation to the ratio of CA5–50 and ignition delay for L-pilot, but no apparent trend emerged for the E-pilot injection strategy at the tested boundary conditions. This dataset includes the raw experimental data and documentation of the experiment conditions and methods.

30 DIRECT ENERGY CONVERSION↗