Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “direct detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Search for direct production of winos and higgsinos in events with two same-charge leptons or three leptons in $pp$ collision data at $\sqrt{s}$ = 13 TeV with the ATLAS detector

A search for supersymmetry targeting the direct production of winos and higgsinos is conducted in final states with either two leptons (e or μ) with the same electric charge, or three leptons. The analysis uses 139 fb -1 of pp collision data at $\sqrt{s}$ = 13 TeV collected with the ATLAS detector during Run 2 of the Large Hadron Collider. No significant excess over the Standard Model expectation is observed. Simplified and complete models with and without R-parity conservation are considered. In topologies with intermediate states including either Wh or WZ pairs, wino masses up to 525 GeV and 250 GeV are excluded, respectively, for a bino of vanishing mass. Higgsino masses smaller than 440 GeV are excluded in a natural R-parity-violating model with bilinear terms. Upper limits on the production cross section of generic events beyond the Standard Model as low as 40 ab are obtained in signal regions optimised for these models and also for an R-parity-violating scenario with baryon-number-violating higgsino decays into top quarks and jets. The analysis significantly improves sensitivity to supersymmetric models and other processes beyond the Standard Model that may contribute to the considered final states.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Application of Indirect Quantification of 133mXe to Calibration of HPGe Detector

The INL Noble Gas Laboratory provides intercomparison samples for the noble gas analysis laboratories as part of the CTBTO PrepCom IMS. Xe-133m is one of the four relevant radionuclides in nuclear explosion monitoring. Without commercially available Xe-133m calibration standards laboratories must create and improve calibration methods. Improvements in calibration methods at the INL NGL benefit the CTBTO PrepCom through better certified values for Xe-133m intercomparison samples. Calibration of High Purity Germanium detectors for Xe-133m quantification is complicated by the coexistence of Xe-133 in samples under analysis. Xe-133 is typically produced in larger quantities, has higher gamma emission probabilities, and its gammas are detected more efficiently than Xe-133m. Xe-133m activity of samples can be indirectly inferred through the 133:133m activity ratio of a batch of material, and the Xe-133 counts in the assay of a small aliquot of the same material. This indirect quantification method can be leveraged to perform detector calibrations for quantification of Xe-133m. Calibrations can be performed by inferring the Xe-133m to certify the sample, and direct counting to determine detector efficiency. A comparison of method results will be shown.

133mXe↗

Arbitrary electron dose waveforms for electron microscopy

A device may include an electron source, a detector, and a deflector. The electron source may be directed toward a sample area. The detector may receive an electron signal or an electron-induced signal. A deflector may be positioned between the electron source and the sample. The deflector may modulate an intensity of the electron source directed to the sample area according to an electron dose waveform having a continuously variable temporal profile.

Bloom, Ruth Shewmon↗

Arbitrary electron dose waveforms for electron microscopy

A device may include an electron source, a detector, and a deflector. The electron source may be directed toward a sample area. The detector may receive an electron signal or an electron-induced signal. A deflector may be positioned between the electron source and the sample. The deflector may modulate an intensity of the electron source directed to the sample area according to an electron dose waveform having a continuously variable temporal profile.

Bloom, Ruth Shewmon↗

Latest Constraints on Three-Flavor Neutrino Oscillation Parameters from the NOvA Experiment

NOvA, is a two-detector, long-baseline neutrino oscillation experiment located at Fermilab, Batavia, IL, USA. The NOvA experiment was designed primarily to constrain neutrino oscillation parameters by analyzing $\nu_\mu (\bar{\nu}_\mu)$ disappearance and $\nu_e (\bar{\nu}_e)$ appearance data observed at the far detector using a high purity beam of neutrinos and anti-neutrinos from Fermilab's NuMI beamline. The NOvA experiment consists of two functionally identical, finely granulated liquid tracking calorimeters, both situated 14.6 mrad off-axis to the beam direction. The NOvA near detector, situated 100 meters underground and 1 kilometer from the beam source, detects the non-oscillated $\nu_\mu (\bar{\nu}_\mu)$ and beam $\nu_e (\bar{\nu}_e)$ events. The far detector, located in Ash River, MN, USA, 810 kilometers from the beam source, records the non-oscillated $\nu_\mu (\bar{\nu}_\mu)$ and the oscillated $\nu_\mu (\bar{\nu}_\mu) \to \nu_e (\bar{\nu}_e)$ events. The most recent measurements of three flavor neutrino oscillation parameters based on an analysis of the data collected from neutrino-beam exposure of $26.60 \times 10^{20}$ POT and anti-neutrino beam exposure of $12.50\times 10^{20}$ POT including an additional low energy $\nu_e$ sample, will be discussed here.

Choudhary, Brajesh [Delhi U.] (ORCID:0000000150291↗

Simulating energetic particle losses in JET plasmas with a reverse integration biasing scheme

We report that an integrated energetic particle transport model has been constructed in JET plasmas constrained by experimental fast ion loss measurements. The model incorporates a synthetic fast ion loss detector identical to JET’s thin-foil Faraday cup fast ion loss detector array. The loss model combines analyses from the TRANSP and ORBIT-kick codes with enhanced features for producing the synthetic diagnostic. Extensions to the ORBIT code framework allow a full-orbit representation within the vacuum region that can map particles directly to an installed detector geometry. Since synthetic fast ion loss detectors are plagued by weak loss statistics, a novel reverse integration biasing scheme has been implemented to boost computational efficiency. The model is validated against experimental loss measurements induced by long-lived kink modes and is found to be in good agreement. This confirms the development of a fully integrated transport/loss model which can be quantitatively verified against experiment allowing for future validation and predictive studies. The model is particularly useful for more complicated plasma scenarios that involve multiple fast ion species such as JET’s 2021 DT-campaign.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Latest Results from the NOvA Experiment

NOvA, is a two-detector, long-baseline neutrino oscillation experiment located at Fermilab, Batavia, IL, USA. The NOvA experiment was designed primarily to constrain neutrino oscillation parameters by analyzing $\nu_\mu (\bar{\nu}_\mu)$ disappearance and $\nu_e (\bar{\nu}_e)$ appearance data observed at the far detector. The Neutrinos at Main Injector (NuMI) beamline at Fermilab provides a high purity beam of neutrinos and anti-neutrinos to the experiment. The NOvA experiment consists of two functionally identical, finely granulated liquid tracking calorimeters, both situated 14.6 mrad off-axis to the beam direction. The NOvA near detector, situated 100 meters underground and 1 kilometer from the beam source, detects the non-oscillated $\nu_\mu (\bar{\nu}_\mu)$ and beam $\nu_e (\bar{\nu}_e)$ events. The far detector, located in Ash River, MN, USA, 810 kilometers from the beam source, records the non-oscillated $\nu_\mu (\bar{\nu}_\mu)$ and the oscillated $\nu_\mu (\bar{\nu}_\mu) \to \nu_e (\bar{\nu}_e)$ events. The latest results on standard 3-flavor neutrino oscillations, joint NOvA-T2K analysis, active-to-sterile neutrino mixing, and non-standard interactions will be presented in this talk.

43 PARTICLE ACCELERATORS↗

Latest Constraints on Three-Flavor Neutrino Oscillation Parameters from the NOvA Experiment.

NOvA, is a two-detector, long-baseline neutrino oscillation experiment located at Fermilab, Batavia, IL, USA. The NOvA experiment was designed primarily to constrain neutrino oscillation parameters by analyzing $\nu_\mu (\bar{\nu}_\mu)$ disappearance and $\nu_e (\bar{\nu}_e)$ appearance data observed at the far detector. The Neutrinos at Main Injector (NuMI) beamline at Fermilab provides a high purity beam of neutrinos and anti-neutrinos to the experiment. The NOvA experiment consists of two functionally identical, finely granulated liquid tracking calorimeters, both situated 14.6 mrad off-axis to the beam direction. The NOvA near detector, situated 100 meters underground and 1 kilometer from the beam source, detects the non-oscillated $\nu_\mu (\bar{\nu}_\mu)$ and beam $\nu_e (\bar{\nu}_e)$ events. The far detector, located in Ash River, MN, USA, 810 kilometers from the beam source, records the non-oscillated $\nu_\mu (\bar{\nu}_\mu)$ and the oscillated $\nu_\mu (\bar{\nu}_\mu) \to \nu_e (\bar{\nu}_e)$ events. The most recent measurements of three flavor neutrino oscillation parameters based on an analysis of the data collected from neutrino-beam exposure of $26.60 \times 10^{20}$ POT and anti-neutrino beam exposure of $12.50\times 10^{20}$ POT including an additional low energy $\nu_e$ sample, will be presented in this talk.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Latest Three-Flavor Neutrino Oscillation Results from NOvA

NOvA, is a two-detector, long-baseline neutrino oscillation experiment located at Fermilab, Batavia, IL, USA. NOvA was designed primarily to constrain neutrino oscillation parameters by analyzing $\nu_\mu (\bar{\nu}_\mu)$ disappearance and $\nu_e (\bar{\nu}_e)$ appearance data at the far detector. The Neutrinos at Main Injector (NuMI) beamline at Fermilab provides a high purity beam of neutrinos and anti-neutrinos to the experiment. The NOvA experiments consists of two functionally identical, finely granulated liquid tracking calorimeters, both situated 14.6 mrad off-axis to the beam direction. The NOvA near detector, situated 100 meters underground and 1 kilometer from the beam source, detects the un-oscillated $\nu_\mu (\bar{\nu}_\mu)$ and beam $\nu_e (\bar{\nu}_e)$ events. The far detector, located in Ash River, MN, USA, 810 kilometers from the beam source, records the un-oscillated $\nu_\mu (\bar{\nu}_\mu)$ and the oscillated $\nu_e (\bar{\nu}_e)$ events. The most recent measurements of three flavor neutrino oscillation parameters based on an analysis of the data collected from a neutrino-beam exposure of $26.60 \times 10^{20}$ POT and an anti-neutrino beam exposure of $12.50\times 10^{20}$ POT with an additional low energy $\nu_e$ sample, will be presented in this talk.

Singh, Ishwar↗

Measurements and models of enhanced recombination following inner-shell vacancies in liquid xenon

Electron-capture decays of 125 Xe and 127 Xe , and double-electron-capture decays of 124 Xe , are backgrounds in searches for weakly interacting massive particles (WIMPs) conducted by dual-phase xenon time projection chambers such as LUX-ZEPLIN (LZ). These decays produce signals with more light and less charge than equivalent-energy 𝛽 decays and correspondingly overlap more with WIMP signals. We measure three electron-capture charge yields in LZ: the 1.1 keV M-shell, 5.2 keV L-shell, and 33.2 keV K-shell at drift fields of 193 and 96.5 V/cm. The LL double-electron-capture decay of 124 Xe exhibits even more pronounced shifts in charge and light. We provide a first model of double-electron-capture charge yields using the link between ionization density and electron-ion recombination, and identify a need for more accurate calculations. Finally, we discuss the implications of the reduced charge yield of these decays and other interactions creating inner-shell vacancies for future dark matter searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Directional Recoil Detection

Searches for dark matter–induced recoils have made impressive advances in the last few years. Yet the field is confronted by several outstanding problems. First, the inevitable background of solar neutrinos will soon inhibit the conclusive identification of many dark matter models. Second, and more fundamentally, current experiments have no practical way of confirming a detected signal's Galactic origin. The concept of directional detection addresses both of these issues while offering opportunities to study novel dark matter– and neutrino-related physics. The concept remains experimentally challenging, but gas time projection chambers are an increasingly attractive option and, when properly configured, would allow directional measurements of both nuclear and electron recoils. In this review, we reassess the required detector performance and survey relevant technologies. Fortuitously, the highly segmented detectors required to achieve good directionality also enable several fundamental and applied physics measurements. As a result, we comment on near-term challenges and how the field could be advanced.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

How Dynamic Time Warping Can Assist Conventional Cross-correlation

Waveform cross-correlation is a sensitive phase-matched filtering technique that can detect seismic events for nuclear explosion monitoring. However, there are outstanding challenges with correlation detectors, most notably a direct dependence on the completeness of the waveform template library. To ameliorate these challenges, we investigate how dynamic time warping (DTW) may make waveform correlation more robust. DTW analyzes the differences between two time series and attempts to “warp” one time series relative to another in a recursive manner. We apply DTW to synthetic earthquake and recorded explosion templates to expand the capability of correlation detectors. We explore what conditions (e.g., source, station distance, frequency bands) and/or DTW algorithms generate stronger correlation scores. We show that DTW performs well on noisy signals and can dramatically improve the cross-correlation coefficient between a template and data-stream waveform. We conclude with recommendations on how to utilize DTW in nuclear monitoring detection.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Searches for New Physics With Muon Conversion at Fermilab and Triboson Production at the LHC

We report on several efforts to search for physics beyond the standard model of particle physics at broad energy scales. The Mu2e experiment at Fermilab will search for charged lepton flavor violation via the muon to electron conversion process, which is suppressed in the Standard Model. Mu2e will be operated at a low energy, yet can probe New Physics at very high mass scales (O(1e3 - 1e4 ) TeV). At high energies, the CMS experiment at the CERN LHC continues to deliver an impressive suite of Standard Model measurements and limits on a variety of New Physics signatures. Mu2e is under construction and slated to collect its first physics data in the coming years. This thesis describes work done during the construction phase of Mu2e and focuses on two critical areas: magnetic field modeling and statistical analysis. We describe a novel method for field modeling which we validate using a simulated dataset representing the expected magnetic field in the Detector Solenoid. This method blends a standard least-squares fitting technique that utilizes physically motivated analytical model functions with a novel physics informed network that is constructed to obey Maxwell’s equations. We show the technique can model the field with an accuracy of 10−7 despite the presence of injected noise in the pseudo-measurements at the 10−5 level. We then present preliminary results of the calibration of 3D Hall probes at the sub-10−4 level. These probes will be used to directly measure the Mu2e Detector Solenoid magnetic field on a sparse grid; these measurements serve as the input to the field model fitting. Finally, we describe the first implementation of both an unbinned shape analysis and a Bayesian interpretation applied to Mu2e pseudo-data. Up to 20% tighter limits can be set by the shape analysis compared to a standard cut & count analysis. The AlCap experiment collected data at PSI in 2015 to measure several important quantities related to nuclear muon capture on an aluminum target, which is a significant background process for Mu2e. The neutron emission from muon capture can introduce background hits in the Mu2e detectors and can increase radiation damage in various elements of the apparatus. We present measurements of the neutron group fluence and mean neutron multiplicity for muon capture on aluminum nuclei. Finally, we discuss an analysis of triboson production at CMS using an Effective Field Theory framework. Standard Model triboson production, which was first observed at CMS in 2020, has a relatively small cross section and provides direct access to both anomalous triple gauge couplings and quartic gauge couplings. These couplings, interpreted in the Standard Model Effective Field Theory, are studied in the present work. We target the boosted regime where the background rate is low and yields are enhanced when dimension-6 and dimension-8 Wilson coefficients are non-zero. We do not observe an excess in the data and therefore set bounds on the Wilson coefficients. For dimension-6 coefficients the tightest observed (expected) bounds are set on cW /Λ2 where Λ is the mass scale of new physics; the bounds are [−0.13, 0.12] TeV−2 ([−0.12, 0.12] TeV−2 ) at 95% CL. The tightest bounds in dimension-8 are set on fT,0 / Λ4 ; the observed (expected) bounds at 95% CL are [−0.63, 0.69] TeV−4 ([−0.54, 0.62] TeV−4 ). Additional results are presented which include scenarios where multiple Wilson coefficients are non-zero, the application of signal model clipping to address unitarity violation in Effective Field Theories, and a novel template fit developed for easier reinterpretation of our results.

Kampa, Cole Erik [Northwestern U. (main)] (ORCID:0↗

Real-time Anomaly Detection for Liquid Argon Time Projection Chambers

We present a real-time anomaly detection framework for liquid argon time projection chambers (LArTPCs), targeting applications in particle physics experiments such as the Short Baseline Near Detector (SBND) or the future Deep Underground Neutrino Experiment (DUNE). These experiments employ detectors that generate and stream high-resolution but sparse images of neutrino and other particle interactions. Our approach utilizes anomaly detection with autoencoders, compressed through knowledge distillation (KD), to enable the detection of anomalous signals in the data through efficient inference on resource-constrained hardware. The framework is targeted for deployment on computing platforms equipped with field-programmable gate arrays (FPGAs), GPUs, or CPUs, allowing low-latency selection of relevant activity directly from the raw detector data stream. We demonstrate that our approach is suitable for the detection and localization of anomalously "high-multiplicity" activity, and outline promising applications for LArTPC online data filtering and triggering.

FOS: Physical sciences↗

A preliminary investigation into the electrodeposition and synthesis of radiopure Copper–Chromium alloys for rare-event physics detector systems

Current investigations into neutrinoless double beta decay and the direct detection of dark matter require increasingly sensitive detector systems that demand ultra-low background materials. These requirements have previously been attained using ultra-radiopure electroformed (EF) copper. However, pure copper possesses high ductility and relatively low strength, which necessitates the need for large amounts of material and extra care during fabrication to help minimize galling and mechanical failure. Furthermore, we investigate an alloying alternative to pure EF copper by examining low wt% copper chrome (Cu–Cr) solid solution alloys, with inquiries into alloy hardness, strength, and radiopurity. Alloyed Cu–Cr layered samples are shown to exhibit significantly increased hardness compared to EF copper, for example showing a 50% increase in exhibited hardness using less than 1% Cr by weight, with limited negative impact to the material’s radiopurity.

Background↗

Reducing ion diffusion at atmospheric pressure through intermingled positive and negative ions

Increasing ion molecule reaction times for ambient ionization techniques can increase sensitivity of detection. Longer reaction times result in an increase in analyte signal relative to the reactant ion signal, however with a subsequent decrease in the total ion intensity. This loss in the total number of ions reaching the detector limits the extent to which increased reaction time can improve detection in practical applications. In this study ion loss was measured using either electric fields or gas flow to control ion transit time. Ion transit times ranged from 40 ms to 8s, which resulted in ion densities ranging from 5 x 10 6 to 2 x 10 4 ions/cm 3 , respectively. These results provide insights into practical reaction time limitations or experimental boundaries when exploring sensitivity enhancements in ambient ionization. When exploring longer reaction times with an atmospheric flow tube coupled to a mass spectrometer (AFT-MS), an additional corona discharge ionization source of the same polarity was added in an attempt to increase total ion signal, but no improvement in signal was observed. This observation suggested that there was a maximum ion density being reached by the corona discharge that could not be increased by adding more of the same polarity ions. A hypothesis was that intermingling both polarities of ions would reduce ion loss and increase the measured ion signal. When two corona discharge sources—one each of positive and negative polarity—were used simultaneously in an AFT-MS, the total ion signal of either polarity measured by the MS was approximately double the current from a single corona discharge source. An increase in the negative ion signal was also observed when ~10 parts-per-trillion vapor levels of an explosive (RDX) were introduced. In this case both the nitrate reactant ions and the RDX signal more than doubled with the addition of a corona discharge source producing positive ions. When intermingling positive and negative ions, an increase in ion current was also observed when the AFT was coupled directly to a Faraday detector or to an ion mobility spectrometer. This was the first demonstration of interfacing the AFT to an IMS. The observations and developments from this work will help in creating more portable instruments with improved sensitivity for detection of chemicals.

47 OTHER INSTRUMENTATION↗

Search for R -parity violating supersymmetric decays of the top squark to a b -jet and a lepton in s = 13 TeV p p collisions with the ATLAS detector

A search is presented for direct pair production of the stop, the supersymmetric partner of the top quark, in a decay through an R-parity violating coupling to a charged lepton and a b-quark. The dataset corresponds to an integrated luminosity of 140 fb -1 of proton-proton collisions at a center-of-mass energy of $\sqrt{s}$=13 TeV collected between 2015 and 2018 by the ATLAS detector at the LHC. The final state has two charged leptons (electrons or muons) and two b-jets. The results of the search are interpreted in the context of a Minimal Supersymmetric Standard Model with an additional B -L gauge symmetry that is spontaneously broken. No significant excess is observed over the Standard Model background, and exclusion limits on stop pair production are set at 95% confidence level. The corresponding lower limits on the stop mass for 100% branching ratios to a b-quark and an electron, muon, or tau-lepton are 1.9 TeV, 1.8 TeV and 800 GeV, respectively, extending the reach of previous LHC searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Direct LiF imaging diagnostics on refractive X-ray focusing at the EuXFEL High Energy Density instrument

The application of fluorescent crystal media in wide-range X-ray detectors provides an opportunity to directly image the spatial distribution of ultra intense X-ray beams including investigation of the focal spot of free-electron lasers. Here the capabilities of the micro- and nano-focusing X-ray refractive optics available at the High Energy Density instrument of the European XFEL are reported, as measured in situ by means of a LiF fluorescent detector placed into and around the beam caustic. The intensity distribution of the beam focused down to several hundred nanometers was imaged at 9 keV photon energy. A deviation from the parabolic surface in a stack of nanofocusing Be compound refractive lenses (CRLs) was found to affect the resulting intensity distribution within the beam. Comparison of experimental patterns in the far field with patterns calculated for different CRL lens imperfections allowed the overall inhomogeneity in the CRL stack to be estimated. The precise determination of the focal spot size and shape on a sub-micrometer level is essential for a number of high energy density studies requiring either a pin-size backlighting spot or extreme intensities for X-ray heating.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗