Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector and experiment monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Future Lightning Instruments for Weather and Climate Monitoring From LEO

Lightning is not only a natural hazard, but it also holds information about physical processes at work in deep convection and influences atmospheric oxidants that modulate ozone and methane. Hence, spaceborne lightning observations are essential for monitoring extreme events and feedbacks in Earth’s climate system. Low-Earth orbiting (LEO) lightning mapping instruments established a 25-year record of global lightning activity and resulted in a wealth of studies that motivated its designation as an Essential Climate Variable by the World Meteorological Organization. Although geostationary observations of lightning have become increasingly available since 2017, LEO lightning mappers continue to serve critical needs given their unique vantage point and acceptance as a unifying reference for geostationary lightning mapper and ground-based global lightning datasets. At the close of 2023, the Lightning Imaging Sensor (LIS) will cease operations on the International Space Station, which introduces a critical gap in LEO-based monitoring of global lightning activity. To address this need, NASA is developing new lightning mapping technology that enables future LEO-based satellite missions. Existing LEO-based lightning mappers rely on narrowband optical emissions centered on 777.4-nm and detectors that capture 500 images per second to detect lightning both day and night. Lightning can also produce optical emissions in a narrowband centered on 337-nm without any corresponding emissions at the traditionally used near-infrared (NIR) wavelength. These near-ultraviolet (UV) emissions are associated with earlier stage electrical breakdown (e.g., streamers), may frequent intense regions of deep convective storms, and may be a significant source of nitrogen oxide production in the upper atmosphere. A new lightning mapping instrument called the CubeSat Lightning Imaging and Detection Experiment (CLIDE) is being designed at NASA Marshall Space Flight Center to use high-speed, scientific CMOS image sensors capable of detecting lightning’s transient optical emissions in the near-UV and NIR during both daylit and nighttime scenes. This will extend the record of global lightning activity and help pave the way for future small satellite missions that combine radio and optical lightning detectors to obtain novel three-dimensional maps of lightning on a global scale, which can revolutionize the way lightning is used to monitor weather and understand changes in climate.

lightning↗

Gamma ray monitoring of a AGN and galactic black hole candidates by the Compton Gamma Ray Observatory

The Compton Gamma-Ray Observatory's Burst and Transient Source Experiment (BATSE) has a powerful capability to provide nearly uninterrupted monitoring in the 25 keV-10 MeV range of both active galactic nuclei (AGN) and galactic black hole candidates (GBHC) such as Cygnus X-1, using the occultation of cosmic sources by the Earth. Since the Crab is detected by the BATSE Large Area Detectors with roughly 25(sigma) significance in the 15-125 keV range in a single rise or set, a variation by a factor of two of a source having one-tenth the strength of Cygnus X-1 should be detectable within a day. Methods of modeling the background are discussed which will increase the accuracy, sensitivity, and reliability of the results beyond those obtainable from a linear background fit with a single rise or set discontinuity.

Skelton, R. T.↗

Tools used in Space Radiation Operations

The goal of NASA's Radiation Health Program is to achieve human exploration and development of space without exceeding acceptable risk from exposure to ionizing radiation. The Space Radiation Analysis Group (SRAG) at NASA Johnson Space Center carries out this mission by following the philosophy of ALARA – As Low as Reasonably Achievable. SRAG utilizes a variety of tools to maintain awareness of space weather and to monitor the space radiation environment, both internal and external to the vehicle. SRAG develops and manages a wide variety of detectors that are located on the exterior and throughout the interior of the International Space Station and worn by crew. During Artemis I, SRAG provided detectors distributed within Orion’s interior and participated in the MARE experiment, which outfitted female phantoms with thousands of thermoluminescence detectors (TLD) and other dosimeters to better constrain the total dose accrued inside the human during a mission to the Moon. Motivated by the Artemis Exploration Class missions, SRAG and collaborators are developing forecasting capabilities for solar energetic particle (SEP) events and their biological impacts to crew. Tools that have come out of this work include the Acute Radiation Risk Tool (ARRT) and the SEP Scoreboards. This presentation will give an overview of the tools used in SRAG ops and currently under development to support our next steps in human space exploration.

space weather↗

Analysis of 127 Xe tracer measurements using a net counts method

A suite of measurement systems were deployed as part of the Physical Experiment 1 series of experiments, which involved detonating chemical explosives along with radionuclide tracers in an underground cavity, at the Nevada National Security Site (NNSS) in the United States. One of the radionuclide tracers, 127 Xe was released from the containment following the explosion and detected on a SAUNA Q B sampler situated approximately 3.5 km away. The system uses a beta-gamma coincidence detector system to measure fission product radioisotopes of xenon relevant to nuclear explosion monitoring. In this work we use the coincidence measurement data to analyse and interpret the results from the SAUNA Q B system, to calculate the measured 127 Xe activity concentration(s).

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Soft X-rays from the sunlit earth's atmosphere

Observations of soft X-ray emission from the sunlit earth atmosphere are presented and compared with the predictions of an earth albedo X-ray theory. The exact theory accounts for the flux of Thomson scattered solar X rays and fluorescently excited K X rays that arise following the absorption of incident X rays as a function of observing geometry. Observations were made at widely separated geometries with the two low-energy detectors of the A-2 experiment on the HEAO-1 satellite. Fitting of the model to the observed spectra results in values for the solar coronal temperature and emission measure that are in good agreement with expected values for the nonflaring sun, indicating that X-ray observations of the sunlit atmosphere may be a useful monitor of solar activity for satellites unable to view the sun directly. The total measured fluorescent line flux is also in agreement with calculations, although the N/O line ratio is not. X-ray fluorescence measurements from the sunlit atmosphere will thus be useful in monitoring atmospheric composition only to the extent that the total line counting rates depend upon the composition.

Mckenzie, D. L.↗

Environmental Radiation Measurements on MIR Station: Internal Experiment - Program 1

Environmental radiation levels on the Russian space station Mir are being monitored under differing shielding conditions by a series of six area passive dosimeters (APDs) placed at individual locations inside the Core and Kvant 2 modules, and by an External Dosimeter Array (EDA) to be-deployed on the exterior surface of the Kvant 2 module. Each APD and the EDA contains CR-39 plastic nuclear track detectors (PNTDs) for measurement of LET spectra and TLDs for absorbed dose measurements. Two of the missions, NASA-2/Mir-21 and NASA-3/Mir-22 have been completed and the six APDs from each mission returned to Earth from Mir. This report covers progress to date on the analysis of TLDs and PNTDs from these two missions. For NASA-2/Mir-21, average mission absorbed dose rates varied from 271 to 407 micro-Gy/d at the APDS. For NASA-3/Mir-22, average mission absorbed dose rates varied from 265 to 421 micro-Gy/d.

Benton, E. V.↗

Comparison of Modeled to Measured Spectra using MCNP and GADRAS to Benchmark and Contrast Modeling Limitations

The desire to improve nuclear material detection through portal monitors and other low resolution detectors has led to interest in benchmarking the performance of radiation transport codes. These codes can be used to generate a variety and quantity of spectra that may be cost prohibitive to measure directly. Particular characteristics of typical detection scenarios were isolated to compare the performance of radiation transport codes to laboratory experiments. These benchmark experiments were performed to validate simulations in a number of key areas. These experiments included high areal density configurations in both one- and three-dimensional configurations. In addition, off-angle measurements were conducted to investigate the impact of detector response assumptions on complex geometries, for example where an unknown source is not physically collocated with an apparent hot spot. Furthermore, by examining both simple shielding and backscatter configurations, isolation of the scatter emanating from the object and environmental background scatter contributions to the spectra could be elucidated. A series of experiments were performed in which the order of shielding layers and the thickness were evaluated to examine the ability of the simulations to address these variables. Experiments with increasing thickness of polyethylene around a neutron source also allows for examinations of the ability of the transport simulations to properly model n,γ reactions. Finally, depleted uranium (DU) measurements have more complicated spectra than the cobalt-60 and consequently allow for investigations into the ability of transport simulations to model self-shielding. In each case, the results of the experiments were compared to MCNP simulations to judge the performance of the code, as was done previously with GADRAS 18.7.9 simulations [7]. All of the benchmark measurements were taken with a liquid nitrogen cooled 140% high purity germanium (HPGe) detector with a bismuth collimator that had the front tin filter removed. The measurement location and detector configuration were subsequently used for all experimental configurations. The remainder of this report details the experimental measurements, Section 2 and the MCNP model, Section 3. Comparisons between the experimental results and MCNP-generated spectra are performed, Section 4. Section 5 compares the results obtained with MCNP with the previously reported results obtained with GADRAS [2]. Finally, Section 6 presents the conclusions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Satellite observations of upper atmosphere O3 and HNO3 from the Limb Infrared Monitor of the Stratosphere /LIMS/ experiment on Nimbus 7

The Limb Infrared Monitor of the Stratosphere (LIMS) experiment, launched on-board the Nimbus satellite, was designed to measure both day and night limb radiance which is used to infer upper atmosphere temperature profiles and chemical compound concentrations important in the study of ozone chemistry. The LIMS instrument is a six channel, limb scanning, thermal radiometer which uses HgCdTe detectors, cooled to approximately 64 K. Measurements include ozone, water vapor, nitrogen dioxide, and nitric acid. The ozone and nitric acid channels are centered at approximately 9.6 microns and 11.3 microns, respectively. Results from the channels are described with an emphasis on data validation. The O3 and HNO3 channels have demonstrated high measurement precision.

Russell, J. M., III↗

Characterization of microbial and chemical composition of shuttle wet waste with permanent gas and volatile organic compound analyses

Solid-waste treatment in space for Advanced Life Support, ALS, applications requires that the material can be safely processed and stored in a confined environment. Many solid-wastes are not stable because they are wet (40-90% moisture) and contain levels of soluble organic compounds that can contribute to the growth of undesirable microorganisms with concomitant production of noxious odors. In the absence of integrated Advanced Life Support systems on orbit, permanent gas, trace volatile organic and microbiological analyses were performed on crew refuse returned from the volume F "wet" trash of three consecutive Shuttle missions (STS-105, 109, and 110). These analyses were designed to characterize the short-term biological stability of the material and assess potential crew risks resulting from microbial decay processes during storage. Waste samples were collected post-orbiter landing and sorted into packaging material, food waste, toilet waste, and bulk liquid fractions deposited during flight in the volume F container. Aerobic and anaerobic microbial loads were determined in each fraction by cultivation on R2A and by acridine orange direct count (AODC). Dry and ash weights were performed to determine both water and organic content of the materials. Experiments to determine the aerobic and anaerobic biostability of refuse stored for varying periods of time were performed by on-line monitoring of CO2 and laboratory analysis for production of hydrogen sulfide and methane. Volatile organic compounds and permanent gases were analyzed using EPA Method TO15 by USEPA et al. [EPA Method TO15, The Determination of Volatile Organic Compounds (VOCs) in Ambient Air using SUMMA, Passivated Canister Sampling and Gas Chromatographic Analysis,1999] with gas chromatography/mass spectrometry and by gas chromatography with selective detectors. These baseline measures of waste stream content, labile organics, and microbial load in the volume F Shuttle trash provide data for waste subsystem analysis and atmospheric management within the ALS Project. Published by Elsevier Ltd on behalf of COSPAR.

NASA Center KSC↗

IDE spatio-temporal impact fluxes and high time-resolution studies of multi-impact events and long-lived debris clouds

During the first 12 months of the Long Duration Exposure Facility (LDEF) mission, the Interplanetary Dust Experiment (IDE) recorded over 15,000 total impacts on six orthogonal faces with a time resolution on the order of 15 to 20 seconds. When combined with the orbital data and the stabilized configuration of the spacecraft, this permits a detailed analysis of the micro-particulate environment. The functional status of each of the 459 detectors was monitored every 2.4 hours, and post-flight analyses of these data has now permitted an evaluation of the effective active detection area as a function of time, panel by panel and separately for the two sensitivity levels. Thus, total impacts were transformed into areal fluxes, and are presented here for the first time. Also discussed are possible effects of these fluxes on previously announced results: apparent debris events, meteor stream detections, and beta meteoroids in observationally significant numbers.

Mulholland, J. Derral↗

An all-sky X-ray monitor for the UK-5 satellite.

An X-ray imaging system using a pin-hole camera and a position sensitive proportional counter at the image plane has been designed for an all-sky X-ray monitor for UK-5 satellite. This high-sensitivity device with real-time coverage of the entire celestial sphere would aid in programming satellite maneuvers such that transient events in the X-ray sky could be investigated in detail by the other primary satellite experiments. Discussion of design criteria for the camera geometry, the position sensitive proportional detector, and electronics to handle the data is presented in this paper.

Desai, U. D.↗

A gas chromatographic air analyzer fabricated on a silicon wafer

A miniature gas analysis system has been built based on the principles of gas chromatography (GC). The major components are fabricated in silicon using photolithography and chemical etching techniques, which allows size reductions of nearly three orders of magnitude compared to conventional laboratory instruments. The chromatography system consists of a sample injection valve and a 1.5-m-long separating capillary column, which are fabricated on a substrate silicon wafer. The output thermal conductivity detector is separately batch fabricated and integrably mounted on the substrate wafer. The theory of gas chromatography has been used to optimize the performance of the sensor so that separations of gaseous hydrocarbon mixtures are performed in less than 10 s. The system is expected to find application in the areas of portable ambient air quality monitors, implanted biological experiments, and planetary probes.

Terry, S. C.↗

Tropospheric Formaldehyde Measurements from the ESA GOME Instrument

The Global Ozone Monitoring Experiment (GOME) was launched on the European Space Agency's ERS-2 satellite on April 20, 1995. GOME measures the Earth's atmosphere in the nadir geometry, using a set of spectrometers that cover the UV and visible (240-790 nm) at moderate resolution (0.2 nm in the UV, 0.4 nm in the visible), employing silicon diode array detectors. GOME takes some 30,000 spectra per day, obtaining full global coverage in three days. We directly fit GOME radiance spectra using nonlinear least-squares analysis to obtain column amounts of several trace species with significant tropospheric concentrations, including ozone (O3), nitrogen dioxide (NO2), sulfur dioxide (SO2), and formaldehyde (HCHO). Measurements of HCHO due to biogenic activity in the troposphere are presented here.

Chance, K.↗

BlueSTEAl: A pair of silicon arrays and a zero-degree phoswich detector for studies of scattering and reactions in inverse kinematics

BlueSTEAl, the Blue (aluminum chamber of) Silicon TElescope Arrays for light nuclei, has been developed to study direct reactions in inverse kinematics, as well as scattering and breakup reactions using radioactive ion beams. It is a detector system consisting of a pair of annular silicon detector arrays and a zero-degree phoswich plastic scintillator. For typical binary reaction studies in inverse kinematics, light ions are detected by the Si array in coincidence with heavy recoils detected by the phoswich placed at the focal-plane of a zero-degree magnetic spectrometer. The Si array can also be used to detect light nuclei such as beryllium and carbon with clear isotope separation, while the phoswich can also be placed at zero degrees without a spectrometer and used as a high-efficiency beam counting monitor with particle identification capability at the rate of up to ~5 × 10 4 particles per second. This paper reports on the capabilities of BlueSTEAl as determined by recent experiments performed at the Texas A&M Cyclotron Institute. Furthermore, the device is also anticipated to be used in future experiments at other radioactive ion beam facilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Monitoring the readout temperature in the ICARUS TPC (2023 Italian Students Program Final Report)

Being a Liquid Argon Time Projection Chamber (LAr-TPC) detector, ICARUS exploits a series of three parallel wire planes to measure and collect the ionization charge coming from an event inside the active volume. The wires are read out by A2795 custom boards, arranged in crates located on top of the two liquid Argon vessels. Each board is provided with two temperature sensors that allow temperature monitoring while the experiment is running: this is key in order to ensure data reliability and maintain hardware in safe conditions. Moreover, temperature-related problems may force unplanned shutdowns that result in losing valuable time for the experiment to run. In this work we are discussing the characterization of the ICARUS TPC board temperatures and the system we implemented in order to monitor them effectively. Among the tools used, Grafana results in a valid application for both displaying temperature data and sending alerts to the shifters whenever a pathological situation occurs.

42 ENGINEERING↗

Calorimeter calibration and performance for the Mu2e experiment

The Mu2e experiment at Fermilab will search for the charged lepton flavour-violating conversion of a muon into an electron, aiming to reach a sensitivity of $R_{\mu e} \sim 10^{-17}$, an improvement of four orders of magnitude over previous limits. To reach this goal, Mu2e will use an intense pulsed muon beam and a detector system composed of a high-precision straw tube tracker and a pure CsI crystal calorimeter. The calorimeter plays a crucial role in the experiment, as it provides particle identification capabilities that are necessary for background suppression. To perform its tasks, the detector must achieve an energy resolution better than 10% and a timing resolution below 500 ps for 100 MeV electrons. Cosmic-ray data and laser pulses are used to equalize the response of each channel, to calibrate the energy scale and to monitor the system's stability over time. This poster reports on the calibration and analysis techniques developed to ensure that the calorimeter requirements for precise energy and time measurements are met. Results for the calorimeter performance obtained during the commissioning phase will be discussed, and an overview of the current status in the Mu2e experimental hall will be presented.

Salamino, Sabrina [Frascati]↗

Advancing Tassel Detection and Counting: Annotation and Algorithms

Tassel counts provide valuable information related to flowering and yield prediction in maize, but are expensive and time-consuming to acquire via traditional manual approaches. High-resolution RGB imagery acquired by unmanned aerial vehicles (UAVs), coupled with advanced machine learning approaches, including deep learning (DL), provides a new capability for monitoring flowering. In this article, three state-of-the-art DL techniques, CenterNet based on point annotation, task-aware spatial disentanglement (TSD), and detecting objects with recursive feature pyramids and switchable atrous convolution (DetectoRS) based on bounding box annotation, are modified to improve their performance for this application and evaluated for tassel detection relative to Tasselnetv2+. The dataset for the experiments is comprised of RGB images of maize tassels from plant breeding experiments, which vary in size, complexity, and overlap. Results show that the point annotations are more accurate and simpler to acquire than the bounding boxes, and bounding box-based approaches are more sensitive to the size of the bounding boxes and background than point-based approaches. Overall, CenterNet has high accuracy in comparison to the other techniques, but DetectoRS can better detect early-stage tassels. The results for these experiments were more robust than Tasselnetv2+, which is sensitive to the number of tassels in the image.

54 ENVIRONMENTAL SCIENCES↗

Photoproduction of the b 1 (1235) Meson off the proton at E gamma = 6-12 GeV

The GlueX Experiment at Jefferson Lab directs a linearly polarized photon beam on a liquid hydrogen target surrounded by an almost hermetic detector. The experiment aims to study the meson spectrum in the light-quark sector and search for exotic spin-parity states predicted by lattice QCD calculations. The lightest exotic candidate is the π 1 meson, which is predicted to decay dominantly to b 1 π. In this thesis, we present efforts to characterize the ωπ 0 decay channel of the b 1 meson as precursor to an analysis of the sought-after π 1 exotic state. We present an introduction to the physics involved and an overview of the detector subsystems with a focus on the Barrel Calorimeter gain monitoring system, as part of the service work expected by the GlueX Collaboration. We discuss the data analysis method used and present two frameworks, for angular moments and partial waves analyses. Details of the simulation used to calculate the detector acceptance. A proof of concept partial wave analysis is presented along with experimental angular moments as first step to a full analysis of the angular distribution Our partial wave analysis indicates that both S- and D-waves are needed, in qualitative agreement with theoretical expectations. The cross-section of the omega π 0 channel is extracted to be of the scale of 1 μb in agreement with previous measurements. The differential cross-section indicates the presence of two production processes with p 1 = -5:24 ± 0:04 for 0:25 < -t < 0:95 GeV 2 ~c 2 and p 2 = -1:24 ± 0:05 for 0:95 < -t < 2:0 GeV 2 ~c 2 , which does not agree with results from previous experiments. The s-channel helicity conservation and helicity amplitudes of the b 1 meson are presented as additional experimental observables. Our results confirm that the b1 photoproduction process does not conserve s-channel helicity though they do not align with previous measurements. The helicity amplitude of the omega are extracted to be |F 1 | 2 = 0:3037 ± 0:0003 which does not agree with the expected value of a b 1 decay or results from a previous experiment. Future steps in all these analyses will be continued by a new graduate student in the group, culminating in a publication.

Foda, Ahmed↗