Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “density measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

CRIT II electric, magnetic, and density measurements within an ionizing neutral stream

Measurements from rocket-borne sensors inside a high-velocity neutral barium beam show a-factor-of-six increase in plasma density in a moving ionizing front. This region was colocated with intense fluctuating electric fields at frequencies well under the lower hybrid frequency for a barium plasma. Large quasi-dc electric and magnetic field fluctuations were also detected with a large component of the current and the electric field parallel to B(0). An Alfven wave with a finite electric field component parallel to the geomagnetic field was observed to propagate along B(0), where it was detected by an instrumented subpayload.

Swenson, C. M.↗

Ground-based detection of stratospheric ClO and average column density measurement over 17 days of observation

A very sensitive mm-wave heterodyne receiver of a type originally developed for radio astronomy is used in combination with a broadband filter bank spectrometer to detect and measure the 204-GHz rotational transition of stratospheric ClO. Data is acquired in the form of a dimensionless ratio and is converted to units expressing signal intensity. Computed line shapes are matched against the data for a comparison with theoretical stratospheric models and previous measurements. The ClO distribution in the stratosphere measured at 42 deg N latitude in early spring is significantly different from that expected based on existing theoretical models. There is much less ClO at latitudes below about 36 km than predicted, and average ClO column density found for 42 deg N is 20-30% less than that from existing balloon flight measurements at 32 deg N.

Dezafra, R.↗

A tensor density measure of topological charge in three dimensional nematic phases

A path-independent measure in order parameter space is introduced such that, when integrated along any closed contour in a three-dimensional nematic phase, it yields the topological charge of any line defects encircled by the contour. A related measure, when integrated over either closed or open surfaces, reduces to known results for the charge associated with point defects (hedgehogs) or Skyrmions. We further define a tensor density, the disclination density tensor D, from which the location of a disclination line can be determined. This tensor density has a dyadic decomposition near the line into its tangent and its rotation vector, allowing a convenient determination of both. The tensor D may be non-zero in special configurations in which there are no defects (double-splay or double-twist configurations), and its behaviour there is provided. The special cases of Skyrmions and hedgehog defects are also examined, including the computation of their topological charge from D.

36 MATERIALS SCIENCE↗

A tensor density measure of topological charge in three dimensional nematic phases

A path independent measure in order parameter space is introduced such that, when integrated along any closed contour in a three dimensional nematic phase, it yields the topological charge of any line defects encircled by the contour. A related measure, when integrated over either closed or open surfaces, reduces to known results for the charge associated with point defects (hedgehogs) or Skyrmions. We further define a tensor density, the disclination density tensor D, from which the location of a disclination line can be determined. This tensor density has a dyadic decomposition near the line into its tangent and its rotation vector, allowing a convenient determination of both. The tensor D may be nonzero in special configurations in which there are no defects (double-splay or double-twist configurations), and its behavior there is provided. The special cases of Skyrmions and hedgehog defects are also examined, including the computation of their topological charge from D.

36 MATERIALS SCIENCE↗

A New Plasma Radar Concept for Simultaneous Magnetic and Density Measurements

An innovative, compact 288GHz interferometer has been fabricated, tested, installed and successfully demonstrated on the LAPD-U magnetized plasma at UCLA. The system takes advantage of frequency modulated (FM) radar techniques to deliver a compact heterodyne system. In addition, the reflected power from the source is taken advantage of to eliminate the need for additional quasi-optical components. Electron density in LAPD-U plasma has recently been increased substantially thereby requiring a higher frequency/shorter wavelength interferometer to avoid deleterious refractive effects. This system satisfies those needs. The system uses a 96GHz varactor tuned Gunn oscillator which passes to a passive tripler. This tripler has ~3% conversion efficiency. The 288GHz radiation is then coupled to free space using a so-called dual-mode or Pickett horn. The output 288GHz beam is then coupled to an aspheric lens manufactured from low-loss, high-density polyethylene. This lens is employed to collimate the emerging beam. Small axial adjustment of the lens position can also be used to create a slowly focusing beam so as to optimize the measured signal. In addition, up-down or side-to-side adjustment of the lens can be utilized to steer the beam vertically or horizontally – again to optimize alignment. The propagating beam passes through a beam splitter and then through a water-free, bubble-free fused quartz window into the LAPD-U vacuum vessel. The beam-splitter is a thin sheet of G10 which reflects a small fraction of the incident power (~5 %) towards a zero-bias detector optimized for the frequency range from 220 to 300GHz. Note that waveguides at this frequency have dimensions of ~0.9mm x 0.45mm and so have very large conductive losses. This drives the use of quasi-optical propagation. The detector requires no DC bias and is very responsive (> 1V/mW into 1MΩ). Radiation is coupled to the detector via a similar lens-horn arrangement used for the launch. This reflected beam acts as the local oscillator or reference millimeter-wave beam for the detector. The remainder of the launched source beam then enters the LAPD-U vacuum vessel and passes through the plasma at the mid-plane until reaching the opposing port which is closed off with an aluminum flange. This flange is used as a mirror to retroreflect the incident 288GHz beam back along its path. The retroreflected beam exits the input port but does NOT couple directly into the zero-bias detector. Instead, the majority of the return power continues towards the 288GHz source. As mentioned above the transmitted beam enters the source a second time. This would appear undesirable. However, at these frequencies multipliers are highly non-linear elements which results in a significant portion of the return beam (~20%) re-emerging from the multiplier and horn and then coupling via the G10 beam-splitter to the zero-bias detector. This approach eliminated the need for a second quasi-optical beam-splitter. The system is extremely compact measuring approximately 28 inches x 20 inches. The above did not explain how heterodyne operation was achieved. As mentioned above the Gunn oscillator is able to be varactor tuned. This allows a low voltage to be applied to control the operating frequency of the Gunn oscillator. During heterodyne operation a sawtooth shaped voltage is applied to the varactor at 750kHz using an 80MHz Arbitrary Waveform Generator (AWG). This voltage changes the Gunn frequency linearly during the up-sweep which is then reset abruptly at the sawtooth crash to be immediately followed by another linear sweep. Passage through the 288GHz multiplier triples the frequency change experienced by the electromagnetic wave. These frequency changes are small – tens of megahertz. This FM radar approach results in the launched electromagnetic wave frequencies at the detector for the reference and plasma wave to be different. The approximately 10 ns delay propagation delay for the plasma beam results in the local oscillator and plasma beams NOT having an identical frequency – there is in fact a fixed difference frequency. The frequency tuning level of the Gunn oscillator is then adjusted so that there is ONE cycle of this difference frequency during each linear ramp. During the sawtooth crash or downward re-sweep this one cycle replays in reverse but on a very fast timescale. The process then repeats. Low-pass filtering eliminates the fast re-sweep to leave a pure sine wave heterodyne signal. When the plasma is present it introduces a phase delay in the sine wave (caused by the extremely small Doppler shift resulting from the optical path length change). Of course, to measure this phase change we need a reference. This is simply obtained from an arbitrary waveform generator which provides a synchronized output pulse train which again is low pass filtered to obtain a 750kHz sinusoidal voltage reference for the interferometer. The interferometer was installed on LAPD-U where it has worked reliably and has established that electron densities exceeding 1x10 13 cm -3 are routinely achieved. In addition, the system sensitivity was able to easily observe density fluctuation at frequencies up to 50kHz. FM Radar techniques have enabled a full demonstration of a compact, sensitive, high frequency (288GHz/1mm) heterodyne interferometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Formaldehyde Column Density Measurements as a Suitable Pathway to Estimate Near-Surface Ozone Tendencies from Space

In support of future satellite missions that aim to address the current shortcomings in measuring air quality from space, NASA's Deriving Information on Surface Conditions from Column and Vertically Resolved Observations Relevant to Air Quality (DISCOVER-AQ) field campaign was designed to enable exploration of relationships between column measurements of trace species relevant to air quality at high spatial and temporal resolution. In the DISCOVER-AQ data set, a modest correlation (r2 = 0.45) between ozone (O3) and formaldehyde (CH2O) column densities was observed. Further analysis revealed regional variability in the O3-CH2O relationship, with Maryland having a strong relationship when data were viewed temporally and Houston having a strong relationship when data were viewed spatially. These differences in regional behavior are attributed to differences in volatile organic compound (VOC) emissions. In Maryland, biogenic VOCs were responsible for approx.28% of CH2O formation within the boundary layer column, causing CH2O to, in general, increase monotonically throughout the day. In Houston, persistent anthropogenic emissions dominated the local hydrocarbon environment, and no discernable diurnal trend in CH2O was observed. Box model simulations suggested that ambient CH2O mixing ratios have a weak diurnal trend (+/-20% throughout the day) due to photochemical effects, and that larger diurnal trends are associated with changes in hydrocarbon precursors. Finally, mathematical relationships were developed from first principles and were able to replicate the different behaviors seen in Maryland and Houston. While studies would be necessary to validate these results and determine the regional applicability of the O3-CH2O relationship, the results presented here provide compelling insight into the ability of future satellite missions to aid in monitoring near-surface air quality.

Surface Conditions from Column and Vertically Reso↗

Absolute atomic hydrogen density measurements in an atmospheric pressure plasma jet: generation, transport and recombination from the active discharge region to the effluent

Atomic hydrogen (H) generated by atmospheric pressure radio frequency (RF) plasma jet is investigated by two-photon absorption laser induced fluorescence in a He-H 2 mixture. The reported time and spatially resolved H density profiles enable a detailed analysis of the species generation, transport and decay along the axis of symmetry of the jet. Here, the H density distribution for a continuous RF plasma jet corresponds well with the outcome of a Pseudo-1D plug flow model. In addition, RF power modulation has a strong effect on the H density in the active discharge region but has a negligible effect on the H density in the far effluent.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic storm of September 4, 1984 - A synthesis of ring current spectra and energy densities measured with AMPTE/CCE

Compositional studies of the equatorial distributions of ring current ions during the September 4, 1984 magnetic storm have been made possible by comprehensive energy, charge state, and mass coverage data from the Charge Composition Explorer satellite. An examination of ion spectra at an L value of about 4 on September 5, in the local evening sector, shows that energy density was dominated by protons, with O ions contributing about 27 percent at the peak of about 150 keV, while He ions contributed less than about 2 percent. September 6 ion spectra, taken during the recovery phase of the storm, indicate that ion densities at more than 20 keV had decreased markedly, and that the ring current energy density was primarily provided by protons.

Krimigis, S. M.↗

Effect of satellite potential on direct ion density measurements through the plasmapause

A simplified theory has been developed for calculating the effect of satellite potential on the ion current measured by an experiment such as an ion mass spectrometer or an ion trap. The theory is based on the use of a spherically symmetric Debye potential distribution in the sheath around the satellite and is particularly appropriate for use in regions where the Debye length is large, such as in the plasmasphere and magnetosphere. Ion data obtained from the ion trap on the Ogo 3 satellite during a pass through the plasmasphere show excellent agreement with the theory. The inferred ion densities from this analysis are as much as 1 order of magnitude different from what would be inferred from previous analyses.

Whipple, E. C.↗

Model Quality and Measurement Density Impact on Volt/Volt Ampere Reactive Optimization Performance

The operation of the utility grid is being reshaped by the continuous addition of distributed energy resources and advanced metering infrastructure, which challenge existing grid control strategies. Some utilities deploy advanced distribution management systems (ADMS) to assist with the consolidation of various applications and to augment situational awareness in response to the new power delivery dynamics. An ADMS is an integrated software platform that provides utilities with a way to enhance their reliability, control, and optimization with advanced applications, such as volt/VAR optimization (VVO). A VVO application could serve as a vehicle to deliver cost savings by providing the utility with a method to reduce rates by controlling the voltage and decreasing the energy usage in their service territory. Some utilities are reluctant to integrate an ADMS, because it is a significant investment that requires approval from the public regulatory commission and/or their customers. This paper evaluates the impact on VVO performance when using a lower-quality network model supplemented with additional measurements, which could provide an implementation for cost savings. The results show that a better model quality would provide the highest energy savings; however, some level of telemetry is necessary in all scenarios to prevent voltage exceedances.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Absolute Reactive Oxygen Species Densities in the Effluent of the COST Reference Source and Plasma-generated Atomic Oxygen Density Measurements in Liquid using TALIF

Reactive oxygen species are one of the most important species produced in a plasma. In particular the role of atomic oxygen and the hydroxyl radical OH has attracted many studies ranging from plasma medicine to plasma-driven biocatalysis and water treatment. Atomic oxygen and the hydroxyl radical OH are very reactive and react unselectively with many different substrates. The quantification of atomic oxygen and OH is challenging because of their reactivity and unknown reactions and rate constants.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗