Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “current energy converter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Towards constrained grid-forming control

Grid-forming converters are commonly envisioned to replace conventional synchronous generators as the cornerstone of future power systems. However, compared to synchronous generators, power converters and their power sources (e.g., renewable generation, energy storage) are subject to significant physical constraints (e.g., current limits, modulation limits). Grid-forming controls are commonly designed neglecting these constraints and subsequently augmented with limiters for a subset of constraints. In this work, we propose a systematic approach to constrained grid-forming control of two-level voltage source converters interfacing photovoltaics. We first formulate grid-forming control objectives and constraints of voltage source converters and photovoltaics in a one-step optimal grid-forming control problem. Next, we leverage primal-dual dynamics to obtain a dynamic feedback controller that approximates the solution of the one-step optimal grid-forming control problem. Finally, electromagnetic transient simulations are used to illustrate the results.

Gross, Dominic↗

A Single-Stage Multilevel AC-DC Bidirectional Converter With Natural Grid Harmonic Elimination

Generally, AC-DC converters have an AC-DC stage followed by a DC-DC stage. In these two stage approaches, the AC-DC stage is hard-switched, whereas the DC-DC stage is soft-switched. Therefore, the devices in the AC-DC stage can be switched only at tens of kHz to avoid excessive switching losses, thus limiting the bandwidth of the current control loop. Hence, the control of these converters with distorted grid voltages requires multiple harmonic compensation loops or other complex control algorithms in order for the grid currents to comply with IEEE standards. By integrating both the stages, the devices in the AC-DC stage can also be soft-switched, thus facilitating higher switching frequency, and thereby higher current control bandwidth. This paper proposes an integrated multilevel bidirectional AC-DC converter with improved control bandwidth and disturbance rejection. It is shown experimentally that the high bandwidth current control loop of the converter can reject grid harmonic current disturbances, without the need for any compensation loops or complex control techniques, and comply with IEEE standards.

30 DIRECT ENERGY CONVERSION↗

Recent Progress Made in the Development of High-Energy UV Transmitter

In this paper, the status of an all-solid-state UV converter development for ozone sensing applications is discussed. A high energy Nd:YAG laser for pumping the UV converter arrangement was recently reported. The pump is an all-solid-state, single longitudinal mode, and conductively cooled Nd:YAG laser operating at 1064 nm wavelength. Currently, this pump laser provides an output pulse energy of greater than 1J/pulse at 50 Hz PRF and a pulsewidth of 22 ns with an electrical-to-optical system efficiency of greater than 7% and a M(sup 2) value of approx. 2. The spatial profile of the output beam is a rectangular super Gaussian. This Nd:YAG pump laser has been developed to pump the nonlinear optics based UV converter arrangement to generate 320 nm and 308 nm wavelengths by means of 532 nm wavelength. Previously, this UV converter arrangement has demonstrated IR-to-UV conversion efficiency of 24% using a flash lamp pumped laser providing a round, flat top spatial profile. Recently, the UV converter was assembled and tested at NASA LaRC for pumping with the diode pumped Nd:YAG laser. With current spatial profile, the UV converter was made operational. Current efforts to maximize the nonlinear conversion efficiency by refining its spatial profile to match RISTRA OPO requirements are progressing.

Prasad, Narasimha S.↗

Multiport Control with Partial Power Processing in Solid-State Transformer for PV, Storage, and Fast-Charging Electric Vehicle Integration

This article proposes a multiport control method to enable partial power processing (PPP) in a medium-voltage (MV) multiport solid-state transformer (SST). MV multiport SSTs are promising in integrating low-voltage DC sources or loads such as solar photovoltaic, energy storage, and electric vehicles into smart grids without bulky line-frequency transformers. Compared to voltage-source SST, current-source (CS) SST features single-stage isolated bidirectional AC/AC, AC/DC, or DC/DC conversion using an inductive DC link. For a multiport CS SST, it is revealed in this article that the PPP capability can be enabled through the proposed control without extra hardware, different from the case of voltage-source converters where special hardware architecture is required for the PPP. With the PPP, most power exchange between LV ports is processed by only a fraction of the entire conversion stage, leading to reduced DC-link current, volume, loss, and improved efficiency. The proposed multiport PPP control scheme is analyzed to verify the advantages across a wide voltage and power range against conventional full power processing (FPP) multiport control, using the soft-switching solid-state transformer (S4T) with reduced conduction loss as an example. Comparative experimental results based on a SiC three-port S4T prototype verify the effectiveness of the proposed PPP scheme against the FPP scheme under both steady state and dynamic conditions. Here, the DC-link current reduction is measured to be more than 36%. Significantly, the proposed multiport PPP control scheme is generic and applicable to any hard-switching or soft-switching CS SSTs without extra hardware.

14 SOLAR ENERGY↗

Geomagnetic responses to the solar wind and the solar activity

Following some historical notes, the formation of the magnetosphere and the magnetospheric tail is discussed. The importance of electric fields is stressed and the magnetospheric convection of plasma and magnetic field lines under the influence of large-scale magnetospheric electric fields is outlined. Ionospheric electric fields and currents are intimately related to electric fields and currents in the magnetosphere and the strong coupling between the two regions is discussed. The energy input of the solar wind to the magnetosphere and upper atmosphere is discussed in terms of the reconnection model where interplanetary magnetic field lines merge or connect with the terrestrial field on the sunward side of the magnetosphere. The merged field lines are then stretched behind earth to form the magnetotail so that kinetic energy from the solar wind is converted into magnetic energy in the field lines in the tail. Localized collapses of the crosstail current, which is driven by the large-scale dawn/dusk electric field in the magnetosphere, divert part of this current along geomagnetic field lines to the ionosphere, causing substorms with auroral activity and magnetic disturbances. The collapses also inject plasma into the radiation belts and build up a ring current. Frequent collapses in rapid succession constitute the geomagnetic storm.

Svalgaard, L.↗

Fluid Flow Nozzle Energy Harvesters

Power generation schemes that could be used downhole in an oil well to produce about 1 Watt average power with long-life (decades) are actively being developed. A variety of proposed energy harvesting schemes could be used to extract energy from this environment but each of these has their own limitations that limit their practical use. Since vibrating piezoelectric structures are solid state and can be driven below their fatigue limit, harvesters based on these structures are capable of operating for very long lifetimes (decades); thereby, possibly overcoming a principle limitation of existing technology based on rotating turbo-machinery. An initial survey identified that spline nozzle configurations can be used to excite a vibrating piezoelectric structure in such a way as to convert the abundant flow energy into useful amounts of electrical power. This paper presents current flow energy harvesting designs and experimental results of specific spline nozzle/ bimorph design configurations which have generated suitable power per nozzle at or above well production analogous flow rates. Theoretical models for non-dimensional analysis and constitutive electromechanical model are also presented in this paper to optimize the flow harvesting system.

bimorph↗

Thermoradiative Conversion for Space Power Systems

The thermoradiative cell is a new method for converting heat energy to electrical power, first detailed by Strandberg in 2015. The cell is structurally similar to a photovoltaic cell, in that it is a p-n junction semiconductor device, but thermodynamically operates in the reverse direction, converting the thermal dark current into electrical power by utilizing the recombination radiation from thermally-generated electron hole pairs to radiate waste heat to space. This technology may have application for space missions in converting thermal energy produced by a radioisotope source or from a nuclear reactor into power. The power and efficiency can be calculated as a function of bandgap in the detailed-balance case (the Shockley-Queisser limit), in which all of the thermal emissivity of the cell is due to the recombination of thermally generated electron-hole pairs, and all other recombination losses are ignored. The current produced is directly proportional to the recombination radiation, and thus the more thermally generated pairs, the higher the current. The voltage is proportional to the external bias. These two constraints allow optimization of the optimum bias point for maximum power, and allow calculation of the efficiency at maximum power point. Unlike photovoltaic cells, the maximum power operating point is not the same as the maximum efficiency point, and higher efficiency can be achieved at a higher (negative) bias in the ideal case. Incorporating non-ideal losses, however, shifts the maximum efficiency point toward lower bias. Since a thermoradiative cell operates by radiating directly to space, the current produced by a themoradiative cells will increase with the Stefan-Boltzman radiative efficiency; roughly the fourth power of the temperature. Thus, in contrast to a photovoltaic converter, the power produced is highest at high operating temperatures. Likewise, in contrast to conventional thermal conversion, high radiator temperature increases, rather than decreases the efficiency. Thus, the thermoradiative conversion may fill a mission niche in which small radiator size is required. The basic operation will be summarized, applications to space power discussed, and the requirements for further research outlined.

Photovoltaic Cell↗

A Novel High-Performance Mission-Enabling Multi-Purpose Radioisotope Heat Source

Recent studies indicate science mission concepts targeting access to the sub-surface oceans of icy moons require ice-penetrating cryobots powered by advanced Radioisotope Power Systems (RPS). These systems would deliver waste heat for ice-melting in the range of 10 kW. Minimizing the transit time through the kilometers-thick ice shells to just a few years requires these RPS to utilize heat sources having a higher thermal energy volumetric density than the existing flight-qualified General-Purpose Heat Source (GPHS). A Compact Heat Source (CPHS)has been conceptualized in which the graphite impact shells(GIS) of the existing GPHS are rearranged in a hexagonal aeroshell containing seven GIS per module, as opposed to the standard two per module; offering a thermal energy density of 0.57 W/cm3versus 0.29 W/cm3 offered by the GPHS simply from the repackaging of Technology Readiness Level (TRL)9 subassemblies. Preliminary thermal modeling of the CPHS integrated into a notional radioisotope thermoelectric generator(RTG) structure further suggests that centerline temperatures are well within allowable limits during nominal operation. Given the need for the CPHS for a subset of missions, it is worth exploring the applicability of the CPHS for more general RTG purposes. We discuss herein how the CPHS may be implemented with either heritage or in-development thermoelectric converter technologies into a Next-Generation RTG concept. Due to a higher energy density, the legacy heat rejection fin arrangement must be modified to permit a sufficiently low cold-side temperature. Preliminary finite element analysis suggests fin-root temperatures can be kept as low as 520 K while allowing the generator to fit within the usable dimensions of currently available United States Department of Energy shipping containers. Such temperatures would certainly be compatible with the use of high temperature thermoelectric converter technologies.. A prime candidate is the heritage silicon-germanium (SiGe) unicouple, whose design could be adapted by approximately halving the leg-length, but without changes in hot and cold junction interfaces, which are features critical to the proven performance and reliability of these devices. The estimated Beginning of Life power for a SiGe-based CPHS-RTG using 12 CPHS for a thermal inventory of 10.5 kW is greater than 600 W under deep space operating conditions. Using higher performance segmented couples currently in development that are based on skutterudite,La3−xTe4and 14-1-11 Zintl thermoelectric materials in lieu of the SiGe unicouples would increase the power level to more than1 kW. The high specific power (We/kg) attribute of CPHS-RTGs found in this study could potentially enable Radioisotope Electric Propulsion (REP) mission concepts. Past NASA REP mission concept studies identified specific power needs in excess of 6to 8 We/kg. Based on a GPHS-RTG-like system configuration, we show that at fin root temperatures between 530 K and 570K (deep space environment), specific powers exceeding 10 We/kg are achievable using high performance segmented thermoelectric converters. The compact sizing and power density of the CPHS-RTG would constitute a significant step upgrade in specific power when compared to heritage GPHS-RTG (approximately5.1 We/kg) and off-the-shelf Multi-Mission RTG (approximately 2.6 We/kg).

Nesmith, Bill J.↗

Converter-Interfaced CHP Plant for Improved Grid-Integration, Flexibility and Resiliency

GE Research and its partner GE Renewables have proposed the use of an interface converter solution to increase the penetration of small to medium-sized CHP (1MWe to 20MWe) into distribution grids and improve their flexibility and grid support capability. Indeed, the proposed interface converter solution thanks to presence of the grid-ready inverter, allows to streamline the compliance to grid codes requirements, reduce the interconnection delays and costs and ultimately one of the main barriers for CHP adoption by commercial and industrial facilities. An additional benefit provided by the interface converter is the use of the grid-ready inverter for reactive power which eliminates the need of sizing the generator for that capability. These two benefits highly favor the economic feasibility of converter-interfaced CHP. Five user cases, each in one of the leading U.S states for CHP potential reported by the DOE in its estimation of the U.S Technical Potential of CHP, were selected to compare the economic performances of converter-interfaced CHP as compared with directly-coupled. They include a college campus in California, a hospital in New York, a water reclamation plant in Texas, a hotel in Minnesota, and a large office building in Pennsylvania. Results showed that, the presence of the interface converter allows to increase the return on investment (ROI) by 0.5 to 2 percentage points in most of the cases (4 of 5). Indeed, the interface converter by shortening the interconnection process allows to accelerate revenues while reducing interconnection costs. Added to the reduced cost of the required generator these savings trade favorably the capital cost of the converter. The analysis also showed that the profitability of the converter-interfaced CHP is highly sensitive to the energy price, interconnection delay, and converter cost. However, it appears that if the interface converter can shorten the interconnection process by at least 6 months, adopting this solution will be more economically viable than directly-coupled configuration in almost all the +23,000 sites of the U.S Technical Potential CHP. The evaluation of the benefits of a converter-interfaced CHP also showed that it enables higher ROI when coupled with other distributed energy resources (DER) such as battery energy systems (BESS) or solar photovoltaic (PV). Indeed, in those scenario, the grid-ready inverter included in the interface converter eliminates the need of separate inverters if DC-coupling is used. On the technical performance, it has been verified that the presence of the interface converter allows to reduce by 70% to 80% the CHP short-circuit contribution to grid faults. This not only reduces the mechanical and thermal stresses exposed to the CHP electrical components but also increases the grid hosting capacity which ultimately enables higher penetrations CHP. Another key benefit of the interface converter validated with hardware-in-the-loop simulations and testing is its superior capability for reactive power support. Indeed, using a power hardware testbed with two +700kW inverters configured in back-to-back, a microgrid controller and actual facilities loads it was demonstrated that the presence of the interface converter can help maintain a power factor near ~1 or regulate the voltage to ~1.0pu at the point of common coupling. This benefit can be highly valuable if in the future, due to higher penetration of renewable distributed energy resources (DER), utilities start billing demand charge based on kVA instead of kW as currently. It was also validated that converter-interfaced CHP can dispatch heat and power commands and seamlessly switch between the two modes while consistently controlling the power factor or voltage at PCC. Indeed, the power hardware testing showed that grid-connected converter-interfaced CHP can follow either the power or heat demand while maintaining a unity power factor at converter output. This research proved that the adoption of an interface converter as the solution for interconnection of CHP system into the distribution grid can greatly improve the economic feasibility of small to medium-sized CHP as well as the plant power quality, flexibility and resiliency. Additionally, it allows increased penetrations of CHP into the distribution grid, extends their grid support capability, and facilitates the integration of BESS and PV DER by streamlining their collocation within the same facilities. This ultimately provides an opportunity for commercial and small industrial facilities in the U.S to accelerate their energy transition thanks to the high energy efficiency of CHP systems and its reliable, flexible, and resilient microgrid operation when interconnected with an interface converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - Simulated Wave

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production using a single, simulated wave energy conversion device. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel Hydrogen. While the unit supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. For the wave energy, NLR used a wave energy converter model from PacWave. These devices can be equipped with accumulators and pressure relief values to smooth the power output by storing and releasing hydraulic energy. Using a peak power output of 10 MW, the model created two 25-minute profiles: one with and one without the accumulators and pressure relief valves. To down select the profile data from the native resolution of 20 Hz to 1 Hz, NLR took the mean of every 20 data points. NLR experimented with two simulated wave energy power plants: one that peaks at 10 MW, and one that peaks at 5 MW. These profiles were scaled for the physical 1.25 MW electrolyzer by multiplying the original profiles by one eighth and one quarter, respectively. The first profile matches the capacity rating of eight of the 1.25 MW electrolyzers, while the second matches four electrolyzers. Finally, NLR experimented with two settings for the electrolyzer power supply minimum and maximum current ramp rates (gain and slew): 200 and 400 amperes per second. The simulated profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wave electrolysis experiment and is formatted as follows: {technology}-{accumulator?}_{number of 1.25 MW electrolyzers connected}-{electrolyzer ramp rate in amperes/second} For instance, “wavePacWave-Noacc_4-400.zip” represents the 25 minute-long experiment using the PacWave’s wave energy converter model, equipped with no accumulator, connected to four 1.25-MW electrolyzers with their power supplies set to a maximum current ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wave power. An experiment, labeled “characterization_200.zip”, demonstrates the MC250 electrolyzer steady-state response with 30 minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all wave profiles combined into one dataset labeled "combined_wave_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis.

08 HYDROGEN↗

Imaging Gas Counters for X- and Gamma Ray Astronomy

Gas-filled detectors, such as proportional counters, have long been used in x-ray astronomy. They are robust, relatively easy to fabricate, and can provide large collecting areas with reasonable spatial and energy resolution. Despite coming of age in the 50's and 60's, their versatility is such that they are still planned for future missions. A vigorous development program, led mostly by the high energy physics community, has ensured continued improvements in proportional counter technology. These include multistep counters, microstrip technologies and optical avalanche chambers. High fill-gas pressures and the use of suitable converters permit operation up to 100s of GeV. The current status of imaging gas-filled detectors will be reviewed, concentrating on the lower energy region (less than 100 keV) but also briefly covering higher energy applications up to the GeV region. This review is not intended to be exhaustive and draws heavily on work currently in progress at MSFC.

Ramsey, Brian D.↗

Develop a Simulation Framework for Understanding Physico-Chemical Processes and Optimization of CHZ' Plastic Thermolyze Technology (CRADA Final Report)

Thermolyzer(TM) technology is a third-generation, multi-reactor, oxygen-free, low pressure, slow pyrolysis process. It has proven to be remarkably versatile in successfully processing all types of hydrocarbon waste. These include all seven types of plastics, tires, auto shredder residue, carpet, electronic waste, and composites. Working with the IACMI, Thermolyzer(TM) technology has recovered the glass and carbon fibers from wind turbine blades for reuse into new applications. Its primary output is a synthesis gas that is rich in H 2 , CH 4 , and small amounts of C 2-4 aliphatic hydrocarbons. Other components are CO and CO 2 . Three unique features set Thermolyzer(TM) apart from other pyrolysis systems: the syngas is clean enough to run in Siemens or Solar gas turbines or IC engines without fouling, clean, salable, byproducts are produced, and CO 2 emissions are lower than natural gas power plants. Research results have been obtained from an operating 7 ton/day facility. A 44 ton/day plant has successfully operated as noted above. The process works because it makes use of the recoverable embodied energy in the feedstock. Surprisingly, a pound of some plastics has the same recoverable energy content as a pound of gasoline. Thus, it is imperative to develop a process that economically converts scrap plastics (including ocean plastics) into energy and thereby conserve the non-renewable fossil fuels for future generations. The Thermolyzer(TM) technology can also be used to create liquid fuels like gasoline and diesel from hydrocarbon wastes. Because of the high hydrogen content of the synthesis gas, hydrogen can be recovered more inexpensively than the current solar or wind energy being used to electrolyze water. That hydrogen can be used for fuel cell powered vehicles or converted into ammonia for agriculture or as a hydrogen storage medium. Extension of this technology to other wastes such as tires, auto shredder residue or wood wastes would expand the circular economy.

36 MATERIALS SCIENCE↗

Characterizing in-stream turbulent flow for tidal energy converter siting in Cook Inlet, Alaska

Cook Inlet in Alaska is the most promising location for tidal energy development in the U.S. due to its significant tidal range of approximately 10 meters and high volume flux. The inlet's unique geometry and flow characteristics make it the most energetic tidal stream in the nation, with GW-scale potential energy capacity. With the growing interest in tidal energy converter (TEC) deployment in this area, we implemented a regional-scale, 3D hydrodynamic modeling framework to predict tidal current and turbulence characteristics that can assist TEC designers and project managers. We validated the model results extensively using various datasets collected with bottom-mounted acoustic Doppler current profilers and velocimeters. The comparison between the model outputs and observational data highlighted the effectiveness of the 3D FVCOM model and the Mellor-Yamada Level 2.5 Turbulence Model in accurately assessing macro-scale kinetic energy, turbulence intensity, and the production and dissipation rates at a prospective TEC site. Using two months of model simulation data, we examined the channel cross-section for TEC deployment, focusing on undisturbed power density and macro-scale turbulent properties. Further, our findings indicate that understanding the turbulence characteristics and flow properties can enhance Stage I/II resource characterization by identifying optimal locations for TECs and their layouts within the channel. Furthermore, we demonstrated that TEC designers can utilize macro-scale turbulence data from 3D coastal models as boundary conditions for other turbulence models, allowing for a more detailed resolution of the turbulence structure at TEC siting locations. Ultimately, this work emphasizes the importance of estimating flow and turbulence conditions in energetic systems to understand turbulent sites better and improve resource characterization.

16 TIDAL AND WAVE POWER↗

Time Delay of Wide Area Damping Control in Urban Power Grid: Model-Based Analysis and Data-Driven Compensation

Due to the rapid development of economies, large urban cities consume an increasing amount of energy and have a higher requirement for power quality. Voltage source converter based high voltage direct current (VSC-HVDC) is a promising device to transmit clean power from remote regions to urban power systems, while also providing wide area damping control (WADC) for frequency stabilization. However, the time-delay naturally existing in the VSC-HVDC system may degrade the performance of WADC and even result in instability. To address this issue, this paper develops a time-delay correction control strategy for VSC-HVDC damping control in urban power grids. First, a small signal model of WADC is built to analyze the negative impacts of time delay. Then, a data-driven approach is proposed to compensate for the inherent time delay in VSC-HVDC damping control. The extensive training data will be generated under various disturbances. After offline training, the long short-term memory network (LSTM) can be implemented online to predict the actual frequency deviation based on real-time measurements. Finally, the proposed method is validated through MATLAB-Simulink in a two-area four-machine system. The results indicate that the data-driven compensation has a strong generalization ability for random delay time constants and can improve the performance of WADC significantly.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Study of the generator/motor operation of induction machines in a high frequency link space power system

Static power conversion systems have traditionally utilized dc current or voltage source links for converting power from one ac or dc form to another since it readily achieves the temporary energy storage required to decouple the input from the output. Such links, however, result in bulky dc capacitors and/or inductors and lead to relatively high losses in the converters due to stresses on the semiconductor switches. The feasibility of utilizing a high frequency sinusoidal voltage link to accomplish the energy storage and decoupling function is examined. In particular, a type of resonant six pulse bridge interface converter is proposed which utilizes zero voltage switching principles to minimize switching losses and uses an easy to implement technique for pulse density modulation to control the amplitude, frequency, and the waveshape of the synthesized low frequency voltage or current. Adaptation of the proposed topology for power conversion to single-phase ac and dc voltage or current outputs is shown to be straight forward. The feasibility of the proposed power circuit and control technique for both active and passive loads are verified by means of simulation and experiment.

Lipo, Thomas A.↗

Photosynthetic biohybrid systems for solar fuels catalysis

Photosynthetic reaction center (RC) proteins are finely tuned molecular systems optimized for solar energy conversion. RCs effectively capture and convert sunlight with near unity quantum efficiency utilizing light-induced directional electron transfer through a series of molecular cofactors embedded within the protein core to generate a long-lived charge separated state with a useable electrochemical potential. Of current interest are new strategies that couple RC chemistry to the direct synthesis of energy-rich compounds. This Feature Article highlights recent work from our lab on RC and RC-inspired hybrid systems that capture the Sun's energy and convert it to chemical energy in the form of H2, a carbon-neutral energy source derived from water. Further, biohybrids made from the Photosystem I (PSI) RC are among the best photocatalytic H2-producing protein hybrids to date. Targeted self-assembly strategies that couple abiotic catalysts to PSI translate to catalyst incorporation at intrinsic PSI sites within thylakoid membranes to achieve complete solar water-splitting systems. RC-inspired biohybrids interface synthetic photosensitizers and molecular catalysts with small proteins to create photocatalytic systems and enable the spectroscopic discernment of the structural features and electron transfer processes that underpin solar-driven proton reduction. In total, these studies showcase the incredible scientific opportunities photosynthetic biohybrid research provides for harnessing the optimal qualities of both artificial and natural photosynthetic systems and developing materials that capture, convert, and store solar energy as a fuel.

14 SOLAR ENERGY↗

Tearing mode instability in a multiple current sheet system

The tearing mode and magnetic reconnection are studied for multiple current sheet systems by two-dimensional magnetohydrodynamic (MHD) simulations. Both the linear and nonlinear evolution of this process are anaylsed for laminar perturbations. The results illustrate the existence of a linear regime with a symmetric and antisymmetric mode and agree with previous analytic results (Otto and Birk, 1992). The nonlinear evolution shows a number of interesting new features and may explain some properties in corresponding studies of turbulent reconnection. For wavelengths larger than twice the current sheet separation the evolution of antisymmetric modes leads to an entire reconfiguration of the magnetic field and converts a major portion of the magnetic energy into kinetic energy. Antisymmetric modes with smaller wavelengths and symmetric modes are found to saturate. The influence of the value of the resistivity on the reconnection rate decreases in the nonlinear evolution, and the ratio of current sheet separation to wavelength seems to be of major importance. A comparion of the dynamics of periodic current sheets with the evolution of only two current sheets indicates that some of the results for the periodic system also apply to the evolution of only two interacting current sheets. The results are discussed with respect to observations of large-scale plasma and magnetic field reconfigurations in the magnetosheath and near the Earth's bow shock.

Yan, M.↗