Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “current control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

An Ultra-Fast Inrush-Current-Free Startup Method for Grid-tie Inverter without Voltage Sensors

This paper proposes an ultra-fast inrush-currentfree startup method for grid-tie inverters without voltage sensors and phase-locked loop (PLL). Traditionally, the grid-tie inverter needs the voltage measured from points of common couplings (PCC) to generate the phase angle via PLL for inverter pulsewidth- modulation (PWM) signals. The startup procedure is slow and inrush current occurs if the initial PWM does not match the unknown grid voltage well. This paper proposes a startup method that only uses measured inverter ac currents to generate the initial PWM by controlling the current to zero. The generated PWM pattern can be used to reproduce the real grid voltage regardless of the grid impedance. The zero-crossing points of the grid voltage are detected and then used for grid synchronization. The proposed startup procedure only needs a few cycles (16.67 ms/cycle) to reliably synchronize the inverter to the grid without any inrush current. Simulation and experimental results are presented to verify the effectiveness of this control strategy.

He, Yuchen↗

IBPSA Project 2 BOPTEST: An update on the test cases available in the framework for testing advanced control strategies in buildings

Project 2 develops software infrastructure, test cases, and extensions for the Building Optimization Testing Framework (BOPTEST) to address the expanding needs of building and urban energy system controls through open international collaboration. This paper provides an overview of the new test cases available as of BOPTEST version 0.7.1. Each test case is developed using open-source Modelica libraries and Spawn of EnergyPlus, enabling the creation of high-fidelity building models that incorporate envelope dynamics, Heating Ventilation and Air Conditioning (HVAC) systems, and explicit control representations. Currently, eight test cases are available, with five additional cases under development. These test cases cover a wide range of climates, building types, and HVAC systems. This paper compiles and summarizes test case descriptions, cites original manuscripts that developed them for a more detailed description, and reports baseline control performance metrics. Furthermore, two example applications are presented: one illustrating different levels of control, from supervisory to low-level, and another demonstrating how Model Predictive Control (MPC) solutions must be adapted from continuous to integer to control some building actuators.

Zanetti, Ettore↗

Circulating Current Reduction of Back-to-Back MMC with Advanced Grid-Support Functionalities for Medium-Voltage Applications

A Lyapunov energy function based circulating current reduction scheme for a back to back modular multilevel converter based system for a microgrid application has been proposed in this digest. In order to ensure no circulating or zero sequence currents within the modules, the dynamics from one leg of the converter to the other are evaluated. A Lyapunov energy function is then developed and utilizing the circulating current dynamics of the converter the overall control law is implemented. In this digest a decentralized hierarchical control architecture has been implemented for the main current control; where the outer loop or the central controller implements the higher level grid interconnection functions as per IEEE 1547-2018 standards and the inner loop based on synchronous reference frame implements the current control architecture. The inner loops' outputs are the commanded converter voltages either on either side which are augmented by the Lyapunov energy function based circulating current suppression architecture. To evaluate the efficacy of the overall system, the overall system is modeled around a 300kVA back to back SiC multilevel modular converter used as a direct-connected medium voltage (MV) grid intertie based on MATLAB/Simulink domain. Several important case studies are presented in this paper to prove the effectiveness of the proposed architecture. case study results are presented.

circulating current↗

Improved temperature control for measuring the humidity dependence of aerosol optical properties

Aerosols impact climate and cloud formation by their ability to take up water, which leads to changes in their optical properties. To better characterize the interactions of aerosol with water vapor, a humidification section has been added to the Cavity Attenuation Phase-shift Spectrometry (CAPS) instrument. The CAPS is a diode based method that provides simultaneous measurements of both aerosol total optical extinction and scattering in real-time. We are improving the humidity controlled sample line with new temperature controls. The current system suffers from particlelosses and poorly controlled humidity profiles, both of which were corrected for in the systems redesign. This improved wet-CAPS system has been integrated with a dry-CAPS to simultaneously measure the wet and dry aerosol optical properties. The two CAPS monitors were operated in a dry collection mode to ensure there were no biases between the instruments. Initial calibrations and data were collected to test the functionality of the dual CAPS system (wet + dry). The new two channel CAPS system improves our ability to measure the effects of humidity on aerosol optical properties.

58 GEOSCIENCES↗

Operation and Control of Soft Switching Solid State Transformer as a Virtual Synchronous Machine for Photovoltaic Application

Possibility for control and operation of a three-phase solid state soft switching transformer based as a virtual synchronous machine or synchronverter has been investigated in this paper. The soft switching solid state transformer is used as an interface between the ac grid and a photovoltaic power generation unit supported by a battery bank. The control architecture investigated in this paper is that of a synchronverter to achieve inertial support to the grid and local loads. The operation of the soft switching solid state transformer has also been investigated as a V S M during unbalanced/distorted grid voltage condition. Control objective to achieve oscillation free power transfer between the ports (photovoltaic, battery and grid) has been achieved. The presented architecture has been verified for several important case studies via numerical simulations based on MATLAB/Simulink domain.

grid current controller↗

Power Electronics as an Enabler of the Current and Future Grid: Control Instead of Copper

Power electronics are becoming more pervasive in the power system. Solar, wind and battery energy storage systems regularly connect to the grid using power electronic interfaces. Loads are also increasingly power electronic-based. These changes, coupled with the change in the power system's operating characteristics as more and more renewable energy is integrated into the power system, offer a challenge to power electronic and power system engineers alike - how do we design and operate the power system moving forward?

direct connect↗

Solid State Transformer Architecture and Control Compensation for Common Mode Currents

A high-altitude electromagnetic pulse (HEMP) or similar geomagnetic disturbance (GMD) has the potential to impact the operation of large-scale electric power grids. By introducing low-frequency common-mode (CM) currents, these events can degrade the performance of critical system components, such as large power transformers by introducing CM currents which can lead to magnetic saturation of the transformer core. In this work, a solid-state transformer (SST) is developed to replace susceptible equipment and improve grid resiliency by safely absorbing these CM disturbances. This device will be referred to as a common-mode solid-state transformer (CM-SST). An SST architecture based on a four-legged AC/DC converter is developed. This architecture enables active control of CM signals without disturbing the AC voltages or the real and reactive power delivery capabilities. A system-level model of this architecture is created, and time-domain simulations are performed to evaluate the SST’s performance in response to simulated CM disturbances. A control strategy for mitigating CM current is also investigated. Hamiltonian surface shaping and power flow control (HSSPFC) is used to design a nonlinear controller for the SST’s output inverter. The objectives of the controller are to suppress CM-induced AC current offsets and regulate AC currents to desired setpoints. Nonlinear system analysis is applied to design and validate the controller. Two cases are tested: (a) the proposed four-leg inverter and (b) a standard three-leg inverter. The results show that the proposed controller rapidly mitigates CM disturbances while maintaining high-quality AC current waveforms in the four-leg configuration. Finally, the hardware performance of an SST prototype is evaluated. In particular, the ability of the SST to safely redirect and absorb CM currents is demonstrated, showing how it can protect neighboring conventional transformers in the system. The study confirms that appropriate control laws allow the SST to protect both itself and adjacent transformers during a HEMP or GMD event.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Engineered current-density profile diode laser

The present technology can be used to control the current injection profile in the longitudinal direction of a high-power diode laser in order to optimize current densities as a function of position in the cavity to promote higher reliable output power and increase the electrical to optical conversion efficiency of the device beyond the level which can be achieved without application of this technique. This approach can be utilized, e.g., in the fabrication of semiconductor laser chips to improve the output power and wall plug efficiency for applications requiring improved performance operation.

Leisher, Paul O.↗

Engineered current-density profile diode laser

The present technology can be used to control the current injection profile in the longitudinal direction of a high-power diode laser in order to optimize current densities as a function of position in the cavity to promote higher reliable output power and increase the electrical to optical conversion efficiency of the device beyond the level which can be achieved without application of this technique. This approach can be utilized, e.g., in the fabrication of semiconductor laser chips to improve the output power and wall plug efficiency for applications requiring improved performance operation.

Leisher, Paul O.↗

Switched low-dropout voltage regulator

High-resolution switched digital regulators are disclosed having fast cross corner and variable temperature response, with constrained ripple. The strength of the power transistors utilized by the regulator are adjusted to control the current delivered to the load. The regulators utilize a slow control loop in parallel with a primary fast switching loop. The slow loop uses the switching signal of the primary loop to estimate the load current and set the power transistor size accordingly.

Kudva, Sudhir Shrikantha↗

Critical Clearing Time for Droop-Controlled Grid-Forming Inverters With Circular Current Limiting and Virtual Impedance Current Limiting

The critical clearing time is a crucial parameter for assessing the large-signal stability of grid-forming (GFM) inverters. Variations in current limiters can significantly impact an inverter's transient behavior during large disturbances. Here, this letter introduces a method based on the power-angle relationship to evaluate the fault recovery of a droop-controlled GFM inverter under a three-phase bolted fault scenario, considering both the circular current limiter and the virtual impedance method. High-fidelity simulations validate the accuracy of the proposed formulas in estimating the critical clearing time of the GFM inverter.

42 ENGINEERING↗

Seeding the explosion of a high-current-density conductor in a controlled manner through the addition of micron-scale surface defects

Inhomogeneities in a current-carrying conductor promote non-uniform heating and expansion through the complex feedback between current density, electrical resistivity, Ohmic heating, temperature, and hydrodynamics. Three-dimensional-magnetohydrodynamic (3D-MHD) simulations suggest that μm-scale resistive inclusions or voids seed local overheating and through hydrodynamic explosion generate continuously growing craters which become several times larger than the initial perturbation. The ejected mass is the genesis of an electrothermally driven plasma filament which develops at lower current than plasmas on uniform surfaces adjacent to the defect. This result suggests that 1D or even 2D treatments are largely inadequate for detailed prediction of plasma formation. To test computational predictions, z-pinch experiments driven to 1 MA studied ultra-high-purity aluminum rods which were then machined to include pairs of quasi-hemispherical voids or “engineered defects (ED)” on the current-carrying surface. ED are the dominant current-density perturbation and reproducibly drive local overheating which can be compared with 3D-MHD simulation. Data from high-resolution-gated imagers of visible surface emissions confirm many simulation predictions, including the surface topography of local overheating, and the propensity for neighboring ED to prematurely source plasmas which then connect to form a plasma filament. Results also provide conditional support of theory which suggests heating similarity; that is, heating is independent of ED size for geometrically scaled ED.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Matched Guiding and Controlled Injection in Dark-Current-Free, 10-GeV-Class, Channel-Guided Laser-Plasma Accelerators

Here we measure the high-intensity laser propagation throughout meter-scale, channel-guided laser-plasma accelerators by adjusting the length of the plasma channel on a shot-by-shot basis, showing high-quality guiding of 500 TW laser pulses over 30 cm in a hydrogen plasma of density n 0 ≈ 1 X 10 17 cm -3 . We observed transverse energy transport of higher-order modes in the first ≈ 12 cm of the plasma channel, followed by quasimatched propagation, and the gradual, dark-current-free depletion of laser energy to the wake. We quantify the laser-to-wake transfer efficiency limitations of currently available petawatt-class lasers and demonstrate via simulation how control over the laser mode can significantly improve beam parameters. Using 21.3 J of laser energy, and triggering localized electron injection, we observed electron bunches with single, quasimonoenergetic peaks up to 9.2 GeV with charge extending beyond 10 GeV.

43 PARTICLE ACCELERATORS↗

Positive-Sequence Modeling of Droop-Controlled Grid-Forming Inverters for Transient Stability Simulation of Transmission Systems

Here, this paper describes a positive-sequence model to represent two widely reported droop-controlled grid-forming inverters for bulk power systems simulation study. Methods of how to develop the equivalent voltage source behind impedance to represent inverters with and without inner control loops, modeling of P-f and Q-V droop controls, active and reactive power limiting modeling, and modeling of fault current limiting controls are described in detail. The model is implemented in commercially available positive-sequence simulation tools and compared with detailed electromagnetic transient models in both a single-grid-forming-inverter infinite-bus system and a modified IEEE 39-bus system. Finally, the model is tested on the full US Western Electricity Coordinating Council (WECC) system. Study results show that the model has a good level of accuracy compared to the detailed EMT models, and at the same time also achieves a high computational efficiency, which is suitable for the bulk power system simulation study.

42 ENGINEERING↗

Developing and Implementing New Waste Chemistry Controls for Hanford's Double-Shell Tanks - 20041

Waste chemistry controls for the Hanford double-shell tanks (DSTs) were established in the 1980's in response to tank failures caused by stress corrosion cracking (SCC) at the Savannah River Site (SRS). The controls were established based on a combination of SRS chemistry limits and corrosion testing results. Conditions in the Hanford DSTs have changed over time, with the temperature in the majority of the DSTs dropping below 50 deg. C. Testing indicated that the original chemistry control specification and SCC testing performed in 2010 did not protect against pitting corrosion mechanisms - what is believed to have caused the failure of tank 241-AY-102. New waste chemistry controls are necessary to protect the DSTs from both SCC and pitting corrosion. Savannah River National Laboratory (SRNL), with input from the Tank Integrity Expert Panel (TIEP) Corrosion Subgroup (CSG), performed a statistically based investigation of nitrate and halide ion induced pitting corrosion. The investigation was intended to develop a comprehensive waste chemistry envelope that minimizes the risk of both SCC and pitting caused by halide and nitrate ions. The waste chemistry envelope needed to be robust enough to address future waste retrieval and process changes which could significantly change the waste composition of the DSTs. The experimental design allowed the statistically significant ions and their effect on pitting corrosion to be determined. SRNL developed the 'pitting factor' which is an empirical relationship between the statistically significant inhibitive species (hydroxide, and nitrite), and pitting inducing species (nitrate, chloride, and fluoride). The coefficients are weighted factors that show the degree of influence the species have on the propensity for pitting. New waste chemistry control limits were recommended by SRNL, and concurred with by the TIEP CSG, that incorporated the pitting factor along with other limits. The controls developed to reduce the risk of pitting corrosion were evaluated to determine if they also protected against SCC. Hundreds of test results were reviewed and compared against the proposed limits. With the exception of one test result, instances where cracking was observed corresponded to chemistry that was outside of the proposed limits - indicating that the chemistry controls developed for pitting also adequately addressed SCC concerns. Existing tank composition estimates were evaluated against the new chemistry controls - three current tank chemistries are suspect, and may not meet the new chemistry control requirements. These included the interstitial liquid (liquid associated with solids) of DSTs 241-AN-102, 241-AN-106, 241-AN-107, and 241-AY-101. Measures are ongoing to evaluate the tanks with the suspect chemistry. These include varying combinations of: performing additional evaluations (history of use, modeling); DST specific laboratory testing; and, pursuing core samples of the DSTs. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗