Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “controlled humidity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Microphysics Dominates Sub‐Cloud Rain Evaporation in Trade Cumuli Over Barbados

This study investigates the microphysical and thermodynamic influences on North Atlantic trade-cumulus rain evaporation in the sub-cloud layer over Barbados from January to November 2020. Using radar observations and a 1-D model, the results reveal that microphysical properties, namely geometric mean diameter (D g ) and raindrop concentration, primarily control evaporation processes under conditions of limited thermodynamic variability. Thermodynamic factors like cloud base height and relative humidity exert a smaller influence due to their narrow observed ranges. Small D g leads to rapid increases in rain evaporation fraction (REF), as small drops evaporate completely, while larger D g yields slower, more gradual REF changes. Frequent weak-rain cases reduce the mean evaporation flux, whereas infrequent intense-rain events substantially enhance it. These findings highlight the pivotal role of microphysical variability in shaping sub-cloud evaporation in this trade cumulus regime, while thermodynamic effects may be more important in other environments.

54 ENVIRONMENTAL SCIENCES↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AP Tank Farm Exhauster Slipstream (Volume 1)

Washington River Protection Solutions (WRPS) tested four types of chemical cartridges for use in air-purifying respirators (APR) and powered air-purifying respirators (PAPR). These tests were undertaken to determine the period of time that the cartridges would provide adequate performance1 for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the Hanford AP tank farm exhauster slipstream. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing commonly is applied in situations where mixtures of COPCs exist and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge testing on a slipstream from the Hanford AP tank exhauster was conducted on March 23-24, 2018. This testing focused on both APR and PAPR cartridges. Previous testing of APR cartridges was conducted on the AP exhauster in June of 2016. However, an AP exhauster upgrade was completed in September 2016. In the most recent testing, slipstream vapors from the new AP exhauster were fed to two respirator cartridge test stands, one for the PAPR respirator cartridges and the other for the APR respirator cartridges. Both the APR and PAPR test stands were developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed on separate days using the APR cartridge test stand. Multipurpose PAPR cartridges—MSA OptiFilter TL (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (3M Company, Maplewood, Minnesota)—were also tested consecutively over the same two days as the APR cartridge tests, using the PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and the samples then were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of Air-Purifying Respirator (APR) Cartridge Performance Testing on Hanford Tanks SX-101 and SX-104 (Vol.1)

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air-purifying respirators to determine the period of time that the cartridges would provide adequate performance1 to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the headspaces of Hanford tanks SX-101 and SX-104. The Occupational Safety and Health Administration (OSHA) considers cartridge testing a valid approach for establishing cartridge change schedules.2 Testing is commonly applied in situations where mixtures of COPCs exist and where other approaches such as manufacturer recommendations and modeling are less reliable. The tests were designed and conducted to ensure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from June 16-17, 2017, and June 23-24, 2017, using headspace vapors from Hanford tank SX-104 and Hanford tank SX-101, respectively. Headspace vapors under static conditions were fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina), were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and subsequently were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on Hanford Tanks BY-108 and BY-110 Volume 1

Washington River Protection Solutions (WRPS) tested four types of chemical cartridges for use in air-purifying respirators (APR) and powered air-purifying respirators (PAPR). These tests were undertaken to determine the period of time that the cartridges would provide adequate performance for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the headspaces of Hanford BY-108 and BY-110 waste storage tanks. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing commonly is applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge tests were conducted over two days from February 23-25, 2018, using headspace vapors from Hanford tanks BY-108 and BY-110. Headspace vapors from the BY-108 tank were fed to the PAPR respirator cartridge test stand, while vapors from the BY-110 headspace were fed to the APR respirator cartridge test stand. Both the APR and PAPR test stands were developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Two different cartridges were assessed on each tank. Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed for vapors from BY-110 using the APR cartridge test stand. Multipurpose PAPR cartridges—MSA OptiFilter TL (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (3M Company, Maplewood, Minnesota)—also were assessed for vapors from BY-108 over the same two days using the PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and the samples then were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AX Tank Farm Exhauster Slipstream Volume 1

Washington River Protection Solutions (WRPS) conducted tests of four types of chemical cartridges for air-purifying respirators (APR) and powered air-purifying respirators (PAPR) to determine the period of time the cartridges would provide adequate performance1 for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the Hanford AX tank farm exhauster slipstream. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing a cartridge service life. Testing is applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge testing using vapors from a Hanford AX tank farm exhauster slipstream was conducted from August 25–27, 2017. Vapors from the exhauster slipstream were fed to two respirator cartridge test stands developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Four different cartridges were assessed. Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed on separate days using an APR cartridge test stand. Multipurpose PAPR cartridges—MSA-TL (TL1) (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR57 (TL2) (3M Company, Maplewood, Minnesota)—also were tested over the same two days using a separate PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on Hanford Tanks SX-101 and SX-104 Volume 1

Washington River Protection Solutions (WRPS) conducted tests using two types of chemical cartridges for use in powered air-purifying respirators (PAPR) to determine the period of time that the cartridges would provide adequate performance for PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the headspaces of Hanford tanks SX-101 and SX-104. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from June 16-17, 2017, from headspace vapors from Hanford tank SX-101 and from June 23-24, 2017, from Hanford tank SX-104. Headspace vapors were fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose high-efficiency PAPR cartridges, MSA-TL (TL1) (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (TL2) (3M Company, Maplewood, Minnesota) were assessed on separate days. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on the 702-AZ Primary Exhauster for the Hanford AY/AZ Tank Farms during a Waste-Disturbing Event

Washington River Protection Solutions (WRPS) conducted tests using two types of chemical cartridges for use in air-purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the 702-AZ Primary Exhauster for the Hanford AY-AZ tank farms. Unlike prior cartridge testing on the 702-AZ Primary Exhauster, the recent tests were performed during a waste-disturbing event. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from February 10–11, 2017, on a slipstream from the 702-AZ exhauster fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina), were assessed on separate days. Sample media (sorbent tubes) and canisters (e.g., Summa) sampling were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Psychrometric Analysis for New NuMI Evaporator Weather Station

Tritium (H-3) is a weakly radioactive isotope of hydrogen and is a byproduct of accelerator operations at Fermi National Accelerator Laboratory (Fermilab). The Neutrinos at the Main Injector (NuMI) target produced tritiated condensate exhausted via the MI-65 building evaporators. Re-condensation of tritium evaporate was observed on the MI-65 rooftop, on nearby buildings, and on the surrounding grounds due to inefficiency of the existing evaporator system. A new evaporator system is being designed to eliminate re-condensation, and psychrometric data (temperature, humidity and dew point) plays a vital role in determining the location of a weather station to control the new evaporator system.

Alvarado-Anderson, Chase↗

Analysis of Respirator Cartridge Performance Testing on a Hanford AW Tank Farm Exhauster Slipstream

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air-purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the exhauster for the Hanford AW tank farm. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service-life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from September 23-25, 2016, on a slipstream from the AW exhauster, under static conditions fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina), were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

54 ENVIRONMENTAL SCIENCES↗

The physics of desiccation cracks 1: Ductile fracturing and dependence on relative humidity

Ductile deformation is ubiquitously found in the shrinkage of geomaterials. The existence of ductility requires elastoplastic mechanics when analyzing the structure deformation under external stress. Here, in this work, we explore the physics of ductile fracturing based on the results from desiccation experiments and triaxial tests. By using the digital image correlation (DIC) method to generate the strain maps of samples undergoing desiccation cracking under different relative humidities, we obtain results showing the previously postulated Cnoidal Wave ductile failure patterns propagating under atmospheric condition-controlled crack velocities. We then correlate these observations with rate-dependent plasticity models calibrated through triaxial tests undergoing several unloading–reloading cycles and velocity stepping. This work demonstrates the necessity to consider ductility in soil cracking, indicating that the formation of crack patterns in soil desiccation is a slow and predictable process.

58 GEOSCIENCES↗

Stereo Camera Deployment in Support of TRACER (Field Campaign Report)

An improved understanding of the salient environmental controls on cloud formation, evolution, and eventual dissipation is critical to address ongoing challenges with cloud process and parameterization representations in global climate and Earth system models. One goal for the recent U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s Tracking Aerosol Convection Interactions Experiment (TRACER) campaign was to collect a comprehensive data set that enabled such convective cloud process studies and key demonstrations for those controls that influenced cloud life cycle (i.e., aerosols, thermodynamics) in the Houston, Texas region. To help accomplish this, ARM instrumentation during TRACER was tasked with tracking a large number of individual, isolated convective cells – and to follow the evolution of these cells at high spatiotemporal resolution to characterize changes in cloud dynamic and microphysical properties. Since Houston experiences a range of convective clouds, it was known that the standard ARM Mobile Facility (AMF) instruments may not be sufficient to completely document initiating, transient, or dissipating low- or shallow-cloud behaviors that were also expected during this campaign (in terms of sensitivity, resolution, and/or operational availability). As one partial solution, a supplemental stereo camera deployment (this sub-campaign) was requested to augment the ARM AMF instrumentation to better address shallow and shallow-to-deep transitional types of cloud process drivers during TRACER (ARM stereo cameras for clouds [STEREOCAM]; Romps and Öktem 2018). The primary scientific focus was the relationships between cloud properties and the ambient conditions, which points to several key TRACER science questions including: ‘What is the relationship between cloud size or updraft intensity to the environmental wind shear and/or humidity?’ Overall, the ARM TRACER stereo camera deployment demonstrated unique effectiveness in observing a wide range of critical shallow, congestus, and transitioning or time-evolving cloud characteristics. The data sets from these cameras include information on the clouds' horizontal dimensions, elevations, and depths, while also enabling potential products for cloud initiation and dissipation rates, and vertical velocities. Stereo cameras simultaneously inform on cloud life cycle stage and spatial properties such as cloud fractional coverage, which should provide complementary information for ARM users when combined with TRACER cloud radars, lidar, and/or other profiling sensors. Moreover, camera products offer large-eddy simulation (LES),-scale-appropriate cloud coverage, depth, and spatial variability estimates, while opening additional avenues to challenge difficult process questions on cloud updrafts/entrainment and their covariability with environmental controls such as wind shear and humidity.

47 OTHER INSTRUMENTATION↗

A chemo-mechanical model for describing sorption hysteresis in a glassy polyurethane

Abstract Hysteretic sorption and desorption of water is observed from 0 to 95% relative humidity and 298–333 K on a glassy polyurethane foam. It is postulated that sorption-induced swelling of the glassy polyurethane increases the concentration of accessible hydrogen-bonding adsorption sites for water. The accessibility of sites is kinetically controlled due to the restricted thermal motions of chains in the glassy polymer, causing a difference in accessible site concentrations during sorption and desorption. This discrepancy leads to hysteresis in the sorbed concentrations of water. A coupled chemo-mechanical model relating volumetric strain, adsorption site concentration, and sorbed water concentration is employed to describe water sorption hysteresis in the glassy polyurethane. This model not only describes the final mass uptake for each relative humidity step, but also captures the dynamics of water uptake, which exhibit diffusion and relaxation rate-controlled regimes.

36 MATERIALS SCIENCE↗

Long-term ultrasonic monitoring of concrete affected by alkali-silica reaction

This article presents continuous monitoring results of alkali-silica reaction (ASR) development in concrete specimens for over 400 days using ultrasonic testing and expansion measurements. Eight concrete specimens with nonreactive aggregate (Control), reactive coarse aggregate, and reactive fine aggregates were cast with two reinforced confinement conditions. The specimens were conditioned in an environmental chamber with high temperature and humidity (38°C and 90% relative humidity) to accelerate the ASR development. A multichannel ultrasonic monitoring system was developed to collect ultrasonic signals automatically, and the expansions in three directions were measured periodically. Results showed that the relative velocity change could detect the ASR initiation in all reactive specimens and show a correlation with expansion in the early stage. However, these correlations are inconsistent for different ASR specimens, and the velocity change becomes less sensitive to ASR damage in the late stage (after 300 days). Irrecoverable velocity drop was observed during every chamber shutdown period, especially in specimens with higher levels of ASR damage. This phenomenon suggests that the nonlinear ultrasonic response caused by the ambient temperature variation may indicate the ASR damage.

Engineering↗

Laboratory Heat Flux Estimates of Seawater Foam for Low Wind Speeds

Laboratory experiments were conducted to measure the heat flux from seafoam continuously generated in natural seawater. Using a control volume technique, heat flux was calculated from foam and foam-free surfaces as a function of ambient humidity (ranged from 40% to 78%), air–water temperature difference (ranged from -9 °C to 0 °C), and wind speed (variable up to 3 m s-1). Water-surface skin temperature was imaged with a calibrated thermal infrared camera, and near-surface temperature profiles in the air, water, and foam were recorded. Net heat flux from foam surfaces increased with increasing wind speed and was shown to be up to four times greater than a foam-free surface. The fraction of the total heat flux due to the latent heat flux was observed for foam to be 0.75, with this value being relatively constant with wind speed. In contrast, for a foam-free surface the fraction of the total heat flux due to the latent heat flux decreased at higher wind speeds. Temperature profiles through foam are linear and have larger gradients, which increased with wind speed, while foam free surfaces show the expected logarithmic profile and show no variation with temperature. The radiometric surface temperatures show that foam is cooler and more variable than a foam-free surface, and bubble-resolving thermal images show that radiometrically transparent bubble caps and burst bubbles reveal warm foam below the cool surface layer, contributing to the enhanced variability.

54 ENVIRONMENTAL SCIENCES↗

Simulation, Challenge Testing and Validation of Solutions for Residential and Commercial Occupancy Sensing/Counting and CO2 Sensing (Final Report)

Carbon dioxide sensors used for monitoring and control applications in buildings are known to be sensitive to long term drift and can be affected by variations in temperature, humidity, other gas interferents, pressure and other factors that cannot be corrected through the typical auto-calibration methods often embedded in the sensor electronics. This investigation was part of the Category D defined in the ARPA-E Saving Energy Nationwide in Structures With Occupancy Recognition (SENSOR) Financial Assistance Funding Opportunity Announcement No. DE-FOA-0001737, FFDA No. 81.135, January 18, 2017. The FOA defined target criteria for the evaluation of the Category C commercial CO2 sensors selected for review and development through the ARPA-E SENSOR program and charged the Iowa State Category D team with developing an evaluation methodology for Category C sensors in accordance with these criteria. As part of the work, the Iowa State team chose to engage the standards community in the development of the evaluation methodology. Standard development work in the D22.05 Indoor Air and D22.03 Ambient Atmospheres and Source Emissions subcommittees of ASTM International Committee D22 on Air Quality on the evaluation of low cost sensors and provision of guidance for using indoor carbon dioxide concentrations to evaluate indoor air quality and ventilation is of particular relevance to the Category D efforts. To date, three draft standards with specific input by the Iowa State Category D team have passed the subcommittee balloting stage and are being balloted in December 2022 and January 2023 in the main D22 committee. In addition to the aforementioned standards to which the PI was a contributing author, intellectual property developed in this project pertaining to “An Automated System for Evaluation of the Long Term Performance of Carbon Dioxide Sensors” and “An Automated Ground Truth System for Real-Time Reliability Assessment, Capture of Control Decisions and Energy Savings Measurements for Occupancy Recognition Systems and Other Applications” are the other major deliverables of the project. These standards and the developed intellectual property are expected to benefit the public in a number of ways stemming from their provision of means to benchmark the performance of carbon dioxide and other sensor systems. In particular, there is high interest in techniques to demonstrate the performance of low-cost carbon dioxide sensors which can be used for typical HVAC applications (e.g., demand controlled ventilation, outdoor and indoor air monitoring, estimation of occupancy, etc.).

42 ENGINEERING↗

A new method for operating a continuous-flow diffusion chamber to investigate immersion freezing: assessment and performance study

Abstract. Glaciation in mixed-phase clouds predominantly occurs through the immersion-freezing mode where ice-nucleating particles (INPs) immersed within supercooled droplets induce the nucleation of ice. Model representations of this process currently are a large source of uncertainty in simulating cloud radiative properties, so to constrain these estimates, continuous-flow diffusion chamber (CFDC)-style INP devices are commonly used to assess the immersion-freezing efficiencies of INPs. This study explored a new approach to operating such an ice chamber that provides maximum activation of particles without droplet breakthrough and correction factor ambiguity to obtain high-quality INP measurements in a manner that previously had not been demonstrated to be possible. The conditioning section of the chamber was maintained at −20 ∘C and water relative humidity (RHw) conditions of 113 % to maximize the droplet activation, and the droplets were supercooled with an independently temperature-controlled nucleation section at a steady cooling rate (0.5 ∘C min−1) to induce the freezing of droplets and evaporation of unfrozen droplets. The performance of the modified compact ice chamber (MCIC) was evaluated using four INP species: K-feldspar, illite-NX, Argentinian soil dust, and airborne soil dusts from an arable region that had shown ice nucleation over a wide span of supercooled temperatures. Dry-dispersed and size-selected K-feldspar particles were generated in the laboratory. Illite-NX and soil dust particles were sampled during the second phase of the Fifth International Ice Nucleation Workshop (FIN-02) campaign, and airborne soil dust particles were sampled from an ambient aerosol inlet. The measured ice nucleation efficiencies of model aerosols that had a surface active site density (ns) metric were higher but mostly agreed within 1 order of magnitude compared to results reported in the literature.

54 ENVIRONMENTAL SCIENCES↗

A new method for operating a continuous flow diffusion chamber to investigate immersion freezing: assessment and performance study

Glaciation in mixed-phase clouds predominately occurs through the immersion freezing mode where ice nucleating particles (INPs) immersed within supercooled droplets induce nucleation of ice. Currently, model representations of this process are a large source of uncertainty in simulating cloud radiative properties, and to constrain these estimates, continuous flow diffusion chamber (CFDC)-style INP devices are commonly used to assess the immersion freezing efficiencies of INPs. In this study, a new approach was explored to operating such an ice chamber that provides maximum activation of particles without droplet breakthrough and correction factor ambiguity to obtain high-quality INP measurements in a manner that has not been demonstrated as possible previously. The conditioning section of the chamber was maintained at ~ –20 °C and water relative humidity (RH w ) ~ 113 % conditions to maximize the droplet activation, and the droplets were supercooled with an independently temperature-controlled nucleation section at a steady cooling rate (0.5 °C min –1 ) to induce the freezing of droplets and evaporation of unfrozen droplets. The performance of the modified ice chamber was evaluated using four INP species: K-feldspar, illite-NX, Argentinian soil dust, and airborne arable dust that had shown ice nucleation over a wide span of supercooled temperatures. Dry dispersed and size-selected K-feldspar particles were generated in the laboratory. Illite-NX and soil dust particles were sampled during the second phase of the Fifth International Ice Nucleation Workshop (FIN-02) campaign, and airborne arable dust particles were sampled from the aerosol inlet located on the rooftop of the laboratory. The measured ice nucleation efficiencies of model aerosols with a surface active site density (n s ) metric were higher, but mostly agreed within one order of magnitude compared to literature results.

54 ENVIRONMENTAL SCIENCES↗

Energy performance of an operational government building retrofitted with ceiling phase change material tiles in a mixed-humid climate

The aging U.S. building stock requires various retrofit measures to enhance their energy efficiency. Here, this study explores the integration of thermal energy storage and advanced building controls as viable retrofit solutions for load flexibility and peak demand response while maintaining the occupants' comfort. A detailed assessment is conducted on the energy use of an administrative building in Sumner County, Kansas, focusing on the implementation of phase change materials (PCMs) in the ceiling of occupied zones. First, a time-resolved, whole-building energy model is developed in EnergyPlus, incorporating complex thermal behaviors such as air exchange between the plenum space and occupied zones, envelope leakage, and operational schedules. The model is then validated using experimental field test data, and subsequently a parametric assessment of key PCM properties and application strategies is performed to evaluate cooling electricity demand benefits. The parametric study shows that the optimal retrofit strategy, comprising a PCM with 23°C peak melting temperature, 0.125 in. (3.17 mm) thickness, and 150 kJ/kg latent heat, combined with active controls that include 8 h of precooling, forced convection under the ceiling, and a 2°C thermostat setback during peak hours, can result in a maximum load shift during the peak period of 99.6 % and the total electricity savings during the peak period of 98.9 % for the optimum case and thus provide significant cost savings under time-of-use pricing scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗