Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “continuous time system estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Autonomous Navigation Performance During The Hartley 2 Comet Flyby

On November 4, 2010, the EPOXI spacecraft performed a 700-km flyby of the comet Hartley 2 as follow-on to the successful 2005 Deep Impact prime mission. EPOXI, an extended mission for the Deep Impact Flyby spacecraft, returned a wealth of visual and infrared data from Hartley 2, marking the fifth time that high-resolution images of a cometary nucleus have been captured by a spacecraft. The highest resolution science return, captured at closest approach to the comet nucleus, was enabled by use of an onboard autonomous navigation system called AutoNav. AutoNav estimates the comet-relative spacecraft trajectory using optical measurements from the Medium Resolution Imager (MRI) and provides this relative position information to the Attitude Determination and Control System (ADCS) for maintaining instrument pointing on the comet. For the EPOXI mission, AutoNav was tasked to enable continuous tracking of a smaller, more active Hartley 2, as compared to Tempel 1, through the full encounter while traveling at a higher velocity. To meet the mission goal of capturing the comet in all MRI science images, position knowledge accuracies of +/- 3.5 km (3-?) cross track and +/- 0.3 seconds (3-?) time of flight were required. A flight-code-in-the-loop Monte Carlo simulation assessed AutoNav's statistical performance under the Hartley 2 flyby dynamics and determined optimal configuration. The AutoNav performance at Hartley 2 was successful, capturing the comet in all of the MRI images. The maximum residual between observed and predicted comet locations was 20 MRI pixels, primarily influenced by the center of brightness offset from the center of mass in the observations and attitude knowledge errors. This paper discusses the Monte Carlo-based analysis that led to the final AutoNav configuration and a comparison of the predicted performance with the flyby performance.

flyby↗

Adaptive Data Processing Technique for Lidar-Assisted Control to Bridge the Gap between Lidar Systems and Wind Turbines: Preprint

This paper presents first steps toward an adaptive lidar data processing technique crucial for lidar-assisted control in wind turbines. The prediction time and the quality of the wind preview from lidar measurements depend on several factors and are not constant. If the data processing is not continually adjusted, the benefit of lidar-assisted control cannot be fully exploited, or can even result in harmful control action. An online analysis of the lidar and turbine data are necessary to continually reassess the prediction time and lidar data quality. In this work, a structured process to develop an analysis tool for the prediction time and a new hardware setup for lidar-assisted control are presented. The tool consists of an online estimation of the rotor effective wind speed from lidar and turbine data and the implementation of an online cross correlation to determine the time shift between both signals. Further, initial results from an ongoing campaign in which this system was employed for providing lidar preview for feed-forward pitch control are presented.

17 WIND ENERGY↗

First Attempt of Global-scale Assimilation of Subdaily Scale Soil Moisture Estimates from CYGNSS and SMAP into a Land Surface Model

Soil moisture performs a key function in the hydrologic process and understanding the global-scale water cycle. However, estimations of soil moisture taken from current sun-synchronous orbit (SSO) satellites are limited in that they are neither spatially nor temporally continuous. This limitation creates discontinuous soil moisture observation from space and hampers our understanding of the fundamental processes that control the surface hydrologic cycle across both time and space domains. Here, we propose to use frequent soil moisture observations from NASA’s constellation of eight micro-satellites called the Cyclone Global Navigation Satellite System(CYGNSS) together with the Soil Moisture Active Passive (SMAP) to assimilate subdaily-scale soil moisture intoa land surface model(LSM). Our results, which are based on triple collocation analysis(TCA), show how current scientific advances in satellite systems can fill previous gaps in soil moisture observations in subdaily scale bypast observations, and eventually adds value to improvements in global scale soil moisture estimates in LSMs. Overall, TCA-based fractional mean square errors (fMSE) of LSM soil moisture are improved by 61% with the synergetic assimilation of CYGNSS data with SMAP soil moisture observations. However, assimilating satellite-based soil moisture over dense vegetation areas can degrade the performance of LSMs as these areas propagate erroneous soil moisture information to LSMs. To our knowledge, this study isthe first global assimilation of GNSS-based soil moisture observations in land surface models.

Hyunglok Kim↗

A Compact, High-Performance Continuous Magnetic Refrigerator

We present test results of the first adiabatic demagnetization refrigerator (ADR) that can produce continuous cooling at sub-kelvin temperatures. This system uses multiple stages that operate in sequence to cascade heat from a continuous stage up to a heat sink. Continuous operation aids the usual constraints of long hold times and short recycle times that lead to the generally large mass of single-shot ADRs, and allows us to achieve much higher cooling power per unit mass. Our design goal is 10 microW of cooling at 50 mK while rejecting heat to a 6-10 K heat sink. The total cold mass is estimated to be less than 10 kg, including magnetic shielding of each stage. These parameters envelop the requirements for currently planned astronomy missions. The relatively high heat rejection capability allows it to operate with a mechanical cryocooler as part of a cryogen-free, low temperature cooling system. This has the advantages of long, mission life and reduced complexity and cost. At present, we have assembled a three-stage ADR that operates with a superfluid helium bath. Additional work is underway to develop magnetocaloric materials that can extend its heat rejection capability up to 10 K. This paper discusses the design and operation of the ADR, as well as interface requirements for cryocooler-based operation.

Shirron, Peter↗

Direct Breakthrough Curve Prediction From Statistics of Heterogeneous Conductivity Fields

In this paper, we present a methodology to predict the shape of solute breakthrough curves in heterogeneous aquifers at early times and/or under high degrees of heterogeneity, both cases in which the classical macrodispersion theory may not be applicable. The methodology relies on the observation that breakthrough curves in heterogeneous media are generally well described by lognormal distributions, and mean breakthrough times can be predicted analytically. The log-variance of solute arrival is thus sufficient to completely specify the breakthrough curves, and this is calibrated as a function of aquifer heterogeneity and dimensionless distance from a source plane by means of Monte Carlo analysis and statistical regression. Using the ensemble of simulated groundwater flow and solute transport realizations employed to calibrate the predictive regression, reliability estimates for the prediction are also developed. Additional theoretical contributions include heuristics for the time until an effective macrodispersion coefficient becomes applicable, and also an expression for its magnitude that applies in highly heterogeneous systems. Finally, it is seen that the results here represent a way to derive continuous time random walk transition distributions from physical considerations rather than from empirical field calibration.

58 GEOSCIENCES↗

Glassy quantum nuclear pasta in neutron star crusts

We conduct a comprehensive survey of the shape parameter space of the nuclear pasta phases in neutron star crusts by conducting three-dimensional Hartree-Fock + BCS calculations. Spaghetti, waffles, lasagna, bicontinuous phases and cylindrical holes occupy local minima in the resulting constant-pressure Gibbs energy surfaces, implying multiple geometries coexist at a given depth. Notably, the bicontinuous phase, in which both the neutron gas and nuclear matter extend continuously in all dimensions appears over a large depth range. Our results support the idea that nuclear pasta is a glassy system. At a characteristic temperature, of order 10 8 – 10 9 K, different phases may become frozen into domains whose sizes we estimate to be 1–50 times the lattice spacing and over which the local density and electron fraction can vary. Above this temperature, very little long-range order exists and matter is an amorphous solid. Electron scattering off domain boundaries may contribute to the disorder resistivity of the pasta phases. Annealing of the domains may occur during cooling; repopulating of local minima during crustal heating might lead to temperature-dependent transport properties in the deep crust layers. We identify four regions distinguished by whether pasta is the true ground state, and whether the pasta structure allows delocalization of protons. The whole pasta region can occupy up to 70% of the crust by mass and 25% by thickness, and the layer in which protons are delocalized could occupy 45% of the crust mass and 15% of its thickness.

79 ASTRONOMY AND ASTROPHYSICS↗

NASA GEOS-3/TRMM Re-analysis: Capturing Observed Tropical Rainfall Variability in Global Analysis for Climate Research

Understanding climate variability over a wide range of space-time scales requires a comprehensive description of the earth system. Global analyses produced by a fixed assimilation system (i.e., re-analyses) - as their quality continues to improve - have the potential of providing a vital tool for meeting this challenge. But at the present time, the usefulness of re-analyses is limited by uncertainties in such basic fields as clouds, precipitation, and evaporation - especially in the tropics, where observations are relatively sparse. Analyses of the tropics have long been shown to be sensitive to. the treatment of cloud precipitation processes, which remains a major source of uncertainty in current models. Yet, for many climate studies it is crucial that analyses can accurately reproduce the observed rainfall intensity and variability since a small error of 1 mm/d in surface rain translates into an error of approx. 30 W/sq m in energy (latent heat) flux. Currently, discrepancies between the observed and analyzed monthly-mean rain rates averaged to 100 km x 100 km resolution can exceed 4 mm/d (or 120 W/sq m ), compared to uncertainties in surface radiative fluxes of approx. 10-20 W/sq m . Improving precipitation in analyses would reduce a major source of uncertainty in the global energy budget. Uncertainties in tropical precipitation have also been a major impediment in understanding how the tropics interact with other regions, including the remote response to El Nino/Southern Oscillation (ENSO) variability on interannual time scales, the influence of Madden-Julian Oscillation (MJO) and monsoons on intraseasonal time scales. A global analysis that can replicate the observed precipitation variability together with physically consistent estimates of other atmospheric variables provides the key to breaking this roadblock. NASA Goddard Space Flight Center has been exploring the use of satellite-based microwave rainfall measurements in improving global analyses and has recently produced a multi-year, 1 x 1 TRMM re-analysis , which assimilates 6-hourly TMI and SSM/I surface rain rates over tropical oceans using a ID variational continuous assimilation (VCA) procedure in the GEOS-3 global data assimilation system. The analysis period extends from 1 November 1997 through 3 1 December 2002. The goal is to produce a multi-year global analysis that is dynamically consistent with available tropical precipitation observations for the community to assess its utility in climate applications and identify areas for further improvements. A distinct feature of the GEOS-3RRMh4 re-analysis is that its precipitation analysis is not derived from a short-term forecast (as done in most operational systems) but is given by a time- continuous model integration constrained by precipitation observations within a 6-h analysis window, while the wind, temperature, and pressure fields are allowed to directly respond to the improved precipitation and associated latent heating structures within the same analysis window. In this talk, I will assess the impact VCA precipitation assimilation on analyses of climate signals ranging from a few weeks to interannual time scales and compare results against other operational and reanalysis products.

Hou, Arthur Y.↗

Baker-Barry Tunnel Lighting: Evaluation of a Potential GATEWAY Demonstrations Project

The U.S. Department of Energy is evaluating the Baker-Barry Tunnel as a potential GATEWAY Demonstrations project for deployment of solid-state lighting (SSL) technology. The National Park Service views this project as a possible proving ground and template for implementation of light-emitting diode (LED) luminaires in other tunnels, thereby expanding the estimated 40% energy savings from 132 MWh/yr to a much larger figure nationally. Most of the energy savings in this application is attributable to the instant-restrike capability of LED products and to their high tolerance for frequent on/off switching, used here to separately control either end of the tunnel during daytime hours. Some LED luminaires rival or outperform their high-intensity discharge (HID) counterparts in terms of efficacy, but options are limited, and smaller lumen packages preclude true one-for-one equivalence. However, LED products continue to improve in efficacy and affordability at a rate unmatched by other light source technologies; the estimated simple payback period of eight years (excluding installation costs and maintenance savings) can be expected to improve with time. The proposed revisions to the existing high-pressure sodium (HPS) lighting system would require slightly increased controls complexity and significantly increased luminaire types and quantities. In exchange, substantial annual savings (from reduced maintenance and energy use) would be complemented by improved quantity and quality of illumination. Although advanced lighting controls could offer additional savings, it is unclear whether such a system would prove cost-effective; this topic may be explored in future work.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Baker-Barry Tunnel Lighting: Evaluation of a Potential GATEWAY Demonstrations Project

The U.S. Department of Energy is evaluating the Baker-Barry Tunnel as a potential GATEWAY Demonstrations project for deployment of solid-state lighting (SSL) technology. The National Park Service views this project as a possible proving ground and template for implementation of light-emitting diode (LED) luminaires in other tunnels, thereby expanding the estimated 40% energy savings from 132 MWh/yr to a much larger figure nationally. Most of the energy savings in this application is attributable to the instant-restrike capability of LED products and to their high tolerance for frequent on/off switching, used here to separately control either end of the tunnel during daytime hours. Some LED luminaires rival or outperform their high-intensity discharge (HID) counterparts in terms of efficacy, but options are limited, and smaller lumen packages preclude true one-for-one equivalence. However, LED products continue to improve in efficacy and affordability at a rate unmatched by other light source technologies; the estimated simple payback period of 20 years (excluding installation costs and maintenance savings) can be expected to improve with time. The proposed revisions to the existing high-pressure sodium (HPS) lighting system would require slightly increased controls complexity and significantly increased luminaire types and quantities. In exchange, substantial annual savings (from reduced maintenance and energy use) would be complemented by improved quantity and quality of illumination. Although advanced lighting controls could offer additional savings, it is unclear whether such a system would prove cost-effective; this topic may be explored in future work.

Baker-Barry Tunnel↗

FINAL REPORT - Development of High Pressure Hydrogen Storage Tank for Storage and Gaseous Truck Delivery

The “Development of High Pressure Hydrogen Storage Tanks for Storage and Gaseous Truck Delivery” project [DE-FG36-08GO18062] was initiated on 01 July 2008. Hexagon Lincoln (then Lincoln Composites) received grant funding from the U.S. Department of Energy to support the design and development of an improved bulk hauling and storage solution for hydrogen in terms of cost, safety, weight and volumetric efficiency. The development of this capability required parallel development and qualification of large all-composites pressure vessels, a custom ISO container to transport and store said tanks, and performance of trade studies to identify optimal operating pressure for the system. Qualification of the 250 bar TITAN® module was completed in 2009 with supervision from the American Bureau of Shipping [ABS], and the equipment has been used internationally for bulk transportation of fuel gases since 2010. Phase 1 of the project was successfully completed in 2012 with the issuance of USDOT SP 14951, the special permit authorizing the manufacture, marking, sale and use of TITAN® Mobile Pipeline® equipment in the United States. The introduction of tube trailers with light weight composite tankage has meant that 2 to 3 times as much gaseous fuel can be transported with each trip. This increased hauling efficiency offers dramatically reduced operating costs and has enabled a profitable business model for over-the-road compressed natural gas delivery. The economic drivers of this business opportunity vary from country to country and region to region, but in many places gas distribution companies have realized profitable operations. Additional testing was performed in 2015 to characterize hydrogen-specific operating protocols for use of TITAN® systems in CHG service at 250 bar. This program demonstrated that existing compression and decompression methodologies can efficiently and safely fill and unload lightweight bulk hauling systems. Hexagon Lincoln and U.S. DOE agreed to continue into Phase 2 of the project without pursuing the development of higher pressure capabilities as originally planned. At 250 bar, development of equipment for hydrogen transport is supported by strong activity in the adjacent natural gas transportation sector. Trade studies performed since 2011 indicate optimization of hauling efficiency and system cost for hydrogen transport at about 350 bar (5076 psi). However, due to reduced efficiency of compression of natural gas above 250 bar, 350 bar operation is not an attractive option for natural gas transportation. The CHG market is not developed at this time, and it is difficult to forecast the arrival of significant revenues. On the investment side, the cost to fully qualify a large tank module at 350 bar is estimated at $3MM to $5MM. There is insufficient CHG market definition to support a stand-alone business case for this investment without near term revenue in the adjacent CNG transportation market. Therefore development of a 350 bar TITAN® system was deferred and not pursued under this project. Hexagon Lincoln continues to support the development of tankage and equipment for operation at 350 bar and above; with 700 bar vehicle tanks and 950 bar tanks for ground storage applications. Phase 2 activities were focused on reducing system cost, increasing system capacity, increasing system safety and characterization of polymer material performance specific to hydrogen pressure vessel usage. With the successful launch of TITAN® modules and trailers in natural gas transportation, over 600 units have been produced through the end of 2016, resulting in improved purchasing power for raw materials and manufactured components. This has allowed Hexagon Lincoln to approach the current project goals for system cost. At $590/kg of compressed hydrogen delivered, the system cost of the baseline TITAN® module is below the project’s 2015 target of $730/kg H2 delivered, and very close to the project’s 2020 target of $575/kg H2 delivered. [Based on product pricing in 1Q2017.] Emphasis was placed on configuration of larger capacity systems within the vehicle weights and dimensions allowed on federal and state highways in the United States and other countries. These activities resulted in the design and development of integrated tube trailer systems that have increased delivery capacities by 45%. The hydrogen delivery capacity of our largest system is 845 kg, exceeding the project’s 2015 target of 700 kg H2 delivered. Emerging technologies offering improvement of the safety systems used on the equipment were investigated, with particular focus on improving the reliability and cost of the emergency venting system for fire protection. Finally, investment in our materials laboratory improved detection and characterization of hydrogen-induced damage in polymer materials, supporting the development of operational protocols to avoid damage to pressure vessel liners and valve components.

08 HYDROGEN↗

Convergence of Vehicle and Infrastructure Data for Traffic and Demand Management

The increasing availability of highly granular, vehicle trajectory data combined with ever increasing stores of roadway sensor data has provided unparalleled observability into the operation of our urban roadway networks. These data sources are quickly moving from research and prototype environments into full-scale commercial deployment and data offerings. The observability gained allows for increased control opportunities to enhance transportation mobility, safety and energy efficiency. The National Renewable Energy Laboratory (NREL) is involved in three initiatives to leverage these data for positive outcomes: 1) In 2015 NREL, in cooperation with industry and university partners, was awarded an ARPA-E research grant to research a control architecture to incentivize individual travelers toward more sustainable travel behavior. Based on real-time data on the traveler's destination and state of the system, the traveler is presented with route and/or mode choices and offered incentives to accept sustainable alternatives over less-sustainable ones. The project tests the extent to which small incentives can influence, or tip the balance toward more sustainable travel behavior. 2) Although commercial sources of travel time and speed have emerged in recent years based on vehicle probe data, volume estimates continue to rely primarily on historical count data factored for the time of day, day of week, and season of year. Real-time volume flows would enable better tools, simulation in the loop, and ultimately more effective control outcomes. NREL in cooperation with the University of Maryland and industry traffic data providers (INRIX, HERE and TomTom), are attempting to accelerate the timeframe to a viable real-time vehicle volume data feed based on probe data. 3) Signal control on urban arterials for years has had to rely on models rather than measured data to assess performance. High-resolution controller data and low-cost re-identification data now allows for direct measurement of the quality of progression along a corridor. Though still requiring an investment in equipment and communications, these data sources are transforming traffic signal management to a data driven, performance management basis. Ever increasing availability of granular GPS trace data from automobiles may allow for assessment of traffic signal performance, allowing for signal optimization while minimizing the investment in additional sensors and communication infrastructure.

33 ADVANCED PROPULSION SYSTEMS↗

Determination of a Generic Human Error Probability Distribution, Part 1: A Dynamic Formulation of SPAR-H

In almost all major nuclear power plants (NPP) events include a significant human error component. As an example, in Fukushima Daiichi (2011) nuclear meltdown, the human actions related to the high-pressure injection cooling strongly affected accident evolution. Furthermore, in the Three Mile Island accident (1979) (which was initiated by a stuck open valve and thus was triggered a loss of coolant accident) the unit operators made decisions based upon false assumptions that contributed negatively to the accident. Given these premises, the ability to accurately model human interactions with plant evolution and, in particular, dynamically calculate human error probability (HEP) plays a major role in a probabilistic risk analysis (PRA). Human reliability analysis (HRA) identifies and models the causes of human errors, and quantifies HEP by applying different methodologies. HRA methods identify errors and reflect on the understanding of error-prone people and systems. There are a number of HRA methods available that assist in identifying the vulnerabilities in the system and provide guidance in determining the HEP. HEP is the probability of a human failure event (HFE), and quantification of HEPs under various situations is utilized in PRA of large complex systems. One of the more prominent HRA methods is the Standardized Plant Analysis Risk-Human Reliability Analysis (SPAR-H) method that was developed to estimate HEPs for the use in the Standardized Plant Analysis Risk (SPAR) PRA models employed in U.S. NPPs. SPAR-H is implemented in U.S. NPPs by regulators at the U.S. Nuclear Regulatory Commission (NRC) to determine the HEP based on expert estimation through the use of calculation worksheets. In SPAR-H, the nominal HEPs (NHEPs) are multiplied by performance shaping factors (PSF) multiplier values to obtain the overall error probability. PSFs encompass the human components, individual characteristics, their environment, and aspects of the task. With PSFs, the goal is to capture all factors that can affect human performance. In SPAR-H there are eight PSFs used, each having respective levels corresponding to multipliers: Available Time, Stress/Stressors, Complexity, Experience/Training, Procedures, Ergonomics/Human Machine Interface, Fitness for Duty, and Work Processes. The PSF multipliers indicate enhanced, nominal, or degraded human performance. The SPAR-H method estimates the HEP through multiplying a NHEP with PSFs. Hence, SPAR-H is a traditional HRA method that assesses human performance at a fixed, or static, point in time. In a dynamic HRA framework, human performance is assessed on a continuous time basis. SPAR-H can be used within a dynamic PRA framework through the use of simulation and stochastic models. The goal of dynamic HRA is to build a more realistic model of the human-system interaction to enhance calculation of reliability, risk and safety analysis. The progression of events in dynamic SPAR-H considers that some PSFs may experience gradual change, while other change can be sudden due to individualistic differences or rapid plant status changes. The PSF changes are caused by contextual changes in the scenario. For example, as more time passes, the realization that a task should be completed sooner may cause the operator more stress. In another example, a sudden relay of information about sickness of a family member may alter the operator's general stress level and fitness for duty. Each PSF has a different dynamic nature; PSFs like stress and complexity change more quickly over the course of a task than experience and training. While the experience of an operator changes over the course of attaining the objective, the amount that this added experience changes the HEP is very minimal. In contrast, the stress, complexity, and procedures PSFs may change quite a bit over the course of task completion.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Continuous and discrete modeling of HIV-1 decline on therapy

Mathematical models have shed light on the dynamics of HIV- 1 infection in vivo. In this paper, we generalize continuous mathematical models of drug therapy for HIV-1 by Perelson et al. (Science 271:1582–1586, 1996) and Perelson and Nelson (SIAM Rev 41:3–44, 1999) on time scales, i.e., a nonempty closed subset of real numbers in order to derive new discrete models that predict the total concentration of plasma virus as a function of time. Here, one of our main goals is to compare discrete mathematical models with the continuous model in Perelson et al. (1996) where HIV infected patients were given protease inhibitors and sampled frequently thereafter. For the comparison, we use experimental data collected in Perelson et al. (1996) and estimate the parameters such as the virion clearance rate and the rate of loss of infected cells by fitting the total concentration of plasma virus to this data set. Our results show that discrete systems describe the best fit. In the previous models of this study, the efficacy of protease inhibitor is assumed to be perfect. Motivated by Perelson and Nelson (1999), we end the paper with a mathematical model of imperfect protease inhibitor and reverse transcriptase (RT) inhibitor combination therapy of HIV-1 infection on time scales with its stability analysis.

60 APPLIED LIFE SCIENCES↗

SPECKLE INTERFEROMETRY AND ORBITS OF 'FAST' VISUAL BINARIES

Results of speckle observations at the 4.1 m SOAR telescope in 2012 (158 measures of 121 systems, 27 non-resolutions) are reported. The aim is to follow fast orbital motion of recently discovered or neglected close binaries and sub-systems. Here, eight previously known orbits are defined better, two more are completely revised, and five orbits are computed for the first time. Using differential photometry from Hipparcos or speckle and the standard relation between mass and absolute magnitude, the component's masses and dynamical parallaxes are estimated for all 15 systems with new or updated orbits. Two astrometric binaries HIP 54214 and 56245 are resolved here for the first time, another eight are measured. We highlight several unresolved pairs that may actually be single despite multiple historic measures, such as 104 Tau and f Pup AB. Continued monitoring is needed to understand those enigmatic cases.

79 ASTRONOMY AND ASTROPHYSICS↗

Hydrogen Generation Rates for Tank 50 and Saltstone Related Samples using a Sealed Reactor System

This report documents the results of sealed reactor tests to measure the hydrogen generation rate (HGR) from Tank 50 waste, which may be on the order of 10 -10 (ft 3 /h)/gal. Because the estimated HGR limit of detection (LOD) for an open, continuous flow system is approximately 10 -7 (ft 3 /h)/gal a more sensitive method was needed. By accumulating generated gasses in a sealed system without a continuous purge gas, the resulting concentrations can increase the sensitivity of measurement, which is based on time of heating.

08 HYDROGEN↗

Design Report on the MiniFuel Instrumented Test Apparatus for Understanding Radiation Effects

Most nuclear fuels irradiations at Oak Ridge National Laboratory (ORNL) over the past decade have been conducted using MiniFuel—a static capsule design employing subscale fuel specimens to collect separate-effects irradiated fuel performance data. Irradiation conditions for MiniFuel experiments are predicted pre-test using reactor physics, and thermal models are verified post-irradiation via SiC dilatometry and various spectrometry methods. Relevant fuel performance parameters are also observed post-irradiation in a hot cell, thereby providing a single data point for each parameter representing the cumulative effects of the irradiation conditions. Substantially more data can be harvested from a single test and within a shorter duration by instrumenting irradiation vehicles and measuring desired quantities in situ. This report presents the design and analysis of the MiniFuel INstrumented Irradiation Test Apparatus for Understanding Radiation Effects (MINITAURE)—an instrumented test rig based on the separate-effects MiniFuel concept that aims to capture fission gas release (FGR) and thermal conductivity degradation of fuel specimens during irradiation in the High Flux Isotope Reactor (HFIR). MINITAURE will be integrated with the Materials Irradiation Facility (MIF) located in the HFIR building outside the reactor containment. The MIF will act as the instrumentation and control center for the experiment, enabling real-time feedback from in situ sensors and control of irradiation temperatures via a gas delivery system. Two unique capsule designs were developed to capture each phenomenon: the thermal conductivity capsule, which uses a thermopile method to estimate fuel specimen thermal conductivity, and the fission gas release capsule, which will have continuous flowing gas communication to high-purity germanium detectors that are housed in the MIF for monitoring FGR. This report details the reactor physics and heat transfer modeling activities that were used to inform the experiment design and predict capsule performance. It also describes out-of-pile activities conducted to stand up this new capability and verify the measurement techniques. Modeling efforts to date have demonstrated the feasibility of the in situ measurement techniques and supported the development of the MINITAURE assembly configuration. Out-of-pile testing of the thermal conductivity measurement shows promise in capturing relative changes in thermal conductivity. However, significant errors exist in the measured absolute value, posing a need for further refinement.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Automatic high-frequency measurements of full soil greenhouse gas fluxes in a tropical forest

Measuring in situ soil fluxes of carbon dioxide (CO 2 ), methane(CH 4 ), and nitrous oxide (N 2 O) continuously at highfrequency requires appropriate technology. We tested the combination of acommercial automated soil CO 2 flux chamber system (LI-8100A) with a CH 4 and N 2 O analyzer (Picarro G2308) in a tropicalrainforest for 4 months. A chamber closure time of 2 min was sufficient fora reliable estimation of CO 2 and CH 4 fluxes (100 %and 98.5 % of fluxes were above minimum detectable flux – MDF,respectively). This closure time was generally not suitable for a reliableestimation of the low N 2 O fluxes in this ecosystem but wassufficient for detecting rare major peak events. A closure time of 25 minwas more appropriate for reliable estimation of most N 2 O fluxes(85.6 % of measured fluxes are above MDF ± 0.002 nmol m -2 s -1 ). Our study highlights the importance ofadjusted closure time for each gas.

54 ENVIRONMENTAL SCIENCES↗