Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “constraint energy minimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Coordinated operation of pumped-storage hydropower with power and water distribution systems

Small pumped-storage hydropower (PSH) units have gained popularity as distributed energy storage options that can provide flexibility to the operation of power distribution systems. Optimal operation of small PSH units is not only dependent on the energy storage provided to power distribution system, but also on the inflow and outflow of water from and to the water distribution system. Here, in this context, this paper develops an optimization model for coordinated operation of PSH units with power and water distribution systems. The proposed model optimizes the operation of water tanks, variable-speed pumps and PSH in pumping and generating modes to minimize the operation cost of power distribution system, while respecting the power flow constraints of power distribution and hydraulic constraints of water distribution system. Appropriate electricity tariffs are implemented to avoid additional expenses in water distribution system that can be enforced by its coordinated operation in favor of power distribution system. The proposed model is implemented on a 33-bus and a 123-bus test power distribution system connected to a 16-node test water distribution system. Results demonstrate the effectiveness of proposed model in tapping PSH flexibility to reduce the operation cost of power and water distribution systems, while meeting the power and water demands.

13 HYDRO ENERGY↗

Active rotor coning for a 25 MW downwind offshore wind turbine

A two-bladed downwind turbine system was upscaled from 13.2 MW to 25 MW by redesigning aerodynamics, structures, and controls. In particular, three 25-MW rotors were developed, and the final version is a fully redesigned model of the original rotor. Despite their radically large sizes, it was found that these 25-MW turbine rotors satisfy this limited set of structural design drivers at the rated condition and that larger blade lengths are possible with conewise load-alignment. In addition, flapwise morphing (varying the cone angle with a wind-speed schedule) was investigated to minimize mean and fluctuating blade root bending loads using steady inflow proxies for the maximum and lifetime damage equivalent load moments. Compared to the fixed coned rotor case, morphing can provide an Annual Energy Production (AEP) increase of 6%, and the maximum blade root flapwise bending moment increases 21% (still under the constraint, i.e., 10% of the ultimate moments) as a trade-off. The resulting series of 25-MW rotors can be a valuable baseline for further development and assessment of ultra-large-scale wind turbines.

17 WIND ENERGY↗

Acceleration of Thermochemistry Solves in MOOSE and Pronghorn

This work focuses on the development and implementation of strategies to accelerate thermochemical calculations within MOOSE-based multiphysics simulations, particularly for applications in MSRs. We highlight the inherent complexity of nuclear materials, which require a multiscale approach to accurately model their behavior across various physical domains, including mechanical, chemical, and thermal phenomena. Thermochemical equilibrium calculations are crucial for predicting material properties and enhancing the fidelity of these simulations. The integration of Thermochimica, a Gibbs energy minimizer, into MOOSE allows for the direct minimization of Gibbs energy at every point on the mesh. However, the computational cost of such integration is significant. To address this, we explored acceleration strategies such as multi-threading support and the use of a thermodynamic ValueCache to reduce redundant calculations. Additionally, we investigated modifications to Thermochimica to enable phase constraints and improve its coupling with phase-field models, which are essential for simulating microstructural evolution and corrosion in MSR. These efforts aim to optimize the computational efficiency and accuracy of multiphysics simulations, thereby supporting the development of reliable and efficient nuclear materials for next-generation reactor technologies.

36 - MATERIALS SCIENCE↗

Innovative Approach Enabled the Retirement of TDRS-1 Compliant with NASA Orbital Debris Requirements

The first Tracking and Data Relay Satellite (TDRS-1) was deactivated on June 27th 2010 following more than 26 years of operation. The end-of-mission (EOM) operations were developed to address the stringent requirements of NPR 8715.6: NASA Procedural Requirements for Limiting Orbital Debris, which consists of three key items: 1) removal from the geosynchronous arc; 2) depletion of the remaining propellant; and 3) passivation of all sources of energy storage or generation [1]. The EOM approach minimized risks while accomplishing these goals. Raising TDRS-1 over 350 km above geosynchronous was accomplished via proven station change operations. Depleting propellant was the most challenging task, requiring over 20 hours of thruster on-time accumulated within schedule, orbit, and spacecraft subsystem constraints. The attitude configuration and operational procedures, including the unique final passivation method, were thoroughly analyzed and simulated prior to the start of operations. The complete EOM campaign lasted 21 days. The TDRS-1 EOM campaign demonstrated that pre-NPR 8715.6 satellite designs can be made to comply and that lessons learned could be applied to other satellite designs. The significant TDRS-1 effort demonstrates a commitment by NASA to responsible orbital debris management in compliance with international standards.

Zaleski, Ronald↗

Optimal Demand Response Incorporating Distribution LMP with PV Generation Uncertainty

The utilization of aggregated demand-side flexibility via demand response (DR) has become a promising pathway for the integration of renewable energy resources in power systems. Nowadays, there are several management strategies for DR such as the price-based transactive control strategies. However, many of such existing price-based control strategies neglect the physics and operational constraints of the underlying distribution networks when computing the price, raising concerns regarding their theoretical and practical values. This paper studies this issue and investigates optimal DR (ODR) by incorporating the distribution locational marginal price (DLMP). In particular, we discuss DR in connection with DLMPs and propose a multiperiod bilevel optimization problem to find the ODR strategy. Here, the objective is to minimize the peak load, load fluctuation, and payments of load aggregators. In addition, a robust bilevel ODR model is formulated to provide a robust ODR strategy while minimizing operating costs under the worst-case realization of uncertainties; this mitigates the impact of forecasting errors on renewable energy resources. Then, we propose an efficient solution approach by employing the Karush-Kuhn-Tucker conditions and strong duality. Simulation results are presented to illustrate the mutual impacts of the interaction between DR and DLMP and the benefits of the robust ODR strategy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Dependent Pressure Vessel (DPV) nickel-hydrogen spacecraft cell and battery design

The dependent pressure vessel (DPV) nickel-hydrogen (NiH2) battery is being developed as a potential spacecraft battery design for both military and commercial satellites. Individual pressure vessel (IPV) NiH2 batteries are currently flying on more than 70 Earth orbital satellites and have accumulated more than 140,000,000 cell-hours in actual spacecraft operation. The limitations of standard NiH2 IPV flight battery technology are primarily related to the internal cell design and the battery packaging issues associated with grouping multiple cylindrical cells. The DPV cell design offers higher specific energy and reduced cost, while retaining the established IPV NiH2 technology flight heritage and database. The advanced cell design offers a more efficient mechanical, electrical and thermal cell configuration and a reduced parts count. The internal electrode stack is a prismatic flat-plate arrangement. The flat individual cell pressure vessel provides a maximum direct thermal path for removing heat from the electrode stack. The cell geometry also minimizes multiple-cell battery packaging constraints by using an established end-plateltie-rod battery design. A major design advantage is that the battery support structure is efficiently required to restrain only the force applied to a portion of the end cell. As the cells are stacked in series to achieve the desired system voltage, this increment of the total battery weight becomes small. The geometry of the DPV cell promotes compact, minimum volume packaging and places all cell terminals along the length of the battery. The resulting ability to minimize intercell wiring offers additional design simplicity and significant weight savings. The DPV battery design offers significant cost and weight savings advantages while providing minimal design risks. Cell and battery level design issues will be addressed including mechanical, electrical and thermal design aspects. A design performance analysis will be presented at both the cell and battery level. The DPV is capable of delivering up to 76 Watt-hours per kilogram (Wh/kg) at the cell level and 70 Wh/kg at the full battery level. This represents a 40 percent increase in specific energy at the cell level and a 60 percent increase in specific energy at the battery level compared to current IPV NiH2 technology.

Coates, Dwaine↗

Making Small-Volume Heat Pump Water Heaters Larger: A Design Framework for Integrated Phase Change Material Heat Exchangers

Those that use electricity for water heating, the majority use resistive elements rather than heat pump water heaters (HPWHs), the latter of which use 60-70% less energy than the former. One major barrier to wider HPWH adoption is the added equipment required, which prevents current 50-80-gallon tanks on the market from fitting into smaller utility closets sized for 30-40 gallons, such as those found in manufactured housing. Additionally, these smaller HPWHs tend to underperform relative to their larger counterparts. One solution that addresses both space and performance concerns is thermal energy storage, and in particular, phase change materials (PCMs). PCMs have been studied extensively in building envelope and HVAC systems, but remain a nascent technology in residential water heating. While water itself has a uniquely high energy storage capacity, PCMs have an even higher energy storage density, thus providing the potential to elevate the performance of 40-gallon HPWHs to that of 50-gallon or larger tanks. This research is part of a larger project that seeks to utilize thermal energy storage to enable decarbonized water heating in low-income communities. In this study, we outline the design process used to produce novel PCM heat exchangers for use in small-volume HPWH tanks, including the identification of design constraints and performance targets relevant to real-world applications. In order to ensure optimal PCM utilization and tank storage capacity, we focus here on co-maximizing surface area and PCM volume in the heat exchangers; therefore, this research targets triply periodic minimal surface (TPMS) lattices. TPMS lattices boast enhanced heat transfer capabilities compared to traditional heat exchanger geometries and offer highly tailorable designs; thus, they pair well with the growing field of additive manufacturing, or 3D printing. Starting with a suite of TPMS lattices, we demonstrate a systematic approach for narrowing down feasible designs that comply with identified constraints while meeting PCM performance objectives.

25 ENERGY STORAGE↗

Model Predictive Control for a Grid-interactive Efficient Thermal Storage-integrated Heat Pump System

Building heating and cooling systems can be used to overcome the mismatch between the intermittent supply of renewable power and the fluctuating demand for electricity. A novel underground thermal energy storage integrated with a dual-source heat pump has been proposed to mitigate the mismatch while meeting the thermal demand of buildings efficiently. Conventional thermostat control with heuristic rules cannot provide intelligent decisions to maximize the thermal efficiency and flexibility of the proposed system. Advanced control strategies like model predictive control (MPC) have provided a new paradigm for grid-interactive efficient building operation with the advancement of computation and sensing. This study developed an MPC for the proposed system to provide grid service for Demand Side Management and minimize the operating cost of building owners. A control-oriented dynamic model of the proposed system has been developed. Given an objective function and proper constraints, an optimization problem is formulated to determine the optimal control strategy of the system. Dynamic Programming is adopted to solve the optimization problem. A rule-based control (RBC) is also developed to achieve similar goals. Short-term simulations are conducted to compare the system performance resulting from the two controls. The simulation results indicate that the MPC performs more intelligently than the RBC in charging thermal energy storage and selecting heat pump sources by taking advantage of the predicted cooling demands of the building and the performance of the integrated system. As a result, the MPC could save energy and reduce operating costs compared with the RBC. A case study shows that, for a 3-day operation, the MPC saves 36.9% energy and reduces 38.5% operating cost compared with the RBC.

Shi, Liang↗

Advances in high-pressure and high-temperature heat exchangers: Innovations via additive manufacturing and their applications

This paper provides a comprehensive overview of technological developments and applications for high-pressure and high-temperature (HPHT) heat exchangers produced through additive manufacturing (AM) techniques. As the demand for high-efficiency energy systems has been rising, the role of heat exchangers for thermal management and transport is becoming increasingly crucial. In this context, AM has emerged as a promising manufacturing solution to address the challenges posed by higher operating temperatures and/or pressures. This paper delves into three primary areas: the exploration of HPHT regimes supported by conventional heat exchangers, the impact of AM processes on thermal transport devices, and the discussion focused on HPHT heat exchangers produced via AM. The study examines the traditional manufacturing processes, materials, structures and geometries, and limitations of the commonly used heat exchangers for HPHT applications. Furthermore, it highlights the potential of AM in optimizing HPHT heat exchanger design, by reviewing studies that enable uniform flow distribution, minimization of fouling, and thermo-hydraulic performance augmentation without compromising structural stability. While addressing the limitations of cost, size, and other constraints, this study offers insights into the possibilities of AM in revolutionizing HPHT heat exchanger technology. The goal has been to fill the gap in literature by summarizing key studies, findings, and limitations, presenting a detailed examination, and proposing new areas for research. In conclusion, this review contributes to a deeper understanding of AM’s role in advancing HPHT heat exchangers for future energy systems.

36 MATERIALS SCIENCE↗

Binary Control Pulse Optimization for Quantum Systems

Quantum control aims to manipulate quantum systems toward specific quantum states or desired operations. Designing highly accurate and effective control steps is vitally important to various quantum applications, including energy minimization and circuit compilation. In this paper we focus on discrete binary quantum control problems and apply different optimization algorithms and techniques to improve computational efficiency and solution quality. Specifically, we develop a generic model and extend it in several ways. We introduce a squared L 2 -penalty function to handle additional side constraints, to model requirements such as allowing at most one control to be active. We introduce a total variation (TV) regularizer to reduce the number of switches in the control. We modify the popular gradient ascent pulse engineering (GRAPE) algorithm, develop a new alternating direction method of multipliers (ADMM) algorithm to solve the continuous relaxation of the penalized model, and then apply rounding techniques to obtain binary control solutions. We propose a modified trust-region method to further improve the solutions. Our algorithms can obtain high-quality control results, as demonstrated by numerical studies on diverse quantum control examples.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimum design of a gearbox for low vibration

A computer program was developed for designing a low vibration gearbox. The code is based on a finite element shell analysis, a modal analysis, and a structural optimization method. In the finite element analysis, a triangular shell element with 18 degrees-of-freedom is used. In the optimization method, the overall vibration energy of the gearbox is used as the objective function and is minimized at the exciting frequency by varying the finite element thickness. Modal analysis is used to derive the sensitivity of the vibration energy with respect to the design variable. The sensitivity is representative of both eigenvalues and eigenvectors. The optimum value is computed by the gradient projection method and a unidimensional search procedure under the constraint condition of constant weight. The computer code is applied to a design problem derived from an experimental gearbox in use at the NASA Lewis Research Center. The top plate and two side plates of the gearbox are redesigned and the contribution of each surface to the total vibration is determined. Results show that optimization of the top plate alone is effective in reducing total gearbox vibration.

Inoue, Katsumi↗

Analysis and design of fast flow liquid Li divertor for fusion nuclear science facility (FNSF) using coupled plasma boundary and LM MHD/heat transfer codes *

The SOLPS-ITER code is utilized to analyze the boundary plasma associated with a fast-flow lithium (Li) divertor configuration in the fusion nuclear science facility (FNSF) tokamak and identify operational regimes with acceptable divertor and core conditions. Plasma transport from the SOLPS-ITER code has been coupled with a liquid metal (LM) MHD/heat transfer code to model a Li open-surface divertor design and assess its impact on the scrape-off-layer (SOL) and core plasma performance. Simulations with only Neon (Ne) impurity seeding have been conducted to evaluate its impact on meeting FNSF design demands for the divertor and upstream plasma parameters. Simulation results indicate that Ne seeding significantly mitigates divertor heat flux but potentially reduces both upstream electron and main ion density due to fuel dilution. The combined application of Ne seeding and deuterium (D 2 ) puffing is required to satisfy the FNSF design requirements on upstream density ($n^{OMP}_{e,sep}$~1× 10 20 m -3 ) and divertor energy flux ($q^{Odiv}_{\bot,max}$<10 MW m -2 ). D 2 puffing plays a role in counteracting upstream density drops and augmenting energy and momentum losses through atomic and molecular processes. The inlet Li flow velocity is systematically varied across a wide range to identify acceptable flows and corresponding LM surface temperatures. This comprehensive analysis identifies the acceptable Li flow parameters, LM surface temperature, and emitted Li fluxes necessary to meet the major design constraints. The emitted Li fluxes exhibit minimal impact on the main plasma at surface temperatures up to approximately ~525 °C, corresponding emitted Li fluxes of up to φ Li ~2X10 23 atoms s -1 . Uncertainties in the Li emission processes from the surface are also investigated, primarily influencing Li loss in the lower surface temperature range (<525 °C), with simulation results indicating a minor impact on the divertor and upstream plasma. Conversely, evaporation predominantly drives the Li loss processes at higher surface temperature ranges (>525 °C), contaminating both the divertor and upstream plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Load Switching Group based Feeder-level Microgrid Energy Management Algorithm for Service Restoration in Power Distribution System

This paper presents a load switching group based energy management system (LSG-EMS) for operating microgrids on a distribution feeder powered by one or multiple grid-forming distributed energy resources. Loads on a distribution feeder are divided into load switching groups that can be remotely switched on and off. The LSG-EMS algorithm, formulated as a mixed-integer linear programming (MILP) problem, has an objective function of maximizing the served loads while minimizing the total number of switching actions. A new set of topology constraints are developed for allowing multiple microgrids to be formed on the feeder and selecting the optimal supply path. Customer comfort is accounted for by maximizing the supply duration in the customer preferred service period and enforcing a minimum service duration. The proposed method is demonstrated on a modified IEEE 33-bus system using actual customer data. Simulation results show that the LSG-EMS successfully coordinates multiple grid-forming sources by selecting an optimal supply topology that maximizes the supply period of both the critical and noncritical loads while minimizing customer service interruptions in the service restoration process.

Hu, Rongxing↗

Robust Scheduling of Networked Microgrids for Economics and Resilience Improvement

The benefits of networked microgrids in terms of economics and resilience are investigated and validated in this work. Considering the stochastic unintentional islanding conditions and conventional forecast errors of both renewable generation and loads, a two-stage adaptive robust optimization is proposed to minimize the total operating cost of networked microgrids in the worst scenario of the modeled uncertainties. By coordinating the dispatch of distributed energy resources (DERs) and responsive demand among networked microgrids, the total operating cost is minimized, which includes the start-up and shut-down cost of distributed generators (DGs), the operation and maintenance (O&M) cost of DGs, the cost of buying/selling power from/to the utility grid, the degradation cost of energy storage systems (ESSs), and the cost associated with load shedding. The proposed optimization is solved with the column and constraint generation (C&CG) algorithm. The results of case studies demonstrate the advantages of networked microgrids over independent microgrids in terms of reducing total operating cost and improving the resilience of power supply.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Optimal Control of the Energy-Saving Hybrid Hydraulic-Electric Architecture (HHEA) for Off-Highway Mobile Machines

Most off-highway constructions and agriculture equipment use hydraulics, which has unmatched power density, for power transmission and throttling as a means for control. A novel hybrid hydraulic-electric architecture (HHEA) has recently been proposed to improve efficiency for high-power machines that would have been cost-prohibitive to electrify directly. HHEA uses a set of common pressure rails (CPRs) to transmit the majority of power hydraulically and small electric motor drives to modulate that power and to achieve precise control. This article proposes a computationally efficient Lagrange multiplier method (LMM) for computing the optimal sequence of pressure rail selections to minimize energy use. This is needed to evaluate HHEA's energy-saving potential and for iterative architecture design and sizing. An interesting complication is that the cost function is not fully defined until the candidate control sequence is fully specified. This issue is dealt with by decomposing the original problem into a set of sub-problems with additional constraints that can be solved efficiently. Computational effort can be further reduced if actuators are optimized individually instead of together. However, additional steps are required to prevent the constraint functions from becoming discontinuous with respect to the Lagrange multipliers, which is necessary for meeting the constraints. Lastly, a case study of a construction machine demonstrates the efficacy of the method and shows that the HHEA reduces energy consumption by 68%-73% compared to the baseline load-sensing architecture.

Lagrange multiplier↗

Marine energy supported multi-energy system planning and operation optimization for sustainable coastal community

The growing need for sustainable energy solutions in coastal areas necessitates the development of integrated systems that leverage abundant marine resources. In this study, a standalone Marine Energy Supported Multi-Energy System (MRE-MES) is designed for sustainable coastal community development, utilizing renewable marine resources, including offshore wind, wave, and solar energy, to address the energy needs of electricity, heat, freshwater, and hydrogen. The proposed MRE-MES incorporates a co-optimization model that simultaneously balances capacity planning and operational efficiency to minimize costs and environmental impacts. The system is tested under different renewable energy penetration levels and demand uncertainties, using a two-stage stochastic programming to account for variability in renewable resources and consumption needs. The experimental results indicate that in the optimal system capacity configuration, the percentage of total renewable energy generation is around 80 %, with or without capacity limitation constraints on PV, water tank, and hydrogen storage. Compared to the worst-case scenario in Monte Carlo experiments, two-stage stochastic optimization results in a more robust decision that effectively mitigates the risks posed by future uncertain demand conditions. In conclusion, the findings highlight the viability of marine energy for providing a resilient, comprehensive energy solution to coastal communities.

Capacity planning↗

Minimum dissipation rates in magnetohydrodynamics

Minimum dissipation rate states are explored for a current-carrying channel of magnetofluid, supported by a dc magnetic field and driven by an applied electric field. The minimization is carried out subject to the constraints of constant axial (toroidal) magnetic flux and constant time-averaged rate of supply of magnetic helicity. The solutions of the resulting Euler-Lagrange equations are sensitive to boundary conditions on the current density j. One set of boundary conditions on j leads to the same consequences as Taylor's 'minimum-energy' theory. A different set leads to significantly different consequences, including a departure from the 'force-free' magnetic profile and a toroidal component of current density that does not reverse at the wall when the toroidal magnetic field reverses.

Montgomery, David↗

Coordinated Optimal Control of PV Inverters and HVAC Loads in Distribution Systems

The increasing integration of distributed energy resources (DERs), such as photovoltaics (PVs) and smart buildings into distribution systems complicate power system operation and controls. This paper proposes a coordinated optimal control strategy for PV inverters and Heating, ventilation, and air conditioning (HVAC) loads in smart buildings to minimize the total network loss in a distribution system. For the HVAC units, we enforce minimum on and off time constraints to avoid frequent switching that can degrade the unit. The proposed control will dispatch optimal control signals of active and reactive power to PV inverters and on/off commands to HVAC units while maintaining the nodal voltage within a secure range and the temperature of HVAC units at a comfort level. The simulation results on a modified IEEE 33-node distribution system demonstrate that the proposed coordinated control scheme can reduce the network loss.

Pani, Naveen↗