Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “conduit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Safeguards Technology Development Program. FY2021 Mid-Year Report, Encryption of Signal Pulses

Summary statement of work: Develop a signal pulse digital signing and encryption in-line device to verify signal integrity and point of origin for TTL pulse data used in IAEA systems, and to avoid the need for expensive tamper-indicating conduit or techniques. This device will be called Transparent Remote Encryption of Correlated Signals (TRECS). TRECS consists of two parts, a head end which is located in or near the detector assembly and a tail end that is located with the data acquisition electronics, i.e. MiniGrand, UMSR, UDL1 or JSR.

97 MATHEMATICS AND COMPUTING↗

Nondestructive Evaluation (NDE) of Cable Moisture Exposure using Frequency Domain Reflectometry (FDR)

This Pacific Northwest National Laboratory (PNNL) milestone report assesses the capability of frequency domain reflectometry (FDR) to determine electrical cable submergence using PNNL’s Accelerated and Real-Time Environmental Nodal Assessment (ARENA) cable/motor test bed. This work includes a review of relevant literature as well as experimental tests. Nuclear power facilities have experienced various electrical cable failures related to water exposure. The current industry response involves actions to de-water cable vaults, manholes, and other cable locations. These efforts require considerable expenditure of resources, which makes it desirable for the industry to have information on cable condition and history regarding their submergence and water exposure (Mantey 2012). Two tests that are gaining favor within the nuclear industry are time-domain reflectometry (TDR) and FDR. These are low-voltage nondestructive tests that can be applied at a cable end. Testing from the cable end is important because local inspection along the cable length is very difficult due to cables being routed within trays, conduits, underground, and through walls. Both TDR and FDR techniques have been shown to locate cable insulation damage due to thermal, radiation, and mechanical damage. FDR measurements are also more sensitive than TDR to temperature changes, low-bend radius bends, and cable contact with various materials, including conductive materials like steel and water. This work evaluates the feasibility to extend FDR testing to characterizing whether an electrical cable is submerged or not and where it may be submerged using PNNL’s ARENA cable/motor test bed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Conceptual Model Update of Mercury Sources and Flux at Y-12 and Upper East Fork Poplar Creek, Oak Ridge,Tennessee

The interactions between the key processes that control the fate and transport of mercury (Hg) in the sediments, groundwater, and stream water within the Y-12 National Security Complex (Y-12) in Oak Ridge, Tennessee are complex, and many aspects are not well understood. In contaminated environments such as Y-12, conceptual models are frequently developed to aid in visualizing and understanding the dynamic nature of the hydrologic, geochemical, and physical environment. These conceptual models integrate data in an internally consistent manner to understand processes that control the fate and transport of contaminants. Over the past few decades of environmental investigation at Y-12, a number of conceptual models have been developed to identify and define various technical processes at various scales. The main purpose of the activities described in this report is to update the 2011 conceptual model for Upper East Fork Poplar Creek using the most recent Hg concentration and flux data and informed scientific interpretation. Emphasis was placed on improving the previous model by implementing a more detailed spatial and temporal approach to visualize transport pathways in the watershed and trends in flux and concentration over time, and to compare baseflow and stormflow system dynamics. Detailed descriptions of historical and current Hg sources and transport pathways are also provided for the east and west ends of the facility. This conceptual model will allow the US Department of Energy to evaluate past and present remedial activities and provide a strong technical basis for prioritizing and optimizing remedial responses in a cost-effective and efficient manner. Twenty years ago, Hg flux from Outfall (OF) 200 at the headwaters of East Fork Poplar Creek represented approximately 20% of the overall flux leaving Y-12. By the time of the 2011 conceptual model report, that percentage had increased to 70%–80%. Flux estimates compiled for this report using data from 2009 to 2018 show that OF200 accounted for roughly 60% of the flux leaving Y-12. The relative role of the four storm drain conduits to OF200 appeared similar to 2011, with OF163 being the greatest contributor to downstream flux. An increase in Hg concentrations and flux occurred throughout and downstream of west end storm drains in 2011 in response to a storm drain cleanout. Leading up to the 2011 storm drain cleanout, annual baseflow flux was higher at OF200A6 than at Station 17. From 2011 to 2018, the trend reversed with concentrations and flux being higher at Station 17 than at OF200A6. A spike in concentrations occurred in July 2018, potentially due to a one-time influx of Hg that occurred during COLEX decontamination and decommissioning activities at Y-12. This report includes recommendations for improving our conceptual understanding of Hg sources, transport pathways, and flux at Y-12. Important recommendations include further evaluation of transport pathways, concurrent measurement of Hg concentration and flux under baseflow and stormflow conditions at multiple sites, and research to understand the connections among periphyton and methylmercury concentration, bioavailability, and bioaccumulation. Ongoing facility decontamination and decommissioning efforts, site characterization, remedial actions, and research are facilitating the collection of new Hg data at Y-12. The conceptual model update provided herein takes advantage of the extensive recent Hg sampling to provide an updated assessment of Hg mass balance and support a refined understanding of Hg behavior at or near Y-12. This assessment should assist in future environmental management decisions and in mitigating the impacts of Hg on the surrounding environment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fork Union EPC Installation Observation Report

On June 22nd and 23rd, a representative from Savannah River National Lab (SRNL) traveled to the Fork Union substation in Fork Union, Virginia (owned and operated by Dominion Energy) to observe the installation, calibration, and commissioning of three Electric Phenomena Cluster (EPC) sensors. The installation in its entirety included the physical securing of the EPC sensors by Dominion Energy, fiber optic cable (furnished by SmartSenseComm) being run in conduits and cable trays from the EPC sensor to the Optical Processing Unit (OPU) located in the substation switch house. The location of the EPC sensors, OPU, and cable routing can be seen in the figures included.

47 OTHER INSTRUMENTATION↗

Modular Security Apparatus for Managing Distributed Cryptography for Command-and-Control Messages on Operational Technology Networks (Module-OT)

Module-OT is a bump- in- the- wire solution acting as a secure conduit for data between devices or systems across a network. Using the latest in open-source cryptographic libraries, all defined communications undergo authentication, authorization, and encryption. The core system can be easily installed through industry standard processes, and the use of popular open-source packages allows for it to be customizable customized by the developer community or deployed in unique embedded environments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

NETL Plastic Pipes Project - June 2022 Progress Report

Plastic or composite pipelines have been the bane of the utility locating industry because conduits are neither conductive nor magnetic, which are the properties traditionally used to locate buried utilities. Ground penetrating radar (GPR) is an effective geophysical tool for locating plastic/composite pipeline where the resistive cover allows for adequate penetration of radar energy. However, GPR cannot be used in areas where the soil cover is conductive due to significant clay and/or salt content. This study takes a comprehensive look at near-surface geophysical methods that potentially are useful for locating buried plastic/composite pipelines, either singly or in combination with other geophysical methods. Specifically, this modeling study uses computational numerical methods to forward model the response of GPR, resistivity, seismic, and gravity gradiometry methods to plastic/composite pipelines for various scenarios including: (1) pipe diameters ranging between 2 in. to 12 in.; (2) burial depths ranging between 3 ft to 4 ft; (3) various degrees in contrast in physical properties (i.e., permittivity, elasticity, electrical resistivity, density); and (4) various experimental acquisition choices (e.g., GPR radar frequencies, seismic source frequency, electrode spacing).

47 OTHER INSTRUMENTATION↗

NARAC Meteorological Monitoring Tower Maintenance Report: Submarine Base Group Two, Sub Base New London NEWLBASE2 Tower

Comments: The roof-based tower is located on Building 17 on Naval Submarine Base New London. Tower installation date is unknown. A second GFCI outlet in-line with the standard GFCI in the logger enclosure is mounted on conduit out of the tower base pedestal. The roof surface has been replaced and is now safe to walk on. The tower was not climbed during this maintenance visit. After the maintenance visit in 2018, the tower was deemed unsafe to climb due to age, corrosion, and deterioration of the tower components. The wind, air temperature, and relative humidity sensors located on the upper part of the tower require climbing of the tower for servicing and could not be accessed for inspection and maintenance. The tower is scheduled for replacement in FY2023. Tasks to be Completed: Tower system replacement / relocation. Consider replacement or bypassing of the suspect precipitation gauge signal connector.

99 GENERAL AND MISCELLANEOUS↗

ROTOR: Research to Operations and Operations to Research

PNNL’s Research to Operations/Operations to Research (ROTOR) Program fosters a cybersecurity operations to researcher collaboration, identifying hard problems and challenges for cyber defenders and bringing researcher science disciplines to these challenges. ROTOR allows PNNL’s cyber defenders to better protect the laboratory but also fosters innovation and incubation of solutions for our sponsor missions across DOE, DOD, DHS and the intelligence community. Our sponsors and their missions are faced with many of the same cyber defense challenges that PNNL faces. By using our own laboratory security operations environment as an innovation generator and testing ground, allowing research to be tested and tried, our sponsors are directly benefitted. PNNL is in a unique position to combine our world class research organization with enterprise cybersecurity operations. ROTOR is taking advantage of this to bring PNNL cybersecurity research projects into an operational environment within PNNL’s Cyber Security Operations Center. With ROTOR, PNNL researchers gain the advantage of operational experience and expertise and have an avenue for showcasing research in an operational environment. This helps to advance PNNL research, prove operability of PNNL projects to its sponsors, and provide real-world insight to real-world problems for our cybersecurity research agenda. ROTOR is the conduit for PNNL cybersecurity research to find its way to operational use. PNNL researchers and engineers are informed by real-world operations and operations has access to current PNNL research and engineering capabilities. All of this leads to improved reputation for PNNL as a provider of national security solutions that are tried and tested. To date, ROTOR has collaborated with six projects, enabling each to conduct operational work within the CSOC.

97 MATHEMATICS AND COMPUTING↗

Hydropower Investment and Public-Private Ecosystem Assessment

The U.S. Department of Energy's (DOE's) Water Power Technologies Office (WPTO) commissioned this Report to evaluate the primary challenges in raising investment in medium-sized hydropower and PSH, defined as projects with five (5) to 30 megawatts (MW) of installed capacity, and to understand potential opportunities to increase mobilization of private sector investment in hydropower and PSH projects in the future. Based on stakeholder interviews, a market survey, and industry reports, this Report considers the investment and development trends and future opportunities for five hydropower project types: capacity additions, conduits, PSH (both open and closed loop), non-powered dams (NPDs), and new stream-reach development (NSD).

13 HYDRO ENERGY↗

LINAC Electrical Cabinets - Structural Analysis

Along LINAC s downstream path is a floor containing various cabinets above the LINAC. Of the dozens of cabinets are 4 specific cabinet types: PNF Modulator, PNF Power Supply, Water Skid, and Marx. Each of these cabinets may contain some of the various contents that include electronics, wiring, pipelines, circuits, and conduits. Lab Technicians perform maintenance and inspections of the cabinets and need to access every part, including the top section that is subject to the weight of the technician standing on top. To ensure the cabinet is structurally safe, a CAD model will be developed for each cabinet and a Finite Element Analysis (FEA) will be performed on each cabinet to confirm it is safe to stand on.

Blas, Efren↗

Assessment of Flow-Enhanced Electrochemical Sensor Testing and Deployments for MSRs

This report serves as the deliverable for Milestone M3RS-23AN0401061 that is part of Work Package RS-23AN040106 (Flow Enhanced Sensors for MSRs – ANL). The goal of this milestone was to determine performance of the flow enhanced electrochemical sensor (FEES) and modular flow instrumentation testbed (MFIT) in safeguards relevant scenarios. Flow enhanced electrochemical sensors are a type of electroanalytical sensor that has been developed at Argonne National Laboratory to be installed directly into MSR flow conduits to make measurements of the salt composition. These sensors represent a significant improvement in capabilities compared to earlier electroanalytical sensors that instead can only be operated in quiescent conditions. Previous work has focused on testing of the FEES in flowing conditions provided by the MFIT to assess the accuracy and precision of the sensor measurements. To further improve this capability, in FY23 we undertook a campaign of safeguards relevant scenarios in molten salt containing a range of uranium chloride concentrations (0 to 3 wt%). All the testing carried out in FY23 was aided by a control system designed to automatically actuate flow conditions and collect data. This new automation system is estimated to have increased experimental throughput by a factor of four and enabled testing in a variety of complex conditions. The advancements in throughput and repeatability led to improved quantification of actinide concentrations using the in-flow sensors, with a reduction of the mean absolute relative error from 5.6% in FY22 to 3.1% in FY23. In addition to safeguards scenarios run in the MFIT, FY23 work included deployment of a FEES at a partner institution where it will be tested in a flowing salt loop. The FEES was successfully integrated into that loop and is being tested prior to loop startup. In FY23, work also continued on the smaller flow system that we have named the mini-MFIT. This smaller system is capable of rapid prototyping of new sensor designs prior to installation in the larger MFIT radiological flow system. Work was carried out to test this new system in non-radiological molten salts in a separate glovebox. This work is helping us to enhance the accuracy of our salt monitoring capabilities through the integration of multiple types of sensors. The high degree of accuracy required by 10 CFR 74 represents a significant challenge, and further design evolution and integration of the sensors into multimodal sensing frameworks will be needed to further push the measurement accuracy to the needed level.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Assessment of Flow-Enhanced Electrochemical Sensor Testing and Deployments

The goal of our activities in FY24 was to enable advanced materials accountancy for molten salt reactors (MSRs) through the development and optimization of robust flow-enhanced electrochemical sensors (FEES) using a safeguards-focused sensor testing platform called the modular flow instrumentation testbed (MFIT). Flow-enhanced electrochemical sensors are a type of electroanalytical sensor that have been developed at Argonne National Laboratory to be installed directly into MSR flow conduits to make measurements of the salt composition. These sensors represent a significant improvement in capabilities compared to earlier electroanalytical sensors that instead can only be operated in quiescent conditions. Previous work has focused on testing of the FEES in flowing conditions provided by the MFIT to assess the accuracy and precision of the sensor measurements. This year, the FEES technical readiness was increased by (1) demonstrating the use of optimized sensor techniques to achieve measurements in very high-concentration MSR-relevant salts, (2) leveraging new multimodal sensors and automation approaches to reduce measurement uncertainties, and (3) fabricating and deploying sensors to industrial partners to improve their ability to make measurements in challenging environments. Additionally, we also ran the sensors during complex system operations involving combined flow and purification activities to demonstrate safeguards-relevant measurements during online processing for MSRs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Identification of Faults Susceptible to Induced Seismicity (Final Report)

Central to the work documented in this report is the capability of geocellular models to represent the geologic conceptual model updated with fault identification from machine learning and joint inversion modeling of microseismic data measured and recorded as a consequence of CO 2 injection at a field demonstration site: the Illinois Basin - Decatur Project (IBDP). This work required seven unique geocellular models with 100s of simulated variations to gain a very high degree of confidence in the identification of geologic features present that contributed to induced microseismicity at IBDP. All forward modeling: pressure modeling, stress modeling, and seismic modeling used the same geologic conceptual model and representations of that model at different scales. The pressure modeling and poroelastic modeling created “snapshots” of pore pressure and stress field changes at different times during CO 2 injection, in which microseismic events were clustered (in time). These pressure and stress snapshots, within the framework and architecture of the geologic conceptual model via the geocellular model, informed the single fault and fault network models to ascertain the likelihood of fault movement (seismic or aseismic). The outcomes of the pressure, stress, and fault/fault network (seismic) modeling confirmed that the faults in the geologic conceptual model in Task 2 were likely the source of microseismic events measured at IBDP and acted as conduits for pressure to be transmitted from the injection interval into the Precambrian crystalline basement rock. This closely coordinated and integrated unique modeling approach was conducted to prove the viability of our proposed workflow 1) to better resolve crystalline basement faults, 2) detect subseismic faults that could be activated by injection, 3) increase the certainty in fault detection and their susceptibility to release seismic energy, and 4) understand transmission of pressure vertically from the well to the underlying fractured crystalline basement. The proposed methodology was effective in guiding an iterative process of calibrating forward modeling results based on similar geocellular models while honoring the geologic conceptual model (i.e., characterization data and knowledge of regional geology); this led to higher level of certainty in the identification of fault/faults zones to control seismicity and transmission of pressure to the regions of recorded and located injection induced seismicity.

58 GEOSCIENCES↗

Flow Enhanced Electrochemical Sensor Performance in Complex Salt Systems

To advance MSR MC&A practices, Argonne National Laboratory developed and optimized robust flow enhanced electrochemical sensors (FEES) and multielectrode array voltammetry sensors (MAVS) which provide accurate near-real time measurements of actinides in molten salts. Flow-enhanced electrochemical sensors are installed directly into MSR flow conduits for inline salt chemistry measurement, while MAVS are deployed in quiescent salt conditions enabling online species concentration determination in stationary salt vessels. This report summarizes efforts to improve electrochemical sensor technological readiness through (1) sensor testing in complex, high concentration molten salt systems to demonstrate low uncertainty actinide measurements in MSR-representative solutions and (2) demonstrations of sensor performance in challenging real-world conditions in collaboration with partner MSR institutions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Center for Alternate Synchronization and Timing (CAST) PTP Network Monitoring Report

The Oak Ridge National Laboratory Center for Alternative Synchronization and Timing (CAST) performs research, development, testing, and evaluation of alternative terrestrial-based timing and synchronization infrastructure for the US power grid and other critical infrastructures. Alternative timing options reduce reliance on GPS and enhance the overall resilience of critical infrastructures. CAST infrastructure uses Precision Time Protocol (PTP) as the primary conduit for delivery of synchronization packets. CAST deploys PTP over long terrestrial links to synchronize a multitude of remote boundary clocks and downstream power grid components with the authoritative grand master clocks. Network traffic issues can severely degrade PTP accuracy. This report focuses on examining network traffic anomalies and their effects on PTP operation as well as the potential implications to CAST’s high-precision remote synchronization operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cost Analysis of Heavy-Duty Vehicle Proton Exchange Membrane Fuel Cell Stationary Power Plants

Heavy-duty PEM fuel cells could be a low-cost, low emission alternative to combustion turbines for re-electrifying hydrogen if used as part of a long duration grid energy storage systems. Many studies expect heavy duty PEM fuel cell production costs to reduce as manufacturing volumes ramp up and their expected durability of 25,000-30,000 hours aligns well with a 30-year life for hydrogen seasonal energy storage plants that would likely operate less than 10% of the year. The labor, material, and equipment costs associated with installing PEM fuel cells and their required balance of plant for stationary applications have not been thoroughly explored, however. This study performs a detailed design and cost analysis of a 100 MW stationary PEM fuel cell power plant, capturing costs such as cooling, power electronics, pipes, valves, fittings, cabling, conduit, concrete foundations, buildings, and land. It employs methods consistent with NLR's solar PV benchmarking cost analysis and annual technology baseline to derive the total installed costs of stationary PEM fuel cell plants that utilize heavy duty PEM fuel cells.

08 HYDROGEN↗

U.S. Hydropower Development Pipeline Data, 2026

The U.S. Hydropower Development Pipeline dataset provides a comprehensive, regularly updated view of proposed and potential hydropower projects across the United States. This resource compiles information from federal agencies and other public sources to track non-powered dams considered for electrification, proposed hydropower facilities at stream reaches with no existing dams, conduit exemptions, and emerging pumped storage hydropower proposals. The dataset includes project characteristics such as location, development status, technology type, ownership category, and other attributes that support analysis of future hydropower trends. It is designed to help researchers, planners, policymakers, and stakeholders assess national‑scale development patterns, understand the evolving hydropower landscape, and explore opportunities and challenges associated with new hydropower deployment. The dataset is updated annually to reflect changes in project status, new proposals entering the pipeline, and projects that are cancelled, completed, or otherwise removed from active consideration. Note: Capacity additions to existing hydropower plants are not included in this database due to reliance on a proprietary data source.

Johnson, Megan [ORNL] (ORCID:0000000290141741)↗

Investigation of Scale-Dependent Groundwater/Surface-water Exchange in Rivers by Gradient Self-Potential Logging: Numerical Modeling and Field Experiments

Exchanges of groundwater and surface-water are fundamental to a wide range of water-supply and water-quality management issues but challenging to map beyond the reach scale. Waterborne gradient self-potential (SP) measurements are directly sensitive to water flow through riverbed sediments and can be used to infer exchange locations, direction (gain versus loss), scale, and relative changes, but to date applications to river corridor hydrology are limited. Numerical modeling and field experiments were therefore performed herein, each emphasizing waterborne gradient SP logging for identifying and locating focused vertical groundwater discharge (surface-water gain) and recharge (surface-water loss) in a river. Two and three-dimensional numerical models were constructed to simulate the polarities, appearances, and peak amplitudes of streaming-potential and electric-field anomalies on a riverbed and in the surface-water that were attributable to steady-state vertical fluxes of groundwater through high-permeability conduits in the riverbed. Effects of varied hydraulic length-scale of exchange and surface-water depth were tested through numerical modeling. Modeling results aided in data acquisition and interpretation for three repeated field experiments performed along a 1.5–2.0 km reach of the Quashnet River in Cape Cod, Massachusetts, where focused, meter-scale groundwater discharges occur at discrete locations within otherwise ubiquitous and more diffuse groundwater upwelling conditions. Strong gradient SP anomalies were repeatedly measured in the Quashnet River at previously confirmed locations of focused groundwater discharge, showing the efficacy of waterborne gradient SP logging in identifying and characterizing groundwater/surface water exchange dynamics at multiple river network scales.

Engineering↗