Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “computed Tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Flash Thermal Diffusivity Measurements and Inspection of Additively Manufactured Ti-6Al-4V Specimens with Varying Process Parameters

Flash thermal diffusivity measurements were obtained on additively manufactured Ti-6Al-4V disk shaped specimens with various process parameters. For additively manufactured metal parts, processing parameters such as laser power and scanning speed are critical to ensure the desired microstructure. For this study, the laser powder bed fusion process parameters were changed at various angular sections on a 21 mm diameter and 3.0 mm thick disk. The measurement of thermal diffusivity was performed by fitting a 1-dimensional thermal model to the data pixel by pixel to produce an inspection image. The image revealed the detection of defects such as lack of fusion porosity and areas of aggregated porosity. The thermal diffusivity imagery was compared to immersion scan ultrasonic and X-ray computed tomography (CT) measurements for validation. Based on these results, additional samples were investigated using a single side thermal inspection technique to detect lack of fusion porosity and near surface voids.

thermal nondestructive evaluation↗

The Effect of Experimental Variables on Industrial X-Ray Micro-Computed Sensitivity

A study was performed on the effect of experimental variables on radiographic sensitivity (image quality) in x-ray micro-computed tomography images for a high density thin wall metallic cylinder containing micro-EDM holes. Image quality was evaluated in terms of signal-to-noise ratio, flaw detectability, and feature sharpness. The variables included: day-to-day reproducibility, current, integration time, voltage, filtering, number of frame averages, number of projection views, beam width, effective object radius, binning, orientation of sample, acquisition angle range (180deg to 360deg), and directional versus transmission tube.

X-ray Computed Tomography↗

Biaxial Braided Flared Cone Structural Analysis

Computed Tomography (CT) is a useful tool for performing structural analysis on polymer based materials due to its high precision and accuracy. CT data was taken of two flared cones made from carbon fiber and fiberglass. One of the flared cones is pictured below. The variation in braid angle throughout the part was measured using Avizo 3D modelling software while the variation in thickness throughout the part was determined using MATLAB. Samples of pictures from the process of each of these analyses are shown below. The overall goal of this analysis was to collect structural data relevant to future testing of the parts.

Computed Tomography↗

Assessment of Segmentation-Induced Deviations of Porosity Metrics in Powder Bed Fusion Additively Manufactured Components

Post processing X-ray computational tomography (CT) inspection data for additively manufactured (AM) components can induce deviations in defect quantification, affecting subsequent fatigue and failure predictions. To assess the influence and potential impact of segmentation-induced measurement deviations, this paper applies several segmentation techniques to X-ray CT data for powder bed fusion Ti-6Al-4V specimens exhibiting porosity conditions. X-ray CT reconstructions were segmented with varying techniques including Otsu’s thresholding, random forest, k-nearest neighbors, and the multilayer perceptron. Metrics such as pore size and global porosity were compared for internal validity. Then, top-down X-ray CT measurements of surface-breaking porosity were compared to optical profilometry for cross-validation.

Data fusion↗

Emplacement of Shergottites in the Martian Crust Inferred From 3D Petrofabric and Crystal Size Distribution Analyses

Shergottites are mafic to ultramafic igneous rocks that represent a majority of known martian meteorites. They are subdivided into gabbroic, poikilitic, basaltic, and olivine-phyric categories based on differences in mineralogy and textures. Their geologic contexts are unknown so analyses of crystal sizes and preferred orientations have commonly been used to infer where shergottites solidified. Such environments range from subsurface cumulates to shallow intrusives to extrusive lava flows, which all have contrasting implications for interactions with crustal material, cooling histories, and potential in situ exposure at the surface. In this study, we present a novel three-dimensional (3D) approach to better understand the solidification environments of these samples and improve our knowledge of shergottites’ geologic contexts. Shape preferred orientations of most phases and crystal size distributions of late-forming minerals were measured in 3D using X-ray computed tomography (CT) on eight shergottites representing the gabbroic, poikilitic, basaltic, and olivine-phyric categories. Our analyses show that highly anisotropic, rod-like pyroxene crystals are strongly foliated in the gabbroic samples but have a weaker foliation and a mild lineation in the basaltic sample, indicating a directional flow component in the latter. Star volume distribution analyses revealed that most phases (maskelynite, pyroxene, olivine, and oxides/sulfides) preserve a foliated texture with variable strengths, and that the phases within individual samples are strongly to moderately aligned with respect to one another. In combination with relative cooling rates during the final stages of crystallization determined from interstitial oxide/sulfide crystal size distribution analyses, these results indicate that the olivine-phyric samples were emplaced as shallow intrusives (e.g., dikes/sills) and that the gabbroic, poikilitic, and basaltic samples were emplaced in deeper subsurface environments.

Martian meteorites↗

Fabrication and Characterization of A Lunar Simulant-Based Sintered Construction Material

In-situ resource utilization (ISRU) is critical to enable future efforts to have a long-term human presence on the Moon as well as Mars. ISRU technologies are being developed for radiation protection, dust mitigation, thermal insulation, and other applications. One such ISRU technology for creating construction materials out of lunar and Martian regolith is sintering, which is a thermal-based construction process that bonds finely grained material together at temperatures below the melting point. However, the conditions employed during the sintering, such as temperature, atmospheric composition, duration of the process, and pressure, can have a significant impact on the quality and strength of the resulting materials. In parallel, the development of methods for characterizing the quality, porosity, density, and other properties of these materials is critical. X-ray computed tomography (X-ray CT) can image large changes in density within a material, such as the presence of pores throughout an otherwise uniform medium, with relatively high spatial resolution. Similarly, Terahertz time-domain spectroscopic (THz-TDS) imaging is sensitive to density variations within samples, but is restricted to non-conducting materials. Specifically, previous work has shown that the refractive index (n eff ) values obtained through the analysis of THz-TDS images increases with increasing density within plastic samples. Even further, this work showed that it is possible to create a calibration curve for a given material from samples of different, but known density, which can enable one to directly convert n eff to density for samples having the same composition, but unknown density. Here, we report on the fabrication of a lunar simulant-based sintered construction material using vacuum hot pressed (VHP) sintering, then show X-ray CT and THz-TDS imaging results of the sample, which show spatial variations in the material. This has important implications for efforts to improve these types of lunar construction material processes and verify the quality of these materials in terms of consolidation. To the best of our knowledge, there is no previous work utilizing VHP sintering to make lunar simulant-based construction materials or exploring the feasibility of THz imaging to spatially map the density variation through a lunar simulant-based construction material.

Terahertz time-domain spectroscopic imaging↗

Mineralogical, Elemental, and Tomographic Reconnaissance Investigation for CLPS (METRIC)

METRIC is a robotic science laboratory that can determine the mineralogy, elemental chemistry, micromorphology, and thermophysical properties of planetary regolith. The METRIC suite comprises METRIC XRD/F, an X-ray diffraction/X-ray fluorescence instrument that can determine the mineralogy and elemental chemistry of regolith samples; METRIC XCT, a micro X-ray computed tomography instrument that can be used to evaluate grain/crystallite sizes and textures; METRIC IRS, an imaging spectrometer mounted on a rover that can determine mineralogy and thermophysical properties at the landing site; and a pneumatic sample collection, processing, distribution system developed by Honeybee Robotics. The payload elements could be deployed on a static lander or a rover. Data returned from the METRIC payload would inform origin, formation, and evolution of rocky planetary bodies. METRIC XRD/F draws on heritage from the CheMin instrument on the Mars Science Laboratory (MSL) Curiosity rover [1], with a few important improvements. Like CheMin, METRIC XRD/F operates in transmission geometry and uses piezoelectric actuators on sample cells in a tuning fork geometry to induce convective grain motion of the regolith to create a randomly oriented powder. MSL CheMin uses an energy-sensitive CCD to collect XRD patterns and XRF spectra simultaneously from the same sample cell, resulting in qualitative XRF data. METRIC XRD/F uses two different sample cells, one optimized for XRD and one optimized for XRF, and a silicon drift detector to detect fluoresced X-rays. This improvement to the XRF capabilities provides quantitative geochemical data of major elements down to Z = 11 and allows for the detection of minor and trace elements that are critical for evaluating geologic evolution of the Moon (e.g., P and Th). Modest improvements to the XRD geometry and hardware allow for better angular resolution and the ability to distinguish between members of the pyroxene group. METRIC XCT uses the same geometry and much of the same hardware as METRIC XRD/F, where a CCD would capture images of a regolith sample in a 3 mm diameter sample tube that is rotated 360° in steps <1°. Image brightness can be used to infer compositional data, where brighter materials indicate a higher Z, much like scanning electron microscopy. Data from METRIC XCT complement those from METRIC XRD/F. Particle size, shape, and texture can provide petrologic and provenance information, whereas vesicle size and morphology in volcanic or impact melt lithologies can inform cooling rates. METRIC IRS is a hyperspectral thermal imager that can be mounted to a lander or rover to provide mineralogical data from the broader landing site and help determine whether the samples analyzed by METRIC XRD/F and XCT are representative. The METRIC IRS spectral range (8–14 μm) and resolution (10.8 cm-1) allow for quantitative mineralogy from modelling Reststrahlen bands of major rock-forming minerals (e.g., silicates, phosphates). Radiance cubes can be processed and modelled with an onboard high-performance computer to determine mineral abundances of plagioclase, high-Ca pyroxene, pigeonite, orthopyroxene, olivine, and glass. Regolith samples can be acquired, processed, and delivered to the X-ray instruments via multiple sample handling systems, but the pneumatic sampling systems developed by Honeybee Robotics [e.g., 2] are best suited for relatively low-cost missions that are being competed for the Moon (e.g., NASA’s Payloads and Research Investigations for the Surface of the Moon program). There are pneumatic sampling systems that collect surface material and other systems that pneumatically drill up to ~1 m below the surface, providing material that has not been space weathered and has not been affected by the lander’s exhaust. [1] Blake, D. F., Vaniman, D., Achilles, C., Anderson, R., Bish, D., et al. (2012). Space Sci. Rev. 170, 341-478. https://doi.org/10.1007/s11214-012-9905-1. [2] Zacny, K., Betts, B., Hedlund, M., Long, P., Gramlich, M., Tura, K., Chu, P., Jacob, A., Garcia, A. (2014). IEEE Aerospace Conference, 3-7 March 2014, Big Sky, MT, U.S.A.

X-ray diffraction↗

Risk of Bone Fracture due to Spaceflight-induced Changes to Bone

The Human Research Program (HRP) is taking a biomechanical approach to assessing subsequent fracture risk in active astronauts as a consequence of spaceflight exposure. Triennial testing of active and retired astronauts continues as Space Medicine monitors for a premature diagnosis of primary osteoporosis, which is associated with age-related bone loss and skeletal fragility. This updated 2023 Fracture Evidence Report has expanded the description of skeletal changes to capture the full effects of spaceflight on bone: • Recent analysis of fractures from health records of the full astronaut cohort, suggests an increased incidence rate of hip and spine fractures in astronauts following longer spaceflight duration flights compared to incident rates found in shorter duration flights. • Routine preflight-to-postflight surveillance by DXA (dual-energy x-ray absorptiometry) does not provide the full detection of loss and recovery in the long-duration (LD) astronaut nor the full recovery of hip trabecular bone. • The inclusion of hip quantitative computed tomography (QCT) in flight studies delineates effects of spaceflight, of countermeasures, and of post-flight recovery on cortical and trabecular bone parameters—some of which are verified predictors of hip fracture in the aged. • QCT detects and compares the distinct countermeasure effects of the pharmaceutical alendronate and of resistive exercise (on the Advanced Resistive Exercise Device, ARED) in specific cortical and trabecular bone sub-regions during spaceflight. • A published comparison of QCT-determined loss rates of hip trabecular bone in LD astronauts compared to terrestrial cohorts suggest that accelerated loss rates in trabecular volumetric BMD (vBMD) during spaceflight might be analogous to skeletal effects of accelerated loss rates in females due to menopause, potentially leading to disruptions in trabecular microarchitecture. • A dataset of finite element (FE) estimates of hip bone strength in aging terrestrial cohorts (spanning astronaut age-range) provides comparative context for changes in the FE of hip bone strength in LD astronauts, including comparison (force unit of newton) to percentiles (50th, 75th, and 100th) of sex-matched aged humans with hip fractures. • Risk of fracture, due to the mechanical overloading of bones, is being updated with IMPACT, the next-generation tool suite for probabilistic risk assessment (PRA) for exploration missions being created by the Exploration and Medical Capability Element (ExMC) at NASA. IMPACT is currently in development and will not be included in this 2024 update. The risk for fracture necessitates understanding the relationship between applied loads to bone and the biomechanical competence of bone. The Risk for Early Onset Osteoporosis focuses on the weakened condition of bone (including development of new technologies, measurements of novel skeletal attributes, translation of multiple measures to an index of bone fragility, and interpretations of data used to reflect a weakened bone), while the Risk for Fracture assesses factors that influence the probability an astronaut would encounter applied loads exceeding the biomechanical competence of bones, resulting in fracture. This Evidence Report combines the research gaps and tasks associated with both risks.

Fracture↗

Hindlimb unloading has a greater effect on cortical compared with cancellous bone in mature female rats

This study was designed to determine the effects of 28 days of hindlimb unloading (HU) on the mature female rat skeleton. In vivo proximal tibia bone mineral density and geometry of HU and cage control (CC) rats were measured with peripheral quantitative computed tomography (pQCT) on days 0 and 28. Postmortem pQCT, histomorphometry, and mechanical testing were performed on tibiae and femora. After 28 days, HU animals had significantly higher daily food consumption (+39%) and lower serum estradiol levels (-49%, P = 0.079) compared with CC. Proximal tibia bone mineral content and cortical bone area significantly declined over 28 days in HU animals (-4.0 and 4.8%, respectively), whereas total and cancellous bone mineral densities were unchanged. HU animals had lower cortical bone formation rates and mineralizing surface at tibial midshaft, whereas differences in similar properties were not detected in cancellous bone of the distal femur. These results suggest that cortical bone, rather than cancellous bone, is more prominently affected by unloading in skeletally mature retired breeder female rats.

NASA Discipline Musculoskeletal↗

Mineralization of collagen may occur on fibril surfaces: evidence from conventional and high-voltage electron microscopy and three-dimensional imaging

The interaction between collagen and mineral crystals in the normally calcifying leg tendons from the domestic turkey, Meleagris gallopavo, has been investigated at an ultrastructural level with conventional and high-voltage electron microscopy, computed tomography, and three-dimensional image reconstruction methods. Specimens treated by either aqueous or anhydrous techniques and resin-embedded were appropriately sectioned and regions of early tendon mineralization were photographed. On the basis of individual photomicrographs, stereoscopic pairs of images, and tomographic three-dimensional image reconstructions, platelet-shaped crystals may be demonstrated for the first time in association with the surface of collagen fibrils. Mineral is also observed in closely parallel arrays within collagen hole and overlap zones. The mineral deposition at these spatially distinct locations in the tendon provides insight into possible means by which calcification is mediated by collagen as a fundamental event in skeletal and dental formation among vertebrates.

NASA Discipline Musculoskeletal↗

Estimates of volumetric bone density from projectional measurements improve the discriminatory capability of dual X-ray absorptiometry

To determine whether estimates of volumetric bone density from projectional scans of the lumbar spine have weaker associations with height and weight and stronger associations with prevalent vertebral fractures than standard projectional bone mineral density (BMD) and bone mineral content (BMC), we obtained posteroanterior (PA) dual X-ray absorptiometry (DXA), lateral supine DXA (Hologic QDR 2000), and quantitative computed tomography (QCT, GE 9800 scanner) in 260 postmenopausal women enrolled in two trials of treatment for osteoporosis. In 223 women, all vertebral levels, i.e., L2-L4 in the DXA scan and L1-L3 in the QCT scan, could be evaluated. Fifty-five women were diagnosed as having at least one mild fracture (age 67.9 +/- 6.5 years) and 168 women did not have any fractures (age 62.3 +/- 6.9 years). We derived three estimates of "volumetric bone density" from PA DXA (BMAD, BMAD*, and BMD*) and three from paired PA and lateral DXA (WA BMD, WA BMDHol, and eVBMD). While PA BMC and PA BMD were significantly correlated with height (r = 0.49 and r = 0.28) or weight (r = 0.38 and r = 0.37), QCT and the volumetric bone density estimates from paired PA and lateral scans were not (r = -0.083 to r = 0.050). BMAD, BMAD*, and BMD* correlated with weight but not height. The associations with vertebral fracture were stronger for QCT (odds ratio [QR] = 3.17; 95% confidence interval [CI] = 1.90-5.27), eVBMD (OR = 2.87; CI 1.80-4.57), WA BMDHol (OR = 2.86; CI 1.80-4.55) and WA-BMD (OR = 2.77; CI 1.75-4.39) than for BMAD*/BMD* (OR = 2.03; CI 1.32-3.12), BMAD (OR = 1.68; CI 1.14-2.48), lateral BMD (OR = 1.88; CI 1.28-2.77), standard PA BMD (OR = 1.47; CI 1.02-2.13) or PA BMC (OR = 1.22; CI 0.86-1.74). The areas under the receiver operating characteristic (ROC) curves for QCT and all estimates of volumetric BMD were significantly higher compared with standard PA BMD and PA BMC. We conclude that, like QCT, estimates of volumetric bone density from paired PA and lateral scans are unaffected by height and weight and are more strongly associated with vertebral fracture than standard PA BMD or BMC, or estimates of volumetric density that are solely based on PA DXA scans.

Non-NASA Center↗

A two-year program of aerobics and weight training enhances bone mineral density of young women

Previous research suggests that physical activity may have a beneficial effect on bone mineral density (BMD) in women. This relationship was explored in a 2-year, randomized, intervention trial investigating the efficacy of exercise and calcium supplementation on increasing peak bone mass in young women. One hundred and twenty-seven subjects (ages of 20-35 years) were randomly assigned either to an exercise program that contained both aerobics and weight training components or to a stretching program. Calcium supplementation (up to 1500 mg/day including dietary intake) or placebo was given in a double-blinded design to all subjects. Spinal trabecular BMD was determined using quantitative computed tomography (QCT). Spinal integral, femoral neck, and trochanteric BMD were measured by dual X-ray absorptiometry (DXA) and calcaneal BMD by single photon absorptiometry (SPA). Fitness variables included maximal aerobic capacity (VO2max), and isokinetic muscle performance of the trunk and thigh. Measurements were made at baseline, 1 year, and 2 years. Sixty-three subjects (32 exercise, 31 stretching) completed the study, and all the measured bone parameters indicated a positive influence of the exercise intervention. There were significant positive differences in BMD between the exercise and stretching groups for spinal trabecular (2.5%), femoral neck (2.4%), femoral trochanteric (2.3%), and calcaneal (6.4%) measurements. The exercise group demonstrated a significant gain in BMD for spinal integral (1.3 +/- 2.8%, p < 0.02), femoral trochanteric (2.6 +/- 6.1%, p < 0.05), and calcaneal (5.6 +/- 5.1, p < 0.01) measurements. In contrast to exercise, the calcium intervention had no positive effect on any of the bone parameters. In regard to fitness parameters, the exercise group completed the study with significant gains in VO2max and isokinetic (peak torque) values for the knee flexion and extension and trunk extension. This study indicates that over a 2-year period, a combined regimen of aerobics and weight training has beneficial effects on BMD and fitness parameters in young women. However, the addition of daily calcium supplementation does not add significant benefit to the intervention.

Randomized Controlled Trial↗

Tomography by iterative convolution - Empirical study and application to interferometry

An algorithm for computer tomography has been developed that is applicable to reconstruction from data having incomplete projections because an opaque object blocks some of the probing radiation as it passes through the object field. The algorithm is based on iteration between the object domain and the projection (Radon transform) domain. Reconstructions are computed during each iteration by the well-known convolution method. Although it is demonstrated that this algorithm does not converge, an empirically justified criterion for terminating the iteration when the most accurate estimate has been computed is presented. The algorithm has been studied by using it to reconstruct several different object fields with several different opaque regions. It also has been used to reconstruct aerodynamic density fields from interferometric data recorded in wind tunnel tests.

Vest, C. M.↗

Current methods and advances in bone densitometry

Bone mass is the primary, although not the only, determinant of fracture. Over the past few years a number of noninvasive techniques have been developed to more sensitively quantitate bone mass. These include single and dual photon absorptiometry (SPA and DPA), single and dual X-ray absorptiometry (SXA and DXA) and quantitative computed tomography (QCT). While differing in anatomic sites measured and in their estimates of precision, accuracy, and fracture discrimination, all of these methods provide clinically useful measurements of skeletal status. It is the intent of this review to discuss the pros and cons of these techniques and to present the new applications of ultrasound (US) and magnetic resonance (MRI) in the detection and management of osteoporosis.

Review, Academic↗

Multiscale and Multifidelity Modeling of a 3D Woven Composite Thermal Protection System

Complex three-dimensional (3D) woven composites have been considered by multiple NASA projects in recent years as a means of offering improved mechanical and thermal performance over traditional laminated composite systems. Parallel efforts have focused on developing simulation capabilities for these systems, which have traditionally and heavily relied on experimental testing to evaluate composite performance. One system is the Heatshield for Extreme Entry Environment Technology (HEEET), which is being considered for the thermal protection system on reentry spacecraft. Optical microscopy was used to characterize the blended carbon and phenolic fiber tows. A section of HEEET insulation layer was imaged with high-resolution micro-computed tomography (microCT) and segmented to separate individual tows, porous matrix, and voids. These data were used to develop multiscale thermomechanical computational models within the NASA Multiscale Analysis Tool (NASMAT). Two NASMAT modeling approaches were considered to capture the details of the 3D woven architecture: a coarse model appropriate for inclusion in multiscale structural analyses and a high-fidelity model created by downsampling the microCT data. Both elastic and thermal properties were computed and compared. The feasibility and challenges associated with modeling complex, hybrid 3D woven composites were also addressed.

NASMAT↗

A CAD Approach to Integrating NDE With Finite Element

Nondestructive evaluation (NDE) is one of several technologies applied at NASA Glenn Research Center to determine atypical deformities, cracks, and other anomalies experienced by structural components. NDE consists of applying high-quality imaging techniques (such as x-ray imaging and computed tomography (CT)) to discover hidden manufactured flaws in a structure. Efforts are in progress to integrate NDE with the finite element (FE) computational method to perform detailed structural analysis of a given component. This report presents the core outlines for an in-house technical procedure that incorporates this combined NDE-FE interrelation. An example is presented to demonstrate the applicability of this analytical procedure. FE analysis of a test specimen is performed, and the resulting von Mises stresses and the stress concentrations near the anomalies are observed, which indicates the fidelity of the procedure. Additional information elaborating on the steps needed to perform such an analysis is clearly presented in the form of mini step-by-step guidelines.

Abdul-Aziz, Ali↗

An Overview of Research in Nondestructive Evaluation at the National Aeronautics and Space Administration’s Langley Research Center

The primary focus of the nondestructive evaluation (NDE) effort at Langley Research Center (LaRC) is to pioneer advances in NDE and structural health monitoring (SHM) through fundamental scientific research, technology development, and transferring these to the scientific and aerospace communities. This research supports a variety of NASA missions in space operations, exploration and aeronautics. The work presented will focus on the development of advanced inspection systems to detect critical flaws in both metallic and non-metallic materials and structures for aerospace applications. The emphasis is on increasing the performance of inspection systems to provide defect detection and quantitative characterization of the material state. LaRC NDE utilizes expertise in computational ultrasonic, thermal and eddy current simulations to reduce measured responses to size and locations of flaws, establish technique limitations and optimize performance. This presentation will highlight research into five strategic areas: (1) The development of novel solutions using state-of-the-art NDE technologies such as eddy current, ultrasound, thermography and x-ray computed tomography; (2) Research in the development of unique NDE technologies such as terahertz, wavefield imaging and nonlinear ultrasound; (3) The application of both computational and analytic models to NDE problems; (4) The development of advanced analytic methods to interpret large complex data sets; and (5) Advanced methods of applying and interrogating sensors for structural health monitoring.

K Elliott Cramer↗

An Overview of Research in Nondestructive Evaluation at the National Aeronautics and Space Administration’s Langley Research Center

The primary focus of the nondestructive evaluation (NDE) effort at Langley Research Center (LaRC) is to pioneer advances in NDE and structural health monitoring (SHM) through fundamental scientific research, technology development, and transferring these to the scientific and aerospace communities. This research supports a variety of NASA missions in space operations, exploration and aeronautics. The work presented will focus on the development of advanced inspection systems to detect critical flaws in both metallic and non-metallic materials and structures for aerospace applications. The emphasis is on increasing the performance of inspection systems to provide defect detection and quantitative characterization of the material state. LaRC NDE utilizes expertise in computational ultrasonic, thermal and eddy current simulations to reduce measured responses to size and locations of flaws, establish technique limitations and optimize performance. This presentation will highlight research into five strategic areas: (1) The development of novel solutions using state-of-the-art NDE technologies such as eddy current, ultrasound, thermography and x-ray computed tomography; (2) Research in the development of unique NDE technologies such as terahertz, wavefield imaging and nonlinear ultrasound; (3) The application of both computational and analytic models to NDE problems; (4) The development of advanced analytic methods to interpret large complex data sets; and (5) Advanced methods of applying and interrogating sensors for structural health monitoring.

NDE↗