Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “compressed air”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

T2Well/EOS7NC (EOS7NC) v1.0Beta

T2Well/EOS7NC extends TOUGH2/EOS7C to include the choice of any three of a variety of non-condensable gas components and adds the coupled well-reservoir capability of T2Well. T2Well/EOS7NC is applicable to geologic carbon sequestration, CO2-enhanced gas recovery, compressed air energy storage, geologic hydrogen storage, and other subsurface porous-media injection/withdrawal processes involving non-condensable gases. The advantage of T2Well/EOS7NC over TOUGH2/EOS7C is that TOUGH2/EOS7C is restricted to modeling CO2 or N2, a gas tracer, and CH4 whereas T2Well/EOS7NC can model and three non-condensable gas components chosen from a long list within the code. In addition, T2Well provides the coupled well-reservoir capability.

Oldenburg, Curtis↗

Energy Storage Cost and Performance Database

In support of the U.S. Department of Energy’s Energy Storage Grand Challenge, Pacific Northwest National Laboratory is applying its rich history of battery research and development to provide the U.S. Department of Energy (DOE) and industry with a guide to current energy storage costs and performance metrics for various technologies. Cost and performance metrics for individual technologies track the following to provide an overall cost of ownership for each technology: cost to procure, install, and connect an energy storage system; associated operational and maintenance costs; and end-of-life costs. These metrics are intended to support DOE and industry stakeholders in making sound decisions about future R&D directions and priorities that move the United States closer to its goal of energy independence. The technologies currently being evaluated are lithium-ion [lithium iron phosphate (LFP) and nickel manganese cobalt (NMC)] batteries, vanadium redox flow batteries, lead-acid batteries, zinc-based batteries, hydrogen energy storage, pumped storage hydropower, gravitational energy storage, compressed air energy storage, and thermal energy storage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced sorbents for modular oxygen production for REMS gasifiers

Under a DOE funded effort, Thermosolv LLC has been developing a sorbent-based oxygen production technology for gasification and oxy-combustion applications. The sorbents utilize oxygen-storage properties of certain perovskites to (1) selectively adsorb oxygen at moderate temperature from compressed air and (2) release the adsorbed oxygen into a vacuum or a sweep gas such as CO2 and/or steam. Through cyclic operations of multiple sorbent beds such a process can be made continuous. Pressure drop across the sorbent bed and other similar design considerations dictate that the sorbent be in the form of a high surface-area-to-volume pellet and yet still possess sufficient crush strength and integrity. Process efficiency is determined by the sorption and desorption kinetics and sorbent capacity. Typical process involves cycle times in the order of 100 seconds, a time too short to fully utilize the full volume of the sorbent and the sorption capacity of the sorbent pellets. As a part of this project, Thermosolv LLC undertook the development of oxygen sorbents as a high-surface area supported sorbent on a light-weight inert support to (1) reduce the cost, (2) increase the productivity, and (3) reduce the overall weight of the reactor. Using a previously developed perovskite (LSCF 1991) with its well-characterized performance, composite sorbent pellets each consisting of an inert core coated by a thin layer of the functional perovskite material were produced. Several low-density, inexpensive inert solids supports in the 1/8”-1/4” size were selected to keep the pressure drop across the sorbent bed in the acceptable range. A number of commercial technologies including spray coating, dip coating, incipient impregnation of porous substrate followed by thermal annealing at various temperatures and duration were employed and tested to produce robust composite supported sorbent pellets. A sense of optimum coating thickness was developed by testing sorbent pellets of various increasing diameter pellets. LSCF-1991extrudates ranging in size from 1/32” to 3/16” were tested in a TGA and in a fixed-bed pressure swing test set-up for sorption/desorption cycles of interest. The data show that for the operational conditions of interest the coating thickness for a supported sorbent pellet needs to be approximately 1/32” (about 0.8 mm). Subsequent work thereby concentrated on developing composite pellets of various substrates, shapes and sizes with coating layer of about this size range. Candidate support materials were chosen based on cost, inertness, mechanical strength, thermal expansion and chemical stability with sorbent material, and in a size range to give an acceptable pressure drop in fixed-bad reactor configurations. Coating application methods used for application of the sorbent onto the support included precipitation, spray coating and dip coating from sorbent slurries and sol gels. For all coated supports where we could successfully apply a uniform coating of desired thickness with an acceptable handling performance in terms of exfoliation, TGA-based cyclic sorption/desorption testing was performed to determine cycling capacity of oxygen. Among nearly twenty different support materials tested, best adhesion performance was obtained from stainless saddle supports. In the bench-scale fixed-bad tests stainless steel saddle support composite pellets with a coating thickness in the 0.6 mm or so range, the composite sorbent pellet performance approached up to 95% of that of the 2 mm parent material pellets. In a parallel approach to reducing the cost of the sorbent, alternate sorbent formulations replacing/reducing the amount of cobalt in the LSCF family were also investigated. Successful formulations that could match the performance of LSCF 1991 were identified based on TGA cyclic tests as LSCF 1919 and LSF 1910. In the range of operational envelop of cycle times and other relevant process operating conditions, the reduced Co formulations showed comparable performance in the bench-scale fixed-bad cyclic operations. As a part of this project, we also attempted substitution of La and Sr with Ca and Ba, and Co with Mn, Ni and Cu with little success, but the overall project goal of reducing sorbent cost in terms of raw material and manufacturing expenses was successful.

01 COAL, LIGNITE, AND PEAT↗

USAID Grid-Scale Energy Storage Technologies Primer

This work provides an overview and compares key operating characteristics of select energy storage technologies. This work explores how these storage technologies may be used to improve the flexibility and reliability of power systems given their technical characteristics. The report covers various electrochemical (lithium-ion, lead-acid, flow, sodium-sulfur), chemical (hydrogen), mechanical (pumped hydro storage, compressed air energy storage, flywheels, gravity) and electrical (supercapacitors) storage mediums.

25 ENERGY STORAGE↗

West Virginia University Industrial Assessment Center (Final Progress Report)

The Industrial Assessment Center at West Virginia University has been successful in workforce development, and in generation of energy savings for manufacturing facilities during the period 2016 to 2021. Graduate and undergraduate students have benefited from energy assessment experience and most of them have found good positions as energy engineers and analysts in the industrial sector. Several peer reviewed research papers in archival journals as well as conference papers on the topic of energy engineering and assessment have been published. The implemented energy savings for manufacturing facilities have been significant in the areas of lighting, compressed air, process heating, steam, HVAC, chillers and cooling towers, and motors. In addition, water use reduction, smart manufacturing applications to save energy, cyber security evaluation, energy management, productivity improvements and waste reduction opportunities that lead to energy intensity reductions have been explored. The students have obtained an opportunity to interact with energy efficiency and productivity improvement professionals at various conferences and workshops and their research has generated important results. In summary, the West Virginia University Industrial Assessment Center (WVU-IAC) has fulfilled its mission in regard to workforce development, energy efficiency for manufacturing facilities, and laid a strong platform enhancing sustainability through reductions in carbon emissions achieved through energy efficiency and energy management initiatives and reductions in water usage and waste reduction. During the project period (2016-2021) the WVU-IAC has made numerous energy efficiency, water use reduction, waste reduction, and productivity improvement recommendations, a significant number of them having been implemented by the manufacturing facilities. The research adds significant understanding to the area of energy efficiency, water and waste reduction, and productivity improvement. The technical effectiveness and economic feasibility of the methods and techniques investigated and demonstrated through this project have been exemplary, resulting in significant recommended and implemented resource savings and reductions in carbon emissions. The project has been of significant benefit to the public owing to replication of results within the industrial sector, thus reducing operating costs for businesses that result in increase of growth and employment, as well as community benefits in terms of reductions in carbon emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technology Strategy Assessment: Findings from Storage Innovations 2030 Thermal Energy Storage

The concept of thermal energy storage (TES) can be traced back to early 19th century, with the invention of the ice box to prevent butter from melting. Modern TES development began with building heating and cooling and concentrated solar thermal technologies for power generation in the early 1900s and late 1970s, respectively. TES systems provide many advantages compared with other long-duration energy storage (LDES) technologies, which include low costs, long operational lives, high energy density, synchronous power generation capability with inertia that inherently stabilizes the grid, and the ability to output both heat and electricity. TES Use Cases TES technologies can couple with most renewable energy systems, including wind, photovoltaic, and concentrated solar thermal energy, and can be used for heat-to-heat, heat-to-electricity, electricity-to-heat, and electricity-to-electricity (bidirectional electricity) applications. The three types of TES that have heat as an input or output are grouped together for the purposes of this report. Retrofitting retired thermal power plants can be a potential cost-effective option for TES with electricity output because they both use a similar thermal-to-electricity type of conversion. Additionally, TES can directly serve heat demand for buildings and industrial processes, displacing fossil fuels to achieve broad decarbonization. Bidirectional Electricity Figure 1 shows a bidirectional electricity TES (ETES) architecture that is emerging as a prime technology for LDES at a grid scale. The ETES technology can utilize existing TES technology infrastructures, has no geological limitations (such as mountains and water for pumped storage hydro, underground natural caverns for compressed-air energy storage, etc.), and is capable of deployment anywhere in the United States and the world for broad uses. Particularly, ETES technology can be placed at retired fossil-fueled thermal power plants to reuse decommissioned assets, protect job security in associated communities, and provide resilient and high-inertia (i.e., spinning) power to the grid. Heat Input and Output There also are many ways to integrate TES within heat-to-electricity, heat-to-heat, and electricity-to-heat applications, such as those used in concentrating solar power (CSP), buildings, district heating, and industry process heat applications. These categories can be further classified for low- and high-temperature applications. High-temperature thermal energy storage (HTTES) heat-to-electricity TES applications are currently associated with CSP deployments for power generation. TES with CSP has been deployed in the Southwestern United States with rich solar resources and has proved its value to the electric grid. Electricity-to-heat and heat-to-heat HTTES applications present great potential for decarbonizing energy-intensive industrial process heat applications [8, 9], such as iron ore processing, iron smelting, cement production, glass manufacturing, mineral processing, and chemical production. Some industrial processes require process heat at temperatures > 1,400°C, so HTTES can be utilized to reduce fuel consumption in those processes through fuel, oxidizer, and process material pre-heating. Thermal energy storage for augmenting existing industrial process heat applications makes a much more attractive economic case because the energy penalty due to thermal-to-electric conversion is eliminated. Co-located applications of power production and heat also can add to the value stacking of integrating utility-scale TES; however, these scenarios are very case specific and not practically possible in many cases. These constraints are primarily attributed to the existing infrastructure being designed, developed, and constructed for many decades around the most economically feasible technologies, such as electricity and a selection of fossil fuels for heat input. Low-temperature TES can be utilized for building and district heating and cooling, as well as some process heat applications in electricity-to-heat and heat-to-heat configurations. Lower temperature TES (LTTES) can be added to heat pump equipment (electric input), either directly interacting with the refrigerant in the condenser or evaporator, or through a secondary heat transfer fluid. It also can be integrated in the building envelope or within the ducts of the heating, ventilation, and air conditioning (HVAC) system. Cost-effective integration of TES into buildings adds significant cost, and it is one of the key barriers preventing the commercialization and deployment of TES. The optimal strategy for integrating TES with buildings has yet to be determined for various applications of TES. Nevertheless, thermal storage materials are far less costly per unit of energy stored than electricity storage materials. This means that thermal storage has the potential to reduce the cost to society of energy storage.

25 ENERGY STORAGE↗

Spent Crystalline Silicotitanate Storage Study

Washington River Protection Solutions is working to support initial production of immobilized low-activity waste (LAW) by feeding Hanford tank supernate from tank farms to the Hanford Waste Treatment and Immobilization Plant (WTP) LAW Facility. This goal incorporates the design of a Tank-Side Cesium Removal (TSCR) system, which filters tank waste supernate to remove suspended solids and then removes Cs by processing it through crystalline silicotitanate (CST) ion exchange media manufactured by Honeywell UOP, LLC. The 137 Cs-depleted product is intended to be sent to the WTP for vitrification. The Cs-loaded CST columns will be stored indefinitely, with a goal of eventual CST removal and treatment. Thus, the spent CST needs to be recoverable. The testing described herein looks to potential upset process conditions where CST storage may be required before various rinse steps are completed. This study evaluated upset conditions at three sequential processing steps envisioned for TSCR (feed, 0.1 M NaOH rinse, water rinse), and in-column drying with compressed air (normal end step) to assess impacts on the nature of the CST bed. Testing was conducted at the small scale (12-mL bed volume); simulated AP-105 tank waste was used as the feed. Following process disruption, the CST bed was dried in place at 70 °C. Post-dried CST bed physical properties (angle of repose, penetration depth, particle morphological changes) were measured to evaluate how CST moved and flowed. The testing is intended to provide a preliminary assessment of issues that may arise from desiccation of CST with the indicated salt solutions in place. Since these were small-scale tests, the processing conditions will not match full scale conditions exactly; however, the tests do provide insight into the impact of stopping processing at an earlier step than normal. Except for the feed that was dried in-place, all other process stop-conditions showed the CST bed flowed well after drying. At this small scale, CST beds would not present an issue for retrievability. The feed that was dried in place had solidified into a rock-hard monolith with no movement possible. Samples had to be chipped from the surface.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Final Technical Report: Center for Mechanistic Control of Unconventional Formations

The overarching mission of the Center for Mechanistic Control of Unconventional Formations (CMC-UF) was to garner cross-cutting, fundamental, geoscience knowledge to achieve mechanistic control over the strongly coupled nonequilibrium physical and geochemical processes in extreme geological environments including shale, mudstone, marls, and other tight rocks with nanoscale pores. Collectively, these are referred to as unconventional formations and they often play the role of seals for other subsurface storage formations. The fundamental knowledge garnered by CMC-UF enabled science-based management of US unconventional formations for subsurface storage of carbon dioxide and TWh quantities of renewable energy as hydrogen and/or compressed air over longer timeframes as well as for natural gas production, with reduced environmental impacts, in the short term.

58 GEOSCIENCES↗

Controls Status for Fermilab’s PIP-II Project

Testing of Cryomodule first articles at PIP-II's on-site Cryomodule Test Facility (CMTF), where EPICS based controls are already being used, has been invaluable to the project. In addition to validating hardware and controls components, it has provided opportunities to build buy-in and illicit meaningful feedback early-on. A device naming convention has also been significantly refined with an internal working group and the PIP-II integration team. Compressed air and Process Control Water (PCW) systems have been installed, and operations has been engaged in Phoebus display development in preparation for a transition to operations for these systems by 2026. Cryoplant hardware has been put in place, and collaboration between controls and PIP-IIs cryo group for IOC and display development is well underway for commissioning of cryoplant systems to begin early 2026. The project has also received beneficial occupancy of the High-Bay Building in October 2025, keeping us on schedule for Warm Front End commissioning to begin in 2027.

Crisp, Dan [Fermilab]↗

Resource Adequacy and Capital Cost Considerations Pertaining to Large Electric Grids Powered by Wind, Solar, Storage, Gas, and Nuclear

The capacity and generation of wind, solar, storage, nuclear, and gas are estimated for large, idealized copper-plate electric grids. Wind and solar penetrations of 30% to 80% are considered together with different storage systems such as vanadium and lithium-ion batteries, pumped hydroelectric, compressed air, and hydrogen. In addition to a baseline dispatchable fleet without wind/solar, two bounding cases with wind/solar are analyzed: one without storage and one where the whole wind/solar fleet is connected to the storage system, hence providing a buffer between the wind/solar fleet and the grid. The reality will likely be somewhere between these bounding cases. The viability of a power grid with a large wind/solar penetration and no storage is not guaranteed but was nonetheless considered to provide a lower-bound capital cost estimate. Overall, the options that rely strongly on wind, solar, and storage could be significantly more capital-intensive than those that rely strongly on nuclear, depending on the amount of storage necessary to ensure grid stability. This is especially true in the long run because wind, solar, and storage assets have shorter lifetimes than nuclear plants and, consequently, need to be replaced more frequently. More analyses (e.g., grid stability and public acceptance) are necessary to determine which option is most likely to provide the path of least resistance to powering a clean, affordable, and reliable grid in a timely manner. Depending on the priorities, the path of least resistance may not necessarily be the one that is less capital intensive.

adequacy↗

Device disconnects several couplings simultaneously

Actuator assembly disconnects electric cable and fluid-line coupling from a rocket. The disconnector incorporates interconnected hydraulic cylinders which effect an equal and simultaneous displacement of pistons upon admission of compressed air through a solenoid control valve.

Forsythe, A. K.↗

Die and telescoping punch form convolutions in thin diaphragm

Die and punch set forms convolutions in thin dished metal diaphragm without stretching the metal too thin at sharp curvatures. The die corresponds to the metal shape to be formed, and the punch consists of elements that progressively slide against one another under the restraint of a compressed-air cushion to mate with the die.

Source record↗

Extendable mast used in one shot soil penetrometer

Penetrometer to test soil characteristics has a piercing head with soil instrumentation equipment attached to an expandable mast actuated by compressed air. The penetrometer gives continuous measurements as the mast pushes the piercing head through the soil.

Hotz, G. M.↗

Tool permits damage-free removal of solar cell

Modified soldering iron extracts a wrap-around solar cell that is attached with solder or adhesive to a substrate without destroying the cell removed or damaging adjacent cells. Heat, vacuum, and compressed air, operated from a special head attached to the soldering iron, loosen, extract, and protect the cell.

Beckley, J. E., Jr.↗

Ballast barge concept for underwater structures

Ballast barge for underwater structure consists of a reinforced concrete structure partitioned into watertight compartments. The barge structure includes a 3-way venting valve, a compressed air manifold, a master valve for connecting the manifold to an air line, and an open port in each compartment for admitting and expelling sea water.

Payne, V. E.↗

Plating by glass-bead peening

Technique permits plating of primarily metallic substrates with either metals or nonmetals at normal temperature. Peening uses compressed air to apply concurrent streams of small glass beads and powdered plating material to the substrate.

Babecki, A. J.↗

Computer program for predicting symmetric jet mixing of compressible flow in jets

Finite-difference computer program has been developed for treating mixing of two parallel and compressible air streams; one of them may be supersonic. This development is restricted to symmetric jet mixing in which high-speed jet is located on axis of channel and no provision is made for blowing or suction along channel walls.

Gilbert, G. B.↗