Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coaxial”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Plasma state in a coaxial accelerator.

Electron temperature and density distributions for helium plasma produced in coaxial accelerator measured spectroscopically, checking thermal equilibrium assumption

PLASMA DENSITY↗

Coaxial Compound Helicopter for Confined Urban Operations

A rotorcraft was designed for military operations in a confined urban environment. The specifications included major increases in useful load, range, and speed relative current aircraft capabilities, with a size constraint based on the dimensions of urban streets and intersections. Analysis showed that this combination of requirements is best satisfied by a coaxial main-rotor configuration, with lift compounding to off-load the rotors at high speed, and ducted fans under the rotor disk for propulsion. The baseline design is described, and the aircraft performance is summarized for utility, attack, MEDEVAC, and cargo delivery missions. The impact on size and performance is examined for a number of excursions, including lift-offset main rotors. Technology development required to achieve this advance in capability is recommended.

Urban Operations↗

Uncertainty Analysis of Coaxial Thermocouple Calorimeters Used in Arc Jets

Recent introduction of Coaxial Thermocouple type calorimeters into the NASA Ames arc jet facilities has inspired an analysis of 2D conduction effects internal to this type of calorimeter. Lateral conduction effects violate the 1D finite slab inverse analysis which is typically used to deduce the heat transfer to such calorimeters. The spherical shaped nose associated with most calorimeters (rather than flat) leads to a bias error that over-estimates the stagnation heating. Non-uniform heating on the face of spherically shaped calorimeters leads to conduction losses to the colder rim of the calorimeter which causes an underestimate of the stagnation heating. These two effects come into play at different times of the calorimeter's exposure to the arc jet, so they do not cancel. The spherical body effects come into play in the early stages of exposure, while the non-uniform heating effect becomes most severe at the later stages of exposure. The bias associated with spherical effects can be avoided by rewriting the 1D finite slab inverse analysis code to solve for 1D conduction in spherical coordinates. However, reducing the bias error associated non-uniform heating requires a somewhat ad hoc modification to the 1D finite element inverse analysis.

Isotherms↗

Coaxial Rotor Flow Phenomena in Forward Flight

Coaxial rotors are nding use in advanced rotorcraft concepts. Combined with lift offset rotor technology, they offer a solution to the problems of dynamic stall and re-verse ow that often limit single rotor edgewise forward ight speeds. Lower tip speed means reduced high-speed impulsive noise. The need for an anti-torque tail rotor is eliminated, a major boon during operation in conned areas. However, the operation of two counter-rotating ro-tors in close proximity generates many possibilities for aerodynamic interactions between rotor blades, blades and vortices, and between vortices. The parameter de-sign space is very large, and requires efcient computations as well as basic experiments to explore important physics to determine performance, loads, and acoustics. Computations are done on the classic HarringtonDingeldein rotor test case from the 1950s using the ROTUNS Navier Stokes code. Two regimes are explored: very low advance ratio as a perturbation from hover, and high advance ratio. Flow eld properties from RotUNS are used with 2-D OVERFLOW computations to capture blade crossing effects including those of higher subsonic Mach numbers. Bladeblade and bladevortex intersection events are captured using a MatLab-based predictor.

Flow Phenomena↗

Extraction of Dynamic Inflow Models for Coaxial and Tandem Rotors from CFD Simulations

The dynamic inflow coupling with rotor/body dynamics is crucial in the analysis of stability and control law design for helicopters. Over the past several decades, finite-state inflow models for single rotor configurations in hover, forward flight, and maneuver have developed (Ref.1-3). By capturing the interference effects between rotors, the extension of pressure potential finite state inflow model has promising result for coaxial rotor configuration (Ref.4-6). Recently, the focus of the dynamic inflow modeling has shifted to tandem rotor configurations (Ref.7, 8). The development of the dynamic inflow models for tandem rotor configuration still have some limitations due to the lack of knowledge of rotor-to-rotor interference, and rotor-wake interference. Experimental methods, and computational fluid dynamics methods are commonly used to understand the rotor performance and rotor airload variations, and measure or predict inflow velocity distributions at the rotor desk. The inflow distributions are subsequently used to improve the dynamic inflow models. Tandem rotor configurations have been studied experimentally and computationally for several decades (Ref.9-12). Sweet (Ref.10) observed that a tandem rotor with 76-percent-radius overlap required 14% more induced power at hovering condition, relative to an isolated rotor of equivalent disk area. Sweet also found that, above a shaft-to-shaft distance of 1.03 diameter, the performance of the tandem rotor was nearly the same as two isolated rotors. The objective of the present study is to apply computational fluid dynamics simulations of tandem rotors for the extraction of dynamic inflow models. The extended methodology is first validated by comparing the computed induced power against test data. Subsequently inflow distributions and wake structures are analyzed.

Extraction of Dynamic Inflow Models↗

Coaxial Nanowire Electrodes Enable Exceptional Fuel Cell Durability

Polymer-electrolyte-membrane fuel cells (PEMFCs) hold great promise for applications in clean energy conversion, but cost and durability continue to limit commercialization. This work presents a new class of catalyst/electrode architecture that does not rely on Pt particles or carbon supports, eliminating the primary degradation mechanisms in conventional electrodes, and thereby enabling transformative durability improvements. The coaxial nanowire electrode (CANE) architecture consists of an array of vertically aligned nanowires, each comprising an ionomer core encapsulated by a nanoscale Pt film. This unique design eliminates the triple-phase boundary and replaces it with two double-phase boundaries, increasing Pt utilization. It also eliminates the need for carbon support and ionomer binder, enabling improved durability and faster mass transport. Fuel cell membrane electrode assemblies based on CANEs demonstrate extraordinary durability in accelerated stress tests (ASTs), with only 2% and 5% loss in performance after 5000 support AST cycles and 30000 catalysts AST cycles, respectively. The high-power density and extremely high durability provided by CANEs can enable a paradigm shift from random electrodes based on unstable platinum nanoparticles dispersed on carbon to ordered electrodes based on durable Pt nanofilms, facilitating rapid deployment of fuel cells in transportation and other clean energy applications.

25 ENERGY STORAGE↗

Coaxial Direct Ink Writing of Cholesteric Liquid Crystal Elastomers in 3D Architectures

Abstract Cholesteric liquid crystal elastomers (CLCEs) hold great promise for mechanochromic applications in anti‐counterfeiting, smart textiles, and soft robotics, thanks to the structural color and elasticity. While CLCEs are printed via direct ink writing (DIW) to fabricate free‐standing films, complex 3D structures are not fabricated due to the opposing rheological properties necessary for cholesteric alignment and multilayer stacking. Here, 3D CLCE structures are realized by utilizing coaxial DIW to print a CLC ink within a silicone ink. By tailoring the ink compositions, and thus, the rheological properties, the cholesteric phase rapidly forms without an annealing step, while the silicone shell provides encapsulation and support to the CLCE core, allowing for layer‐by‐layer printing of self‐supported 3D structures. As a demonstration, free‐standing bistable thin‐shell domes are printed. Color changes due to compressive and tensile stresses can be witnessed from the top and bottom of the inverted domes, respectively. When the domes are arranged in an array and inverted, they can snap back to their base state by uniaxial stretching, thereby functioning as mechanical sensors with memory. The additive manufacturing platform enables the rapid fabrication of 3D mechanochromic sensors thereby expanding the realm of potential applications for CLCEs.

36 MATERIALS SCIENCE↗

Simons Observatory Microwave SQUID Multiplexing Readout: Cryogenic RF Amplifier and Coaxial Chain Design

The Simons Observatory (SO) is an upcoming polarization-sensitive cosmic microwave background experiment on the Cerro Toco Plateau (Chile) with large overlap with other optical and infrared surveys (e.g., DESI, LSST, HSC). To enable the readout of O(10,000) detectors in each of the four telescopes of SO, we will employ the microwave SQUID multiplexing technology. With a targeted multiplexing factor of O(1000), microwave SQUID multiplexing has never been deployed on the scale needed for SO. Here we present the design of the cryogenic coaxial cable and RF component chain that connects room temperature readout electronics to superconducting resonators that are coupled to transition edge sensor bolometers operating at sub-Kelvin temperatures. We describe design considerations including cryogenic RF component selection, system linearity, noise, and thermal power dissipation.

47 OTHER INSTRUMENTATION↗

Coaxial color channel focus evaluation to estimate standoff height in directed energy deposition additive manufacturing

Directed energy deposition (DED) is an additive manufacturing process that is being rapidly adopted by industry and is well suited for the fabrication of complex components in a variety of metal alloys. In laser cladding systems such as DED, powder is blown in a stream to a metal substrate coincident with a laser necessary to deposit molten metal with 3D spatial control. The focus of both the laser and the powder stream are crucial, and best deposition occurs at a predetermined standoff height between the build surface and the print head. Generally, no monitoring of this distance is implemented in commercial DED systems. Due to potential over or under building, the standoff height often changes over time but tends to self-correct. However, inexpensive and minimally intrusive methods to identify optimal standoff are required to provide real-time control to maintain the optimal distance. The present work explores the quantification of the focus of the three-color channels of a coaxial camera to determine the standoff height. An experiment was performed in which a 254 mm wall is built and the standoff height, initially 5.0 mm below the optimal position, was then intentionally increased every 25.4 mm of wall length by an amount of 1.0 mm to a final position 7.0 mm above optimal. Computer vision is demonstrated to monitor the amount of focus in each color band and estimate standoff distance. Finally, a response can be calculated in under 40 ms using simple hardware and can work in most laser-based DED systems.

36 MATERIALS SCIENCE↗

First experimental measurements with the Segmented Inverted-coaxial GerMAnium (SIGMA) detector

The SIGMA project aims to develop a p-type segmented inverted coaxial point contact germanium detector for gamma-ray tracking and imaging. Here the performance of the first prototype of this type of detector is reported. The measurements performed verified the size and shape of the crystal and determined the location of the complex active volumes of the detector segments. The latter determines the charge collection times that are related to the position of interaction. Good agreement is found between the results and the specified crystal design. The energy resolution of the point contact has been measured to be 0.84 keV and 2.21 keV at 122 keV and 1332 keV, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of a central barrier potential on asymmetry-induced transport in a coaxial Malmberg–Penning trap

Experiments are presented measuring the radial particle flux produced when a central barrier potential is applied to the central ring of a coaxial Malmberg-Penning trap at the same time as the voltages producing the main asymmetry potential $\phi_1(r)\cos{(kz)}\cos{(l\theta-\omega t)}$. When a negative DC voltage is applied to the entire central ring, the peak flux produced by the main asymmetry is reduced by a factor $e^{(V_{eff}/1.2)}$ where $V_{eff}$ is the effective applied potential in volts. This barrier potential also increases the frequency of this peak flux. When asymmetric $\pm$ voltages are applied to the two azimuthally-divided halves of the central ring, DC voltages increase the radial flux while AC voltages decrease it. It is shown that these asymmetric barrier voltages produce their own transport and that the resulting modification of the plasma may be a factor in changing the observed flux.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Niobium coaxial cavities with internal quality factors exceeding 1.4 × 10 9 for circuit quantum electrodynamics

Group-V materials such as niobium and tantalum have become popular choices for extending the performance of circuit quantum electrodynamics (cQED) platforms, allowing for quantum processors and memories with reduced error rates and more modes. The complex surface chemistry of niobium, however, makes identifying the main modes of decoherence difficult at millikelvin temperatures and single-photon powers. We use niobium coaxial quarter-wave cavities to study the impact of etch chemistry, prolonged atmospheric exposure, and the significance of cavity conditions prior to and during cooldown—in particular, niobium hydride evolution—on single-photon coherence. We demonstrate cavities with quality factors Q int ≳ 1.4 × 10 9 in the single-photon regime, a 15-fold improvement over aluminum cavities of the same geometry. We rigorously quantify the sensitivity of our fabrication process to various loss mechanisms and demonstrate a two- to fourfold reduction in the two-level system loss tangent and a three- to fivefold improvement in the residual resistance over traditional buffered chemical polishing etching techniques. Finally, we demonstrate transmon integration and coherent cavity control while maintaining a cavity coherence of 11.3 ms. The accessibility of our method, which can be easily replicated in academic laboratory settings, together with the demonstration of its performance, mark an advancement in three-dimensional cQED.

Oriani, Andrew E. [Chicago U., EFI; Chicago U.] (O↗

First Axionlike Particle Results from a Broadband Search for Wavelike Dark Matter in the 44 to 52 μ ⁢eV Range with a Coaxial Dish Antenna

We present the results from the first axionlike particle search conducted using a dish antenna. The experiment was conducted at room temperature and sensitive to axionlike particles in the 44–52 μ ⁢eV range (10.7–12.5 GHz). The novel dish antenna geometry was proposed by the BREAD Collaboration and previously used to conduct a dark photon search in the same mass range. To allow for axionlike particle sensitivity, the BREAD dish antenna was placed in a 3.9 T solenoid magnet at Argonne National Laboratory. In the presence of a magnetic field, axionlike dark matter converts to photons at the conductive surface of the reflector. The signal is focused onto a custom coaxial horn antenna and read out with a low-noise radio-frequency receiver. No evidence of axionlike dark matter was observed in this mass range and we place the most stringent laboratory constraints on the axion-photon coupling strength, 𝑔 𝑎⁢𝛾⁢𝛾 , in this mass range at 90% confidence.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Coaxial laser absorption and optical emission spectroscopy of high-pressure aluminum monoxide

This work advances laser absorption spectroscopy with measurements of aluminum monoxide (AlO) temperature and column density in extreme pressure ( P > 60 bar) and temperature ( T > 4000 K) environments. Measurements of the AlO A 2 Π i – X 2 Σ + transition are made using a microelectromechanical system, tunable vertical cavity surface emitting laser (MEMS-VCSEL). Simultaneous emission measurements of the AlO B 2 Σ + – X 2 Σ + transition are made along a line of sight that is coaxial with the laser absorption. Absorption temperature fits agree with emission spectra for a T = 3200 K, P = 9 bar case. In cases with T > 4000 K, P > 60 bar, absorption fits match the ambient temperature while emission fits over-estimate it, owing to high optical depths. These data juxtapose passive and active spectroscopic methods and demonstrate the versatility of AlO laser absorption in high-pressure and high-temperature environments where experimental data remain scarce, and engineering models will benefit from refined measurements.

Daniel, K. A.↗

Temperature, rf field, and frequency dependence performance evaluation of superconducting niobium half-wave coaxial cavity

Recent advancement in superconducting radio frequency cavity processing techniques, with diffusion of impurities within the RF penetration depth, resulted in high quality factor with increase in quality factor with increasing accelerating gradient. The increase in quality factor is the result of a decrease in the surface resistance as a result of nonmagnetic impurities doping and change in electronic density of states. The fundamental understanding of the dependence of surface resistance on frequency and surface preparation is still an active area of research. Here, we present the result of RF measurements of the TEM modes in a coaxial half-wave niobium cavity resonating at frequencies between 0.3 ? 1.3 GHz. The temperature dependence of the surface resistance was measured between 4.2 K and 1.6 K. The field dependence of the surface resistance was measured at 2.0 K. The baseline measurements were made after standard surface preparation by buffered chemical polishing.

Dhakal, P.↗