Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “clocks”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Molecular-Level Dysregulation of Insulin Pathways and Inflammatory Processes in Peripheral Blood Mononuclear Cells by Circadian Misalignment

Circadian misalignment due to night work has been associated with elevated risk for chronic diseases. Here, we investigated the effects of circadian misalignment using shotgun protein profiling of peripheral blood mononuclear cells taken from healthy humans during a constant routine protocol, which was conducted immediately after participants had been subjected to a 3-day simulated night shift schedule or a 3-day simulated day shift schedule. By comparing proteomic profiles between the simulated shift conditions, we identified proteins and pathways that are associated with the effects of circadian misalignment, and observed that insulin regulation pathways and inflammation-related proteins displayed markedly different temporal patterns after simulated night shift. Further, by integrating the proteomic profiles with previously assessed metabolomic profiles in a network-based approach, we found key associations between circadian dysregulation of protein-level pathways and metabolites of interest in the context of chronic metabolic diseases. Overall, our results suggest that circadian misalignment is associated with a tug of war between central clock mechanisms controlling insulin secretion and peripheral clock mechanisms regulating insulin sensitivity, which may lead to adverse long-term outcomes such as diabetes and obesity. Our study provides a molecular-level mechanism linking circadian misalignment and adverse long-term health consequences of night work.

59 BASIC BIOLOGICAL SCIENCES↗

Multi-site integrated optical addressing of trapped ions

Abstract One of the most effective ways to advance the performance of quantum computers and quantum sensors is to increase the number of qubits or quantum resources in the system. A major technical challenge that must be solved to realize this goal for trapped-ion systems is scaling the delivery of optical signals to many individual ions. In this paper we demonstrate an approach employing waveguides and multi-mode interferometer splitters to optically address multiple 171 Yb + ions in a surface trap by delivering all wavelengths required for full qubit control. Measurements of hyperfine spectra and Rabi flopping were performed on the E2 clock transition, using integrated waveguides for delivering the light needed for Doppler cooling, state preparation, coherent operations, and detection. We describe the use of splitters to address multiple ions using a single optical input per wavelength and use them to demonstrate simultaneous Rabi flopping on two different transitions occurring at distinct trap sites. This work represents an important step towards the realization of scalable integrated photonics for atomic clocks and trapped-ion quantum information systems.

74 ATOMIC AND MOLECULAR PHYSICS↗

High-fidelity entanglement and coherent multi-qubit mapping in an atom array

Neutral atoms in optical tweezer arrays possess broad applicability for quantum technologies, such as computing, analogue simulation and metrology. The atomic species ytterbium-171 is able to host multiple types of qubits, making it a strong candidate for bridging various applications of tweezer arrays. Realizing this potential requires high-fidelity generation and transfer of many-body entanglement between these distinct qubit degrees of freedom. Here, in this study, we demonstrate the creation and coherent mapping of entangled quantum states across multiple qubits in ytterbium-171 tweezer arrays. We map entangled states onto the optical clock qubit from the nuclear spin qubit or the Rydberg qubit. We coherently transfer Z 2 -ordered Greenberger–Horne–Zeilinger states of up to 20 atoms from the interacting Rydberg manifold to the metastable nuclear spin manifold. Furthermore, we find that clock-qubit-based spin detection, when applied to Rydberg and nuclear spin qubits, facilitates atom-loss-detectable qubit measurements and Rydberg decay detection. This enables delayed-erasure detection, yielding an error-detected two-qubit gate fidelity of 99.78(4)% in metastable qubits. These results establish a versatile architecture that advances multiple fields of quantum information science while also establishing bridges between them.

Senoo, Aruku [University of Colorado, Boulder, CO ↗

Continuous operation of a coherent 3,000-qubit system

Neutral atoms are a promising platform for quantum science, enabling advances in areas ranging from quantum simulations and computation to metrology, atomic clocks and quantum networking. Although atom losses typically limit these systems to a pulsed mode, continuous operation could substantially enhance cycle rates, remove bottlenecks in metrology and enable deep-circuit quantum evolution through quantum error correction. Here we demonstrate an experimental architecture for high-rate reloading and continuous operation of a large-scale atom-array system while realizing coherent storage and manipulation of quantum information. Our approach utilizes a series of two optical lattice conveyor belts to transport atom reservoirs into the science region, where atoms are repeatedly extracted into optical tweezers without affecting the coherence of qubits stored nearby. Using a reloading rate of 300,000 atoms in tweezers per second, we create over 30,000 initialized qubits per second, which we leverage to assemble and maintain an array of over 3,000 atoms for more than 2 hours. Furthermore, we demonstrate persistent refilling of the array with atomic qubits in either a spin-polarized or a coherent superposition state while preserving the quantum state of stored qubits. Our results pave the way for the realization of large-scale continuously operated atomic clocks, sensors and fault-tolerant quantum computers.

atomic and molecular physics↗

Laser-based conversion electron Mössbauer spectroscopy of 229 ThO 2

The exceptionally low-energy 229 Th nuclear isomeric state is expected to provide several new and powerful applications, including the construction of a robust and portable solid-state nuclear clock, perhaps contributing to a redefinition of the second, exploration of nuclear superradiance and tests of fundamental physics. Further, analogous to the capabilities of traditional Mössbauer spectroscopy, the sensitivity of the nucleus to its environment can be used to realize laser Mössbauer spectroscopy and, with it, new types of strain and temperature sensors and a new probe of the solid-state environment, all with excellent sensitivity. However, current models for examining the nuclear transition in a solid require the use of a high-bandgap, vacuum ultraviolet (VUV) transmissive host, severely limiting the applicability of these techniques. Here we report the first, to the authors’ knowledge, demonstration of laser-induced conversion electron Mössbauer spectroscopy (CEMS) of the 229 Th isomer in a thin ThO 2 sample whose bandgap (approximately 6 eV) is considerably smaller than the nuclear isomeric state energy (8.4 eV). Unlike fluorescence spectroscopy of the 229 Th isomeric transition, this technique is compatible with materials whose bandgap is less than the nuclear transition energy, opening a wider class of systems to study and the potential of a conversion-electron-based nuclear clock.

36 MATERIALS SCIENCE↗

A field programmable gate array-based timing and control system for the dynamic compression sector

A field programmable gate array (FPGA)-based timing and trigger control system has been developed for the Dynamic Compression Sector (DCS) user facility located at the Advanced Photon Source (APS) at Argonne National Laboratory. The DCS is a first-of-its-kind capability dedicated to dynamic compression science. All components of the DCS laser shock station—x-ray choppers, single-shot shutter, internal laser triggers, and shot diagnostics—must be synchronized with respect to the arrival of x rays in the hutch. An FPGA synchronized to the APS storage ring radio frequency clock (352 MHz) generates trigger signals for each stage of the laser and x-ray shutter system with low jitter. The developed FPGA-based control system was the first system used to control the laser and the shutter system since its commissioning, and it has been developing since then to improve the timing jitter. The system is composed of a Zynq FPGA, a debug card, line drivers, and a power supply. The delay and offsets of the trigger signals can be adjusted by using a user-friendly graphical user interface with high precision. Here, the details of the system architecture, timing requirements, firmware, and software implementation along with the performance evaluation are presented in this paper. The system offers low timing jitter (15.5 ps rms) with respect to the APS 352 MHz clock, suitable for the 100 ps (FWHM) x-ray bunch duration at the APS.

47 OTHER INSTRUMENTATION↗

A superconducting nanowire binary shift register

We present a design for a superconducting nanowire binary shift register, which stores digital states in the form of circulating supercurrents in high-kinetic-inductance loops. Adjacent superconducting loops are connected with nanocryotrons, three-terminal electrothermal switches, and fed with an alternating two-phase clock to synchronously transfer the digital state between the loops. A two-loop serial-input shift register was fabricated with thin-film NbN and a bit error rate of less than 10 –4 was achieved, when operated at a maximum clock frequency of 83 MHz and in an out-of-plane magnetic field of up to 6 mT. A shift register based on this technology offers an integrated solution for low-power readout of superconducting nanowire single photon detector arrays and is capable of interfacing directly with room-temperature electronics and operating unshielded in high magnetic field environments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Gravity of two photon decay and its quantum coherence

A linear analytical solution is derived for the gravitational shock wave produced by a particle of mass M that decays into a pair of null particles. The resulting space-time is shown to be unperturbed and isotropic, except for a discontinuous perturbation on a spherical null shell. Formulae are derived for the perturbation as a function of polar angle, as measured by an observer at the origin observing clocks on a sphere at distance R. The effect of the shock is interpreted physically as an instantaneous displacement in time and velocity when the shock passes the clocks. The time displacement is shown to be anisotropic, dominated by a quadrupole harmonic aligned with the particle-decay axis, with a magnitude δτ ~ GM/c 3 , independent of R. The velocity displacement is isotropic. The solution is used to derive the gravitational effect of a quantum state with a superposition of a large number of randomly oriented, statistically isotropic particle decays. This approach is shown to provide a well-controlled approximation to estimate the magnitude of gravitational fluctuations in systems composed of null point particles up to the Planck energy in a causal diamond of duration τ = 2R/c, as well as quantum-gravitational fluctuations of black holes and cosmological horizons. Coherent large-angle quantum distortions of macroscopic geometry from fluctuations up to the Planck scale are shown to grow linearly with the duration, with a variance $\langle$δτ 2 $\rangle$ ~ τtP much larger than that produced in models without causal quantum coherence.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of a gigabit transceiver for the ATLAS inner tracker pixel detector readout upgrade

We present a gigabit transceiver prototype Application Specific Integrated Circuit (ASIC), GBCR, for the ATLAS Inner Tracker (ITk) Pixel detector readout upgrade. GBCR is designed in a 65-nm CMOS technology and consists of four upstream receiver channels, a downstream transmitter channel, and an Inter-Integrated Circuit (I2C) slave. The upstream channels receive the data at 5.12 Gbps passing through 5-meter 34-American Wire Gauge (AWG) Twin-axial (Twinax) cables, equalize and retime them with a recovered clock, and then drive an optical transmitter. The downstream channel receives the data at 2.56 Gbps from an optical receiver and drives the cable as same as the upstream channels. The jitter of the upstream channel output is measured to be 35 ps (peak-peak) when the Clock-Data Recovery (CDR) module is turned on and the jitter of the downstream channel output after the cable is 138 ps (peak-peak). The power consumption of each upstream channel is 72 mW when the CDR module is turned on and the downstream channel consumes 27 mW. GBCR survives the total ionizing dose of 200 kGy.

47 OTHER INSTRUMENTATION↗

Design and performance of an in-vacuum, magnetic field mapping system for the Muon g-2 experiment

The Muon g - 2 experiment at Fermilab (E989) aims to measure the anomalous magnetic moment, a μ , of the muon with a precision of 140 parts-per-billion. This requires a precise measurement of both the anomalous spin precession frequency, ω α , of muons stored in a magnetic field of 1.45 T, and a precise measurement of that magnetic field in terms of the shielded proton Larmor frequency, ω' ρ . The measurement of ω' ρ with a total systematic uncertainty of 70 parts-perbillion involves a combination of various nuclear magnetic resonance (NMR) probes. There are 378 probes mounted in fixed locations that constantly monitor field drifts. A water-based, cylindrical calibration probe provides the calibration in terms of the shielded proton Larmor frequency. A crucial element for the multi-step measurement of ω' ρ is the regular mapping of the magnetic field over the muon storage region. The former experiment at Brookhaven National Laboratory (BNL) employed an in-vacuum field mapping system equipped with 17 NMR probes, which was developed by the University of Heidelberg. We have refurbished and upgraded this system with new probes and electronics. The upgrades include the addition of 16-bit, 1 MSPS digitization of the NMR signals, which replaced the hardware-implemented zero-crossing counting of the system at Brookhaven. The digitized signals offer new capabilities in the NMR frequency analysis and its related systematic uncertainties. To sustain the higher data rates, a new communication scheme with time-division multiplexing was implemented to separate the important NMR reference clock from the data communication in order to reach the specifications for the accuracy and stability of the reference clock. A new barcode reader provides more precise azimuthal position determination during the measurement and calibration. While the mechanical systems that move the field mapper inside the storage ring have been mostly refurbished from BNL, the motion control system was completely replaced with a custom-built electronics centered around a commercial Galil motion controller. Both the field mapping NMR system and its motion control were successfully commissioned at Fermilab and have been in reliable operation during the first three data taking periods of the experiment at Fermilab. Finally, this article will provide the details of the upgrades of the field mapper and its performance.

47 OTHER INSTRUMENTATION↗

A sub-picosecond digitally-controlled phase delay

The use of precision timing measurements will be a major tool at the HL-LHC, where it will be used to suppress pile-up and to search for long-lived particles. To control a reference clock with sub-picosecond accuracy, we have fabricated in the TSMC 65 nm process a digitally controlled phase shifter. It is composed of a chain of 66 cells, each with a digitally controlled planar wave guide with either a short or long delay. With this a reference clock’s phase can be controlled to a precision of 200 fs with dynamic range of 12 ps.

Instruments & Instrumentation↗

ETROC1: the first full chain precision timing prototype ASIC for CMS MTD endcap timing layer upgrade

We present the design and characterization of the first fullchain precision timing prototype ASIC, named ETL Readout Chipversion 1 (ETROC1) for the CMS MTD endcap timing layer (ETL)upgrade. The ETL utilizes Low Gain Avalanche Diode (LGAD) sensors todetect charged particles, with the goal to achieve a time resolutionof 40–50 ps per hit, and 30–40 ps per track with hits from twodetector layers. The ETROC1 is composed of a 5 × 5 pixelarray and peripheral circuits. The pixel array includes a4 × 4 active pixel array with an H-tree shaped networkdelivering clock and charge injection signals. Each active pixel iscomposed of various components, including a bump pad, a chargeinjection circuit, a pre-amplifier, a discriminator, adigital-to-analog converter, and a time-to-digital converter. Thesecomponents play essential roles as the front-end link in processingLGAD signals and measuring timing-related information. Theperipheral circuits provide clock signals and readoutfunctionalities. The size of the ETROC1 chip is7 mm× 9 mm. ETROC1 has been fabricated in a 65 nmCMOS process, and extensively tested under stimuli of chargeinjection, infrared laser, and proton beam. The time resolution ofbump-bonded ETROC1 + LGAD chipsets reaches 42–46 ps per hit in thebeam test.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Half-life of 67 Cu

The half-life of 67 Cu was determined through serial gamma-ray spectrometry measurements of the dominant gamma emission (E γ : 184.6 keV; branching ratio: 48.7%) produced following β- decay. Data were collected consecutively for 1000 s per measurement, with a total of 3063 measurements over the duration of 36 days. The incidence rate for the 184.6 keV gamma-ray was determined from the spectral peak area and duration of each measurement. This rate was then corrected to account for detector dead-time, radioactive decay during each acquisition and drift in the computer clock in comparison to NIST nuclear clock. Least-squares regression analysis was performed to determine the half-life of 67 Cu. The result was 61.761 ± 0.004 h, which is the highest precision measurement to date, and marks a 24-fold precision improvement over the current Nuclear Data Sheets value.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A universal and constant rate of gene content change traces pangenome flux to LUCA

Abstract Prokaryotic genomes constantly undergo gene flux via lateral gene transfer, generating a pangenome structure consisting of a conserved core genome surrounded by a more variable accessory genome shell. Over time, flux generates change in genome content. Here, we measure and compare the rate of genome flux for 5655 prokaryotic genomes as a function of amino acid sequence divergence in 36 universally distributed proteins of the informational core (IC). We find a clock of gene content change. The long-term average rate of gene content flux is remarkably constant across all higher prokaryotic taxa sampled, whereby the size of the accessory genome—the proportion of the genome harboring gene content difference for genome pairs—varies across taxa. The proportion of species-level accessory genes per genome, varies from 0% (Chlamydia) to 30%–33% (Alphaproteobacteria, Gammaproteobacteria, and Clostridia). A clock-like rate of gene content change across all prokaryotic taxa sampled suggest that pangenome structure is a general feature of prokaryotic genomes and that it has been in existence since the divergence of bacteria and archaea.

Microbiology↗

Floquet operator dynamics and orthogonal polynomials on the unit circle

Operator spreading under stroboscopic time evolution under a unitary is studied. An operator Krylov space is constructed and mapped to orthogonal polynomials on a unit circle (OPUC), as well as to the Krylov space of the edge operator of the Floquet transverse field Ising model with inhomogeneous couplings (ITFIM). The Verblunsky coefficients in the OPUC representation are related to the Krylov angles parametrizing the ITFIM. The relations between the OPUC and spectral functions are summarized and several applications are presented. These include derivation of analytic expressions for the OPUC under persistent m-periodic dynamics, and the numerical construction of the OPUC for autocorrelations of the homogeneous Floquet-Ising model as well as the Z 3 clock model. The numerically obtained Krylov angles of the Z 3 clock model with long-lived period tripled autocorrelations show a spatial periodicity of six, and this observation is used to develop an analytically solvable model for the ITFIM that mimics this behavior.

Floquet systems↗

YbH + formation in an ytterbium ion trap

The trapped 171 Yb + ion is a promising candidate for portable atomic clock applications. However, with buffer-gas cooled ytterbium ions, the ions can be pumped into a low-lying 2 F 7 / 2 state or form YbH + molecules. These dark states reduce the fluorescence signal from the ions and can degrade the clock stability. In this work, we study the dynamics of the populations of the 2 F 7 / 2 state and YbH + molecules under different operating conditions of our 171 Yb + ion system. Our study indicates that 2 F 7 / 2 -state ions can form YbH + molecules through interactions with hydrogen gas. As observed previously, dissociation of YbH + is observed at wavelengths around 369 nm. We also demonstrate YbH+ dissociation using 405 nm light. Moreover, we show that the population in the dark states can be limited by using a single repump laser at 935 nm. Our study provides insights into the molecular formation in a trapped ion system.

74 ATOMIC AND MOLECULAR PHYSICS↗

Classification of electronic nematicity in three-dimensional crystals and quasicrystals

Electronic nematic order has been reported in a rich landscape of materials, encompassing not only a range of intertwined correlated and topological phenomena but also different underlying lattice symmetries. Motivated by these findings, we investigate the behavior of electronic nematicity as the spherical symmetry of three-dimensional (3D) space is systematically lowered by the lattice environment. Here, we consider all 32 crystallographic point groups as well as four major classes of quasicrystalline point groups, given the recent observations of electronic phases of interest in quasicrystalline materials and artificial twisted quasicrystals. Valuable insights are gained by establishing a mapping between the five-component charge-quadrupolar nematic order parameter of the electronic fluid and the 3D tensorial order parameter of nematic liquid crystals. We find that a uniaxial nematic state is only generically realized in polyhedral point groups (icosahedral and cubic), with the nematic director pointing along different sets of rotational symmetry axes. Interestingly, icosahedral point groups are the only ones in which the five nematic order parameter components transform as the same irreducible representation, making them the closest analog of 3D isotropic nematics. In axial point groups, one of the nematic components is always condensed, whereas the other four components decompose into an in-plane and an out-of-plane nematic doublet, resulting in biaxial nematic ground states. Because these two nematic doublets behave as Z q clock order parameters, this allows us to identify the types of crystals and quasicrystals that can host interesting electronic nematic phenomena enabled by the critical properties of the q ≥ 4 clock model, such as emergent continuous nematic fluctuations in 3D, critical phases with quasi-long-range nematic order in two dimensions (2D), and Ashkin-Teller nematicity in 2D.

3-dimensional systems↗

Dipole-Dipole Frequency Shifts in Multilevel Atoms

Dipole-dipole interactions lead to frequency shifts that are expected to limit the performance of next-generation atomic clocks. In this work, we compute dipolar frequency shifts accounting for the intrinsic atomic multilevel structure in standard Ramsey spectroscopy. When interrogating the transitions featuring the smallest Clebsch-Gordan coefficients, we find that a simplified two-level treatment becomes inappropriate, even in the presence of large Zeeman shifts. Further, for these cases, we show a net suppression of dipolar frequency shifts and the emergence of dominant nonclassical effects for experimentally relevant parameters. Our findings are pertinent to current generations of optical lattice and optical tweezer clocks, opening a way to further increase their current accuracy, and thus their potential to probe fundamental and many-body physics.

74 ATOMIC AND MOLECULAR PHYSICS↗