Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “circulator pump”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Energy-efficient sorption-based gas clothes dryer systems

Standard electric resistance and fuel-driven dehydration technologies exhibit a maximum coefficient of performance of well below 1 mainly due to enthalpy losses associated with the air leaving the dehydration system. To improve energy efficiency, condensing dryer systems condense the moisture captured from a product in a closed-loop air circulation cycle. Existing condensing dehydration systems including heat pump dryers, however, need to significantly cool the air to achieve dehumidification. The added cooling and subsequent heating to return the air to a desired drying temperature consume substantial energy and thus reduce drying performance. Here, an innovative sorption-based gas dehydration system is proposed to overcome barriers deteriorating energy efficiency in existing gas, electric, or heat pump dryer systems. Decoupling latent and sensible loads, the system employs a liquid-desiccant solution to directly capture air humidity, thereby allowing circulation of the air in a closed loop to achieve high drying energy efficiency. In other words, the system captures waste latent heat from the moisture produced during the dehydration process and reuses it to improve energy efficiency. This study focuses on a comprehensive quasi-steady-state thermodynamic modeling of the proposed sorption-based dehydration concept employed for a gas clothes dryer application to predict transient response and overall drying performance (i.e., time and energy metrics). The analysis indicates the proposed sorption-based gas clothes dryer system can deliver a specific moisture extraction rate of 1.71 kg of water per kWh (i.e., a combined energy factor of 3.167 kg (6.98 lbm) of dry cloth per kWh) with a drying time of 44 min. This is a 112% energy improvement compared with state-of-the-art gas clothes dryers exhibiting a combined energy factor of 1.50 kg (3.3 lbm) of dry cloth per kWh. The technology pursued here can potentially be employed as a platform for many fuel-driven equipment to take advantage of available waste thermal energy in the environment instead of simply burning a fuel.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fine-particle filter prevents damage to vacuum pumps

A filter system for mechanical pumps is designed with a baffle assembly that rotates in a circulating oil bath which traps destructive particles. This prevents severe damage to the pump and is serviceable for long periods before it requires cleaning.

Harlamert, P., Jr.↗

Systems evaluation of thermal bus concepts

Thermal bus concepts, to provide a centralized thermal utility for large, multihundred kilowatt space platforms, were studied and the results are summarized. Concepts were generated, defined, and screened for inclusion in system level thermal bus trades. Parametric trade studies were conducted in order to define the operational envelope, performance, and physical characteristics of each. Two concepts were selected as offering the most promise for thermal bus development. All of four concepts involved two phase flow in order to meet the required isothermal nature of the thermal bus. Two of the concepts employ a mechanical means to circulate the working fluid, a liquid pump in one case and a vapor compressor in another. Another concept utilizes direct osmosis as the driving force of the thermal bus. The fourth concept was a high capacity monogroove heat pipe. After preliminary sizing and screening, three of these concepts were selected to carry into the trade studies. The monogroove heat pipe concept was deemed unsuitable for further consideration because of its heat transport limitations. One additional concept utilizing capillary forces to drive the working fluid was added. Parametric system level trade studies were performed. Sizing and weight calculations were performed for thermal bus sizes ranging from 5 to 350 kW and operating temperatures in the range of 4 to 120 C. System level considerations such as heat rejection and electrical power penalties and interface temperature losses were included in the weight calculations.

Stalmach, D. D.↗

Regenerative Hydride Heat Pump

Hydride heat pump features regenerative heating and single circulation loop. Counterflow heat exchangers accommodate different temperatures of FeTi and LaNi4.7Al0.3 subloops. Heating scheme increases efficiency.

Jones, Jack A.↗

Multistage Electrophoretic Separators

A multistage electrophoresis apparatus has been invented for use in the separation of cells, protein molecules, and other particles and solutes in concentrated aqueous solutions and suspensions. The design exploits free electrophoresis but overcomes the deficiencies of prior free-electrophoretic separators by incorporating a combination of published advances in mathematical modeling of convection, sedimentation, electro-osmotic flow, and the sedimentation and aggregation of droplets. In comparison with other electrophoretic separators, these apparatuses are easier to use and are better suited to separation in relatively large quantities characterized in the art as preparative (in contradistinction to smaller quantities characterized in the art as analytical). In a multistage electrophoretic separator according to the invention, an applied vertical steady electric field draws the electrically charged particles of interest from within a cuvette to within a collection cavity that has been moved into position of the cuvette. There are multiple collection cavities arranged in a circle; each is aligned with the cuvette for a prescribed short time. The multistage, short-migration-path character of the invention solves, possibly for the first time, the fluid-instability problems associated with free electrophoresis. The figure shows a prototype multistage electrophoretic separator that includes four sample stations and five collection stages per sample. At each sample station, an aqueous solution or suspension containing charged species to be separated is loaded into a cuvette, which is machined into a top plate. The apparatus includes a lower plate, into which 20 collection cavities have been milled. Each cavity is filled with an electrophoresis buffer solution. For the collection of an electrophoretic fraction, the lower plate is rotated to move a designated collection cavity into alignment with the opening of the cuvette. An electric field is then applied between a non-gassing electrode in the collection cavity and an electrolyte compartment, which is separated from the cuvette by a semipermeable membrane. The electrolyte is refreshed by circulation by use of a peristaltic pump. In subsequent steps, the lower plate is rotated to collect other electrophoretic fractions. Later, the collected fractions are removed from the collection cavities through ports that have threaded plugs. The base of the apparatus contains power supplies and a computer interface. The design includes provisions for monitoring and feedback control of cavity position, electric field, and temperature. The operation of the apparatus can easily be automated, as demonstrated by use of software that has already been written for this purpose.

Thomas, Nathan↗

Initial steady-state core simulation capability or thermal and pool-type molten salt reactors, coupling reactor physics, thermal-hydraulics, and evolving chemistry

This report presents the development and validation of an initial steady-state multiphysics capability for molten salt reactors (MSRs) under the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program in Fiscal Year 2025. The framework integrates neutronics, thermal-hydraulics, species transport, and thermochemistry to capture the coupled dynamics of liquid-fueled systems. Implementation and testing were performed on two representative designs: the Molten Salt Reactor Experiment (MSRE), a thermal-spectrum, channeled-flow reactor, and the Lotus Molten Salt Reactor (L-MSR), a fast-spectrum, pool-type reactor. The modeling suite employs Griffin for reactor physics and depletion, Pronghorn and SAM for thermal-hydraulics, Thermochimica for chemistry, and Saline for thermophysical properties, with benchmarking and validation carried out against historical MSRE data, experimental flow-loop measurements, and reference depletion calculations from Monte Carlo codes. The framework demonstrated the ability to reproduce key reactor behaviors including temperature feedback, reactivity losses, delayed neutron precursor transport, xenon poisoning, and redox potential evolution. The results confirm the feasibility and accuracy of the coupled models in predicting steady-state and selected transient MSR behaviors. This latter ones are used in this report as a proxy indicating that the steady-state models from which the transient starts are accurate. For MSRE, validation showed good agreement with pump start-up and natural circulation tests, while for the L-MSR, benchmarking confirmed hydraulic calibration and consistency of neutronics–thermal coupling. The tools also provided new insights into species transport, noble metal deposition, and salt solidification dynamics. On the Xenon transport front, the code is validated against the steady state Xenon poisoining measurement and showed good agreement with the experimental value. Identified areas for future work include advanced void transport modeling, three-dimensional simulations, improved alloy corrosion models, and tighter integration with high-fidelity Monte Carlo codes. These developments provide a foundation for high-fidelity MSR simulations that can support reactor design optimization, safety assessments, and long-term operational strategies.

42 - ENGINEERING↗

Reduced CO 2 uptake and growing nutrient sequestration from slowing overturning circulation

Current Earth system models (ESMs) project dramatic slowing (28–42% by 2100) of Atlantic Meridional Overturning Circulation and Southern Meridional Overturning Circulation (SMOC) across a range of climate scenarios, with a complete shutdown of SMOC possible by year 2300. Slowing meridional overturning circulation (MOC) differentially impacts the ocean biological and solubility carbon pumps, leaving the net impact on ocean carbon uptake uncertain. Here using a suite of ESMs, we show that slowing MOC reduces anthropogenic carbon uptake by the solubility pump but increases deep-ocean storage of carbon and nutrients by the biological pump. The net effect reduces ocean uptake of anthropogenic CO 2 . The deep-ocean nutrient sequestration will increasingly depress global-scale, marine net primary production over time. As a result, MOC slowdown represents a positive feedback that could extend or intensify peak-warmth climate conditions on multi-century timescales.

58 GEOSCIENCES↗

A simulation-based study on different control strategies for variable speed pump in distributed ground source heat pump systems

Most commercial ground source heat pump systems (GSHP) in the United States are in a distributed configuration. These systems circulate water or an anti-freeze solution through multiple heat pump units via a central pumping system, which usually uses variable speed pump(s). Variable speed pumps have potential to significantly reduce pumping energy use; however, the energy savings in reality could be far away from its potential due to improper pumping system design and controls. In this paper, a simplified hydronic pumping system was simulated with the dynamic Modelica models to evaluate three different pumping control strategies. This includes two conventional control strategies, which are to maintain a constant differential pressure across either the supply and return mains, or at the most hydraulically remote heat pump; and an innovative control strategy, which adjusts system flow rate based on the demand of each heat pump. The simulation results indicate that a significant overflow occurs at part load conditions when the variable speed pump is controlled to main a constant differential pressure across the supply and return mains of the piping system. On the other hand, an underflow occurs at part load conditions when the variable speed pump is controlled to maintain a constant differential pressure across the furthest heat pump. The flow-demand-based control can provide needed flow rate to each heat pump at any given time, and with less pumping energy use than the two conventional controls. Finally, a typical distributed GSHP system was studied to evaluate the energy saving potential of applying the flow-demand-based pumping control strategy. This case study shows that the annual pumping energy consumption can be reduced by 62% using the flow-demand-based control compared with that using the conventional pressure-based control to maintain a constant differential pressure a cross the supply and return mains.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demonstration of an All-Refractory Corrosion-Resistant Molten Salt Pumping and Storage Infrastructure Up to 950 degrees C

Concentrating solar power (CSP) with thermal energy storage (TES) has an estimated cost similar to solar photovoltaics (PV) with lithium-ion batteries (LIB), but CSP + TES has the potential for significantly reduced cost by operating above 700 degrees C. However, this requires a TES medium and containment infrastructure which are chemically compatible and do not degrade above 700 degrees C. MgCl2-KCl-NaCl (MKN) salt is a promising medium, but when MKN salt has small amounts of water and oxygen dissolved in it, it excessively corrodes conventional commercial alloys. Here, we consider refractory materials including graphite, carbon-carbon composite (C/C), and molybdenum because they maintain high mechanical strength at elevated temperatures and are expected to resist corrosion by MKN salt. While selection of refractory materials is often constrained by the need to remain chemically stable in air, this work uses an enclosure filled with inert gas to allow the use of materials like graphite and molybdenum. Notably, graphite components can seal against liquids unlike many brittle refractory materials. We demonstrate a centrifugal pump and mechanical seals made of refractory materials in a laboratory-scale circulation loop, which successfully operated continuously for more than 49 h at temperatures ranging from 750 degrees C to 950 degrees C with no mechanical failures or chemical degradation of the refractory materials. To the best of our knowledge, this is the highest temperature molten salt circulation loop that has been successfully developed, and this refractory infrastructure allows for operation at even much higher temperatures (<1600 degrees C) if a storage medium with a lower vapor pressure is used. The principles of this architecture are relevant to other applications with high temperature flowing metals and salts including Generation IV nuclear fission reactors for power production and molten salt electrolysis reactors for metallurgical processing.

14 SOLAR ENERGY↗

Upgrade of the mechanically pumped CO 2 two-phase cooling system for the alpha magnetic spectrometer on the international space station

This study describes the successful upgrade of a mechanically pumped CO 2 two-phase cooling system in space by designing a new pump module for the Alpha Magnetic Spectrometer-02 on the International Space Station. Key factors for mission success are emphasized, including achieving high coolant filling accuracy within 10% of the target and maintaining system stability within ±1 °C. The impact of adding radiators to improve cooling efficiency is examined, and it is found that operating multi-radiators out-of-phase does not significantly affect system reliability. The centrifugal pump design is shown to allow for better lubricant circulation, while the in-house designed controller incorporates protective measures to prevent cavitation, overheating, and over-current. Further, this research advances the understanding of circulation loop systems and their upgrades in space and demonstrates the potential for extending the lifetime of space-borne mechanically pumped two-phase cooling systems.

42 ENGINEERING↗

Simulating Fracture Sealing by Granular LCM Particles in Geothermal Drilling

Lost circulation occurs when the returned fluid is less than what is pumped into the well due to loss of fluid to pores or fractures. A lost-circulation event is a common occurrence in a geothermal well. Typical geothermal reservoirs are often under-pressured and have larger fracture apertures. A severe lost-circulation event is costly and may lead to stuck pipe, well instability, and well abandonment. One typical treatment is adding lost-circulation materials (LCMs) to seal fractures. Conventional LCMs fail to properly seal fractures because their mechanical limit is exceeded at elevated temperatures. In this paper, parametric studies in numerical simulations are conducted to better understand different thermal effects on the sealing mechanisms of LCMs. The computational fluid dynamics (CFDs) and the discrete element method (DEM) are coupled to accurately capture the true physics of sealing by granular materials. Due to computational limits, the traditional Eulerian–Eulerian approach treats solid particles as a group of continuum matter. With the advance of modern computational power, particle bridging is achievable with DEM to track individual particles by modeling their interactive forces between each other. Particle–fluid interactions can be modeled by coupling CFD algorithms. Fracture sealing capability is investigated by studying the effect of four individual properties including fluid viscosity, particle size, friction coefficient, and Young’s modulus. It is found that thermally degraded properties lead to inefficient fracture sealing.

15 GEOTHERMAL ENERGY↗

A model of the formation of high-salinity shelf water on polar continental shelves

This study presents a model of the flow and salinity fields forced by sea-surface salinity flux and wind stress curl and examines the processes that create High-Salinity Shelf Water (HSSW). To investigate the relative effects of wind stress and buoyancy forcing in HSSW production, the polynya freezing rate in the model is varied from 0.0 to 0.30 m/d, and the Ekman pumping derived from the wind stress curl is varied independently from 0.0 to 1.8 x 10 exp 6 m/s. The Ekman pumping was found to control the magnitude of the circulation, while the polynya freezing rate controlled the extent of salinization in the shelf water. The flux of HSSW increases linearly with increasing Ekman pumping above 0.3 x 10 exp -6 m/s. The modeled flux of HSSW and the flux of derived Botttom Water for the present estimates of the forcings (a peak freezing rate of 0.10 m/d and Ekman pumping of 0.2 x 10 exp -6 m/s) agree with the fluxes inferred from physical and chemical observations in the deep Weddel Sea by oceanographic field programs.

Grumbine, Robert W.↗

Creative absorber design and optimization for CO 2 capture with aqueous piperazine

The Texas Carbon Management Program is preparing a Front-End Engineering Design (FEED) of the PZASTM (Piperazine with the Advanced Stripper TM ) for CO 2 capture at a natural gas combined cycle power plant in West Texas. This paper develops the absorber design for the capture system and studies the operational strategies of the absorber in response to ambient temperature swing. The design uses 2 absorber trains, and each train integrates absorption and a water-wash section in one column. Each column has a cross-section area of 174 m 2 and consists of 3 sections of MellapakPlus® 252Y structured packing. Packing heights for each section are 3, 4.9, and 2.7 m from top to bottom. A pump-around intercooler applied at the bottom bed circulates solvent and eliminates the direct contact cooler. The baseline CO 2 removal rate is 90% and will vary between 78% and 90% with ambient temperature. The system uses air cooling to eliminate cooling water usage. The water balance in the system will be managed by operating the water wash at a high circulation rate (1300 kg/h) to condense water during the night and make up for water loss during the day. Finally, the proposed design reduces the capital cost of the absorber column by minimizing the packing height and eliminating the direct contact cooler (DCC), and improves the energy cost by lowering the pump-around intercooling temperature and increasing the pump-around rate.

03 NATURAL GAS↗

Gas Retention, Gas Release, and Fluidization of Spherical Resorcinol-Formaldehyde (sRF) Ion Exchange Resin

The Low-Activity Waste Pretreatment System (LAWPS) is being developed to provide treated supernatant liquid from the Hanford tank farms directly to the Low-Activity Waste (LAW) Vitrification Facility at the Hanford Tank Waste Treatment and Immobilization Plant. The design and development of the LAWPS is being conducted by Washington River Protection Solutions, LLC. A key process in LAWPS is the removal of radioactive Cs from LAW liquids using ion exchange (IX) columns filled with spherical resorcinol-formaldehyde (sRF) resin. When loaded with radioactive Cs, radiolysis of water in the LAW liquid will generate hydrogen gas. In normal operations, the generated hydrogen is expected to remain dissolved in the liquid and be continuously removed by liquid flow. One accident scenario being evaluated is the loss of liquid flow through the sRF resin bed after it has been loaded with radioactive Cs and hydrogen gas is being generated by radiolysis. For an accident scenario with a loss of flow, hydrogen gas can be retained within the IX column both in the sRF resin bed and below the bottom screen that supports the resin within the column, which creates a hydrogen flammability hazard. Because there is a potential for a large fraction of the retained hydrogen to be released over a short duration as a gas release event, there is a need to quantify the size and rate of potential gas release events. Due to the potential for a large, rapid gas release event, an evaluation of mitigation methods to eliminate the hydrogen hazard is also needed. One method being considered for mitigating the hydrogen hazard during a loss of flow accident is to have a secondary flow system, with two redundant pumps operating in series, that re-circulates liquid upwards through the bed and into a vented break tank where hydrogen gas is released from the liquid and removed by venting the headspace of the break tank. The mechanism for inducing release of gas from the sRF bed is to fluidize the bed, which should allow retained bubbles to rise and be carried to the break tank. Currently, neither the ability of fluidizing a settled sRF bed to release gas nor the quantity of hydrogen gas that can be retained and the corresponding potential for large, rapid gas release events has been tested and evaluated. Accordingly, the purpose of this study was to conduct experiments and develop models that evaluate the ability of a re-circulating flow system to fluidize an sRF resin bed as a method to release retained hydrogen gas and maintain hydrogen gas retention at low levels, thereby avoiding conditions where hydrogen gas poses a flammability hazard. The purpose of the study was also to determine if effective hydrogen gas release would occur using a single constant fluidization velocity, because this is the most simple safety system to implement, for the range of fluid and sRF resin conditions anticipated in the column (because a velocity that is effective for one fluid/resin pair can be ineffective for different resin/fluid pairs). Finally, the study also included quantifying the volume of gas that can be retained in an sRF bed and the behavior of spontaneous, rather than fluidization-induced, gas release events.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design of evaporator of spacelab refrigerator/freezer

An Evaporator has been designed for NASA-Johnson Space Center Life Sciences to conduct experiments in Spacelab mission SLS-1 using different samples such as blood, urine, human tissues etc. Two units will fly - one as a Refrigerator (4 C) and the other as a Freezer (-22 C). The evaporator tube is dip brazed on a grooved flat plate. Aluminum heat sink is dip brazed on the other side of the plate. Freon R5O2 is pumped through the tube and air is circulated over the finned surface to transfer heat. As freon 5O2 is considered toxic, the whole freon tube is covered with an evaporator cover to contain any freon leakage to avoid exposure to crew members. This containment is under vacuum and this pressure is monitored along with the freon pressure to determine freon leakage so that necessary steps can be taken to stop contamination of the spacelab air. An stress analysis has been done and it is found to have adequate safety margin to meet the requirements of NASA safety and reliability standards.

Hye, A.↗

Champagne Heat Pump

The term champagne heat pump denotes a developmental heat pump that exploits a cycle of absorption and desorption of carbon dioxide in an alcohol or other organic liquid. Whereas most heat pumps in common use in the United States are energized by mechanical compression, the champagne heat pump is energized by heating. The concept of heat pumps based on other absorption cycles energized by heat has been understood for years, but some of these heat pumps are outlawed in many areas because of the potential hazards posed by leakage of working fluids. For example, in the case of the water/ammonia cycle, there are potential hazards of toxicity and flammability. The organic-liquid/carbon dioxide absorption/desorption cycle of the champagne heat pump is similar to the water/ammonia cycle, but carbon dioxide is nontoxic and environmentally benign, and one can choose an alcohol or other organic liquid that is also relatively nontoxic and environmentally benign. Two candidate nonalcohol organic liquids are isobutyl acetate and amyl acetate. Although alcohols and many other organic liquids are flammable, they present little or no flammability hazard in the champagne heat pump because only the nonflammable carbon dioxide component of the refrigerant mixture is circulated to the evaporator and condenser heat exchangers, which are the only components of the heat pump in direct contact with air in habitable spaces.

Jones, Jack A.↗

Anomalies in the South American Monsoon Induced by Aerosols

We have investigated the direct effects of aerosols on the water cycle of the South American monsoon using the NASA finite-volume general circulation model (fvGCM). Global aerosol forcings are computed from radiative transfer functions derived from global distributions of five species of aerosols, i.e., dust, black carbon, organic carbon, sulphate and sea salt from the Goddard Chemistry Aerosol Radiation Transport (GOCART) model. Comparing fvGCM experiments without aerosol forcing, and with different combinations of aerosol forcing, we evaluate the impacts of aerosol direct heating on the onset, maintenance and evolution of the South American summer monsoon. We find that during the pre-monsoon season (September-October-November) Saharan dust contribute to heating of the atmosphere over the central and eastern equatorial Atlantic/Africa region through the elevated heat pump mechanism. The heating generates an anomalous Walker circulation with sinking motion, and low level northeasterlies over the Caribbean and northwestern South America. The low level flow is blocked by the Andes, and turn south and southeastward, increasing the low level jet (LLJ) along the eastern slope of the Andes. The increased LLJ transports more moisture from the Atlantic and the Amazon, enhancing the moisture convergence over subtropical land regions of South America. The moisture convergence was further accelerated by atmospheric heating by biomass burning over the Amazon. The net results of the dust and biomass heating are: a) an advance of the monsoon rainy season, b) an enhanced LLJ and c) a shifting the South America monsoon land precipitation equatorward, with increased rain over southern Brazil and reduced rain over the La Plata basin. ramifications of this elevated heating heat pump mechanism in aerosol monsoon water cycle on climate variability and change will be discussed. The ramifications of this "elevated heating heat pump" mechanism in aerosol monsoom water cycle on climate variability and change will be discussed.

Lau, K. M. William↗

Influence of molecular oxygen addition on gain and generation characteristics of a cryogenic slab RF-discharge-pumped overtone CO laser

The influence of molecular oxygen addition to an active medium of a cryogenic slab RF-discharge-pumped overtone CO laser operating without active medium circulation on the threshold generation conditions and spectral and energy characteristics of laser radiation is calculated. Results of the modelling well agree with experimental data obtained at the initial period of laser operation and substantially differ from data obtained after reaching a stationary operation regime. The model sufficiently well describes characteristics of a single-pulse electron-beam controlled CO laser operated on gas mixtures comprising oxygen. In this model, the generation pulse profiles of a cryogenic slab CO laser operated on the fundamental band transitions of the CO molecule under pulsed-periodic RF pumping well agree with experimental data. The agreement is also observed for the parts of the RF-discharge power spent on exciting vibrational and electronic states of molecules. Reasons for distinctions between some other calculated and experimental data are analysed. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗