Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cell analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Si-based materials for lithium-ion batteries VIII. 90% surface-modified Si/C-lithiated polyacrylic acid electrode

X-ray photoelectron spectroscopy was used to analyze a 90% Si/C-lithiated polyacrylic acid electrode fabricated at the Cell Analysis, Modeling, and Prototyping Facility (CAMP), Argonne National Laboratory. The spectra were obtained using incident monochromatic Al K α radiation at 1486.6 eV (0.834 01 nm). An initial survey spectrum together with O 1s, C 1s, and Si 2p are presented. A final survey spectrum was collected to ascertain the amount of beam-induced damage, which appears to be minimal. Finally, the spectra indicate the principal core level photoelectron and Auger electron signals with only minor lithium signal and show the expected silicon-carbon species related to the surface modification process in addition to oxidized carbon and silicon due to atmospheric exposure as well contributions related to the binder material.

25 ENERGY STORAGE↗

Si-based materials for lithium-ion batteries IX: 70% surface-modified Si/C/polyethylene glycol-carbon black/lithiated polyacrylic acid electrode

X-ray photoelectron spectroscopy was used to analyze a 70% Si/C-carbon black/polyethylene glycol/lithiated polyacrylic acid electrode fabricated at the Cell Analysis, Modeling, and Prototyping Facility (CAMP), Argonne National Laboratory. The spectra were obtained using incident monochromatic Al K α radiation at 1486.6 eV (0.834 01 nm). An initial survey spectrum together with O 1s, C 1s, and Si 2p are presented. A final survey scan was collected to ascertain the amount of beam-induced damage, which appears to be minimal. Finally, the spectra indicate the principal core level photoelectron and Auger electron signals with only minor copper and lithium signals and show the expected silicon-carbon species related to the surface modification process in addition to oxidized carbon and silicon due to atmospheric exposure as well as contributions related to the binder material.

25 ENERGY STORAGE↗

Si-based materials for lithium-ion batteries X: 70% surface-modified Si/C/polyvinylidine difluoride-carbon black/lithiated polyacrylic acid electrode

X-ray photoelectron spectroscopy was used to analyze a 70% Si/C/polyvinylidine difluoride/carbon black/lithiated polyacrylic acid electrode fabricated at the Cell Analysis, Modeling, and Prototyping Facility (CAMP), Argonne National Laboratory. The spectra were obtained using incident monochromatic Al Kα radiation at 1486.6 eV (0.834 01 nm). A survey spectrum together with O 1s, C 1s, and Si 2p are presented. The spectra indicate the principal core level photoelectron and Auger electron signals with only minor copper and lithium signals and show the expected silicon-carbon and silicon-fluorine species related to the surface modification process in addition to oxidized carbon and silicon due to atmospheric exposure.

Haasch, Richard T. (ORCID:0000000194792595)↗

Si-based materials for lithium-ion batteries XI. 70% surface-modified Si/C/perfluorooctene-carbon black/lithiated polyacrylic acid electrode

X-ray photoelectron spectroscopy was used to analyze a 70% Si/C/perfluorooctene-carbon black/lithiated polyacrylic acid electrode fabricated at the Cell Analysis, Modeling, and Prototyping (CAMP) Facility, Argonne National Laboratory. The spectra were obtained using incident monochromatic Al K α radiation at 1486.6 eV (0.83 401 nm). A survey spectrum together with O 1s, C 1s, and Si 2p are presented. The spectra indicate the principal core level photoelectron and Auger electron signals with only minor sodium, copper, calcium, and lithium signals and show the expected silicon-carbon, carbon-fluorine, and silicon-fluorine species related to the surface modification process in addition to oxidized carbon and silicon due to atmospheric exposure.

25 ENERGY STORAGE↗

Nonlatching positive feedback enables robust bimodality by decoupling expression noise from the mean

Fundamental to biological decision-making is the ability to generate bimodal expression patterns where two alternate expression states simultaneously exist. Here in this study, we use a combination of single-cell analysis and mathematical modeling to examine the sources of bimodality in the transcriptional program controlling HIV’s fate decision between active replication and viral latency. We find that the HIV Tat protein manipulates the intrinsic toggling of HIV’s promoter, the LTR, to generate bimodal ON-OFF expression, and that transcriptional positive feedback from Tat shifts and expands the regime of LTR bimodality. This result holds for both minimal synthetic viral circuits and full-length virus. Strikingly, computational analysis indicates that the Tat circuit’s non-cooperative ‘non-latching’ feedback architecture is optimized to slow the promoter’s toggling and generate bimodality by stochastic extinction of Tat. In contrast to the standard Poisson model, theory and experiment show that non-latching positive feedback substantially dampens the inverse noise-mean relationship to maintain stochastic bimodality despite increasing mean-expression levels. Given the rapid evolution of HIV, the presence of a circuit optimized to robustly generate bimodal expression appears consistent with the hypothesis that HIV’s decision between active replication and latency provides a viral fitness advantage. More broadly, the results suggest that positive-feedback circuits may have evolved not only for signal amplification but also for robustly generating bimodality by decoupling expression fluctuations (noise) from mean expression levels.

59 BASIC BIOLOGICAL SCIENCES↗

On the Nature of Surface Defects Found in 2/0 N-Doped 9-Cell Cavities

In this contribution, we present a systematic study on the microstructure of 1.3 GHz 9-cell TESLA type SRF cavity, processed with 2/0 Nitrogen-doping surface treatment, to explain the premature quench phenomena commonly observed in N-doping treated cavities. The microstructure characterization was carried out using Secondary electron images, advanced metallurgical techniques such as EBSD in parallel with chemical information obtained from spectroscopic techniques. The most remarkable difference is observed in the ends-cavities (1 and 9), which showed roughening of the surface, revealing a series of morphologies associated with Nb cubic phase. The cell-to-cell analysis also showed standard features such as pits with different geometry and distribution, located in grains and grain boundaries. The defects found in this system suggest that the standard electropolishing chemical etching was insufficient to eliminate history defects produced during the manufacture of the cavity, without discarding the role of the impurities, N and O, that could have induced the growth of these morphologies.

43 PARTICLE ACCELERATORS↗

Atomistic insight into the ferroelastic post-stishovite transition by high-pressure single-crystal X-ray diffraction

Abstract The post-stishovite transition is a classic pseudo-proper typed ferroelastic transition with a symmetry-breaking spontaneous strain. This transition has been studied using high-pressure spontaneous strains, optic modes, and elastic moduli (Cij) based on the Landau modeling, but its atomistic information and structural distortion remain poorly understood. Here we have conducted synchrotron single-crystal X-ray diffraction measurements on stishovite crystals up to 75.3 GPa in a diamond-anvil cell. Analysis of the data reveals atomic positions, bond lengths, bond angles, and variations of SiO6 octahedra across the transition at high pressure. Our results show that the O coordinates split at ~51.4 GPa, where the apical and equatorial Si-O bond lengths cross over, the SiO6 octahedral distortion vanishes, and the SiO6 octahedra start to rotate about the c axis. Moreover, distortion mode analysis shows that an in-plane stretching distortion (GM1+ mode) occurs in the stishovite structure at high pressure while a rotational distortion (GM2+ mode) becomes dominant in the post-stishovite structure. These results are used to correlate with elastic moduli and Landau parameters (symmetry-breaking strain e1–e2 and order parameter Q) to provide atomistic insight into the ferroelastic transition. When the bond lengths of two Si-O bonds are equal due to the contribution from the GM1+ stretching mode, C11 converges with C12, and the shear wave VS1[110] polarizing along [110] and propagating along [110] vanishes. Values of e1–e2 and Q are proportional to the SiO6 rotation angle from the occurrence of the GM1+ rotational mode in the post-stishovite structure. Our results on the pseudo-proper type transition are also compared with that for the proper type in albite and improper type in CaSiO3 perovskite. The symmetry-breaking strain, in all these types of transitions, arises as the primary effect from the structural angle (such as SiO6 rotation or lattice constant angle) and its relevant distortion mode in the low-symmetry ferroelastic phase.

Geochemistry & Geophysics↗

Biosafety Level 3 Recon Training

The Biosafety Level 3 Recon training is a 3D virtual tool developed for the Counter WMD Analysis Cell (CWAC) and the Asymmetric Warfare Group (AWG) by the Application Modeling and Development Team within the NEN-3 International Threat Reduction Group. The training simulates a situation where friendly forces have secured from hostile forces a suspected bioweapons development laboratory. The trainee is a squad member tasked to investigate the facility, locate laboratories within the facility, and identify hazards to entrants and the surrounding area. Before beginning the 3D simulation, the trainee must select the appropriate MOPP level for entering the facility. The items in the simulation, including inside and outside the bioweapon facility, are items that are commonly used by scientists in Biosafety Level (BSL) laboratories. Each item has clickable red tags that, when activated, give the trainee a brief description of the item and a controllable turn-around view. The descriptions also contain information about potential hazards the item can present. Trainees must find all tagged items in order to complete the simulation, but can also reference descriptions and turn-around view of the items in a glossary menu. Training is intended to familiarize individuals whom have little or no biology or chemistry background with technical equipment used in BSL laboratories. The revised edition of this simulation (Biosafety Level 3 Virtual Lab) changes the trainee into a investigator instead of a military combatant. Many doors now require a virtual badge swipe to open. Airlock doors may come in sets such that the open door must be closed before the next door in the set can be opened. A user interface was added so that the instructor can edit the information about the items (the brief descriptions mentioned above) using the simulation software instead of the previous method of manually entering the material in xml settings files. Facility labels, such as "No Parking" and "Men's room", were changed from Korean, into English. No other changes were made.

59 BASIC BIOLOGICAL SCIENCES↗

New Aqueous Binders for Lithium-ion Batteries

This final report summarizes the research effort of the CRADA between PPG Industries and Argonne National Laboratory (CRADA # C1400501 and Amendment 1 - ACK 85C11, Rev. 1), and completes the requirements of Task #5 in the CRADA. The results from Argonne represent a combined effort between the MERF and CAMP Facility (Materials Engineering Research Facility and the Cell Analysis, Modeling and Prototyping Facility). The key points of this report can be briefly summarized as: The multicomponent aqueous binder for NCM cathodes developed by PPG shows promising results when used on the CAMP Facility’s pilot-scale coater; NCM523 cathode electrodes exposed to water exhibit a voltage anomaly in the first two formation cycles that appears to have little effect on the material capacity, but needs to be explored further; the experimental LFP electrode produced by PPG does cycle electrochemically, but with reduced capacity and an uncharacteristic voltage profile; there is no obvious correlation between the pH and zeta-potential of materials that are commonly used in the lithium-ion battery; lithium ions are more readily dissolved out of NCM523 by water than the transition metals (by two orders of magnitude), and suggests that the plating bath may need to be spiked with a lithium salt; the approach of creating sub-micron size NCM523 particles via ball milling results in a cathode material with poor electrochemical performance.

25 ENERGY STORAGE↗

Chemical contributions to silicon anode calendar aging are dominant over mechanical contributions

Silicon (Si) anodes are a promising candidate for increasing the energy density of lithium (Li)-ion batteries for electric vehicles. However, they have recently been identified as having poor calendar life that is insufficient for commercial needs, in addition to the well-known issue of their poor cycle life resulting from large volume expansion. Here, a specially designed protocol with variable rest periods between intermittent cycling is used to evaluate the impact of the mechanical disruption of Si and solid electrolyte interphase (SEI) from cycling on calendar aging measurements. Si was found to undergo more mechanical degradation during calendar aging with intermittent cycling than graphite. However, Si anode capacity fade was still dominated by time, especially for rest periods greater than or equal to 1 month between cycling. Postmortem dQ/dV half-cell analysis indicated this was mainly due to Li inventory loss and an increase in electrode resistance. Isothermal microcalorimetry further demonstrated that Si passivation is more disrupted than graphite passivation with intermittent cycling and suggested that there may be a chemical buildup of a detrimental species in the electrolyte, leading to a large spike in heat after the Si and SEI are disrupted by cycling.

25 ENERGY STORAGE↗

1970 NASA/GSFC Battery Workshop

NASA/GSFC workshop on materials processing, chemical analysis, cell processing, and testing of batteries for aerospace applications

Source record↗

Effects of processing and dopant on radiation damage removal in silicon solar cells

Gallium and boron doped silicon solar cells, processed by ion-implantation followed by either laser or furnace anneal were irradiated by 1 MeV electrons and their post-irradiation recovery by thermal annealing determined. During the post-irradiation anneal, gallium-doped cells prepared by both processes recovered more rapidly and exhibited none of the severe reverse annealing observed for similarly processed 2 ohm-cm boron doped cells. Ion-implanted furnace annealed 0.1 ohm-cm boron doped cells exhibited the lowest post-irradiation annealing temperatures (200 C) after irradiation to 5 x 10 to the 13th e(-)/sq cm. The drastically lowered recovery temperature is attributed to the reduced oxygen and carbon content of the 0.1 ohm-cm cells. Analysis based on defect properties and annealing kinetics indicates that further reduction in annealing temperature should be attainable with further reduction in the silicon's carbon and/or divacancy content after irradiation.

Weinberg, I.↗

Effects of processing and dopant on radiation damage removal in silicon solar cells

Gallium and boron doped silicon solar cells, processed by ion implantation followed by either laser or furnace anneal were irradiated by 1 MeV electrons and their postirradiation recovery by thermal annealing was determined. During the postirradiation anneal, gallium doped cells prepared by both processes recovered more rapidly and exhibited none of the severe reverse annealing observed for similarly processed 2 ohm-cm boron doped cells. Ion implanted furnace annealed 0.1 ohm-cm boron doped cells exhibited the lowest post-irradiation annealing temperatures after irradiation. The drastically lowered recovery temperature is attributed to the reduced oxygen and carbon content of the 0.1 ohm-cm cells. Analysis based on defect properties and annealing kinetics indicates that further reduction in annealing temperature is attainable with further reduction in the silicon's carbon and/or divacancy content after irradiation.

Weinberg, I.↗

Mars aqueous chemistry experiment

Mars Aqueous Chemistry Experiment (MACE) is designed to conduct a variety of measurements on regolith samples, encompassing mineral phase analyses, chemical interactions with H2O, and physical properties determinations. From these data, much can be learned or inferred regarding the past weathering environment, the contemporaneous soil micro-environments, and the general chemical and physical state of the Martian regolith. By analyzing both soil and duricrust samples, the nature of the latter may become more apparent. Sites may be characterized for comparative purposes and criteria could be set for selection of high priority materials on future sample return missions. The second year of the MACE project has shown significant progress in two major areas. MACE Instrument concept definition is a baseline design that has been generated for the complete MACE instrument, including definition of analysis modes, mass estimates and thermal model. The design includes multiple reagent reservoirs, 10 discrete analysis cells, sample manipulation capability, and thermal control. The MACE Measurement subsystems development progress is reported regarding measurement capabilities for aqueous ion sensing, evolved gas sensing, solution conductivity measurement, reagent addition (titration) capabilities, and optical sensing of suspended particles.

Clark, Benton C.↗

Two-fluid simulations of galaxy formation

We investigate the formation of galaxies and larger structure with a simulation modeling two gravitationally coupled fluids representing dark matter and baryons. The baryon gas dynamics are calculated with a smoothed particle hydrodynamics (SPH) method, and the physics modeled includes thermal pressure, shock heating, and radiative cooling. We simulate a 16 Mpc periodic cube with 64(exp 3) particles in each fluid and 10% baryon mass fraction. We confirm, for the first time experimentally, disk formation as a natural consequence of hierarchical clustering in a large-scale cosmological environment. The majority of isolated galaxies exhibit centrifugally supported disks. A power-law relation between cold baryonic mass and maximum rotation velocity is found, M varies as nu(sub rot)(exp alpha) with alpha = 2.5 after correcting for differential numerical resolution. Both the spatial and velocity distributions of the simulated galaxies are biased with respect to the dark matter. A counts-in-cells analysis indicates that an unphysical degree of merging in the central cluster is likely responsible for the antibias signal in the correlation function. A robust, scale-dependent velocity bias is measured. The ratio of galaxy to dark matter pairwise velocity dispersions on a scale of 1 Mpc is 0.7. The amplitude is only mildly dependent on redshift or mass cutoff and scales with separation as r(exp 0.2). The degree to which these results depend on numerical parameters is discussed. Mass resolution plays a key role in controlling the resulting fraction of cold, dense baryons. The mass fraction associated with galaxies decreases by a factor of approximately greater than 3 when the mass per particle is increased by a factor 8. Photoionization and energy input from supernova will have to be included to determine more carefully the fraction of highly dissipated material and the characteristics of the stellar component of galaxies.

Evrard, August E.↗

Imaging Large Scale Structure in the X-ray Sky

We present the first results of a wide solid angle, moderately deep Chandra survey of the Lockman Hole North West Region. Our 9 ACIS-I fields cover an effective solid angle of 0.33 sq deg and reach a depth of 3 x 10(exp -16) erg/sq cm/s in the 0.4-2 keV band, and 3 x 10(exp -15) erg/sq cm/s in the 2-8 keV band. The best fit logN-logS for the entire field, the largest contiguous Chandra field yet observed, matches well onto that of the Chandra Deep Field North. This indicates that over 90% of the 2-8 keV X-ray background is resolved into point sources. We show that the full range of the 'cosmic variance' previously seen in different Chandra fields can be reproduced in a small region of the sky. The count-in-cells analysis shows that the 2-10 keV band sources have much larger angular correlation scale than that of the 0.4-2 keV band. We found the large difference is likely to be caused by a stronger spatial correlation in the hard band sources rather than the redshift effect.

Yang, Y.↗

Principles, Techniques, and Applications of Tissue Microfluidics

The principle of tissue microfluidics and its resultant techniques has been applied to cell analysis. Building microfluidics to suit a particular tissue sample would allow the rapid, reliable, inexpensive, highly parallelized, selective extraction of chosen regions of tissue for purposes of further biochemical analysis. Furthermore, the applicability of the techniques ranges beyond the described pathology application. For example, they would also allow the posing and successful answering of new sets of questions in many areas of fundamental research. The proposed integration of microfluidic techniques and tissue slice samples is called tissue microfluidics because it molds the microfluidic architectures in accordance with each particular structure of each specific tissue sample. Thus, microfluidics can be built around the tissues, following the tissue structure, or alternatively, the microfluidics can be adapted to the specific geometry of particular tissues. By contrast, the traditional approach is that microfluidic devices are structured in accordance with engineering considerations, while the biological components in applied devices are forced to comply with these engineering presets. The proposed principles represent a paradigm shift in microfluidic technology in three important ways: Microfluidic devices are to be directly integrated with, onto, or around tissue samples, in contrast to the conventional method of off-chip sample extraction followed by sample insertion in microfluidic devices. Architectural and operational principles of microfluidic devices are to be subordinated to suit specific tissue structure and needs, in contrast to the conventional method of building devices according to fluidic function alone and without regard to tissue structure. Sample acquisition from tissue is to be performed on-chip and is to be integrated with the diagnostic measurement within the same device, in contrast to the conventional method of off-chip sample prep and subsequent insertion into a diagnostic device. A more advanced form of tissue integration with microfluidics is tissue encapsulation, wherein the sample is completely encapsulated within a microfluidic device, to allow for full surface access. The immediate applications of these approaches lie with diagnostics of tissue slices and biopsy samples e.g. for cancer but the approaches would also be very useful in comparative genomics and other areas of fundamental research involving heterogeneous tissue samples.

Wade, Lawrence A.↗