Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “carbon corrosion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Finite Element Analysis and Machine Learning Guided Design of Carbon Fiber Organosheet-Based Battery Enclosures for Crashworthiness

Carbon fiber composite can be a potential candidate for replacing metal-based battery enclosures of current electric vehicles (E.V.s) owing to its better strength-to-weight ratio and corrosion resistance. However, the strength of carbon fiber-based structures depends on several parameters that should be carefully chosen. Here, in this work, we implemented high throughput finite element analysis (FEA) based thermoforming simulation to virtually manufacture the battery enclosure using different design and processing parameters. Subsequently, we performed virtual crash simulations to mimic a side pole crash to evaluate the crashworthiness of the battery enclosures. This high throughput crash simulation dataset was utilized to build predictive models to understand the crashworthiness of an unknown set. Our machine learning (ML) models showed excellent performance (R 2 > 0.97) in predicting the crashworthiness metrics, i.e., crush load efficiency, absorbed energy, intrusion, and maximum deceleration during a crash. We believe that this FEA-ML work framework will be helpful in down select process parameters for carbon fiber-based component design and can be transferrable to other manufacturing technologies.

36 MATERIALS SCIENCE↗

The corrosion behavior of borosilicate glass in the presence of cementitious waste forms

Borosilicate glasses are widely used for radioactive waste disposal due to their ability to incorporate a variety of contaminants and radionuclides while exhibiting high durability in various disposal scenarios. This research evaluated the dissolution of borosilicate glass using both single-pass-flow-through (ASTM C1662-18) and product consistency test (ASTM C1285-21) methods with different solutions, including a cementitious-contacted water (called grout-contacted, GC, from this point) and solutions with varying levels of dissolved cementitious species such as Si, Ca, Al. Here, the results indicated that the presence of Ca plays a crucial role in suppressing glass corrosion, as evidenced by the slower normalized dissolution rates, which were one order of magnitude lower for boron and two orders of magnitude lower for rhenium, observed in both Ca-amended and GC solutions compared to the pH 12 buffer solution. This effect is attributed to the formation of a dense, low-porosity, and strongly bonded calcium silicate hydrate (CSH) layer on the glass surface, which implies that a glass corrosion process is influenced by ion exchange involving alkali ions Na + , K + , Ca 2+ , and hydrogen-containing species. A small number of glass particles treated in the GC solution showed minor corrosion pits in the form of shallow craters with an average diameter of approximately 500 μm. This observation is correlated with a significant reduction, 2000 to 3000 times lower, in the cumulative volume of glass pores, indicating that smaller pore voids were “sealed” in the presence of Ca 2+ ions, likely attributed to the formation of CSH precipitation or other corrosion products such as calcium carbonate saturated from the grout solution. These findings suggest that the presence of dissolved Ca in the GC solution can slow down the dissolution of borosilicate glass, contrary to the expected trend of higher dissolution rates resulting from exposure to high alkaline and thus higher pH solutions.

36 MATERIALS SCIENCE↗

Hydrophobic, Thermal-shock Resistant Lightweight Cement Composites in Hybrid Thermal Energy-Storage Geothermal Well System

Under the DOE EERE Geothermal Technology Office (GTO)-funded project in FY 2019-2022, Brookhaven National Laboratory (BNL) aimed to develop hydrophobic thermal-shock resistant lightweight well cement composites suitable for temporarily storing a curtailed hot working fluid incurred from excess geothermal-, solar-, and wind-generated energies in underground reservoirs thermal energy storage sites. This storage energy systems are designed to provide energy during the periods between energy-harvesting and -requiring periods. One key factor to the success of this project was hydrophobicity of cement composites. The hydrophobic composites not only upgrade thermal insulating properties of water-saturated composites for minimizing heat loss in upper well surface regions, but also provide improved mechanical properties related to thermal-shock resistance and the protection of carbon steel (CS) casing against corrosion.

15 GEOTHERMAL ENERGY↗

Corrosion Protection of Launch Infrastructure and Hardware Through the Space Shuttle Program

Corrosion, the environmentally induced degradation of materials, has been a challenging and costly problem that has affected NASA's launch operations since the inception of the Space Program. Corrosion studies began at NASA's Kennedy Space Center (KSC) in 1966 during the Gemini/Apollo Programs with the evaluation of long-term protective coatings for the atmospheric protection of carbon steel. NASA's KSC Beachside Corrosion Test Site, which has been documented by the American Society of Materials (ASM) as one of the most corrosive, naturally occurring environments in the world, was established at that time. With the introduction of the Space Shuttle in 1981, the already highly corrosive natural conditions at the launch pad were rendered even more severe by the acidic exhaust from the solid rocket boosters. In the years that followed, numerous efforts at KSC identified materials, coatings, and maintenance procedures for launch hardware and equipment exposed to the highly corrosiye environment at the launch pads. Knowledge on materials degradation, obtained by facing the highly corrosive conditions of the Space Shuttle launch environment, as well as limitations imposed by the environmental impact of corrosion control, have led researchers at NASA's Corrosion Technology Laboratory to establish a new technology development capability in the area of corrosion prevention, detection, and mitigation at KSC that is included as one of the "highest priority" technologies identified by NASA's integrated technology roadmap. A historical perspective highlighting the challenges encountered in protecting launch infrastructure and hardware from corrosion during the life of the Space Shuttle program and the new technological advances that have resulted from facing the unique and highly corrosive conditions of the Space Shuttle launch environment will be presented.

Calle, L. M.↗

The Effect of Flow on CO2 Corrosion of Self-Healing Metallic Coatings

Internal corrosion is an issue that affects natural gas pipelines, a significant part of the United States’ energy infrastructure. Over time, this corrosion has worn away longstanding pipelines due to the original construction materials used for the lines and impurities in the gas and liquid streams flowing through them. The main impurities in natural gas are H2O, CO2, H2S, and O2. One of the leading causes of corrosion is the CO2 dissolved in water, giving rise to carbonic acid formation, which can further dissolve the steel pipe. The National Energy Technology Laboratory (NETL) has been studying different solutions to this problem. One potential answer is a self-healing sacrificial metallic coating applied by a novel cold spray technique. This study explored the impact of flow on corrosion with this coating and carbon steel when exposed to a saturated CO2 environment by simulating the pipeline flow profile in a small-scale lab setting. The samples were evaluated using multiple electrochemical techniques that found corrosion rates and were backed up with surface analysis to conclude the behavior of the corrosion mechanisms. The cold spray coating exhibited steel corrosion protection under flow conditions. This study has significantly advanced our understanding of CO2 corrosion, particularly in the context of natural gas pipelines and coating design.

carbon steel↗

Determining Drying Conditions to Mitigate Hanford Transfer Line Corrosion

Radioactive waste is stored in underground, carbon-steel double-shell tanks at the Department of Energy Hanford site.1,2,3 The underground transfer lines are used to transfer the waste between the tanks and other assets at the Hanford tank farm facilities. The transfer lines constructed before 1990 are pipe-in-pipe design with most of the lines having carbon steel carrier pipe and carbon steel encasements. The lines constructed after 1990 have a stainless-steel carrier with a carbon steel encasement. The carrier lines, which are in contact with the waste, provide a critical confinement function, while the encasements provide secondary containment to reduce the risk of a release and contamination to the environment. In 2022, a visual inspection of the annulus between the encasement and the carrier for one of the pre-1990 transfer lines revealed standing liquid in contact with the carrier pipe. Additionally, a significant build-up of corrosion products on the exterior of the carrier pipe and the interior of the encasement pipe was observed. To assess the extent of condition, borescope inspections were performed in the encasement space of additional transfer lines in the facility to provide a baseline. The inspection revealed that of the lines inspected, 29 had either moisture present or evidence that moisture had been present in the past (e.g., waterline corrosion where the pipe had been exposed to standing water). Additional inspections indicated several instances of pitting corrosion on the interior of the encasement and exterior the carrier transfer lines. An image of the carrier pipe with several pits is presented in Figure 1(a) and the profiled image of the transfer line section along with the pit depths are presented Figure 1(b). As seen in the figure, the deepest pit was 73 mils on the pipe section. These lines were designated as “do-not-use” until further compensatory actions are implemented to return the lines to service.

Shukla, Pavan K. [Savannah River National Laborato↗

Progress and opportunities in corrosion mitigation in heat transfer fluids for next-generation concentrating solar power

Concentrating solar power (CSP) systems have gained considerable eminence in converting solar thermal energy into electrical power in recent years. According to the U.S. Department of Energy's Gen3 roadmap, the CSP system should operate > 700 °C, as its efficiency depends directly on the operating temperature of the heat transfer fluids (HTFs). A significant challenge, however, is the corrosion of containment materials by the HTFs that is exacerbated at the higher temperatures. A comprehensive review of the high temperature stable HTFs, their properties, corrosion mechanisms on different alloys, and corrosion mitigation measures is of much importance for directing a concerted research and development in the field, which forms the motivation for this compendium. First, molten salt HTFs and their thermophysical properties, along with liquid metals, are introduced. Corrosion of structural materials in different HTFs including molten salts, liquid metals, and supercritical carbon-di-oxide at various temperatures and the corrosion mechanisms are comprehensively reviewed. In addition, several corrosion mitigation methods are discussed. Finally, future directions for HTFs and corrosion mitigation methods in molten salts are proposed. As a result, the holistic review presented here will serve as the foundation for further research addressing relevant challenges and enabling the promise of achieving cost-competitive CSP.

14 SOLAR ENERGY↗

Validating corrosion models: A comparison of governing equations

Experimental validation of Finite Element Method (FEM) models varying electrochemical governing equations, inclusion of chemical reactions, and time on the resultant damage profile for two galvanic couples is explored. Two anode materials (Magnesium AZ31 and Carbon Steel) in contact with a cathode (Stainless Steel 304 L) were modeled in/exposed to NaCl (1 and 0.1 M respectively for the anode materials) for up to one week. The physics approach, inclusion of chemical reactions, and the boundary conditions required to accurately represent the damage profile in FEM models depended on the galvanic couple materials and, ultimately, the corrosion rate. For high rates of corrosion (i.e., magnesium anode), the Nernst-Planck equation with Electroneutrality was sufficient to describe the damage, while, for low rates of corrosion (i.e., carbon steel anode), the Laplace equation was sufficient. In all cases, the most complete governing equation (Nernst-Planck-Poisson Equation) was not necessary to accurately describe the damage. Precipitation reactions in solution also played a critical role in the predicted damage profile, especially for high corrosion rate systems. Finally, for short time periods (< 6 h), the choice of governing equations does not significantly influence damage profile results. Overall, the choice of physics to reduce error in simulations relies on the boundary conditions, geometry, conductivity of the solution, electrochemical potential differences, and time of exposure. The above results are discussed with regard to accuracy and computational savings.

Carbon steel↗

Progress on Advancing the Robotic Air-slot Volumetric Inspection System (RAVIS) for Hanford Under-tank Inspection - 20519

The 27 in-service double-shell tank (DST) systems at Hanford provide interim storage for nearly 56 million gallons of nuclear and hazardous chemical legacy waste. The safe and reliable storage of the waste is critical to the site's extended cleanup mission. While in service, the leak integrity of the DSTs must be demonstrated to satisfy the Washington Administrative Code, inform decisions on tank management, and gauge fitness for continued service beyond originally intended design lives. The carbon steel plates and welds that comprise DST primary tank sidewalls and lower knuckles are routinely 'sampled' for volumetric non-destructive testing using ultrasonic inspection technology to determine whether corrosion pitting, cracking, or general corrosion are occurring that could compromise tank leak integrity. However, the carbon steel plates and welds that comprise the bottoms of primary tanks have not been thoroughly inspected since the DSTs were constructed (i.e., since 1968-1986) due to limited physical access to the exterior tank bottoms. The Robotic Air-slot Volumetric Inspection System, or 'RAVIS,' is being engineered to overcome the challenge of tank bottom in-service inspection. The system will be deployed under primary tanks within the small cooling channels/air-slots in the refractory pads upon which the tanks rest and will use ultrasonic guided wave inspection technology to volumetrically inspect physically inaccessible regions that make up ∼90% of a tank bottom, as well as regions that are physically accessible from the air-slots but comprise only ∼10% of a tank bottom. This paper describes the air-slot sensor and robotic deployment system and focuses on the testing approach and methods that are being applied to support (1) design feedback and performance acceptance (requirement verification) and (2) performance repeatability/reliability assessments (qualification) to ensure the RAVIS is prepared for successful inservice inspections of primary tank bottoms. Test progress made against the test plan, the results of 2019 testing, and the future outlook are included. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Iron surface corrosion in supercritical CO2 at atomic scale investigated by molecular dynamics simulations

Understanding the corrosion behavior of steels in supercritical carbon dioxide (S-CO2) is essential for ensuring the safe application of S-CO2 as a heat-transfer fluid in high-temperature energy systems, including advanced nuclear reactors. In this work, molecular dynamics (MD) simulations using ReaxFF potential are performed to explore the atomic-scale corrosion mechanisms of body-centered cubic iron (BCC-Fe) in S-CO2. The results show that CO2 molecules in S-CO2 decompose at the Fe surface, generating free C and O atoms that form Fe-C and Fe-O bonds and subsequently produce oxides and carbides. Concurrently, Fe atoms dissolve from the surface and diffuse into the S-CO2 region, resulting in interdiffusion of Fe, C and O atoms at the interface. The corrosion-layer thickness calculations show that high pressure and temperature induced by S-CO2 have stronger effects than surface orientation on the corrosion process. In addition, surface Fe atoms undergo substantial displacement under S-CO2 exposure, further accelerating corrosion. When a radiation-induced void is introduced near the Fe surface, the corrosion is enhanced. The void-matrix interface expands the reaction surface area and simultaneously induces corrosion reactions inside the bulk, resulting in a deeper penetration of C and O and thicker corrosion layers. All these results indicate that high-temperature, high-pressure and radiation-induced voids can seriously affect the corrosion of Fe in S-CO2, and must be considered to better use S-CO2 in nuclear facilities.

Li, Wenhua↗

Fe-Coated Optical Fiber for Distributed Corrosion Monitoring in Soil and Aqueous Environment

Natural gas pipeline corrosion represents a substantial cost and safety concern during normal operations. The effective and real-time monitoring of corrosion is important to detect and mitigate pipeline risks before corrosion-related catastrophic events happen. Here, we describe the use of iron (Fe) coated optical fiber sensors (OFS) for distributed corrosion monitoring where Fe acts as a corrosion proxy. By using an optical backscattering reflectometer (OBR), corrosion was monitored based on the increase in the backscattered intensity amplitude of the light being passed as Fe underwent corrosion. The Fe-coated OFSs were prepared with a film thickness between 25–225 nanometers (nm) by an electroless plating approach and corroded by a carbon dioxide (CO2)-saturated acidic electrolyte. The corrosion rate (CR) was approximately 2.5 millimeters (mm)/year for Fe with a film thickness of 30 nm and increased with film thickness. Backscattering-based CRs were supported by visible light transmission measurements, which have been previously demonstrated. Additionally, a correlation between the intermittent transmission and residual Fe film thickness during the corrosion of Fe was established. The corrosion sensor was also tested in soil at > 1 foot depth. Fe-coated OFS was loaded into a Draka cable, which provides mechanical support during fiber deployment and installation into either acidified soil, top-soil, or sandy soil (50/50).

corrosion↗

Fe-Coated Optical Fiber for Distributed Corrosion Monitoring in Soil and Aqueous Environments

Natural gas pipeline corrosion represents a substantial cost and safety concern during normal operations. The effective and real-time monitoring of corrosion is important to detect and mitigate pipeline risks before corrosion-related catastrophic events happen. Here, we describe the use of iron (Fe) coated optical fiber sensors (OFS) for distributed corrosion monitoring where Fe acts as a corrosion proxy. By using an optical backscattering reflectometer (OBR), corrosion was monitored based on the increase in the backscattered intensity amplitude of the light being passed as Fe underwent corrosion. The Fe-coated OFSs were prepared with a film thickness between 25–225 nanometers (nm) by an electroless plating approach and corroded by a carbon dioxide (CO2)-saturated acidic electrolyte. The corrosion rate (CR) was approximately 2.5 millimeters (mm)/year for Fe with a film thickness of 30 nm and increased with film thickness. Backscattering-based CRs were supported by visible light transmission measurements, which have been previously demonstrated. Additionally, a correlation between the intermittent transmission and residual Fe film thickness during the corrosion of Fe was established. The corrosion was measurable out to > 100 meters (m), which is a significant improvement over our previous work, which showed corrosion sensing at < 10 m. The corrosion sensor was also tested in soil at > 1 foot depth.

corrosion↗

Fe-Coated Optical Fiber for Distributed Corrosion Monitoring in Soil and Aqueous Environments

Natural gas pipeline corrosion represents a substantial cost and safety concern during normal operations. The effective and real-time monitoring of corrosion is important to detect and mitigate pipeline risks before corrosion-related catastrophic events happen. Here, we describe the use of iron (Fe) coated optical fiber sensors (OFS) for distributed corrosion monitoring where Fe acts as a corrosion proxy. By using an optical backscattering reflectometer (OBR), corrosion was monitored based on the increase in the backscattered intensity amplitude of the light being passed as Fe underwent corrosion. The Fe-coated OFSs were prepared with a film thickness between 25–225 nanometers (nm) by an electroless plating approach and corroded by a carbon dioxide (CO2)-saturated acidic electrolyte. The corrosion rate (CR) was approximately 2.5 millimeters (mm)/year for Fe with a film thickness of 30 nm and increased with film thickness. Backscattering-based CRs were supported by visible light transmission measurements, which have been previously demonstrated. Additionally, a correlation between the intermittent transmission and residual Fe film thickness during the corrosion of Fe was established. The corrosion was measurable out to > 100 meters (m), which is a significant improvement over our previous work, which showed corrosion sensing at < 10 m. The corrosion sensor was also tested in soil at > 1 foot depth.

aqueous environment↗

The role of biomineralization in microbiologically influenced corrosion

Synthetic iron oxides (goethite, alpha-FeO.OH; hematite, Fe2O3; and ferrihydrite, Fe(OH)3) were used as model compounds to simulate the mineralogy of surface films on carbon steel. Dissolution of these oxides exposed to pure cultures of the metal-reducing bacterium, Shewanella putrefaciens, was followed by direct atomic absorption spectroscopy measurement of ferrous iron coupled with microscopic analyses using confocal laser scanning and environmental scanning electron microscopies. During an 8-day exposure the organism colonized mineral surfaces and reduced solid ferric oxides to soluble ferrous ions. Elemental composition, as monitored by energy dispersive x-ray spectroscopy, indicated mineral replacement reactions with both ferrihydrite and goethite as iron reduction occurred. When carbon steel electrodes were exposed to S. putrefaciens, microbiologically influenced corrosion was demonstrated electrochemically and microscopically.

Non-programmatic↗

Subcritical and supercritical water oxidation of CELSS model wastes

A mixture of ammonium hydroxide with acetic acid and a slurry of human feces, urine, and wipes were used as CELSS model wastes to be wet-oxidized at temperatures from 250 to 500 C, i.e. below and above the critical point of water (374 C and 218 kg/sq cm or 21.4 MPa). The effects of oxidation temperature ( 250-500 C) and residence time (0-120 mn) on carbon and nitrogen and on metal corrosion from the reactor material were studied. Almost all of the organic matter in the model wastes was oxidized in the temperature range from 400 to 500 C, above the critical conditions for water. In contrast, only a small portion of the organic matter was oxidized at subcritical conditions. A substantial amount of nitrogen remained in solution in the form of ammonia at temperatures ranging from 350 to 450 C suggesting that, around 400 C, organic carbon is completely oxidized and most of the nitrogen is retained in solution. The Hastelloy C-276 alloy reactor corroded during subcritical and supercritical water oxidation.

Takahashi, Y.↗

Inexpensive and Sustainable Anti-Corrosion Coating for Power Generation Applications

The goal of the project was to achieve lab-scale demonstration of a corrosion prevention technology, which will facilitate the capture of CO 2 from coal and natural gas fired power generation by reducing the cost of construction materials and maintenance. The project built on technology previously developed by LumiShield to address more broad-based corrosion issues and the results shown will be applicable to a wide range of markets requiring cost effective corrosion resistant coatings. That technology developed is a base layer to improve the performance and reduce the cost of organic anti-corrosion coatings. The impact of those changes on overall plant economics were demonstrated with the help of engineers at AECOM through an initial cost-benefit-analysis at the end of BP1 which will be updated at the end of BP2.

01 COAL, LIGNITE, AND PEAT↗

Effect of High Temperature CO 2 on Haynes 230 Alloy (Updated Jan 2021)

The supercritical carbon dioxide (sCO 2 ) Brayton cycle is a promising candidate for future nuclear reactors due to its ability to improve power cycle energy conversion efficiency. The sCO 2 Brayton cycle can operate with an efficiency of 45-50% at operating temperatures of 550-700 C. One of the greatest hurdles currently faced by sCO 2 Brayton cycles is the corrosivity of sCO 2 and the lack of long-term alloy corrosion and mechanical performance data, as these will be key to enhancing the longevity of the system, and thus the levelized cost of electricity. Past studies have shown that sCO 2 corrosion occurs through the formation of metal carbonates, oxide layers, and carburization, and alloys with Cr, Mo and Ni generally exhibit less corrosion. While stainless steels may offer sufficient corrosion resistance at the lower range of temperatures seen by the sCO 2 Brayton cycles, more expensive nickel-based alloys are typically needed for the higher temperature regions. This study investigates the effects of corrosion on the Haynes 230 alloy, with a preliminary view on changes in the mechanical properties. High temperature CO 2 is used for this study as the corrosion products are similar to that of supercritical CO 2 , allowing for an estimation of the susceptibility towards corrosion without the need for high pressure experimentation.

36 MATERIALS SCIENCE↗

Role of microstructure on CO corrosion of SiC layer in UO₂-TRISO fuel

The Advanced Gas Reactor Fuel Qualification and Development (AGR) program has focused on qualification of UCO kernel tristructural-isotropic (TRISO) particle fuel relative to UO₂ kernel TRISO particle fuel. However, a UO₂ kernel variant was included in the second AGR irradiation experiment (AGR-2) for comparison and to connect to historic fuel irradiation data. The development of a multiscale, post-irradiation examination (PIE) analysis approach through the AGR Program has allowed for a comprehensive understanding of individual particle failure. This approach has been applied to gain an understanding of SiC layer failure in UO₂ kernel TRISO fuel from AGR-2 after safety testing at 1600–1700 °C. Particle failure by intergranular CO corrosion, facilitated by a compromised inner pyrolytic carbon layer, has been confirmed through the combined application of modern x-ray computed tomography and electron microscopy techniques. In addition, a relationship between grain boundary character and CO corrosion has been identified. This finding provides an opportunity to develop mitigating strategies to improve the resilience of the SiC layer to CO corrosion in UO₂ TRISO fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗