Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “capillary flows”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Experimental characterization of discharge plasma dynamics in a square capillary for prospective applications in laser wakefield acceleration

Research on plasma generated by electrical discharge in gas-filled capillaries plays an important role in advancing laser wakefield accelerators. We present a comprehensive study of the temporal and spatial distribution of plasma density within a short, 1 cm long, square-shaped capillary filled with hydrogen gas. Two transverse capillary sizes, 500 μm and 300 μm, were investigated achieving peak plasma densities of 0.9 × 10 18 cm −3 and 2.5 × 10 18 cm −3 , respectively, at the capillary center. In addition, we explore how these distributions depend on discharge parameters, specifically discharge current and gas flow through the capillary. Plasma density was determined by analyzing the Stark broadening of the hydrogen Balmer-alpha line. The results obtained were compared with the theoretical models and simulations. The comparison between the model predictions and the experimental data at the transient ionization stage of the discharge reveals a discrepancy of a factor of ∼1.3–2.1, depending on the capillary size, which is thoroughly discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gas-flow restrictor

Gas flow restrictor is described, consisting of predetermined length and size of capillary tubing to control flow rate of carrier gas into gas chromatograph of flow rate of sample gas into mass spectrometer inlet system. Length and inner diameter of capillary tubing was estimated with mathematical expressions for viscous flow.

Bastien, G. J.↗

Preliminary investigation of elongational flow of dilute polymer solutions

A tubeless siphon apparatus has been set up to measure extensional flow. In this apparatus, the liquid is continuously drawn into a capillary and, after steady flow has been established, the tube is raised above the liquid surface. With viscoelastic liquids, the flow continues and a column can be lifted from the reservoir. At the capillary entrance, an oscillating bead of excess liquid collects which interferes with both the flow and the measurements. This can be minimized by careful control of the liquid-column height. For homogeneous solutions, the column is symmetrical and tapers steadily from the liquid surface to the capillary entrance, with no bulging. Preliminary results show tensile viscosities 1000 times that of the Trouton coefficient and having a very strong dependence on deformation rate. A concentration-stretch rate-reduced variable scheme is proposed.

Peng, S. T. J.↗

Dynamics of Liquids in Edges and Corners (DYLCO): IML-2 Experiment for the BDPU

Knowledge of the behavior of fluids possessing free surfaces is important to many fluid systems, particularly in space, where the normally subtle effects of surface wettability play a more dramatic and often surprising role. DYLCO for the IML-2 mission was proposed as a simple experiment to probe the particular behavior of capillary surfaces in containers of irregular cross section. Temperature control was utilized to vary the fluid-solid contact angle, a questionable thermodynamic parameter of the system, small changes in which can dramatically influence the configuration, stability, and flow of a capillary surface. Container shapes, test fluid, and temperature ranges were selected for observing both local changes in interface curvature as well as a global change in fluid orientation due to a critical wetting phenomenon. The experiment hardware performed beyond what was expected and fluid interfaces could be readily digitized post flight to show the dependence of the interface curvature on temperature. For each of the containers tested surfaces were observed which did not satisfy the classic equations for the prediction of interface shape with constant contact angle boundary condition. This is explained by the presence of contact angle hysteresis arising from expansion and contraction of the liquid during the heating and cooling steps of the test procedure. More importantly, surfaces exceeding the critical surface curvature required for critical wetting were measured, yet no wetting was observed. These findings are indeed curious and pose key questions concerning the role of hysteresis for this critical wetting phenomena. The stability of such surfaces was determined numerically and it is shown that stability is enhance (reduced) when a surface is in its 'advancing' ('receding') state, The analysis shows complete instability as the critical wetting condition is reached. The case of ideal dynamic wetting is addressed analytically in detail with results of significant flow characteristics presented in closed form. The solutions indicate a square root of T dependence of the capillary 'rise' rate which is corroborated by drop tower tests. The analysis clearly shows that infinite time is necessary for surfaces to reorient at the critical wetting transition.

Langbein, D.↗

Flow in a differentially rotated cylindrical drop at low Reynolds number

A liquid drop held captive between parallel disks that are differentially rotated is a model for the swirling flows induced by crystal rotation in the floating-zone process for growing semiconductor materials. An asymptotic analysis for a cylindrical drop is presented that elucidates the structure of the axisymmetric cellular motions caused by disk rotation at low Reynolds number. Variations of meniscus shape induced by these flows are described in the limit of small capillary number. Most cellular flow fields break the bifurcation point that corresponds to the Plateau-Rayleigh limit for the length of a static drop into two disjoint shape families and lower the maximum stable drop length. This effect is studied by a singular bifurcation analysis.

Harriott, G. M.↗

Measurements of capillary system degradation

The effects of vibration, flow transients, and warm gas pressurization on capillary acquisition system performance were evaluated. The degradation observed under wide band random and high frequency sinusoidal vibration was of a substantially different nature from that obtained under low frequency sinusoidal vibration. With the former, ingestion of small gas bubbles into the liquid region was correlated by a hydrostatic model, while the capillary stability was destroyed and liquid was lost from the liquid region with the latter. No degradation was observed as a result of flow transients in a flight-type multichannel screen device, but it was observed in a transparent laboratory device. Liquid hydrogen outflow tests were conducted with a multilayer dual-screen-liner system with both helium and hydrogen pressurant gases. The tendency towards dryout of the device with hydrogen pressurant was found to increase with increasing pressurant temperature and length of prepressurization period. Dryout did not occur with helium pressurant.

Warren, R. P.↗

Polyimide processing additives

A method has been found for enhancing the melt flow of thermoplastic polyimides during processing. A high molecular weight 422 copoly(amic acid) or copolyimide was fused with approximately 0.05 to 5 pct by weight of a low molecular weight amic acid or imide additive, and this melt was studied by capillary rheometry. Excellent flow and improved composite properties on graphite resulted from the addition of a PMDA-aniline additive to LARC-TPI. Solution viscosity studies imply that amic acid additives temporarily lower molecular weight and, hence, enlarge the processing window. Thus, compositions containing the additive have a lower melt viscosity for a longer time than those unmodified.

Pratt, J. R.↗

Capillary and acceleration wave breakup of liquid jets in axial-flow airstreams

Empirical correlations of reciprocal mean drop diameter with airstream momentum were derived from capillary and acceleration wave breakup of liquid jets atomized by cross stream injection into axial flow airstreams. A scanning radiometer was used to obtain data over an airstream momentum range of 3.7 to 25.7 g/sq cm sec. Transition from capillary to acceleration wave breakup was obtained at a critical Weber-Reynolds number of 1,000,000.

Ingebo, R. D.↗

Correlation of macro and micro cardiovascular function during weightlessness and simulated weightlessness

The investigation of cardiovascular function necessarily involves a consideration of the exchange of substances at the capillary. If cardiovascular function is compromised or in any way altered during exposure to zero gravity in space, then it stands to reason that microvascular function is also modified. We have shown that an increase in cardiac output similar to that reported during simulated weightlessness is associated with a doubling of the number of post-capillary venules and a reduction in the number of arterioles by 35%. If the weightlessness of space travel produces similar changes in cardiopulmonary volume and cardiac output, a reasonable expectation is that astronauts will undergo venous neovascularization. We have developed an animal model in which to correlate microvascular and systemic cardiovascular function. The microcirculatory preparation consists of a lightweight, thermo-neutral chamber implanted around intact skeletal muscle on the back of a rat. Using this technique, the performed microvasculature of the cutaneous maximus muscle may be observed in the conscious, unanesthetized animal. Microcirculatory variables which may be obtained include venular and arteriolar numbers, lengths and diameters, single vessel flow velocities, vasomotion, capillary hematocrit anastomoses and orders of branching. Systemic hemodynamic monitoring of cardiac output by electromagnetic flowmetry, and arterial and venous pressures allows correlation of macro- and microcirculatory changes at the same time, in the same animal. Observed and calculated hemodynamic variables also include pulse pressure, heart rate, stroke volume, total peripheral resistance, aortic compliance, minute work, peak aortic flow velocity and systolic time interval. In this manner, an integrated assessment of total cardiovascular function may be obtained in the same animal without the complicating influence of anesthetics.

NASA Discipline Number 00-00↗

Predictive models for moving contact line flows

Modeling flows with moving contact lines poses the formidable challenge that the usual assumptions of Newtonian fluid and no-slip condition give rise to a well-known singularity. This singularity prevents one from satisfying the contact angle condition to compute the shape of the fluid-fluid interface, a crucial calculation without which design parameters such as the pressure drop needed to move an immiscible 2-fluid system through a solid matrix cannot be evaluated. Some progress has been made for low Capillary number spreading flows. Combining experimental measurements of fluid-fluid interfaces very near the moving contact line with an analytical expression for the interface shape, we can determine a parameter that forms a boundary condition for the macroscopic interface shape when Ca much les than l. This parameter, which plays the role of an "apparent" or macroscopic dynamic contact angle, is shown by the theory to depend on the system geometry through the macroscopic length scale. This theoretically established dependence on geometry allows this parameter to be "transferable" from the geometry of the measurement to any other geometry involving the same material system. Unfortunately this prediction of the theory cannot be tested on Earth.

Rame, Enrique↗

Derivation of physical equations for high-speed laser welding using large language models

It is challenging to formulate complex physical phenomena that occur in a manufacturing process, particularly when the available data are limited, rendering conventional data-driven approaches ineffective. This study aims to predict humping onset in high-speed laser welding by introducing a novel framework, namely text-to-equations generative pre-trained transformer (T2EGPT). This method leverages the capabilities of large language models (LLMs), in combination with sparse experimental data and enriched literature data, to derive an interpretable and generalizable equation for predicting humping initiation. By capturing key correlations among physical parameters, T2EGPT generates a compact and dimensionless expression that accurately predicts hump formation. The equation reveals that humping arises from the interplay between inertia-driven backward melt flow and capillary-driven surface stabilization, where inertial forces drive molten metal backward and capillary forces resist surface deformation. Furthermore, compared to traditional data-driven models, T2EGPT demonstrates enhanced predictive accuracy and cross-material transferability. More broadly, this study highlights the potential of LLMs to integrate textual information with data-driven discovery, enabling the extraction of physical laws in data-scarce scientific domains.

36 MATERIALS SCIENCE↗

Experiments with an electrohydrodynamic heat pipe

The experimental results with a working model of the electrohydrodynamic (EHD) heat pipe are presented along with descriptions of the experimental device and its operation. Conclusions reached are: (1) EHD flow structures can be used to provide liquid communication between the condenser and evaporator of a heat pipe. (2) The voltage provides a remote electrical servo linkage of possible use in certain thermal control applications. (3) At least one hybrid flow structure, utilizing capillary and electrohydrodynamic forces, has been found functional. Proposed further experiments are discussed.

Jones, T. B.↗

Turbulent transport of He II in active and passive phase separators using slit devices and porous media

The turbulent transport mode of vapor liquid phase separators (VLPS) for He II has been investigated comparing passive porous plug separators with active phase separators (APS) using slits of variable flow paths within a common frame of reference. It is concluded that the basic transport regimes in both devices are identical. An integrated Gorter-Mellink (1949) equation, found previously to predict VLPS results of porous plugs, is employed to analyze APS data published in the literature. It is found that the Gorter-Mellink flow rate parameter for 9-micron and 14-micron APS slit widths are relatively independent of the slit width, having a rate constant of about 9 + or - 10 percent. This agrees with the early heat flow results for He II entropy transport at zero net mass flow in wide capillaries and slits.

Yuan, S. W. K.↗

Operation and performance of the Ciba-Corning 512 coagulation monitor during parabolic flight

The goal was to assess the functionality and evaluate the procedures and operations required to operate the Ciba-Corning 512 Coagulation Monitor during parabolic flight. This monitor determines the clotting characteristics of blood. The analyzer operates by laser detection of the cessation of blood flow in a capillary channel within a test cartridge. Test simulator results were excellent for both pre-and post-flight. In-flight results were not obtained due to the warm-up time required for the simulator. Since this is an electronic function only, the expected results on the simulator would be the same in zero-g.

Gocke, Robyn↗

Investigation of Drop Formation by a Vortex Ring in Microgravity

An investigation of drop formation by a vortex ring propagating through one or more fluid interfaces in microgravity is described. The main goal of the research is to determine the dynamics of drop formation by vortical flows in the capillary limit with large density change across the intel-face. Dimensional analysis shows that in microgravity experiments the capillary limit can be studied using a relatively large vortex ring diameter to facilitate experimental characterization of the interaction. Results obtained in density matched systems are reviewed to illustrate the complex nature of these interactions.

Bernal, Luis P.↗

Documentation of angiotensin II receptors in glomerular epithelial cells

Angiotensin II decreases glomerular filtration rate, renal plasma flow, and glomerular capillary hydraulic conductivity. Although angiotensin II receptors have been demonstrated in mesangial cells and proximal tubule cells, the presence of angiotensin II receptors in glomerular epithelial cells has not previously been shown. Previously, we have reported that angiotensin II caused an accumulation of cAMP and a reorganization of the actin cytoskeleton in cultured glomerular epithelial cells. Current studies were conducted to verify the presence of angiotensin II receptors by immunological and non-peptide receptor ligand binding techniques and to ascertain the activation of intracellular signal transduction in glomerular epithelial cells in response to angiotensin II. Confluent monolayer cultures of glomerular epithelial cells were incubated with angiotensin II, with or without losartan and/or PD-123,319 in the medium. Membrane vesicle preparations were obtained by homogenization of washed cells followed by centrifugation. Sodium dodecyl sulfate-polyacrylamide gel electrophoresis of membrane proteins followed by multiscreen immunoblotting was used to determine the presence of angiotensin II receptor type 1 (AT1) or type 2 (AT2). Angiotensin II-mediated signal transduction in glomerular epithelial cells was studied by measuring the levels of cAMP, using radioimmunoassay. Results obtained in these experiments showed the presence of both AT1 and AT2 receptor types in glomerular epithelial cells. Angiotensin II was found to cause an accumulation of cAMP in glomerular epithelial cells, which could be prevented only by simultaneous use of losartan and PD-123,319, antagonists for AT1 and AT2, respectively. The presence of both AT1 and AT2 receptors and an increase in cAMP indicate that glomerular epithelial cells respond to angiotensin II in a manner distinct from that of mesangial cells or proximal tubular epithelial cells. Our results suggest that glomerular epithelial cells participate in angiotensin II-mediated control of the glomerular filtration barrier.

Non-NASA Center↗

Flow Regime Transitions and Pressure Drop in Gas-Liquid Flows through Packed Beds in Microgravity

The Packed Bed Reactor Experiment (PBRE) focused on the hydrodynamics of gas-liquid flow in porous media, specifically on flow regime transition and pressure drop correlation. The reactor included a cylindrical test section of 60 cm in length, 5 cm in diameter and filled with 2 mm spherical glass beads. Liquid water and Nitrogen gas were flowed into a centrifugal phase separator after exiting the test section. Five absolute pressure transducers and two high-speed video cameras spanned the test section to measure the pressure drop and capture flow regime behavior. Video observations, analysis of pressure traces, and pressure drop data were used to identify flow patterns. It was found that the slope of pressure gradient data when plotted versus the gas or liquid Reynolds numbers changed when the flow regime changed. This observation was used to identify the flow regime boundaries. At high liquid flow rates (high interaction regime), dispersed bubble and pulse flow regimes were detected. At low liquid flow rates (low interaction regime), large bubble and gas channeling regimes were observed. The transition from the big bubble regime to the gas channeling regime occurred at a critical gas flow rate independent of the liquid flow rate. Similarly, the transition from the low interaction to the high interaction regime occurred at a critical liquid flow rate. For these different flow regimes, different two-phase flow friction factors and pressure gradient correlations were fitted as a function of the gas and liquid modified Reynolds numbers and Suratman number. It was found that in all the flow regimes the capillary contribution to the pressure drop is significant and can be as high as 90% of the total pressure drop.

Brian Motil↗

Characterization of voids formed during liquid impregnation of nonwoven multifilament glass networks as related to composite processing

A technique based on matching the refractive index of an invading liquid to that of a fiber mat was used to study entrapment of air ('voids') that occurs during forced in-plane radial flow into nonwoven multifilament glass networks. The usefulness of this technique is demonstrated in quantifying and mapping the air pockets. Experiments with a series of fluids with surface tensions varying from 28 x 10(exp -3) to 36 x 10(exp -3) N/m, viscosities from 45 x 10(exp -3) to 290 x 10(exp -3) Pa.s, and inlet flow rates from 0.15 x 10(exp -6) to 0.75 x 10(exp -6) m(exp 3)/s, showed that void content is a function of the capillary number characterizing the flow process. A critical value of capillary number, Ca = 2.5 x 10(exp -3), identifies a zone below which void content increases exponentially with decreasing capillary number. Above this critical value, negligible entrapment of voids is observed. Similar experiments carried out on surface treated nonwoven mats spanning a range of equilibrium contact angles from 20 deg to 78 deg showed that there is a critical contact angle above which negligible entrapment is observed. Below this value, there is no apparent effect of contact angle on the void fraction - capillary number relationship described earlier. Studies on the effect of filament wettability, and fluid velocity and viscosity on the size of the entrapment (voids) were also carried out. These indicate that larger sized entrapments which envelop more than one pore are favored by a low capillary number in comparison to smaller, pore level bubbles. Experiments were carried out on deformed mats - imposing high permeability spots at regular intervals on a background of low permeability. The effect of these spatial fluctuations in heterogeneity of the mat on entrapment is currently being studied.

Mahale, Anant D.↗