We demonstrate a simple approach to achieve three-dimensional ion momentum imaging. The method employs two complementary metal–oxide–semiconductor cameras in addition to a standard microchannel plates/phosphor screen imaging detector. The two cameras are timed to measure the decay of luminescence excited by ion hits to extract the time of flight. The achieved time resolution is better than 10 ns, which is mainly limited by camera jitters. A better than 5 ns resolution can be achieved when the jitter is suppressed.
Intelligent transportation systems (ITS) are at the forefront in advancing the way we interact with and perceive the transportation network. This revolution is fueled by the significant advancement in sensor perception technologies such as radar, lidar, and video imaging, which are the most popular modalities for ITS. Real-time perception data from these sensors allow intelligent infrastructure-side decision-making to improve the energy, efficiency, and safety at traffic intersections. As traffic departments across the United States transition from traditional loop detectors and emulators and embrace newer technologies, they are often left with a dilemma in choosing a sensor technology for infrastructure-based perception that is reliable, inexpensive, and easy to set up and that has robust performance in varying weather conditions. However, choosing a sensor that checks all these boxes is not straightforward, as every sensor type has unique benefits and drawbacks. Radar is excellent at detecting long-range vehicles and weather resistance but lacks high resolution. Lidar is expensive and weather-sensitive, while cameras provide rich visual data at a low cost but are constrained by lighting and visibility. This study examines radar, lidar, and camera sensor capabilities to ascertain whether any of these qualifies as the "best" sensor for ITS perception. While no single sensor can meet all the demands of ITS, a hybrid approach combining multiple sensor modalities like radar, lidar, and cameras offers the most robust solution for enhancing the safety and efficiency of ITS. Through this evaluation, we hope to draw attention to the necessity of the National Renewable Energy Laboratory's infrastructure perception and control framework, which presents a multisensor track data fusion engine to assimilate multiple data streams in order to provide robust and reliable perception.
A microcontroller based system has been developed for automation of the S-20 optical streak camera, which is used as a diagnostic tool to measure ultrafast light phenomenon. An 8 bit MCS family microcontroller is employed to generate all control signals for the streak camera. All biasing voltages required for various electrodes of the tubes are generated using dc-to-dc converters. A high voltage ramp signal is generated through a step generator unit followed by an integrator circuit and is applied to the camera's deflecting plates. The slope of the ramp can be changed by varying values of the capacitor and inductor. A programmable digital delay generator has been developed for synchronization of ramp signal with the optical signal. An independent hardwired interlock circuit has been developed for machine safety. A LABVIEW based graphical user interface has been developed which enables the user to program the settings of the camera and capture the image. The image is displayed with intensity profiles along horizontal and vertical axes. The streak camera was calibrated using nanosecond and femtosecond lasers.
The American Wind Wildlife Institute (AWWI – now Renewable Energy Wildlife Institute, REWI) – was appointed prime awardee of DOE award number DE-EE0007880 to lead a team of scientists, wind developers, and technology manufacturers in a collaborative evaluation of the effectiveness of a technology intended to help reduce eagle collisions with wind turbines. IdentiFlight, developed by Renewable Energy Systems (RES) in collaboration with Boulder Imaging, is an autonomous aerial monitoring and detection system. REWI partnered with ecological consultants, Western Ecosystems Technology, Inc. (WEST), to independently evaluate the performance of IdentiFlight reducing eagle collision risk under a suite of environmental conditions relative to the performance of a Biomonitor (human observer-based) Program. The project objectives were to 1) evaluate how IdentiFlight compared to biomonitors in detecting and identifying eagles under a suite of environmental conditions and 2) use the observation data to model how IdentiFlight and biomonitors reduced the eagle fatality prediction through informed curtailment. Field testing was to take place at two geographically distinct wind farms over two field seasons at each wind farm with a study design appropriate for meta-analyses across sites and years.
Abstract not provided.
This report summarizes the contributions of an intern participating in the Community College Internship (CCI) program at Fermilab, focusing on the development of a novel, non-contact, real-time radiation damage sensor technology. The core objective is to create a reliable sensor capable of measuring radiation-induced degradation on high-power targets without physical contact. The experiment involves using a Class 3B supercontinuum laser directed toward a single material sample placed within a vacuum test chamber. The laser beam reflects off the sample's surface, with changes in reflectivity, indicative of radiation damage, measured by a spectrometer positioned at the chamber’s output port. The intern’s primary responsibilities included designing an interlock system to ensure laser operational safety, developing a camera-based monitoring system using Raspberry Pi devices, and creating structural supports using 3D modeling and printing techniques. Components for the interlock and camera systems were successfully designed and ordered, with preliminary 3D models printed and refined through iterative testing. Challenges encountered in the 3D printing process, such as fragile initial prototypes and difficult support removal, were overcome by adjusting printer settings and incorporating design enhancements like chamfered edges. Future activities, pending component delivery, involve installing and configuring the interlock and camera systems, as well as further improving the structural supports. Overall, the internship significantly enhanced the intern’s technical proficiency in hardware design, software integration, and advanced 3D printing, contributing directly to Fermilab’s operational safety standards and experimental effectiveness in high-energy physics research.
This report documents the construction of a stilbene-crystal-based compact neutron scatter camera. This system is essentially identical to the MINER (Mobile Imager of Neutrons for Emergency Responders) system previously built and deployed under DNN R&D funding,1 but with the liquid scintillator in the detection cells replaced by stilbene crystals. The availability of these two systems for side-by-side performance comparisons will enable us to unambiguously identify the performance enhancements provided by the stilbene crystals, which have only recently become commercially available in the large size required (3” diameter, 3” deep).
The LSST Camera has a higher cryogenic heat load than previous CCD telescope cameras due to its large size (634 mm diameter focal plane, 3.2 Giga pixels) and its close coupled front-end electronics operating at low temperature inside the cryostat. Various refrigeration technologies are considered for this telescope/camera environment. MMR-Technology’s Mixed Refrigerant technology was chosen. A collaboration with that company was started in 2009. The system, based on a cluster of Joule-Thomson refrigerators running a special blend of mixed refrigerants is described. Both the advantages and problems of applying this technology to telescope camera refrigeration are discussed. Test results from a prototype refrigerator running in a realistic telescope configuration are reported. Current and future stages of the development program are described. (auth)
We have designed a Compton Camera (CC) to image the bio-distribution of gamma-emitting radiopharmaceuticals in mice. A CC employs the 'electronic collimation', i.e. a technique that traces the gamma-rays instead of selecting them with physical lead or tungsten collimators. To perform such a task, a CC measures the parameters of the Compton interaction that occurs in the device itself. At least two detectors are required: one (tracker), where the primary gamma undergoes a Compton interaction and a second one (calorimeter), in which the scattered gamma is completely absorbed. Eventually the polar angle and hence a 'cone' of possible incident directions are obtained (event with 'incomplete geometry'). Different solutions for the two detectors are proposed in the literature: our design foresees two similar Position Sensitive Photomultipliers (PMT, Hamamatsu H8500). Each PMT has 64 output channels that are reduced to 4 using a charge multiplexed readout system, i.e. a Series Charge Multiplexing net of resistors. Triggering of the system is provided by the coincidence of fast signals extracted at the last dynode of the PMTs. Assets are the low cost and the simplicity of design and operation, having just one type of device; among drawbacks there is a lower resolution with respect to more sophisticated trackers and full 64 channels Readout. This paper does compare our design of our two-Hamamatsu CC to other solutions and shows how the spatial and energy accuracy is suitable for the inspection of radioactivity in mice.
We are developing a superconducting camera based on microwave kinetic inductance detectors (MKIDs) to observe 100-GHz continuum with the Nobeyama 45-m telescope. A data acquisition (DAQ) system for the camera has been designed to operate the MKIDs with the telescope. This system is required to connect the telescope control system (COSMOS) to the readout system of the MKIDs (MKID DAQ) which employs the frequency-sweeping probe scheme. The DAQ system is also required to record the reference signal of the beam switching for the demodulation by the analysis pipeline in order to suppress the sky fluctuation. The system has to be able to merge and save all data acquired both by the camera and by the telescope, including the cryostat temperature and pressure and the telescope pointing. A collection of software which implements these functions and works as a TCP/IP server on a workstation was developed. The server accepts commands and observation scripts from COSMOS and then issues commands to MKID DAQ to configure and start data acquisition. We made a commissioning of the MKID camera on the Nobeyama 45-m telescope and obtained successful scan signals of the atmosphere and of the Moon.
A camera-based three-dimensional (3D) imaging system with a superb time-of-flight (TOF) resolution and multi-hit capability was recently developed for electron/ion imaging [Lee et al. J. Chem. Phys. 141, 221101 (2014)]. In this work, we report further improvement of the event rate of the system by adopting an event-driven camera, Tpx3Cam, for detecting the 2D positions of electrons, while a high-speed digitizer provides highly accurate (~30 ps) TOF information for each event at a rate approaching 1 Mhits/sec.
Commercialization of autonomous vehicle technology is a major goal of the automotive industry, thus research in this space is rapidly expanding across the world. However, despite this high level of research activity, literature detailing a straightforward and cost-effective approach to the development of an AV research platform is sparse. To address this need, we present the methodology and results regarding the AV instrumentation and controls of a 2019 Kia Niro which was developed for a local AV pilot program. This platform includes a drive-by-wire actuation kit, Aptiv electronically scanning radar, stereo camera, MobilEye computer vision system, LiDAR, inertial measurement unit, two global positioning system receivers to provide heading information, and an in-vehicle computer for driving environment perception and path planning. Robotic Operating System software is used as the system middleware between the instruments and the autonomous application algorithms. After selection, installation, and integration of these components, our results show successful utilization of all sensors, drive-by-wire functionality, a total additional power* consumption of 242.8 Watts (*Typical), and an overall cost of $118,189 USD, which is a significant saving compared to other commercially available systems with similar functionality. This vehicle continues to serve as our primary AV research and development platform.
In this paper, we present the autofocusing system of the imaging instrument to be used on IMAT, a new neutron-imaging facility under construction at the ISIS (UK) target station 2. We have compared 16 different autofocus algorithms to select the one with the best performance. The algorithms have been evaluated by using both a qualitative analysis and a quantitative one. An overall score has been computed and the “contrast based” algorithm has been selected for the autofocusing system. The adopted setup together with the described autofocusing system makes the camera a user-friendly imaging device allowing the optimization of beam time use.
Purpose: The purpose of this work was to develop a quality assurance (QA) system for high dose rate (HDR) brachytherapy to verify the absolute position of an 192Ir source in real time and to measure dwell time and position of the source simultaneously with a movie recorded by a web camera. Methods: A web camera was fixed 15 cm above a source position check ruler to monitor and record 30 samples of the source position per second over a range of 8.0 cm, from 1425 mm to 1505 mm. Each frame had a matrix size of 480×640 in the movie. The source position was automatically quantified from the movie using in-house software (built with LabVIEW) that applied a template-matching technique. The source edge detected by the software on each frame was corrected to reduce position errors induced by incident light from an oblique direction. The dwell time was calculated by differential processing to displacement of the source. The performance of this QA system was illustrated by recording simple plans and comparing the measured dwell positions and time with the planned parameters. Results: This QA system allowed verification of the absolute position of the source in real time. The mean difference between automatic and manual detection of the source edge was 0.04 ± 0.04 mm. Absolute position error can be determined within an accuracy of 1.0 mm at dwell points of 1430, 1440, 1450, 1460, 1470, 1480, 1490, and 1500 mm, in three step sizes and dwell time errors, with an accuracy of 0.1% in more than 10.0 sec of planned time. The mean step size error was 0.1 ± 0.1 mm for a step size of 10.0 mm. Conclusion: This QA system provides quick verifications of the dwell position and time, with high accuracy, for HDR brachytherapy. This work was supported by the Japan Society for the Promotion of Science Core-to-Core program (No. 23003)