Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calibration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Measurement of model propulsion system noise in a low-speed wind tunnel

Methods are presented for making overall and directional acoustic measurements with forward velocity in the Lewis 9 x 15 V/STOL Wind Tunnel. Overall acoustic measurements are discussed first. The acoustic calibration methods, instrumentation features, and types of experiments are presented. Selected data are presented as examples of the various types of overall measurements that are possible. The method of making directional acoustic measurements is then presented. The necessary alterations to the tunnel, specialized acoustic instrumentation, and calibration details are described. The results indicate that relative overall acoustic measurements can be made successfully and that directional acoustic measurements are feasible.

Diedrich, J. H.↗

General Matrix Inversion for the Calibration of Electric Field Sensor Arrays on Aircraft Platforms

We have developed a matrix calibration procedure that uniquely relates the electric fields measured at the aircraft with the external vector electric field and net aircraft charge. Our calibration method is being used with all of our aircraft/electric field sensing combinations and can be generalized to any reasonable combination of electric field measurements and aircraft. We determine a calibration matrix that represents the individual instrument responses to the external electric field. The aircraft geometry and configuration of field mills (FMs) uniquely define the matrix. The matrix can then be inverted to determine the external electric field and net aircraft charge from the FM outputs. A distinct advantage of the method is that if one or more FMs need to be eliminated or de-emphasized (for example, due to a malfunction), it is a simple matter to reinvert the matrix without the malfunctioning FMs. To demonstrate our calibration technique, we present data from several of our aircraft programs (ER-2, DC-8, Altus, Citation).

Mach, D. M.↗

Ground and In-Flight Calibration of the OSIRIS-REx Camera Suite

The OSIRIS-REx Camera Suite (OCAMS) onboard the OSIRIS-REx spacecraft is used to study the shape and surface of the mission’s target, asteroid (101955) Bennu,in support of the selection of a sampling site. We present calibration methods and results for the three OCAMS cameras—MapCam, PolyCam, and SamCam—using data from pre-flight and in-flight calibration campaigns. Pre-flight calibrations established a baseline fora variety of camera properties, including bias and dark behavior, flat fields, stray light, and radiometric calibration. In-flight activities updated these calibrations where possible, allowing us to confidently measure Bennu’s surface. Accurate calibration is critical not only for establishing a global understanding of Bennu, but also for enabling analyses of potential sampling locations and for providing scientific context for the returned sample.

E Mazarico↗

Operational support for Upper Atmosphere Research Satellite (UARS) attitude sensors

The Upper Atmosphere Research Satellite (UARS) has several sensors that can provide observations for attitude determination: star trackers, Sun sensors (gimbaled as well as fixed), magnetometers, Earth sensors, and gyroscopes. The accuracy of these observations is important for mission success. Analysts on the Flight Dynamics Facility (FDF) UARS Attitude task monitor these data to evaluate the performance of the sensors taking corrective action when appropriate. Monitoring activities range from examining the data during real-time passes to constructing long-term trend plots. Increasing residuals (differences) between the observed and expected quantities is a prime indicator of sensor problems. Residual increases may be due to alignment shifts and/or degradation in sensor output. Residuals from star tracker data revealed and anomalous behavior that contributes to attitude errors. Compensating for this behavior has significantly reduced the attitude errors. This paper discusses the methods used by the FDF UARS attitude task for maintenance of the attitude sensors, including short- and long-term monitoring, trend analysis, and calibration methods, and presents the results obtained through corrective action.

Lee, M.↗

Dual Ion Spectrometers and Their Calibration for the Fast Plasma Investigation on NASA's Magnetospheric Multiscale Mission

The scientific target of NASA's Magnetospheric Multiscale (MMS) mission is to study the fundamentally important phenomenon of magnetic reconnection. Theoretical models of this process predict a small size, on the order of hundred kilometers, for the ion diffusion region where ions are demagnetized at the dayside magnetopause. This region may typically sweep over the spacecraft at relatively high speeds of 50 km/s, requiring the fast plasma investigation (FPI) instrument suite to have an extremely high time resolution for measurements of the 3D particle distribution functions. As part of the FPI on MMS, the 16 dual ion spectrometers (DIS) will provide fast (150 ms) 3D ion velocity distributions, from 10 to 30,000 eV/q, by combining the measurements from four dual spectrometers on each of four MMS spacecraft. For any multispacecraft mission, the response uniformity among the spectrometer set assumes an enhanced importance. Due to these demanding instrument requirements and the effort of calibrating more than 32 sensors (16 × 2) within a tight schedule, a highly systematic and precise calibration was required for measurement repeatability. To illustrate how this challenge was met, a brief overview of the FPI DIS was presented with a detailed discussion of the calibration method of approach and implementation. Finally, a discussion of DIS performance results, their unit-to-unit variation, and the lessons learned from this calibration effort are presented.

Coffey, V. N.↗

Calibration Designs for Non-Monolithic Wind Tunnel Force Balances

This research paper investigates current experimental designs and regression models for calibrating internal wind tunnel force balances of non-monolithic design. Such calibration methods are necessary for this class of balance because it has an electrical response that is dependent upon the sign of the applied forces and moments. This dependency gives rise to discontinuities in the response surfaces that are not easily modeled using traditional response surface methodologies. An analysis of current recommended calibration models is shown to lead to correlated response model terms. Alternative modeling methods are explored which feature orthogonal or near-orthogonal terms.

Wind tunnel models↗

Laser-induced incandescence calibration via gravimetric sampling

Absolute calibration of laser-induced incandescence (LII) is demonstrated via comparison of LII signal intensities with gravimetrically determined soot volume fractions. This calibration technique does not rely upon calculated or measured optical characteristics of soot. The variation of the LII signal with gravimetrically measured soot volume fractions ranging from 0.078 to 1.1 ppm established the linearly of the calibration. With the high spatial and temporal resolution capabilities of laser-induced incandescence (LII), the spatial and temporal fluctuations of the soot field within a gravimetric chimney were characterized. Radial uniformity of the soot volume fraction, f(sub v) was demonstrated with sufficient averaging of the single laser-shot LII images of the soot field thus confirming the validity of the calibration method for imaging applications. As illustration, instantaneous soot volume fractions within a Re = 5000 ethylene/air diffusion flame measured via planar LII were established quantitatively with this calibration.

Choi, M. Y.↗

Cross Calibration and Validation Using CLARREO

The presentation focuses on study questions, effort, and result. Study questions include a focus on MW/LW, error sources and what can be expected, how validation will be performed and what resolution is required, and spatial resolution required for cross-calibration. Study effort includes empirical approach by examining AIRS ,IASI and MODIS cross-calibration methods already in place and estimate the number of clear and Dome C observations possible versus spatial resolution. Study results include 5000 sampler per cross-calibration recommended, insufficient cloud free and Dome C AWS observations for cross calibration and validation at 100km, and less than 20 km IFOV at 100 km swath needed to achieve sufficient samples for cross-calibration of CLARREO.

calibration↗

Method and Apparatus for Spacecraft Gyroscope Scale Factor Calibration

A method and apparatus for estimating gyro scale factor during normal spacecraft operations, using small attitude motions that are compliant with mission pointing accuracy and stability requirements and a signal processing method that specifically detects the intentionally induced motions. This process increases operational availability by avoiding the need to take the spacecraft offline for large calibration maneuvers.

Reth, Alan D↗

Hand-Eye Calibration Using Active Vision

The project described in this paper designed and implemented a hand-eye calibration method for manipulators under observation by stereo cameras. This method has been utilized on Johnson Space Center's Robonaut, and on a planetary manipulator mock-up at the Jet Propulsion Laboratory. The intent of this calibration is to improve the manipulator's hand-eye coordination.

manipulation↗

Soil Moisture Active Passive (SMAP) L-Band Microwave Radiometer Post-Launch Calibration

The SMAP microwave radiometer is a fully-polarimetric L-band radiometer flown on the SMAP satellite in a 6 AM/ 6 PM sun-synchronous orbit at 685 km altitude. Since April, 2015, the radiometer is under calibration and validation to assess the quality of the radiometer L1B data product. Calibration methods including the SMAP L1B TA2TB (from Antenna Temperature (TA) to the Earth's surface Brightness Temperature (TB)) algorithm and TA forward models are outlined, and validation approaches to calibration stability/quality are described in this paper including future work. Results show that the current radiometer L1B data satisfies its requirements.

simulation↗

Soil Moisture ActivePassive (SMAP) L-Band Microwave Radiometer Post-Launch Calibration

The SMAP microwave radiometer is a fully-polarimetric L-band radiometer flown on the SMAP satellite in a 6 AM/ 6 PM sun-synchronous orbit at 685 km altitude. Since April, 2015, the radiometer is under calibration and validation to assess the quality of the radiometer L1B data product. Calibration methods including the SMAP L1B TA2TB (from Antenna Temperature (TA) to the Earth’s surface Brightness Temperature (TB)) algorithm and TA forward models are outlined, and validation approaches to calibration stability/quality are described in this paper including future work. Results show that the current radiometer L1B data satisfies its requirements.

radiometers↗

Integrated Aero-Propulsion CFD Methodology for the Hyper-X Flight Experiment

Computational fluid dynamics (CFD) tools have been used extensively in the analysis and development of the X-43A Hyper-X Research Vehicle (HXRV). A significant element of this analysis is the prediction of integrated vehicle aero-propulsive performance, which includes an integration of aerodynamic and propulsion flow fields. This paper describes analysis tools used and the methodology for obtaining pre-flight predictions of longitudinal performance increments. The use of higher-fidelity methods to examine flow-field characteristics and scramjet flowpath component performance is also discussed. Limited comparisons with available ground test data are shown to illustrate the approach used to calibrate methods and assess solution accuracy. Inviscid calculations to evaluate lateral-directional stability characteristics are discussed. The methodology behind 3D tip-to-tail calculations is described and the impact of 3D exhaust plume expansion in the afterbody region is illustrated. Finally, future technology development needs in the area of hypersonic propulsion-airframe integration analysis are discussed.

Cockrell, Charles E., Jr.↗

L-/S-band calibration error analysis.

Results of a statistical error analysis performed to determine the degree of uncertainty encountered when calibrating steerable receiving antennas with the solar calibration method. The analysis considers the propagation of precision error indices. It is shown that a worst-case one-sigma (1 sigma) uncertainty of plus or minus 0.8 dB in system noise temperature occurs for a solar calibration at L-band. Somewhat better precision can be achieved by monitoring the antenna gain-to-noise temperature ratio at a station; a worst-case uncertainty of plus or minus 0.5 dB (1 sigma) can be realized. An error analysis is made of a method to determine absolute antenna gain based upon solar flux density. The uncertainty in this type of measurement is plus or minus 0.7 dB (1 sigma) at L- and S-band frequencies.

Taylor, R. E.↗

An interlaboratory comparison of piston-cylinder pressure calibration using the albite-breakdown reaction.

An attempt is made to compare pressure calibration methods among several laboratories in an unbiased way to produce some indication of the bandwidth of observations on the pressure of an equilibrium reaction where sources of discrepancy not resulting from pressure calibration are likely to have been eliminated. The reaction chosen is the breakdown of albite to jadeite and quartz under pressure.

Johannes, W.↗

A calibration adjustment technique combining ERB parameters from different remote sensing platforms into a long-term data set

Earth-radiation-budget (ERB) experiments on board the Nimbus-6 (ERB 6) and Nimbus-7 (ERB 7) spacecraft have measured wide-field-of-view total (0.2 to 50 micron), shortwave (0.2 to 3.8 micron), and near-infrared (0.7 to 2.8 micron) terrestrial irradiances for a joint lifetime of over 8 years. Though the spectral characteristics of both experiments are nearly identical, instrument degradation and altitude differences introduce discrepancies between the two data sets. ERB parameters from these two observing platforms may be combined into a scientifically meaningful data set only after these discrepancies are eliminated. To facilitate the creation of a long-term ERB data set, comparisons of the ERB 6 experiment irradiances with, and calibration adjustments with respect to, the corresponding ERB 7 irradiances have been performed. Two calibration methods were developed and applied to the irradiance data from 28 pairs of collocated orbits. The differential effects of altitude, illumination, albedo, and scene inhomogeneities were applied. The result is a set of calibration adjustments that adjust the ERB 6 data to match the ERB 7 data.

Ardanuy, P. E.↗

Electrochemical and Hydrodynamic Interferences on the Performances of an Oxygen Microsensor with Built-in Electrochemical Microactuator

A concept of novel electrochemical in situ self-calibration technique for an oxygen microsensor has been proposed to devise a convenient calibration method without an externally coupled apparatus. Systemic investigations on the influences of various electrochemical (pH) and hydrodynamic (solution stirring) conditions on the proposed microsensor performances are presented. The results suggest that: 1) The calibrating microenvironments can be manipulated with carefully engineered sensor designs and optimized generating signals; 2) The external oxygen permeable membrane is needed to minimize the electrochemical and hydrodynamic interferences.

Kim, Chang-Soo↗

Hawkeye Radiometric Calibration Methodology

Hawkeye is an ocean color instrument designed, manufactured and characterized at Cloud land Instruments, CA. It is a push broom instrument that has 8spectral bands similar to SeaWiFS and a spatial resolution of 120 m. Each spectral band has 1800 detectors (pixels) and all 14,000 detectors (pixels) need to be calibrated independently. This paper describes the preliminary design of on-orbit calibration method to correct for the instrument response's temperature sensitivity,scan angle dependency in radiometric sensitivity, relative spectral response (RSR),non linearity, and polarization sensitivity. We will provide a brief description on how each of the calibration parameters are used to address the instrument characteristics and how the calibration parameters are derived from instrument test data and use to retrieve ocean color products.

Lee, Shihyan↗