Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building stock modelling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

BuildingsBench: A Benchmark for Universal Building Load Forecasting [SWR-23-51]

The residential and commercial building stock in the United States is responsible for a significant percentage of energy consumption and greenhouse gas emissions. Electrification of end-uses, as well as decarbonizing the electrical grid through renewable energy sources such as solar and wind, constitutes the pathway to zero-emission buildings. Forecasting day-ahead building energy consumption is an integral part of this solution. Currently, specialized forecasting models are hand-made for each individual building, which is time-consuming, expensive, and leads to duplicated efforts. BuildingsBench is a Python software framework for training and comparing generalized machine learning models for universal building load forecasting. This challenge tasks a single foundational model to generalize its forecasts for a wide variety of buildings, across geographic regions, building types, weather patterns, and more. This software provide code for pre-training such models and subsequently evaluating their performance on a suite of hundreds of diverse real and synthetic buildings. BuildingsBench is a platform for: - Large-scale pretraining with the synthetic Buildings-900K dataset for short-term load forecasting (STLF). Buildings-900K is statistically representative of the entire U.S. building stock and is extracted from the NREL End-Use Load Profiles database. - Benchmarking on two tasks evaluating generalization: zero-shot STLF and transfer learning for STLF. We provide an index-based PyTorch Dataset for large-scale pretraining, easy data loading for multiple real building energy consumption datasets as PyTorch Tensors or Pandas DataFrames, simple (persistence) to advanced (transformer) baselines, metrics management, and more.

Emami, Patrick↗

Informing electrification strategies of residential neighborhoods with urban building energy modeling

Electrifying end uses is a key strategy to reducing GHG emissions in buildings. However, it may increase peak electricity demand that triggers the need to upgrade the existing power distribution system, leading to delays in electrification and needs of significant investment. There is also concern that building electrification may cause an increase of energy costs, leading to further energy burden for low-income communities. This study uses the urban scale building modeling tool CityBES to assess the electrification impacts of more than 43,000 residential buildings in a neighborhood of Portland, Oregon, USA. Energy efficiency upgrades were investigated on their potential to mitigate the increase of peak electricity demand and energy burden. Simulation results from the calibrated EnergyPlus models show that electrification with heat pumps for space heating and cooling as well as for domestic water heating can reduce CO2e emissions by 38%, but increase peak electricity demand by about 9% from the baseline building stock. Combining electrification measures and energy efficiency upgrades can reduce CO2e emissions by 48% while reducing peak electricity demand by 6% and saving the median household energy costs by 28%. City and utility decision makers should consider integrating energy efficiency upgrades with electrification measures as an effective residential building electrification strategy, which significantly reduces carbon emissions, caps or even decreases peak demand while reducing energy burden of residents.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Rooftop Solar Potential in Chernihiv and Lviv, Ukraine, and Efficacy of High-Resolution 3D Data Digital Twins [Slides]

NREL evaluated rooftop solar photovoltaic (PV) siting opportunities in the cities of Chernihiv and Lviv, Ukraine, leveraging very-high-resolution 3D elevation data to calculate technical potential. The study assessed total rooftop solar capacity and annual energy production. In Chernihiv and Lviv, 116,503 buildings were analyzed for their rooftop solar potential. The buildings in the study areas include a mixture of residential, commercial, and industrial buildings, characterized by diverse roof shapes and sizes. The total estimated rooftop solar capacity is 332 MWDC in Chernihiv and 873 MWDC in Lviv with annual energy production up to 376.2 GWhDC in Chernihiv and 995.5 GWhDC in Lviv. This accounting provides a clear estimate of the potential rooftop solar installations that could be realized under optimal conditions, considering both technical constraints and the geographic distribution of available rooftop space. Related to Russia's invasion of Ukraine, NREL estimates loss from buildings damaged or destroyed of 2,754 buildings, 20.15 MWDC of capacity, and 22,869 MWhDC of annual energy production in Chernihiv as well as a loss of 1,316 buildings, 34.49 MWDC of capacity, and 39,369 MWhDC of annual energy production in Lviv. The study also assessed the feasibility of adapting this methodology on a national scale using either simulated digital surface models (DSMs) or a digital twin approach. While the very-high-resolution DSM provided more precise results, the simulated DSM demonstrated reasonable accuracy for broader applications in modeling aggregated distributed solar supply. The feasibility of using a digital twin for Ukraine's national rooftop solar potential is considered promising, with certain limitations in areas with highly variable building stock and heavy war damage.

14 SOLAR ENERGY↗

Informing the planning of rotating power outages in heat waves through data analytics of connected smart thermostats for residential buildings

Abstract With climate change, heat waves have become more frequent and intense. Rotating power outages happen when the power supply is unable to meet the cooling demand increase resulting from extreme high temperatures. Power outages during heat waves expose residents to high risks of overheating. In this study, we propose a novel data-driven inverse modelling approach to inform decision makers and grid operators on planning rotating power outages. We first infer the building thermal characteristics using the connected smart thermostat data, and used the estimated thermal dynamics to simulate the thermal resilience during a heat wave event. Our proposed method was tested for the California power outage in August 2020 by using the open source Ecobee Donate Your Data dataset. We found in California the power outage should not last more than two hours during heat waves to avoid overheating risks. Informing the residents in advance so they can prepare for it through pre-cooling is a simple but effective strategy to expand the acceptable power outage duration. In addition to assisting power outage planning, the proposed method can be used for other applications, such as to evaluate a building energy efficiency policy, to examine fuel poverty, and to estimate the load shifting potential of building stocks.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

It's All About the Envelope: Prioritizing Envelope Upgrades for Electrification of Cold Climate Homes

Building decarbonization via electrification on a clean grid is the most promising climate solution proposed to date for the building sector. In cold climate zones, building electrification will be driven in large part by moving from natural gas space heating to cold climate heat pumps (CCHPs). CCHPs are commercially available today, including economical cold climate air source heat pumps (ccASHPs). But there's one big problem - wide-scale adoption of ccASHPs will dramatically increase winter peak electricity demand, even with the highest efficiency ccASHP products. Furthermore, cold climate space heating loads will drive unprecedented electric system peaks during the lowest periods of renewable generation and are likely to overwhelm existing distribution systems. This scenario is avoidable by coupling electrification with building envelope upgrades to reduce peak heating loads. This paper presents a model, built from home energy audit and research data sets, that quantifies the above challenges. Results demonstrate how weatherization efforts coupled with additional high-performance envelope upgrade measures can prepare the building stock for electrification and show the benefit these measures can bring to future utility operations. Much of this envelope upgrade work is cost-effective, according to conservative cost-benefit testing and program successes to date, and is coupled with substantial non-energy benefits. However, persistent market barriers have made scaling of envelope retrofit work challenging for decades, suggesting additional policy support is required. Lessons learned from previous policy experience, combined with new technology and administrative support, create exciting potential for this decarbonization climate solution.

air sealing↗

An Energy Calculator for Simple Commercial Buildings

According to the EIA, simple commercial buildings account for 97% of total commercial building stock. However, most simple commercial buildings for example small- to mid-sized offices, retail, schools and warehouses do not benefit from the data-driven decision-making capabilities of whole-building energy modeling. The high cost of custom modeling limits the use of energy modeling of simple buildings for new construction or retrofit measures. Lack of tools providing helpful information on interactive savings estimates creates difficulties in meeting aggressive decarbonization and energy efficiency goals for simple building designers and utility program managers. This paper reviews a beta phase Simple Building Calculator with the ability to generate relatively accurate and interactive modeling results based on a limited but robust set of inputs. It can evaluate whole-building or single measure savings in new or existing buildings, compare measure package choices, or provide simplified performance modeling for energy codes and utility incentives. The tool combines physical (annual whole building prototype simulation) and statistical modeling techniques to predict annual energy performance. It supports a variety of building characteristics for envelope, HVAC, and lighting with parameters ranging from vintage to max tech configurations, as well as support for single-zone and simple multi-zone HVAC systems. The Simple Building Calculator was designed to provide immediate feedback for otherwise computationally intensive tasks like measure comparison, development of multiple measure package combinations, or verification that measures meet efficiency targets—all with the goal of providing a tool for quick annual energy simulation of simple commercial buildings.

Hart, Reid↗

ResStock Measure Documentation: Light Air Sealing, Attic Floor Insulation, and Duct Sealing and Insulation

This report is part of series describing a variety of different ResStock(TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Light Envelope" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cold-Climate Packaged Heat Pumps - Resistance is Futile

The U.S. currently has a large market for room/zonal space conditioning equipment focused primarily on cooling, namely packaged terminal air conditioners (PTACs), packaged terminal heat pumps (PTHPs), and room air conditioners. This equipment largely relies on electric resistance for heating, particularly when outdoor temperatures fall to 40°F or below, presenting a compelling opportunity for energy savings and carbon reductions from reverse cycle heating. This paper provides an overview of cold climate packaged heat pump technologies in the market capable of high output down to outdoor temperatures of 5°F and identifies the technological and market barriers to adoption. For state-of-the-art cold climate packaged heat pumps sold in the retrofit market, defrost meltwater management is the principal barrier to implementation. An energy use analysis is conducted on state-of-the-art cold climate packaged heat pumps for heating and cooling loads by building vintage and climate zone. Potential solutions to defrost meltwater are proposed and modeled for their impact on heating energy efficiency. A national impact assessment estimates the aggregate energy savings and carbon reductions if cold climate packaged heat pumps were to replace existing PTACs and PTHPs in the U.S. building stock. A national, two-track approach is proposed for increasing market adoption in the replacement and new construction markets.

ACEEE Summer Study, cold climate, heat pumps, ccph↗

Behind-the-meter Infrastructure Costs for Electrification Progression (BICEP) Model

The Behind-the-meter Infrastructure Costs for Electrification Progression (BICEP) model quantifies the behind-the-meter (BTM) electrical upgrades required for decarbonization through electrification by comparing the expected change in capacity requirements from the electrification technologies to the existing capacity in distributed energy resources (DER) stock (including buildings).

Yoder, Tim↗

Modeled Results of Four Residential Energy Efficiency Measure Packages for Deriving Advanced Building Construction Research Targets

The Advanced Building Construction (ABC) Initiative from the U.S. Department of Energy Building Technologies Office is working to accelerate industrialized construction innovations for decarbonizing buildings. To inform performance and cost targets for research under the ABC Initiative, this analysis used the ResStock™ tool to evaluate the energy savings, utility bill impacts, and carbon emissions impacts of four simulated upgrade packages with specific target performance levels on a large sample of residential dwelling units (approximately 550,000) representative of the U.S. housing stock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Estimating internal moisture generation rates in recently constructed, occupied homes in the southeastern United States

Internal moisture generation (IMG), or moisture generated by building occupants via activities such as respiration, cooking, bathing, and cleaning, is a critical input required for design, analysis, and simulation of building enclosure and heating, ventilation, and air conditioning (HVAC) systems. Based on previously published values, ASHRAE Standard 160-2021 provides guidance for estimating IMG rates for moisture control design analysis, which is based on occupied home datasets collected in the 1980s and 1990s. Residential energy use simulation software also utilizes estimates for IMG for energy rating, energy analysis, and code compliance calculations, as specified in ANSI/RESNET/ICC Standard 301. Data quantifying IMG rates in newer homes is useful in determining the continued relevance of current design and simulation guidance, and whether the guidance represents conditions found in new housing stock. ASHRAE Research Project 1844, conducted by the Florida Solar Energy Center (FSEC), a research institute of the University of Central Florida, estimated IMG rates in newer occupied homes built since 2013 in the southeastern US using a moisture balance model approach. Furthermore, the project obtained occupied home data in cooperation with a US Department of Energy Building America research project to characterize indoor air quality (IAQ) in newer US homes, along with presence, functionality, and occupant use of control measures. Full-scale laboratory homes operating with known IMG rates were used to validate a moisture balance model and quantify the accuracy of estimates obtained when the model is applied to data from occupied homes with unknown IMG rates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Machine learning-enhanced MPC for demand flexibility in small commercial buildings: An experimental study

Small- and medium-sized commercial buildings (SMCBs) represent the majority of U.S. commercial building stock and a significant share of peak electricity demand, yet they often lack centralized building automation systems, representing a significant untapped resource for urban energy management. This infrastructure gap makes advanced control implementation challenging, limiting the potential for widespread demand flexibility. Model Predictive Control (MPC) has shown strong potential for load shifting, peak demand reduction, and cost savings, but its effectiveness is hindered by unmeasured disturbances such as internal heat gains. This paper presents a Hybrid MPC framework that integrates a physics-based gray-box building thermal model, identified using a lumped disturbance (LD) approach, with a machine learning (ML) model for forecasting unmeasured disturbances. The hybrid approach is designed for buildings with multiple individually controlled heat pump and thermostat pairs, common in SMCBs, and aims to optimize coordinated scheduling of multiple heat pumps under dynamic electricity pricing while respecting comfort constraints. The methodology is validated through both simulations of case study buildings and experimental studies at a highly-instrumented test facility. Simulation results show that the Hybrid MPC achieves substantial load shifting and peak demand reduction, approaching the performance of an ideal MPC with perfect disturbance knowledge, and outperforming a conventional MPC without disturbance forecasting. In experiments, the Hybrid MPC reduced daily HVAC energy costs by 8.7%, peak-price time load (load shifting) by 41.7%, and peak demand by 29.2% compared to baseline control, demonstrating comparable benefits to the 11.6% cost savings, 42.9% load shifting, and 23.2% peak reduction of the ideal MPC. These results demonstrate that the proposed hybrid modeling approach can significantly improve MPC performance in real-world SMCB applications without requiring additional disturbance measurements.

Demand Flexibility↗

ResStock Measure Documentation: Cold Climate Air-Source Heat Pump

This report is part of series describing a variety of different ResStock™ measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Cold Climate Air-Source Heat Pump" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The New Face of Standard 100

In January 2024, ASHRAE published a significant overhaul to ANSI/ASHRAE/IES Standard 100-2018, Energy Efficiency in Existing Buildings. You may almost not recognize it. Standard 100-2024, Energy and Emissions Building Performance Standard for Existing Buildings, now addresses both energy and emissions performance as a model building performance standard (BPS). ASHRAE Standing Standard Project Committee (SSPC) 100, with direction from ASHRAE and its Task Force for Building Decarbonization (TFBD) has been working to update the standard to make it a model for building performance standard adoption across the U.S. and internationally. Here, the new edition of Standard 100 addresses key issues of climate change surrounding building performance, including new metrics for greenhouse gas (GHG) emissions targets, continuing to support the imperative of improving our existing building stock and meeting global climate change commitments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Light Envelope Improvements

This report is part of series describing a variety of different ResStock(TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Light Envelope Improvements" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

15 GEOTHERMAL ENERGY↗

ResStock Measure Documentation: Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER) With Light Envelope Improvements

This report is part of series describing a variety of different ResStock™ measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER) with Light Envelope Improvements" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automated Calibration for Rapid Optical Spectroscopy Sensor Development for Online Monitoring

An automated platform has been developed to assist researchers in the rapid development of optical spectroscopy sensors to quantify species from spectral data. This platform performs calibration and validation measurements simultaneously. Real-time, in situ monitoring of complex systems through optical spectroscopy has been shown to be a useful tool; however, building calibration models requires development time, which can be a limiting factor in the case of radiological or otherwise hazardous systems. While calibration time can be reduced through optimized design of experiments, this study approached the challenge differently through automation. The ATLAS (Automated Transient Learning for Applied Sensors) platform used pneumatic control of stock solutions to cycle flow profiles through desired calibration concentrations for multivariate model construction. Additionally, the transients between desired concentrations based on flow calculations were used as validation measurements to understand model predictive capabilities. This automated approach yielded an incredible 76% reduction in model development time and a 60% reduction in sample volume versus estimated manual sample preparation and static measurements. The ATLAS system was demonstrated on two systems: a three-lanthanide system with Pr/Nd/Ho representing a use case with significant overlap or interference between analyte signatures and an alternate system containing Pr/Nd/Ni to demonstrate a use case in which broad-band corrosion species signatures interfered with more distinct lanthanide absorbance profiles. Both systems resulted in strong model prediction performance (RMSEP < 9%). Lastly, ATLAS was demonstrated as a tool to simulate process monitoring scenarios (e.g., column separation) in which models can be further optimized to account for day-to-day changes as necessary (e.g., baseline correction). Ultimately, ATLAS offers a vital tool to rapidly screen monitoring methods, investigate sensor fusion, and explore more complex systems (i.e., larger numbers of species).

47 OTHER INSTRUMENTATION↗

Improving energy efficiency while reducing anthropogenic heat from buildings: how retrofits influence the building stock and urban microclimate in Los Angeles

Anthropogenic heat (AH) from buildings contributes to urban overheating, especially during heat waves, yet building retrofit studies usually evaluate energy savings without assessing impacts on AH. This study quantifies how common building retrofit measures affect both building energy use and AH emissions across the City of Los Angeles. Using a bottom-up urban building energy modeling framework coupled with high-resolution local weather from the Weather Research and Forecasting model with Building Effect Parameterization (WRF-BEP), we evaluate eleven retrofit measures and two multi-measure retrofit packages. HVAC and LED lighting retrofits provide the largest city-wide annual site energy savings, while roof coating is most effective for reducing AH. A package optimized for energy savings reduces summer site energy use by about 32% (2.3 TWh), while a package incorporating AH-focused measures reduces the total AH by over 50% (137 PJ) with minimal difference in energy savings. The AH-aware package produces substantially greater urban cooling, reducing mean near-surface air temperature by up to 0.62 ℃ and peak temperature by up to 3.79 ℃. These results show that retrofit strategies selected only for energy savings may overlook major opportunities for urban heat mitigation. The study provides a framework for integrating AH into building retrofit planning and urban heat resilience policy.

Anthropogenic heat↗