Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Boundary-Aware Adversarial Learning Domain Adaption and Active Learning for Cross-Sensor Building Extraction

The use of convolutional neural networks (CNNs) for building extraction from remote sensing images has been widely studied and many public datasets have been made available for accelerating development of these CNN models. Yet adapting pretrained models at scale in real-world scenarios remains a challenging task. The main barrier is that certain new labels are still needed to compensate for domain shifting between the labeled data and new images that potentially cover new geographic locations or that are from a different sensor. In this article, we propose to add informatively labeled samples from a new image pool under the paradigm of active learning. To select the most useful samples based on model uncertainty, we first tackle the problem of uncalibrated uncertainty estimation due to distribution shifting by adapting feature extractors with boundary-based adversarial learning. Calibrated uncertainty is used as the query criterion in the active learning process, where the most uncertain samples are selected for annotation and included for model retraining. The proposed workflow was tested with three data pairs in which each workflow represents a scenario often encountered in real-world applications, including adapting pretrained models to new images collected with different sensors or to new geographic areas where appearances and types of buildings are very different. Compared to several baselines, including random sampling, temperature scaling (a well-known uncertainty calibration technique), different query strategies, and active domain adaptation methods, the proposed workflow shows that strategically querying a smaller set of samples for labeling achieves comparable or better building extraction performance. The proposed method reduces the number of labeled samples required to achieve sufficient model accuracy, thus significantly reducing hundreds of person-hours for labeled data creation. In addition, we include a few considerations when deploying this workflow in a GPU cluster that can be easily adapted to achieve operational building extraction model retraining.

97 MATHEMATICS AND COMPUTING↗

Simulation-based assessment of ASHRAE Guideline 36, considering energy performance, indoor air quality, and control stability

This study assesses American Society of Heating, Refrigerating and Air-Conditioning Engineers Guideline 36 (G36) with a typical medium office building. Specifically, this study employed a Modelica model of a variable air volume (VAV) system that serves this building, which includes components for representing indoor virus transmission and filtration. It then implemented the G36 control sequences for both water-side and air-side equipment in Python. After that, this study conducted the assessment by co-simulating G36 and the Modelica model using the Building Operations Testing Framework. Unlike existing works, this work has three unique features: (1) It considers the interactions between control sequences for water-side and air-side equipment of the studied VAV system. (2) It assesses the performance of G36 from the perspective of IAQ. (3) It examines the short-term behaviors of the studied building under G36 to understand the control stability. This assessment confirms significant energy savings from G36, largely because of the interaction between supply air temperature and hot water controls. It also reveals a trade-off between the ability to slow the spread of virus and the energy performance via demand controlled ventilation. Lastly, it emphasizes the necessity of tuning local feedback control when implementing G36.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An open control sequence specification to scale building demand flexibility via analytics software

For over two decades, researchers and practitioners have showcased the ability of large commercial buildings to provide grid services by shedding or shifting load. Various utility demand response (DR) and virtual power plant (VPP) programs throughout the United States are presently utilizing these demand-side resources. However, growth of these programs have been limited, in part due to the high cost necessary to integrate the DR control strategies into the building automation system (BAS). Implementing these strategies involves adjusting control sequences, necessitating dozens of hours of customized programming per building, limiting their adoption to large organizations and progressive owners. Recent efforts by researchers and industry have demonstrated the capability of energy management and information systems (EMIS), originally designed for fault detection and diagnostics, to interface with existing BAS and perform supervisory control to optimize building operations. While these approaches are quickly being adopted by industry, demand flexibility (DF) control strategies remain limited in product offerings. One of the challenges is the lack of documented best-practice DF sequences, despite the rich literature on field implementations. This paper develops a new open-specification for a zone-based temperature adjustment shed strategy for commercial building HVAC systems, describing the specification’s implementation in two EMIS tools in both experimental and field settings. Both implementations successfully reduced electric load by at least 40% on average during the called event, while maintaining temperature limits. This study’s detailed process from specification to deployment shows the potential for scalability as well as highlights challenges related to integration with heterogeneous BAS products.

Granderson, Jessica↗

A labeled dataset for building HVAC systems operating in faulted and fault-free states

Abstract Open data is fueling innovation across many fields. In the domain of building science, datasets that can be used to inform the development of operational applications - for example new control algorithms and performance analysis methods - are extremely difficult to come by. This article summarizes the development and content of the largest known public dataset of building system operations in faulted and fault free states. It covers the most common HVAC systems and configurations in commercial buildings, across a range of climates, fault types, and fault severities. The time series points that are contained in the dataset include measurements that are commonly encountered in existing buildings as well as some that are less typical. Simulation tools, experimental test facilities, and in-situ field operation were used to generate the data. To inform more data-hungry algorithms, most of the simulated data cover a year of operation for each fault-severity combination. The data set is a significant expansion of that first published by the lead authors in 2020.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of A Hardware-In-the-Loop (HIL) Testbed for Cyber-Physical Security in Smart Buildings

As smart buildings move towards open communication technologies, providing access to the Building Automation System (BAS) through the building's intranet, or even remotely through the Internet, has become a common practice. However, BAS was historically developed as a closed environment and designed with limited cyber-security considerations. Thus, smart buildings are vulnerable to cyber-attacks with the increased accessibility. This study introduces the development and capability of a Hardware-in-the-Loop (HIT) testbed for testing and evaluating the cyber-physical security of typical BASs in smart buildings. The testbed consists of three subsystems: (1) a real-time HIL emulator simulating the behavior of a virtual building as well as the Heating, Ventilation, and Air Conditioning (HVAC) equipment via a dynamic simulation in Modelica; (2) a set of real HVAC controllers monitoring the virtual building operation and providing local control signals to control HVAC equipment in the HIL emulator; and (3) a BAS server along with a web-based service for users to fully access the schedule, setpoints, trends, alarms, and other control functions of the HVAC controllers remotely through the BACnet network. The server generates rule-based setpoints to local HVAC controllers. Based on these three subsystems, the HIL testbed supports attack/fault-free and attack/fault-injection experiments at various levels of the building system. The resulting test data can be used to inform the building community and support the cyber-physical security technology transfer to the building industry.

Li, Guowen↗

Generation and representation of synthetic smart meter data

Advanced energy algorithms running at big-data scale will be necessary to identify, realize, and verify energy savings to meet government and utility goals of building energy efficiency. Any algorithm must be well characterized and validated before it is trusted to run at these scales. Smart meter data from real buildings will ultimately be required for the development, testing, and validation of these energy algorithms and processes. However, for initial development and testing, smart meter data are difficult to work with due to privacy restrictions, noise from unknown sources, data accessibility, and other concerns which can complicate algorithm development and validation. This paper describes a new methodology to generate synthetic smart meter data of electricity use in buildings using detailed building energy modeling, which aims to capture the variability and stochastics of real energy use in buildings. The methodology can create datasets tailored to represent specific scenarios with known truth and controllable amounts of synthetic noise. Knowledge of ground truth also allows the development and validation of enhanced processes which leverage building metadata, such as building type or size (floor area), in addition to smart meter data. The methodology described in this paper includes the key influencing factors of real-world building energy use including weather data, occupant-driven loads, building operation and maintenance practices, and special events. Data formats to support workflows leveraging both synthetic meter data and associated metadata are proposed and discussed. Finally, example use cases of the synthetic meter data are described to illustrate potential applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sensor Impact Evaluation and Verification Technical Advisory Group Meeting Minutes

This report provides the technical advisory group meeting minutes and summary of detailed discussions for future development of sensor impact evaluations and verifications. Methods for sensor configuration/deployment have critical impacts on energy-efficient building control and thermal comfort. However, traditional sensor techniques for building operation and fault detection and diagnostics (FDD) are not optimal in terms of energy efficiency and thermal comfort, and their global effects are not thoroughly investigated. In an effort to address and overcome this limitation, a 3 year project, Sensor Impact Evaluation and Verification, was proposed. The multi-laboratory team—the US Department of Energy’s Oak Ridge National Laboratory (ORNL), Pacific Northwest National Laboratory (PNNL), and the National Renewable Energy Laboratory (NREL)—is conducting early-stage R&D to provide technical supports and guidelines for sensor design in building/HVAC systems to optimize building energy use, FDD, thermal comfort, and grid efficiency. The overall goal of this project is to develop a framework that enables quantitative evaluation of the impact of sensors on building HVAC control, FDD, and consequently, building energy efficiency and thermal comfort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing Cost-Optimal Battery Energy and Solar-Plus-Storage Systems for Federal Customers: A Nationwide Assessment: Preprint

Prior research has identified that the financial viability of behind-the-meter battery energy storage systems is heavily dependent on technology cost, utility rate structure, energy consumption patterns, and co-deployment with synergistic technologies like solar photovoltaics (PV), among other factors. This study builds on existing research by comprehensively evaluating the economics of battery energy storage systems (BESS) and solar-plus-storage systems for a reference office building at 755 reference sites under 834 utility rates, and four storage capital cost scenarios. Results indicate that even with dramatic cost reductions, BESS is likely to be cost-effective only under utility rates that include demand charges, and possibly include time-of-use (TOU) pricing as well. Even under these utility rates, BESS systems provide marginal savings, and office building operators are unlikely to deploy the technology for cost savings alone. Solar-plus-storage systems provide more savings than BESS and allow for larger economic storage capacities. Solar-plus-storage provides compelling savings opportunities at baseline prices, and even at capital costs 25% higher than baseline. Solar-plus-storage is most effective where there are demand charges and energy pricing schemes include TOU pricing, or where electricity is expensive (at least $0.30/kWh). Our case studies illustrate that the presence of demand charges, even at similar energy costs, can be the deciding factor in BESS and solar-plus-storage viability. The findings and maps from this assessment may be of use to planners, building owners, and developers looking for potentially economic storage opportunities.

battery energy storage systems↗

Testing and validating SMDS algorithms implemented in the cloud

Pacific Northwest National Laboratory (PNNL) provided technical assistance to NorthWrite Inc. under the Small Business Vouchers (SBV) Pilot. NorthWrite delivered services to owners of small commercial buildings, using a cloud-based service to monitor, control, and optimize building operations, saving energy and reducing operating costs for the owners while ensuring that occupant comfort needs were consistently met. NorthWrite had a longstanding desire to add a new suite of diagnostic capabilities to their service offering and had been trying, without success, to incorporate several diagnostic algorithms published by PNNL. These algorithms arise from research previously supported by BTO. Through the SBV awarded to NorthWrite, PNNL made available technical knowledge regarding the derivation and application of the following sets of algorithms for use in the NorthWrite Cloud-based service delivery system: • algorithms for monitoring rooftop packaged air conditioners and heat pumps (often referred to as rooftop units or RTUs) and diagnosing faults in these units, • advanced algorithms for automated fault detection and diagnosis of other equipment found in small buildings, and • algorithms for identifying, prioritizing, and assessing the economic effectiveness of implementing energy saving measures in small commercial buildings based on sensed data. The PNNL researchers involved were the original developers of these algorithms, had a unique understanding of the derivation of the algorithms, and had the source data used for this derivation. Further, the PNNL researchers had extensive experience using these algorithms in the laboratory, unique experience applying these algorithms in real-world small commercial buildings and could solve a number of key problems that NorthWrite and other users faced in using these algorithms at scale. In addition, PNNL had recently installed a pair of RTUs in a laboratory setting that were instrumented and connected with data acquisition systems that provided a unique test rig for validating the algorithms before NorthWrite began to deploy their new services in the field.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Human Factors Directions for Civil Aviation

Despite considerable progress in understanding human capabilities and limitations, incorporating human factors into aircraft design, operation, and certification, and the emergence of new technologies designed to reduce workload and enhance human performance in the system, most aviation accidents still involve human errors. Such errors occur as a direct or indirect result of untimely, inappropriate, or erroneous actions (or inactions) by apparently well-trained and experienced pilots, controllers, and maintainers. The field of human factors has solved many of the more tractable problems related to simple ergonomics, cockpit layout, symbology, and so on. We have learned much about the relationships between people and machines, but know less about how to form successful partnerships between humans and the information technologies that are beginning to play a central role in aviation. Significant changes envisioned in the structure of the airspace, pilots and controllers' roles and responsibilities, and air/ground technologies will require a similarly significant investment in human factors during the next few decades to ensure the effective integration of pilots, controllers, dispatchers, and maintainers into the new system. Many of the topics that will be addressed are not new because progress in crucial areas, such as eliminating human error, has been slow. A multidisciplinary approach that capitalizes upon human studies and new classes of information, computational models, intelligent analytical tools, and close collaborations with organizations that build, operate, and regulate aviation technology will ensure that the field of human factors meets the challenge.

Hart, Sandra G.↗

Grazer-induced changes in molecular signatures of cyanobacteria

Algal biomass production is an emerging renewable source of fuels, nutrients, manufacturing materials, and pharmaceuticals. Industrial-scale production is predominantly performed in open raceway ponds that are inexpensive to build, operate, and maintain compared to closed bioreactors. However, these open pond systems suffer from increased opportunities for biological contamination from predators, pathogens, and competitors, which result in reduced biomass quality and yields and often the complete destruction of the crop over a short period of time. Early detection of contaminants is a necessary step of integrated pest management for triggering and informing interventions to prevent crop losses. To develop a sensitive method of detection utilizing mass spectrometry (MS), we used three methods – imaging mass spectrometry (imaging MS), liquid chromatography MS/MS (LC-MS/MS) combined with molecular networking, and gas chromatography MS/MS (GC–MS/MS) – to observe and identify molecular signatures from a model predator-prey system of the heterolobosean amoeba HGG1 preying on the filamentous cyanobacterium Anabaena sp. PCC 7120. Imaging MS enabled the association of molecules with the crop, the predator, or the activity of protozoan grazing, while LC-MS/MS-based molecular networking identified a subset of the grazing-specific signals as the chlorophyll breakdown products pyropheophytin, pheophorbide A, and pyropheophorbide. Application of MS techniques to other amoebacyanobacterial predator-prey pairs allowed categorization of grazing signatures as universal or specific to the species of prey, predator, or the prey-predator pairing, indicating that MS-based techniques can distinguish crops from competitors and potentially identify predators. Finally, GCMS/MS was shown to be capable of monitoring novel volatile organic compounds (VOCs), including those predicted to be released through chlorophyll breakdown, in the headspace over algal cultures under predation. Furthermore, these results demonstrate that the combination of multiple MS technologies creates a predictive framework to identify and catalog relevant molecular signatures for informing crop protection strategies.

09 BIOMASS FUELS↗

Assessing the use of portable air cleaners for reducing exposure to airborne diseases in a conference room with thermal stratification

The COVID-19 pandemic has highlighted the need for strategies that mitigate the risk of aerosol disease transmission in indoor environments with different ventilation strategies. It is necessary for building operators to be able to estimate and compare the relative impacts of different mitigation strategies to determine suitable strategies for a particular situation. Using a validated CFD model, this study simulates the dispersion of exhaled contaminants in a thermally stratified conference room with overhead heating. The impacts of portable air-cleaners (PACs) on the room airflow and contaminant distribution were evaluated for different PAC locations and flow rates, as well as for different room setups (socially distanced or fully occupied). To obtain a holistic view of a strategy's impacts under different release scenarios, we simultaneously model the steady-state distribution of aerosolized virus contaminants from eight distinct sources in 18 cases for a total of 144 release scenarios. The simulations show that the location of the source, the PAC settings, and the room set-up can impact the average exposure and PAC effectiveness. For this studied case, the PACs reduced the room average exposure by 31%-66% relative to the baseline case. Some occupant locations were shown to have a higher-than-average exposure, particularly those seated near the airflow outlet, and occupants closest to sources tended to see the highest exposure from said source. We found that these PACs were effective at reducing the stratification caused by overhead heating, and also identified at least one sub-optimal location for placing a PAC in this space.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of strategies to meet ASHRAE S241 infectious aerosol control targets by space type and region using EnergyPlus™ simulations

Professional organizations, such as ASHRAE, have recently proposed new voluntary standards for controlling infectious aerosols. Specifically, ASHRAE Standard 241 (S241) defines equivalent clean air targets for a range of space types that can be met through combinations of mitigation measures. This paper seeks to inform the selection of measures by space type and climate zone through building simulations that quantify the impacts of increased outdoor air ventilation; increasing filtration and/or adding germicidal ultraviolet (GUV) in the central heating, ventilation, and air-conditioning (HVAC) systems; or using portable air cleaners (PACs), upper room GUV, or whole room GUV approaches to increase equivalent clean air delivery. The measures are assessed individually and in practical combinations for their ability to meet S241 in four space types (offices, classrooms, dining areas, and healthcare waiting rooms) using prototype buildings modeled using EnergyPlus. The mitigation measures are compared holistically against baseline building operations using metrics for equivalent clean air, energy, and comfort. The results in this study show that single measures can meet S241 for offices with minimal impacts on energy and comfort, while either upper room GUV systems or combinations of measures such as MERV 13 HVAC filtration with PACs are needed to meet S241 for classrooms. The dining area and healthcare waiting room targets cannot be met in this study when assuming design occupancy and MS2 as the challenge agent, even when combining multiple measures together. This paper provides valuable considerations when designing measures to meet S241 for a range of spaces and scenarios.

GUV↗

Rubisco activity and activation state dictate photorespiratory plasticity in Betula papyrifera acclimated to future climate conditions

Plant metabolism faces a challenge of investing enough enzymatic capacity to a pathway without overinvestment. As it takes energy and resources to build, operate, and maintain enzymes, there are benefits and drawbacks to accurately matching capacity to the pathway influx. The relationship between functional capacity and physiological load could be explained through symmorphosis, which would quantitatively match enzymatic capacity to pathway influx. Alternatively, plants could maintain excess enzymatic capacity to manage unpredictable pathway influx. In this study, we use photorespiration as a case study to investigate these two hypotheses in Betula papyrifera. This involves altering photorespiratory influx by manipulating the growth environment, via changes in CO 2 concentration and temperature, to determine how photorespiratory capacity acclimates to environmental treatments. Surprisingly, the results from these measurements indicate that there is no plasticity in photorespiratory capacity in B. papyrifera, and that a fixed capacity is maintained under each growth condition. The fixed capacity is likely due to the existence of reserve capacity in the pathway that manages unpredictable photorespiratory influx in dynamic environments. Additionally, we found that B. papyrifera had a constant net carbon assimilation under each growth condition due to an adjustment of functional rubisco activity driven by changes in activation state. These results provide insight into the acclimation ability and limitations of B. papyrifera to future climate scenarios currently predicted in the next century.

59 BASIC BIOLOGICAL SCIENCES↗

Experimental evaluation of respiratory droplet spread to rooms connected by a central ventilation system

This article presents results from an experimental study to ascertain the transmissibility of the SARS-CoV-2 virus between rooms in a building that are connected by a central ventilation system. Respiratory droplet surrogates made of mucus and virus mimics were released in one room in a test building and measurements of concentration levels were made in other rooms connected via the ventilation system. The paper presents experimental results for different ventilation system configurations, including ventilation rate, filtration level (up to MERV-13), and fractional outdoor air intake. The most important finding is that respiratory droplets can and do transit through central ventilation systems, suggesting a mechanism for viral transmission (and COVID-19 specifically) within the built environment in reasonable agreement with well-mixed models. We also find the deposition of these droplets on room walls to be negligibly small. Furthermore, the energy use impact of the different configuration settings is also quantified to help inform intelligent building operation that can simultaneously address energy use and occupant health.

60 APPLIED LIFE SCIENCES↗

Extraction and Analysis of Time Series Data from Building Automation Systems Using Large Language Models

Semantic schemas like Haystack 4, Brick and ASHRAE standard 223 enable the structured, standardized, and machine-readable representation of building data, facilitating interoperability, data integration, and advanced analytics. However, extracting information from these models requires specialized expertise in SPARQL and other programming languages, skills that are not commonly found among building professionals. Recent advancements in Large Language Models (LLMs), such as ChatGPT, enable the construction of queries using natural language, making it easier for individuals to interact with these systems in a manner that resembles everyday speech. However, these methods have not yet been tested on building semantic ontologies. This paper introduces a novel workflow and tool for enabling users to ask questions about a specific building's data, using natural language and receive answers automatically generated by GPT-4o. Our approach integrates semantic ontologies with advanced LLM capabilities to automate three critical steps: (1) generating SPARQL queries to retrieve time series references from ontological models, (2) extracting the corresponding time series data from the Building Automation System, and (3) performing computations and visualizations tailored to the user's query. The proposed method simplifies access to BAS data, allowing both domain experts and non-specialists to conduct sophisticated analyses without needing extensive technical knowledge of semantic web technologies. By demonstrating this pipeline, we facilitate more accessible and scalable data-driven decision-making in building operations and management.

Mulayim, Ozan Baris↗

Proving the Business Case for Building Analytics

As building monitoring becomes more common, facilities teams are faced with an overwhelming amount of data. These data do not typically lead to insights or corrective actions unless they are stored, organized, analyzed, and prioritized in automated ways. Buildings are full of energy savings potential that can be uncovered with the right analysis. With analytic software applied to everyday building operations, owners are using data to their advantage and realizing cost savings through improved energy management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

What's in a Name? Developing a Standardized Taxonomy for HVAC System Faults

Faults occurring in heating, ventilation and air-conditioning (HVAC) systems have significantly negative impacts on building energy consumption, occupant comfort, and indoor air quality. In the past thirty years, extensive research has been conducted on fault detection and diagnostics (FDD) methods, and there are now dozens of commercially available FDD software tools. Growing adoption of FDD tools has the potential to generate a massive and useful data set on fault characteristics. However, the lack of a unifying taxonomy is a significant barrier to efficient analysis and evaluation of FDD outputs. Therefore, there is a strong need to develop a robust taxonomy which can better represent and interpret FDD output data. This paper documents the development of a unifying taxonomy for HVAC system faults in commercial buildings, with initial focus on air handling units, variable air volume terminal units, and roof top unit systems. The developed fault taxonomy employs both a physical hierarchy of HVAC equipment and a cause-effect relationship model as tools to better understand and support root cause analysis for HVAC faults. A variable air volume terminal unit is used as an example to demonstrate the application of the developed fault taxonomy. The taxonomy has short-term application in a major U.S. study on fault prevalence, and promises longer term benefits to FDD software developers and building operators by creating a foundation for improved approaches to identifying and resolving HVAC faults.

Chen, Yimin↗