Building America Case Study: Field Testing an Unvented Roof with Fibrous Insulation and Tiles, Orlando, Florida

This research is a test implementation of an unvented tile roof assembly in a hot-humid climate (Orlando, FL; Zone 2A), insulated with air permeable insulation (netted and blown fiberglass). Given the localized moisture accumulation and failures seen in previous unvented roof field work, it was theorized that a 'diffusion vent' (water vapor open, but air barrier 'closed') at the highest points in the roof assembly might allow for the wintertime release of moisture, to safe levels. The 'diffusion vent' is an open slot at the ridge and hips, covered with a water-resistant but vapor open (500+ perm) air barrier membrane. As a control comparison, one portion of the roof was constructed as a typical unvented roof (self-adhered membrane at ridge). The data collected to date indicate that the diffusion vent roof shows greater moisture safety than the conventional, unvented roof design. The unvented roof had extended winter periods of 95-100% RH, and wafer (wood surrogate RH sensor) measurements indicating possible condensation; high moisture levels were concentrated at the roof ridge. In contrast, the diffusion vent roofs had drier conditions, with most peak MCs (sheathing) below 20%. In the spring, as outdoor temperatures warmed, all roofs dried well into the safe range (10% MC or less). Some roof-wall interfaces showed moderately high MCs; this might be due to moisture accumulation at the highest point in the lower attic, and/or shading of the roof by the adjacent second story. Monitoring will be continued at least through spring 2016 (another winter and spring).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: High-Velocity Small-Diameter Duct System, Pittsburgh, Pennsylvania

This study tests the performance of a variable airflow small-diameter duct heating, ventilation, and air conditioning (HVAC) system in a new construction unoccupied low-load test house in Pittsburgh, Pennsylvania. The duct system was installed entirely in conditioned space and was operated from the winter through summer seasons. Measurements were collected on the in-room temperatures and energy consumed by the air handler and heat pump unit. Operation modes with three different volumes of airflow were compared to determine the ideal airflow scenario that maximizes room-to-room thermal uniformity while minimizing fan energy consumption. Black felt infrared imagery was used as a measure of diffuser throw and in-room air mixing. Measured results indicate the small-diameter, high velocity airflow system can provide comfort under some conditions. Solar heat gains resulted in southern rooms drifting beyond acceptable temperature limits. Insufficient airflow to some bedrooms also resulted in periods of potential discomfort. Homebuilders or HVAC contractors can use these results to assess whether this space conditioning strategy is an attractive alternative to a traditional duct system. The team performed a cost analysis of two duct system configurations: (1) a conventional diameter and velocity duct system, and (2) the small-diameter duct system. This work applies to both new and retrofit homes that have achieved a low heating and cooling density either by energy conservation or by operation in a mild climate with few heating or cooling degree days. Guidance is provided on cost trade-offs between the conventional duct system and the small-diameter duct system.

Building America↗

Building America Case Study: High-Velocity Small-Diameter Duct System, Pittsburgh, Pennsylvania

This study tests the performance of a variable airflow small-diameter duct heating, ventilation, and air conditioning (HVAC) system in a new construction unoccupied low-load test house in Pittsburgh, Pennsylvania. The duct system was installed entirely in conditioned space and was operated from the winter through summer seasons. Measurements were collected on the in-room temperatures and energy consumed by the air handler and heat pump unit. Operation modes with three different volumes of airflow were compared to determine the ideal airflow scenario that maximizes room-to-room thermal uniformity while minimizing fan energy consumption. Black felt infrared imagery was used as a measure of diffuser throw and in-room air mixing. Measured results indicate the small-diameter, high velocity airflow system can provide comfort under some conditions. Solar heat gains resulted in southern rooms drifting beyond acceptable temperature limits. Insufficient airflow to some bedrooms also resulted in periods of potential discomfort. Homebuilders or HVAC contractors can use these results to assess whether this space conditioning strategy is an attractive alternative to a traditional duct system. The team performed a cost analysis of two duct system configurations: (1) a conventional diameter and velocity duct system, and (2) the small-diameter duct system. This work applies to both new and retrofit homes that have achieved a low heating and cooling density either by energy conservation or by operation in a mild climate with few heating or cooling degree days. Guidance is provided on cost trade-offs between the conventional duct system and the small-diameter duct system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Evaluation of Residential Integrated Space/Water Heat Systems, Illinois and New York (Fact Sheet)

This multi-unit field demonstration of combined space and water heating (combi) systems was conducted to help document combi system installation and performance issues that needed to be addressed through research. The objective of the project was to put commercialized forced-air tankless combi units into the field through local contractors that were trained by manufacturers and GTI staff under the auspices of utility-implemented Emerging Technology Programs. With support from PARR, NYSERDA and other partners, the project documented system performance and installations in Chicago and New York. Combi systems were found to save nearly 200 therms in cold climates at efficiencies between about 80% and 94%. Combi systems using third-party air handler units specially designed for condensing combi system operation performed better than the packaged integrated combi systems available for the project. Moreover, combi systems tended to perform poorly when the tankless water heaters operating at high turn-down ratios. Field tests for this study exposed installation deficiencies due to contractor unfamiliarity with the products and the complexity of field engineering and system tweaking to achieve high efficiencies. Widespread contractor education must be a key component to market expansion of combi systems. Installed costs for combi systems need to come down about 5% to 10% to satisfy total resource calculations for utility-administered energy efficiency programs. Greater sales volumes and contractor familiarity can drive costs down. More research is needed to determine how well heating systems such as traditional furnace/water heater, combis, and heat pumps compare in similar as-installed scenarios, but under controlled conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Retrofitting a 1960s Split-Level, Cold-Climate Home, Westport, Connecticut; Whole-House Solutions for Existing Homes, Energy Efficiency & Renewable Energy (EERE)

??National programs such as Home Performance with ENERGY STAR(R) and numerous other utility air sealing programs have brought awareness to homeowners of the benefits of energy efficiency retrofits. Yet, these programs tend to focus on the low-hanging fruit: air-sealing the thermal envelope and ductwork where accessible, switch to efficient lighting, and low-flow fixtures. At the other end of the spectrum, deep-energy retrofit programs are also being encouraged by various utilities across the country. While deep energy retrofits typically seek 50% energy savings, they are often quite costly and most applicable to gut-rehab projects. A significant potential for lowering energy usage in existing homes lies between the low hanging fruit and deep energy retrofit approaches - retrofits that save approximately 30% in energy over the existing conditions. A key is to be non-intrusive with the efficiency measures so the retrofit projects can be accomplished in occupied homes. This cold climate retrofit project involved the design and optimization of a home in Connecticut that sought to improve energy savings by at least 30% (excluding solar PV) over the existing home's performance. This report documents the successful implementation of a cost-effective solution package that achieved performance greater than 30% over the pre-retrofit - what worked, what did not, and what improvements could be made. Confirmation of successfully achieving 30% source energy savings over the pre-existing conditions was confirmed through energy modeling and comparison of the utility bills pre- and post- retrofit.

1960 split level↗

NORM in Building Materials: A Case Study in Releasing and Disposing of Building Debris within the DOE System - 18123

In 2013, the Office of Management and Budget issued Memorandum 2013-02, clarifying its 'Freeze the Footprint' policy. Memorandum 2013-02 requires that all federal agencies maintain or reduce their total square footage, within each subsequent year, from a FY2012 baseline. Memorandum 2013-02 also requires that total square footage remain constant with respect to the type/intended use of a building. At Los Alamos National Laboratory (LANL), this means that new construction cannot occur without demolition of equivalent (both in type and square footage) building(s). Since 2013, decommissioning and demolition of aging, unused facilities at LANL has increased. In 2016, the TA16-280 building complex was scheduled for demolition. TA16-280 is a former high explosives (HE) processing facility that consists of six buildings connected to each other via weatherproof walkways. It was constructed in the 1950's and has been subsequently used for HE shipping, receiving, and storage. Interviews with radiation protection staff suggest that some of the buildings within the complex may have been used to store depleted uranium metal parts in a non-dispersible form. It is LANL policy to conduct decommissioning surveys for radioactive materials when building history cannot confirm that a structure is radiologically non-impacted. LANL follows the Multi-Agency Radiation Survey and Assessment of Materials and Equipment (MARSAME) process to develop its surveys and clear structures from radiological control. After clearance, a structure may be dispositioned as non-regulated waste, at a significant cost savings compared to regulated disposition pathways such as low-level waste. MARSAME measurements conducted in the 16-280 complex were elevated compared to reference measurements of surrogate materials, and a majority of the survey units failed to pass indistinguishable from background (IFB), which is LANL's unregulated clearance criteria. Further measurements conducted both in situ and in the laboratory indicated the presence of naturally-occurring thorium in several building materials including: poured concrete, the glaze atop ceramic blast tiles, and the porcelain enamel on the exterior of blast-proof ceiling lamps. Other than naturally-occurring thorium, there were no elevated radionuclide concentrations detected in building materials. It should be noted that there was no history of thorium use in the 16-280 complex, and the material in question was in all cases fixed to and within the building materials in question. Except in certain specific cases, such material is exempt from regulation under the Atomic Energy Act of 1954 [3], as amended, and is therefore exempt from regulation under the Nuclear Regulatory Commission, the Department of Energy, and agreement state regulatory frameworks. Despite this regulatory exemption, disposition of material from the 16-280 complex proved to be challenging, principally because local industrial landfills stipulate 'No radioactive material' in their Waste Acceptance Criteria. This disconnect between what is regulated and what is disposable creates a situation where some DOE sites find it easier to disposition property as Low Level Waste in lieu of pursuing a non-regulated disposition pathway. This presentation will explore the specifics of the 16-280 decommissioning project as well as the implications of the release/disposition disconnect for naturally occurring radioactive material and project planning at LANL. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Building America Case Study: Photovoltaic Systems with Module-Level Power Electronics

Direct current (DC) power optimizers and microinverters (together known as module-level power electronics, or MLPE) are one of the fastest growing market segments in the solar industry. According to GTM Research in The Global PV Inverter Landscape 2015, over 55% of all residential photovoltaic (PV) installations in the United States used some form of MLPE in 2014.

14 SOLAR ENERGY↗

The effect of building retrofit measures on CO2 emission reduction – A case study with U.S. Medium office buildings

Building retrofit has great potential to reduce CO2 emissions since buildings are responsible for 36% of emissions in the United States. Several existing studies have examined the effect of building retrofit measures on CO2 emission reduction. However, these studies oversimplified emission factors of electricity by adopting constant annual emission factors. This study uses hourly emission factors of electricity to analyze the effect of building retrofit measures on emission reduction using U.S. medium office buildings as an example. We analyzed CO2 emission reduction effects of eight building retrofit measures that related to envelop and mechanical system in five locations: Tampa, San Diego, Denver, Great Falls, and International Falls. The main findings are: (1) estimating CO2 emission reduction with constant emission factors overestimates the emission reduction for most measures in San Diego, while it underestimates the emission reduction for most measures in Denver and International Falls; (2) The same retrofit measure may have different effects in CO2 emission reduction depending on the climates. For instance, improving lighting efficiency and improving equipment efficiency have less impacts in emission reduction in cold climates than hot climates; and (3) The most energy efficient measure may not be the most emission efficient measure. For example, in Great Falls, the most energy efficient measure is improving equipment efficiency, but the most emission efficient measure is improving heating efficiency.

Lou, Yingli↗

A Process for Defining Prototype Building Models: Courthouse Case Study for U.S. Commercial Energy

Buildings currently consume 36% of the world’s energy and contribute nearly 40% of CO 2 emissions. Many countries desire to generate virtual models of their nation’s buildings in order to coordinate research activities and inform market opportunities for a more sustainable built environment. The United States Department of Energy uses a suite of Commercial Prototype Building Models, which currently includes 16 building types and covers 80% of US commercial floorspace. Efforts are underway to expand this suite by developing prototype models for additional building types. In this paper, we outline a systematic approach to defining the building, collecting relevant information and creating a flexible model while doing so in the pragmatic context of a courthouse building. Informed by building design guides, databases, documented projects and inputs from courthouse design experts, we define a small, 69,324 ft 2 (6440 m 2 ), four-courtroom, low-rise courthouse as the prototype to represent an average-size courthouse in the US. We present building characteristics relevant for energy model development and provide the rationale for their selection. These details combined with climate- and construction-vintage-specific requirements for the building envelope and systems from building standards will be used for developing the courthouse model for the Commercial Prototype Building Models suite. The comprehensive information presented will also guide model modification to capture the dynamics of smaller or larger courthouses more accurately for building or system size-specific research.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The interactive indoor-outdoor building energy modeling for enhancing the predictions of urban microclimates and building energy demands

There is a lack of an urban building energy modeling framework that considers the influence of surrounding buildings and local urban climate on building thermal performance. This can lead to inaccurate results since the thermal performance of individual buildings is heavily influenced by their surrounding built and climatic environment. This study establishes an interactive indoor-outdoor building energy modeling method to enhance the predictions of urban microclimates and building energy demands by coupling an urban physics model with a physics-based building energy model. Validation of the interactive coupling scheme uses field measurement datasets. Parametric simulation and analysis are conducted to understand the influence of the roof-to-canyon width ratio, canyon orientation, and ground vegetation fraction on canyon temperature, building energy consumption, and energy demand. Furthermore, the impacts of building energy model complexity (e.g., detailed vs. simplified building models) and coupling approaches on canyon temperature and building energy profiles are demonstrated using two case study buildings. In comparison with the one-way coupling approach, cooling energy consumption predicted with the dynamic two-way coupling approach varies by 3.5% and 0.5% for the detailed medium office building model and high-rise building model, respectively, and peak cooling demand varies by 8.4% and 7.0% for the detailed medium office building model and high-rise building model, respectively. Here this study also suggests that adopting a complex two-way coupling approach with environmental data exchange at various elevations is necessary for modeling tall buildings at the urban scale.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Time and Frequency Analysis of Load Profile Data

Technology advancements and integration of modern advanced metering systems can monitor, forecast, inform, control, and operate the building's mechanical, electrical, and plumbing (MEP) systems. They offer a higher level of information, which can contribute to making smart buildings more energy efficient and to making them closer to becoming grid-interactive energy efficient buildings (GEB). This paper builds on the ongoing research on variability analysis of a case study building with a 1-minute load profile and examines the Discrete Wavelet Transform (DWT) process in the frequency domain to quantify the signal's energy in each bandwidth, with respect to each end-use category. Moreover, the amount of variability in the total variability is not similar among the end-use categories. This information is needed to understand the behavior of the variability in the frequency domain for future applications, such as generating synthetic load profiles with a similar frequency spectrum as the measured signal.

decomposition↗

The Cost-Effectiveness of Investments to Meet the Guiding Principles for High-Performance Sustainable Buildings on the PNNL Campus

As part its campus sustainability efforts, Pacific Northwest National Laboratory (PNNL) has invested in eight new and existing buildings to ensure they meet the U.S. Department of Energy’s requirements for high performance sustainable buildings (HPSB) at DOE sites. These investments are expected to benefit PNNL by reducing the total life-cycle cost of facilities, improving energy efficiency and water conservation, and making buildings safer and healthier for the occupants. This study examines the cost-effectiveness of the implementing measures that meet the criteria for HPSBs in 3 different types of buildings on the PNNL campus: offices, scientific laboratories, and data centers. In each of the three case studies examined the investments made to achieve HPSB status demonstrated a high return on the HPSB investments that have taken place in these varied environments. Simple paybacks for total investments in the three case study buildings ranged from just 2 to 5 years; savings-to-investment ratios all exceeded the desirable threshold of 1; and the net present values associated with these investments were all positive.

BUILDINGS↗

Building envelope anomaly characterization and simulation using drone time-lapse thermography

Defects in building envelopes deteriorate over time without being visible to the human eye, while significantly impacting energy performance due to unaccounted heat transfer. Defects can be characterized in the infrared (IR) spectrum. However, IR readings are typically recorded at singular points in time, when in several cases anomalies can only be revealed at specific times of the day, possibly in different seasons of the year. This paper presents a novel workflow for 3D envelope defect characterization and modeling using aerial time-lapse IR data collection using drones. A comprehensive envelope thermal profile is developed for a case study building employing the photogrammetry software Agisoft Photoscan, which generates temporal IR inspections of building skins using multiple thermography orthomosaics. Point-cloud data is then translated into a CAD model and thermal zones for whole Building Energy Modeling (BEM) using Honeybee as a frontend to EnergyPlus to showcase the potential of inclusion of detailed 4D data. Envelope contributions in this case study’s anomalies showed heat losses of 6447.6 kWh, and Energy Use Intensity (EUI) differences of ~2 kWh/m 2 /year from the baseline. Finally, why there is currently little translation of this work in BEM software is discussed, while identifying limitations and future research in the employment of time-lapse thermography using drones for more accurate building envelope inspection and modeling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Machine learning-enhanced MPC for demand flexibility in small commercial buildings: An experimental study

Small- and medium-sized commercial buildings (SMCBs) represent the majority of U.S. commercial building stock and a significant share of peak electricity demand, yet they often lack centralized building automation systems, representing a significant untapped resource for urban energy management. This infrastructure gap makes advanced control implementation challenging, limiting the potential for widespread demand flexibility. Model Predictive Control (MPC) has shown strong potential for load shifting, peak demand reduction, and cost savings, but its effectiveness is hindered by unmeasured disturbances such as internal heat gains. This paper presents a Hybrid MPC framework that integrates a physics-based gray-box building thermal model, identified using a lumped disturbance (LD) approach, with a machine learning (ML) model for forecasting unmeasured disturbances. The hybrid approach is designed for buildings with multiple individually controlled heat pump and thermostat pairs, common in SMCBs, and aims to optimize coordinated scheduling of multiple heat pumps under dynamic electricity pricing while respecting comfort constraints. The methodology is validated through both simulations of case study buildings and experimental studies at a highly-instrumented test facility. Simulation results show that the Hybrid MPC achieves substantial load shifting and peak demand reduction, approaching the performance of an ideal MPC with perfect disturbance knowledge, and outperforming a conventional MPC without disturbance forecasting. In experiments, the Hybrid MPC reduced daily HVAC energy costs by 8.7%, peak-price time load (load shifting) by 41.7%, and peak demand by 29.2% compared to baseline control, demonstrating comparable benefits to the 11.6% cost savings, 42.9% load shifting, and 23.2% peak reduction of the ideal MPC. These results demonstrate that the proposed hybrid modeling approach can significantly improve MPC performance in real-world SMCB applications without requiring additional disturbance measurements.

Demand Flexibility↗