Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “builders”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Assessing Foundation Insulation Strategies for the 2012 International Energy Conservation Code in Cold Climate New Home Construction

Even though the International Energy Conservation Code 2012 (International Code Council 2012) is a model code now available for adoption by individual states, only two cold-climate states have adopted it as their new home energy code. Understanding the resistance to adoption is important in assisting more states to accept the code and engage in deep energy strategies nationwide. This three-part assessment by the NorthernSTAR Building America Partnership was focused on foundation insulation R-values for cold climates and the design, construction, and performance implications. In Section 1, a literature review and attendance at stakeholder meetings held in Minnesota were used to assess general stakeholder interest and concerns about proposed code changes. Section 2 includes drawings of robust foundation insulation systems that were presented at one Minnesota stakeholder meeting to address critical issues and concerns for adopting best practice strategies. In Section 3, a sampling of builders participated in a telephone interview to gain baseline knowledge on insulation systems used to meet the current energy code and how the same builders intend to meet the new proposed code. In general, most builders expressed interest in being able to deliver greater energy efficiency to their customers. Concerns were voiced, however, about the costs compared to the energy savings, constructability, and durability risk resulting from increased foundation insulation R-values. When solutions for building robust foundation wall systems were presented to stakeholders, they did express interest in learning the details of the strategies. There was, however, continued interest in proof of cost, payback, and hygrothermal performance. Builders who participated in the interview were more confident in being able to meet the new requirements. This might have been a result of these respondents already using more advanced techniques for foundation insulation. This insight gives Building America an opportunity to engage the industry with existing research and practice measures that can address constructability and durability concerns at the proposed code levels. It also indicates that builders are interested in more specific information on cost, energy savings, and overall hygrothermal performance. Filling these voids could yield the supportive data needed to enhance building industry confidence and engage more states in the adoption of 2012 International Energy Conservation Code for new homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Business Metrics for High-Performance Homes: A Colorado Springs Case Study

The building industry needs to understand how energy ratings can impact homebuilders. Of interest is how energy efficiency may or may not have a positive impact on homebuilders’ business success. Focusing on Colorado Springs, Colorado, as a case study, the U.S. Department of Energy’s Building America research team IBACOS suggests a win–win between a builder’s investment in energy efficiency and that builder’s ability to sell homes. Although this research did not ultimately determine why a correlation may exist, a builder’s investment in voluntary energy-efficiency programs correlated with that builder’s ability to survive the Great Recession of 2007 to 2009. This report explores the relationship between energy-efficiency ratings and the market performance of several builders in Colorado Springs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Starting with Solar: A Preliminary Assessment of Solar Energy Systems in Residential New Construction [Slides]

New homes provide a ready option for states hoping to reduce energy use, as evidenced by the steady increase in energy efficiency requirements in new home building codes. A less common approach is to specifically encourage or require new homes to produce their own carbon-free energy, through the installation of a solar energy system. Adopting these practices nationwide might significantly reduce new home energy use, but the drivers of the new solar home market have not been well studied. Partly filling this gap, this report looks at historical deployment trends of solar on over 500,000 new homes built through 2020 across 19 states and the District of Columbia, most of which were in California. California is a useful test case because if first incentivized in 2007, and more recently required in 2018, new homes to have solar. The report finds that solar adoption rates at roughly 40% in recent years in California eclipse—by a wide margin—rates in other states, which top out near 4%. The presence of California’s New Solar Home Partnership (NSHP) incentives appear strongly correlated with deployment levels, as do builder market share. The Top-10 builders in California installed solar in recent years at rates almost three times the average of non-Top-10 builders in the state. Interestingly, the authors found the same large builders did not install solar at the same elevated rates outside California, which might be related to the lack of incentives, they hypothesize. The report also investigates the characteristics of new solar homes such as living area (i.e., square feet), solar system size, frequency of battery installations, and use of third-party ownership. The authors also include quotes directly from builders to provide context to the findings.

14 SOLAR ENERGY↗

Zero Energy Ready Out of the Box

In this conference paper for the ASHRAE Buildings XV conference, December 2022, PNNL staff share key metrics for companies who are combining off site construction with certification to the U.S. Department of Energy’s Zero Energy Ready Home program to create homes that are both cost effective to construct and high performance to live in. Key performance metrics and measures for modular, panelized, and SIP homes are compared against all homes in the DOE Zero Energy Ready Home program and against new homes built to code. These metrics show that off-site construction homes got similar or better energy performance to site-built homes, and in the case of modular and panelized, at considerably lower average cost than site-built homes. The paper also highlights the experiences of two DOE Zero Energy Ready Home builders who employ offsite construction methods. One builder constructs production homes using pre-assembled panels. The other builder designs and ships kit homes all over the United States. The paper will focus on the optimum value engineering aspects of the panelized construction processes used by each builder to identify management and production practices employed by the builders to operate profitably while meeting high energy performance goals, despite a year marked by skyrocketing materials costs and supply chain and labor shortages. Cost and labor savings methods will be discussed in the context of these two unique business models.

U.S. Department of Energy Building Technologies Pr↗

New Whole-House Solutions Case Study: Winchester Homes and Camberly Homes

The Partnership for Home Innovation team worked with the builder to develop a new set of high performance home designs—including advanced wall and HVAC systems—that could be applicable on a production scale. The new home designs are to be constructed in the mixed humid climate zone and could eventually apply to all of the builder's home designs to meet or exceed future energy codes or performance-based programs. However, the builder recognized that the combination of new wall framing designs and materials, higher levels of insulation in the wall cavity, and more detailed air sealing to achieve lower infiltration rates changes the moisture characteristics of the wall system. In order to ensure long term durability and repeatable successful implementation with few call-backs, this report demonstrates through measured data that the wall system functions as a dynamic system, responding to changing interior and outdoor environmental conditions within recognized limits of the materials that make up the wall system. A similar investigation was made with respect to the complete redesign of the heating, cooling, air distribution, and ventilation systems intended to optimize the equipment size and configuration to significantly improve efficiency while maintaining indoor comfort. Recognizing the need to demonstrate the benefits of these efficiency features, the builder offered a new house model to serve as a test case to develop framing designs, evaluate material selections and installation requirements, changes to work scopes and contractor learning curves, as well as to compare theoretical performance characteristics with measured results.

2x6 walls↗

Final Project Report

This project pursued innovations to improve energy efficiency and indoor environmental quality (IEQ) in commercial and residential buildings. For commercial buildings, the project developed a testbed for “intelligent nested environmental systems technologies (iNEST),” which monitor and control energy flows and IEQ across a cascade of spaces from individuals’ desktops to office suites to floors to whole buildings. An iNEST testbed was constructed at Syracuse University and was used to assess the use of devices such as personal badges and CO2 sensors to study how reduced energy use and improved IEQ could be achieved. For residential buildings, resources were targeted in support of DoE’s Builders Challenge Program and to recruit Syracuse, NY builders. Three homes in Syracuse’s Near Westside neighborhood were also registered under the program by Syracuse University team, with an additional home registered by one of the builders. Findings from the work at the iNEST testbed facility, and results from other related projects were disseminated through Syracuse Center of Excellence in Environmental and Energy Systems (SyracuseCoE) 2008 Annual Symposium, the 9th International Healthy Buildings 2009 Conference & Exhibition, and through SyracuseCoE’s website and eNewsletters to inform the broader community of researchers, designers and builders. These public communication activities helped enhance the understanding of high performance buildings and facilitate further market acceptance.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

2011 EnergyValue Housing Award Report

The EnergyValue Housing Award (EVHA), an integral part of the U.S. Department of Energy’s Building America (BA) program, seeks to improve and expand the energy efficiency of residential construction nationwide by honoring builders and remodelers and awarding highly efficient homes. Receiving EVHA recognition helps builders and remodelers communicate the value of energy efficiency to prospective customers and distinguish their homes from those built by more traditional residential construction companies. It also provides opportunities for EVHA winning builders and remodelers to set an example for improving the quality and performance of homes throughout the country. Each year, the project scope of the EVHA includes the application and judging processes, developing the EVHA publication, updating the program and application for the next year, hosting the EVHA banquet, and outreach and technical support. Following the award banquet, the NAHB Research Center evaluates the energy performance of that year’s EVHA winning houses. This work is primarily comprised of estimating the energy savings of each home/ or housing unit over the BA Benchmark using energy simulation software and procedures developed by the BA program. The energy evaluations serve as a quantitative measure of the energy efficiency of the units which the judges decided merited an award. As part of this work, the NAHB Research Center Industry Partnership (NAHBRC-IP) for High Performing Homes strives to make new and existing homes more energy efficient, durable, and affordable through research and development as one of the U.S. Department of Energy’s BA teams. Each year, through the EVHA, builder and remodeler partners work with industry partners in a variety of climates endeavor to reach the energy efficiency targets of the BA program. (Department of Energy 2012) This report details the simulation tool(s) and energy modeling methodology followed in making the energy efficiency estimates and documents the estimated performance of the EVHA award winning houses in comparison with the BA Benchmark and the associated House Simulation Protocols (HSPs). A summary of each building and its features is included with a brief description of the project and the judges’ comments. The purpose of this report is to assess the energy performance of the 2011 EVHA winners and to align the EVHA program with the BA program.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-R Walls for New Construction Structural Performance: Integrated Rim Header Testing

The Building America Program takes two prominent approaches to construct higher R-value walls: larger dimension framing and exterior rigid foam insulation. These have had some success; however, for many production builders the cost of changing framing systems is high, so the changes have been slowly realized. Also, recent building code changes have raised some performance issues for exterior sheathing and raised heel trusses, for example, that indicates a need for continued performance testing of wall systems. Furthermore, some material use survey data have shown that often when builders are switching to 2 × 6 framing members, they commonly use of 16-in. o.c. spacing. The opportunity to (1) encourage the use of thicker framing systems for much higher R-value walls; (2) construct wall systems that optimize the framing use to reduce thermal breaks; and (3) extract opportunities to reduce costs, all remain high priorities for the Building America program, the NAHB Research Center Industry Partnership, and builders. Similarly for the use of exterior rigid sheathing, builders and researchers have investigated alternative bracing techniques to eliminate the use of wood structural sheathing in lieu of foam board sheathing. Structural characteristics, especially in the direction perpendicular to the sheathing, have been reevaluated for the building codes. These include pressure equalization issues across multiple layers of the wall system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance House -- A Cold Climate Challenge Home

Working with builder partners on a test homes allows for vetting of whole-house building strategies to eliminate any potential unintended consequences prior to implementing these solution packages on a production scale. To support this research, CARB partnered with Preferred Builders Inc. on a high-performance test home in Old Greenwich, CT. The philosophy and science behind the 2,700 ft2 'Performance House' was based on the premise that homes should be safe, healthy, comfortable, durable, efficient, and adapt with the homeowners. The technologies and strategies used in the 'Performance House' were not cutting-edge, but simply 'best practices practiced'. The focus was on simplicity in construction, maintenance, and operation. When seeking a 30% source energy savings targets over a comparable 2009 IECC code-built home in the cold climate zone, nearly all components of a home must be optimized. Careful planning and design are critical. To help builders and architects seeking to match the performance of this home, a step-by-step guide through the building shell components of DOE's Challenge Home are provided in a pictorial story book. The end result was a DOE Challenge Home that achieved a HERS Index Score of 20 (43 without PV, the minimum target was 55 for compliance). This home was also awarded the 2012 HOBI for Best Green Energy Efficient Home from the Home Builders & Remodelers Association of Connecticut.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Affordable Cold Climate Infill Housing with Hybrid Insulation Approach, Wyandotte, Michigan (Fact Sheet)

Even builders who are relatively new to energy-efficient construction can consistently reach a target whole house airtightness of 1.5 air changes per hour at 50 Pascals (ACH50) with high R-value enclosures that use a hybrid insulation approach. The City of Wyandotte, Michigan, started a construction program in 2010 to build affordable, energy-efficient homes on lots in existing neighborhoods. A goal of the program was to engage local builders in energy-efficient construction and be able to deliver the new houses for less than $100/ft2. By the end of 2012, approximately 25 new houses were built by five local builders under this program. To help builders consistently achieve the airtightness target, a local architect worked with researchers from Building Science Corporation, a U.S. Department of Energy Building America team, to develop a technology specification with several key pieces. A high R-value wall and roof assembly made use of 2 ?6 advanced framing and a hybrid insulation approach that included insulating sheathing to control thermal bridging and closed cell spray polyurethane foam insulation (ccSPF) for its airtightness and vapor control benefits. This approach allows the air barrier to be completed and tested before any finishing work occurs, ensuring that problems are spotted and corrected early in the construction process.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Performance House—A Cold Climate Challenge Home

Working with builder partners on test homes allows for vetting of whole-house building strategies to eliminate any potential unintended consequences prior to implementing these solution packages on a production scale. To support this research, CARB partnered with Preferred Builders Inc. on a high-performance test home in Old Greenwich, CT. The philosophy and science behind the 2,700 ft 2 "Performance House" was based on the premise that homes should be safe, healthy, comfortable, durable, efficient, and adapt with the homeowners. The technologies and strategies used in the "Performance House" were not cutting-edge, but simply "best practices practiced". The focus was on simplicity in construction, maintenance, and operation. When seeking a 30% source energy savings targets over a comparable 2009 IECC code-built home in the cold climate zone, nearly all components of a home must be optimized. Careful planning and design are critical. To help builders and architects seeking to match the performance of this home, a step-by-step guide through the building shell components of DOE's Challenge Home are provided in a pictorial story book. The end result was a DOE Challenge Home that achieved a HERS Index Score of 20 (43 without PV, the minimum target was 55 for compliance). This home was also awarded the 2012 HOBI for Best Green Energy Efficient Home from the Home Builders & Remodelers Association of Connecticut.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High Performance Walls in Hot-Dry Climates

High performance walls represent a high priority measure for moving the next generation of new homes to the Zero Net Energy performance level. The primary goal in improving wall thermal performance revolves around increasing the wall framing from 2x4 to 2x6, adding more cavity and exterior rigid insulation, achieving insulation installation criteria meeting ENERGY STAR's thermal bypass checklist. To support this activity, in 2013 the Pacific Gas & Electric Company initiated a project with Davis Energy Group (lead for the Building America team, Alliance for Residential Building Innovation) to solicit builder involvement in California to participate in field demonstrations of high performance wall systems. Builders were given incentives and design support in exchange for providing site access for construction observation, cost information, and builder survey feedback. Information from the project was designed to feed into the 2016 Title 24 process, but also to serve as an initial mechanism to engage builders in more high performance construction strategies. This Building America project utilized information collected in the California project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Achieving Challenge Home in Affordable Housing in the Hot - Humid Climate

The Building America Partnership for Improved Residential Construction (BA-PIRC), one of the Building America research team leads, has partnered with two builders as they work through the Challenge Home certification process in one test home each. The builder partners participating in this cost-shared research are Southeast Volusia County Habitat for Humanity near Daytona, Florida and Manatee County Habitat for Humanity near Tampa, Florida. Both are affiliates of Habitat for Humanity International, a non-profit affordable housing organization. This research serves to identify viable technical pathways to meeting the CH criteria for other builders in the region. A further objective of this research is to identify gaps and barriers in the marketplace related to product availability, labor force capability, code issues, cost effectiveness, and business case issues that hinder or prevent broader adoption on a production scale. The builder partners participating in this cost-shared research are Southeast Volusia County Habitat for Humanity (SEVHFH) near Daytona, Florida and Manatee County Habitat for Humanity (MCHFH) near Tampa, Florida. Both are affiliates of Habitat for Humanity International (HFHI), a nonprofit affordable housing organization. Manatee Co Habitat for Humanity Challenge home - Ellenton, FL 34222 S. Sarasota Challenge Home - Sarasota, FL Southeast Volusia co Habitat for Humanity's Challenge Home - Edgewater, FL 32141 Several iterations of home, Challenge Home as built, Challenge Home without solar, and Challenge Home configured to just meet Florida Code. All houses redone in BEOpt 2.1.0.2

affordable housing↗

Building America Case Study: High Performance Ducts in Hot-Dry Climates; Technology Solutions for New and Existing Homes, Energy Efficiency & Renewable Energy (EERE)

?Ducts in conditioned space (DCS) represent a high priority measure for moving the next generation of new homes to the Zero Net Energy performance level. Various strategies exist for incorporating ducts within the conditioned thermal envelope. To support this activity, in 2013 the Pacific Gas & Electric Company initiated a project with Davis Energy Group (lead for the Building America team, Alliance for Residential Building Innovation) to solicit builder involvement in California to participate in field demonstrations of various DCS strategies. Builders were given incentives and design support in exchange for providing site access for construction observation, diagnostic testing, and builder survey feedback. Information from the project was designed to feed into California's 2016 Title 24 process, but also to serve as an initial mechanism to engage builders in more high performance construction strategies. This Building America project complemented information collected in the California project with BEopt simulations of DCS performance in hot/dry climate regions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technology Solutions Case Study: High-Performance Ducts in Hot-Dry Climates

Ducts in conditioned space (DCS) represent a high priority measure for moving the next generation of new homes to the Zero Net Energy performance level. Various strategies exist for incorporating ducts within the conditioned thermal envelope. To support this activity, in 2013 the Pacific Gas & Electric Company initiated a project with Davis Energy Group (lead for the Building America team, Alliance for Residential Building Innovation) to solicit builder involvement in California to participate in field demonstrations of various DCS strategies. Builders were given incentives and design support in exchange for providing site access for construction observation, diagnostic testing, and builder survey feedback. Information from the project was designed to feed into California's 2016 Title 24 process, but also to serve as an initial mechanism to engage builders in more high performance construction strategies. This Building America project complemented information collected in the California project with BEopt simulations of DCS performance in hot/dry climate regions.

ARBI↗

DOE Zero Energy Ready Home Case Study: KB Homes, San Marcos, California

Designed to produce as much energy as it uses, the ZeroHouse incorporates a PV system, R-15 fiberglass batts in walls, and slab-on-grade foundation. The builder ranked fifth in the nation on Builder Magazine’s 2012 Top 100 ranking of U.S. home builders based on number of housing starts, and won a 2013 Housing Innovation Award in the production builder category.

Building America↗

DOE Zero Energy Ready Home Case Study: Mandalay Homes, Phoenix, Arizona

This builder built fourteen homes in the Gordon Estates subdivision that achieved Challenge Home certification with HERS 38–58 on an affordable budget for homeowners. Every Mandalay home in the development also met the National Green Building Standard gold level. The Gordon Estates subdivision is also serving as a showcase of energy efficiency, and Mandalay is hosting education workshops for realtors, state and local officials, other builders, students, potential homeowners, and the public. The builder won a 2013 Housing Innovation Award in the affordable builder category.

Building America↗

New Whole-House Solutions Case Study: Affordable Cold Climate Infill Housing with Hybrid Insulation Approach, Wyandotte, Michigan

Even builders who are relatively new to energy-efficient construction can consistently reach a target whole house airtightness of 1.5 air changes per hour at 50 Pascals (ACH50) with high R-value enclosures that use a hybrid insulation approach. In 2010, the City of Wyandotte, Michigan, started construction to build affordable, energy-efficient homes on lots in existing neighborhoods. A goal was to engage local builders in energy-efficient construction and be able to deliver the new houses for less than $100/ft2. By the end of 2012, approximately 25 new houses were built by five local builders under this program. To help builders consistently achieve the airtightness target, a local architect worked with researchers from Building Science Corporation, a Building America team, to develop a technology specification with several key pieces. A high R-value wall and roof assembly made use of 2 ×6 advanced framing and a hybrid insulation approach that included insulating sheathing to control thermal bridging and closed cell spray polyurethane foam insulation (ccSPF) for its airtightness and vapor control benefits. This approach allows the air barrier to be completed and tested before any finishing work occurs, ensuring that problems are spotted and corrected early in the construction process.

BSC↗