Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “bolometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

5,120 Superconducting Bolometers for the PIPER Balloon-Borne CMB Polarization Experiment

We are constructing the Primordial Inflation Polarization Explorer (PIPER) to measure the polarization o[ the cosmic microwave background (CMB) and search for the imprint of gravity waves produced during an inflationary epoch in the early universe. The signal is faint and lies behind confusing foregrounds, both astrophysical and cosmological, and so many detectors are required to complete the measurement in a limited time. We will use four of our matured 1,280 pixel, high-filling-factor backshort-under-grid bolometer arrays for efficient operation at the PIPER CMB wavelengths. All four arrays observe at a common wavelength set by passband filters in the optical path. PIPER will fly four times to observe at wavelengths of 1500, 1100, 850, and 500 microns in order to separate CMB from foreground emission. The arrays employ leg-isolated superconducting transition edge sensor bolometers operated at 128mK; tuned resonant backshorts for efficient optical coupling; and a second-generation superconducting quantum interference device (SQUID) multiplexer readout. We describe the design, development, and performance of PIPER bo|ometer array technology to achieve background-limited sensitivity for a cryogenic balloon-borne telescope.

Benford, Dominic J.↗

AC Read-Out Circuits for Single Pixel Characterization of TES Microcalorimeters and Bolometers

SRON is developing Frequency Domain Multiplexing (FDM) for the read-out of transition edge sensor (TES) soft x-ray microcalorimeters for the XMS instrument of the International X-ray Observatory and far-infrared bolometers for the SAFARI instrument on the Japanese mission SPICA. In FDM the TESs are AC voltage biased at frequencies from 0.5 to 6 MHz in a superconducting LC resonant circuit and the signal is read-out by low noise and high dynamic range SQUIDs amplifiers. The TES works as an amplitude modulator. We report on several AC bias experiments performed on different detectors. In particular, we discuss the results on the characterization of Goddard Space Flight Center x-ray pixels and SRON bolometers. The paper focuses on the analysis of different read-out configurations developed to optimize the noise and the impedance matching between the detectors and the SQUID amplifier. A novel feedback network electronics has been developed to keep the SQUID in flux locked loop, when coupled to superconducting high Q circuits, and to optimally tune the resonant bias circuit. The achieved detector performances are discussed in view of the instrument requirement for the two space missions.

Gottardi, L.↗

MgB2 Thin-Film Bolometer for Applications in Far-Infrared Instruments on Future Planetary Missions

A SiN membrane based MgB2 thin-film bolometer, with a non-optimized absorber, has been fabricated that shows an electrical noise equivalent power of 256 fW/square root Hz operating at 30 Hz in the 8.5 - 12.35 micron spectral bandpass. This value corresponds to an electrical specific detectivity of 7.6 x 10(exp 10) cm square root Hz/W. The bolometer shows a measured blackbody (optical) specific detectivity of 8.8 x 10(exp 9) cm square root Hz/W, with a responsivity of 701.5 kV/W and a first-order time constant of 5.2 ms. It is predicted that with the inclusion of a gold black absorber that a blackbody specific detectivity of 6.4 x 10(exp 10) cm/square root Hz/W at an operational frequency of 10 Hz, can be realized for integration into future planetary exploration instrumentation where high sensitivity is required in the 17 - 250 micron spectral wavelength range.

Lakew, B.↗

MgB2-Based Bolometer Array for Far Infra-Red Thermal Imaging and Fourier Transform Spectroscopy Applications

The mid-superconducting critical temperature (T(sub c) approximately 39 K) of the simple binary, intermetallic MgB, [1] makes it a very good candidate for the development of the next generation of electrooptical devices (e.g. [2]). In particular, recent advances in thin film deposition teclmiques to attain higb quality polycrystalline thin film MgB, deposited on SiN-Si substrates, with T(sub c) approximately 38K [3] coupled with the low voltage noise performance of the film [4] makes it higbly desirable for the development of moderately cooled bolometer arrays for integration into future space-bourne far infra-red (FIR) spectrometers and thermal mappers for studying the outer planets, their icy moons and other moons of interest in the 17-250 micrometer spectral wavelength range. Presently, commercially available pyroelectric detectors operating at 300 K have specific detectivity, D(*), around 7 x 10(exp 8) to 2 x 10(exp 9) centimeters square root of Hz/W. However, a MgB2 thin film based bolometer using a low-stress (less than 140 MPa) SiN membrane isolated from the substrate by a small thermal conductive link, operating at 38 K, promises to have two orders of magnitude higher specific detectivity [5][6].

Lakew, B.↗

Characterization of Doped Silicon Thermometers for Very High Sensitivity Cryogenic Bolometers

Understanding the origin and early evolution of stars is one of the fundamental objectives of astronomy. This can be possible with observations made from space in the mid- to far-infrared and millimeter-wave part of the spectrum which require detectors with very high sensitivity. In the framework of the SPICA project and the course of developing cooled semiconductor bolometers for sub-millimeter-wave detection, typically 100 μm ≤ λ ≤ 1.5 mm, we have investigated several thermometers based on doped silicon Si:P,B. We observed an important dependence of the Si:P,B resistance to the doping densities and found potential thermometers for cryogenic detections at very low temperatures (50 mK < T < 100 mK). In addition, numerical simulations allowed us to study the thermoelectrical behavior of the potential detectors and predict a clear enhancement of the detector performances.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

BRAHMS-Sensitive Bolometer Arrays for the SPICA Imaging Polarimetry

A high-sensitivity cryogenic sub-millimetre camera is planned for the SPICA space observatory. At the heart of this instrument, new all-silicon bolometer arrays integrate in pixel instrumental polarimetry capabilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Josephson Effects in Frequency-Domain Multiplexed TES Microcalorimeters and Bolometers

Frequency-division multiplexing is the baseline read-out system for large arrays of superconducting transition-edge sensors (TES’s) under development for the X-ray and infrared instruments like X-IFU (Athena) and SAFARI, respectively. In this multiplexing scheme, the sensors are ac-biased at different frequencies from 1 to 5 MHz and operate as amplitude modulators. Weak superconductivity is responsible for the complex TES resistive transition, experimentally explored in great detail so far, both with dc- and ac-biased read-out schemes. In this paper, we will review the current status of our understanding of the physics of the TES’s and their interaction with the ac bias circuit. In particular, we will compare the behaviour of the TES nonlinear impedance, across the superconducting transition, for several detector families, namely: high-normal-resistance TiAu TES bolometers, low-normal-resistance MoAu TES microcalorimeters and high-normal-resistance TiAu TES microcalorimeters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electromagnetic Simulations of Newly Designed Semiconductor Bolometers for Submillimeter Observations

In the frame of the SPICA mission, new semiconductor bolometers have been designed for the POL instrument which is directly part of the HERSCHEL/PACS legacy. These detectors are cooled down to 50 mK and are sensitive to polarization for the 100, 200 and 350 μm wavelength bands. In this paper, 3D simulations have been carried out with the COMSOL Multiphysics software to design the two suspended interlaced silicon spirals which support the orthogonal absorbers (sensitive to the two polarizations) of the POL detectors. These simulations allow to optimize the design of the absorbers and to quantify the cross-polarization. In the last part of this paper, we explain how it is possible to reach the 200 and 350 μm bands from the layout of the 100-μm detector.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optical Characterization of OMT-Coupled TES Bolometers for LiteBIRD

Feedhorn- and orthomode transducer- (OMT) coupled transition edge sensor (TES) bolometers have been designed and micro-fabricated to meet the optical specifications of the LiteBIRD high frequency telescope (HFT) focal plane. Here, we discuss the design and optical characterization of two LiteBIRD HFT detector types: dual-polarization, dual-frequency-band pixels with 195/280 GHz and 235/337 GHz band centers. Results show well-matched passbands between orthogonal polarization channels and frequency centers within 3% of the design values. The optical efficiency of each frequency channel is conservatively reported to be within the range 0.64–0.72, determined from the response to a cryogenic, temperature-controlled thermal source. These values are in good agreement with expectations and either exceed or are within 10% of the values used in the LiteBIRD sensitivity forecast. Lastly, we report a measurement of loss in Nb/SiN x /Nb microstrip at 100 mK and over the frequency range 200–350 GHz, which is comparable to values previously reported in the literature.

47 OTHER INSTRUMENTATION↗

Neutron spectroscopy with {sup 6}LiF bolometers

A compact and semi-portable neutron detector has been built based on the bolometric technique. Its unique features open new possibilities for the radioprotection survey of fast neutrons at nuclear installations and the investigations of background problems of sensitive neutron scattering instruments. This cryogenic detector, operated at 300-400 mK, consists of a 0.5 g LiF 95%{sup 6}Li enriched crystal read out by a NTD-Ge sensor and is based on the {sup 6}Li(n, {alpha}){sup 3}H neutron capture reaction. It is used to define the energy of neutrons up to 5 MeV. Measurements with {sup 252}Cf source have been performed to determine the energy resolution of the detector. We report the first results obtained with this neutron detector. From developments made in view of the ROSEBUD (Rare Objects SEarch with Bolometers UndergrounD) collaboration we suggest a possible further improvement of the neutron detector by employing a combined heat and light detection. In the case of dark matter experiments, such a detector would allow to monitor the residual fast neutron component.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved calibration technique of the infrared imaging bolometer using ultraviolet light-emitting diodes

The technique used until recently utilizing the Ne-He laser for imaging bolometer foils calibration [B. J. Peterson et al., J. Plasma Fusion Res. 2, S1018 (2007)] has showed several issues. The method was based on irradiation of 1 cm spaced set of points on a foil by the laser beam moved by set of mirrors. Issues were the nonuniformity of laser power due to the vacuum window transmission nonuniformity and high reflection coefficient for the laser. Also, due to the limited infrared (IR) window size, it was very time consuming. The new methodology uses a compact ultraviolet (uv) light-emitting diodes installed inside the vacuum chamber in a fixed position and the foil itself will be moved in the XY directions by two vacuum feedthroughs. These will help to avoid the above mentioned issues due to lack of a vacuum window, fixed emitters, higher uv power absorption, and a fixed IR camera position.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A photodiode-based neutral particle bolometer for characterizing charge-exchanged fast-ion behavior

A neutral particle bolometer (NPB) has been designed and implemented on Tri Alpha Energy's C-2 device in order to spatially and temporally resolve the charge-exchange losses of fast-ion populations originating from neutral beam injection into field-reversed configuration plasmas. This instrument employs a silicon photodiode as the detection device with an integrated tungsten filter coating to reduce sensitivity to light radiation. Here we discuss the technical aspects and calibration of the NPB, and report typical NPB measurement results of wall recycling effects on fast-ion losses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pyroelectric response mechanism of barium strontium titanate ceramics in dielectric bolometer mode: The underlying essence of the enhancing effect of direct current bias field

Pyroelectric response mechanism of Ba{sub 0.70}Sr{sub 0.30}TiO{sub 3} ceramics under dielectric bolometer (DB) mode was investigated by dielectric and pyroelectric properties measurement. The variations of total, intrinsic, and induced pyroelectric coefficients (p{sub tot}, p{sub int}, p{sub ind}) with temperatures and bias fields were analyzed. p{sub int} plays the dominant role to p{sub tot} through most of the temperature range and p{sub ind} will be slightly higher than p{sub int} above T{sub 0}. The essence of the enhancing effect of DC bias field on pyroelectric coefficient can be attributed to the high value of p{sub int}. This mechanism is useful for the pyroelectric materials (DB mode) applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Superconducting cuprate heterostructures for hot electron bolometers

Transport properties of the resistive state of quasi-two dimensional superconducting heterostructures containing ultrathin La{sub 2−x}Sr{sub x}CuO{sub 4} layers synthesized using molecular beam epitaxy are studied. The electron transport exhibits strong deviation from Ohm's law, δV∼γI{sup 3}, with a coefficient γ(T) that correlates with the temperature variation of the resistivity dρ/dT. Close to the normal state, analysis of the nonlinear behavior in terms of electron heating yields an electron-phonon thermal conductance per unit area g{sub e−ph}≈1 W/K cm{sup 2} at T = 20 K, one-two orders of magnitude smaller than in typical superconductors. This makes superconducting LaSrCuO heterostructures to be attractive candidate for the next generation of hot electron bolometers with greatly improved sensitivity.

36 MATERIALS SCIENCE↗

Non-uniform absorption of terahertz radiation on superconducting hot electron bolometer microbridges

We interpret the experimental observation of a frequency-dependence of superconducting hot electron bolometer (HEB) mixers by taking into account the non-uniform absorption of the terahertz radiation on the superconducting HEB microbridge. The radiation absorption is assumed to be proportional to the local surface resistance of the HEB microbridge, which is computed using the Mattis-Bardeen theory. With this assumption the dc and mixing characteristics of a superconducting niobium-nitride (NbN) HEB device have been modeled at frequencies below and above the equilibrium gap frequency of the NbN film.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Calibration of a thin metal foil for infrared imaging video bolometer to estimate the spatial variation of thermal diffusivity using a photo-thermal technique

A thin metal foil is used as a broad band radiation absorber for the InfraRed imaging Video Bolometer (IRVB), which is a vital diagnostic for studying three-dimensional radiation structures from high temperature plasmas in the Large Helical Device. The two-dimensional (2D) heat diffusion equation of the foil needs to be solved numerically to estimate the radiation falling on the foil through a pinhole geometry. The thermal, physical, and optical properties of the metal foil are among the inputs to the code besides the spatiotemporal variation of temperature, for reliable estimation of the exhaust power from the plasma illuminating the foil. The foil being very thin and of considerable size, non-uniformities in these properties need to be determined by suitable calibration procedures. The graphite spray used for increasing the surface emissivity also contributes to a change in the thermal properties. This paper discusses the application of the thermographic technique for determining the spatial variation of the effective in-plane thermal diffusivity of the thin metal foil and graphite composite. The paper also discusses the advantages of this technique in the light of limitations and drawbacks presented by other calibration techniques being practiced currently. The technique is initially applied to a material of known thickness and thermal properties for validation and finally to thin foils of gold and platinum both with two different thicknesses. It is observed that the effect of the graphite layer on the estimation of the thermal diffusivity becomes more pronounced for thinner foils and the measured values are approximately 2.5–3 times lower than the literature values. It is also observed that the percentage reduction in thermal diffusivity due to the coating is lower for high thermal diffusivity materials such as gold. This fact may also explain, albeit partially, the higher sensitivity of the platinum foil as compared to gold.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗