Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “biosensors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

CRAGE-mediated insertion of fluorescent chromosomal markers for accurate and scalable measurement of co-culture dynamics in Escherichia coli

Monitoring population dynamics in co-culture is necessary in engineering microbial consortia involved in distributed metabolic processes or biosensing applications. However, it remains difficult to measure strain-specific growth dynamics in high-throughput formats. This is especially vexing in plate-based functional screens leveraging whole-cell biosensors to detect specific metabolic signals. Here, we develop an experimental high-throughput co-culture system to measure and model the relationship between fluorescence and cell abundance, combining chassis-independent recombinase-assisted genome engineering (CRAGE) and whole-cell biosensing with a PemrR-green fluorescent protein (GFP) monoaromatic reporter used in plate-based functional screening. CRAGE was used to construct Escherichia coli EPI300 strains constitutively expressing red fluorescent protein (RFP) and the relationship between RFP expression and optical density (OD600) was determined throughout the EPI300 growth cycle. A linear equation describing the increase of normalized RFP fluorescence during deceleration phase was derived and used to predict biosensor strain dynamics in co-culture. Measured and predicted values were compared using flow cytometric detection methods. Induction of the biosensor lead to increased GFP fluorescence normalized to biosensor cell abundance, as expected, but a significant decrease in relative abundance of the biosensor strain in co-culture and a decrease in bulk GFP fluorescence. Taken together, these results highlight sensitivity of population dynamics to variations in metabolic activity in co-culture and the potential effect of these dynamics on the performance of functional screens in plate-based formats. The engineered strains and model used to evaluate these dynamics provide a framework for optimizing growth of synthetic co-cultures used in screening, testing and pathway engineering applications.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluation of phenolic antioxidant capacity in beverages based on laccase immobilized on screen-printed carbon electrode modified with graphene nanoplatelets and gold nanoparticles

A simple and highly sensitive electrochemical biosensor based on laccase immobilized onto a gold nanoparticles/graphene nanoplatelets-modified screen-printed carbon electrode (LACC/AuNP/GNPl/SPCE) was developed for the determination of hydroquinone (HQ) and other phenolic compounds. The biosensor shows excellent electro-catalytic activity towards oxidation of hydroquinone at a potential of -0.05 V (vs Ag/AgCl, 3 M KCl) in phosphate buffer as supporting electrolyte (0.1 M, pH 7.0) using hydrodynamic amperometry. Analytical characteristics uncover that the LACC/AuNP/GNPl/SPCE comprises a wide linear range for the dependence of the signal on HQ concentrations from 4 to 130 µM with a detection limit (3σ) of 1.5 µM. The repeatability (5 measurements, 100 µM hydroquinone) is ±2% and the reproducibility (5 biosensors, 100 µM hydroquinone) is ±3%. Interference studies of most common compounds with the determination of hydroquinone demonstrated negligible effects. Finally, the biosensor and the analytical method were applied to the determination of phenolic antioxidant capacity (AOC) in wine and blueberry syrup based on Trolox (6‑hydroxy‑2,5,7,8-tetramethylchromane-2-carboxylic acid) and hydroquinone equivalents. The results were evaluated by using their calibration curves which were satisfactory and agreed well with the results obtained by the reference method Trolox Equivalent Antioxidant Capacity assay (TEAC-Assay).

60 APPLIED LIFE SCIENCES↗

Brain-implantable multifunctional probe for simultaneous detection of glutamate and GABA neurotransmitters

We report Glutamate (GLU) and gamma-aminobutyric acid (GABA) are neurotransmitters (NTs) with an essential role in signal transmission in the brain. Brain disorders, such as epilepsy, Alzheimer's and Parkinson's diseases, and traumatic brain injury can be linked to imbalances in the GLU-GABA homeostasis that occurs in sub-second to seconds time frames. Current measurement techniques can detect these two NT concentrations simultaneously only in vitro. The present work reports on the fabrication of a silicon multifunctional biosensor microarray probe for sub-second simultaneous GLU-GABA detection in real-time, with excellent analyte sensitivity and selectivity and in vivo capabilities. The novel Si probes feature four surface-functionalized platinum ultramicroelectrodes (UMEs) for simultaneous amperometric detection of GLU and GABA with a sentinel, and a built-in microfluidic channel for the introduction of neurochemicals in the proximity of the UMEs. The microchannel also allows functioning of an On-Demand In-situ Calibrator that runs in-situ biosensor calibration. The probe exhibited excellent robustness at insertion in agarose-gel brain-tissue-mimicking test, and remarkably high hydrogen peroxide sensitivity (a by-product of GLU-GABA enzyme biosensor) with values on the order of 5000 nA μM -1 cm -2 and maximum sensitivities of 204 ± 15 nA μM -1 cm -2 and 37 ± 7 nA μM -1 cm -2 for GLU and GABA, respectively. Furthermore, the limit of detection of the biosensors reached as low as 7 nM, 165 nM and 750 nM for H 2 O 2 , GLU and GABA, respectively and a temporal resolution of hundreds of milliseconds during in vivo studies using freely moving rats.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detection of a multi–disease biomarker in saliva with graphene field effect transistors

Human carbonic anhydrase 1 (CA1) has been suggested as a biomarker for identification of several diseases including cancers, pancreatitis, diabetes, and Sjogren’s syndrome. However, the lack of a rapid, cheap, accurate, and easy-to-use quantification technique has prevented widespread utilization of CA1 for practical clinical applications. To this end, we present a label-free electronic biosensor for detection of CA1 utilizing highly sensitive graphene field effect transistors (G-FETs) as a transducer and specific RNA aptamers as a probe. The binding of CA1 with aptamers resulted in a positive shift in Dirac voltage V D of the G-FETs, the magnitude of which depended on target concentration. These aptameric G-FET biosensors showed the binding affinity (K D ) of ~2.3 ng/ml (70 pM), which is four orders lower than that reported using a gel shift assay. This lower value of K D enabled us to achieve a detection range (10 pg/ml - 100 ng/ml) which is well in line with the clinically relevant range. These highly sensitive devices allowed us to further prove their clinical relevance by successfully detecting the presence of CA1 in human saliva samples. In conclusion, the utilization of this label-free biosensor could facilitate the early stage identification of various diseases associated with changes in concentration of CAs.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Fundamentals of bio-electrochemical sensing

The utilization of bio-functionalities such as biorecognition or catalysis derived them their name biosensors. Bio-electrochemical sensing is a new discipline that combines the advantages of biological detection and electrochemical transduction. Bio-electrochemical sensors are devices that use biological materials such as enzymes, antibodies, DNA, or cells as receptors to detect target analytes in a variety of samples. Electrodes convert biological interactions into electrical impulses, which can be studied using various electrochemical techniques. Bio-electrochemical sensors have demonstrated significant promise for use in clinical diagnostics, environmental monitoring, food safety, and biotechnology. Biosensors have received numerous applications in recent years because they are fast, simple, and inexpensive for practical applications. In this article, we cover the basic principles, design strategies, immobilization and regeneration techniques, along with the advantages and applications of bio-electrochemical sensors. Finally, this article discusses the rationale for developing electrochemical biosensors in the context of the various bio-receptors that can be applied.

36 MATERIALS SCIENCE↗

Identification and demonstration of roGFP2 as an environmental sensor for cryogenic correlative light and electron microscopy

Cryogenic correlative light and electron microscopy (cryo-CLEM) seeks to leverage orthogonal information present in two powerful imaging modalities. While recent advances in cryogenic electron microscopy (cryo-EM) allow for the visualization and identification of structures within cells at the nanometer scale, information regarding the cellular environment, such as pH, membrane potential, ionic strength, etc., which influences the observed structures remains absent. Fluorescence microscopy can potentially be used to reveal this information when specific labels, known as fluorescent biosensors, are used, but there has been minimal use of such biosensors in cryo-CLEM to date. Here we demonstrate the applicability of one such biosensor, the fluorescent protein roGFP2, for cryo-CLEM experiments. At room temperature, the ratio of roGFP2 emission brightness when excited at 425 nm or 488 nm is known to report on the local redox potential. When samples containing roGFP2 are rapidly cooled to 77 K in a manner compatible with cryo-EM, the ratio of excitation peaks remains a faithful indicator of the redox potential at the time of freezing. Using purified protein in different oxidizing/reducing environments, we generate a calibration curve which can be used to analyze in situ measurements. As a proof-of-principle demonstration, we investigate the oxidation/reduction state within vitrified Caulobacter crescentus cells. The polar organizing protein Z (PopZ) localizes to the polar regions of C. crescentus where it is known to form a distinct microdomain. Finally, by expressing an inducible roGFP2-PopZ fusion we visualize individual microdomains in the context of their redox environment.

59 BASIC BIOLOGICAL SCIENCES↗

Biochemical properties of glycerol kinase from the hypersaline-adapted archaeon Haloferax volcanii

ABSTRACT Extremophilic microorganisms are promising candidates for industrial and analytical biocatalysis.Haloferax volcanii, a halophilic archaeon that prefers glycerol over glucose, channels this substrate into central metabolism through glycerol kinase (GK). Here, we report the biochemical properties ofH. volcaniiGK and its potential for biotechnological applications. An N-terminal His-tagged GK was functionalin vivoand yielded 3 mg/L culture—4.5 times more enzyme than a C-terminal StrepII-tagged version. Size exclusion chromatography revealed a glycerol-induced oligomeric shift from homodimer to a dimer-dominant state with detectable tetramer. The purified enzyme showed robust activity across broad pH and salinity ranges, with optimal activity at 100 mM NaCl and 50°C–60°C. It retained catalytic activity in 5%–10% dimethyl sulfoxide (DMSO) and crude glycerol containing methanol. His-GK was freeze-thaw stable and thermotolerant in 2 M NaCl buffers. In the absence of ligands, the enzyme’s melting temperature (T m ) was 80°C. Glycerol increased the T m to 85°C, and combinations with MgCl₂ (84°C) or ATP (88°C) provided further stabilization. The highest T m (89°C) occurred with all three ligands, suggesting a cumulative stabilizing effect. Kinetic analyses revealed positive cooperativity for glycerol, ATP, and Mg² + ; Mn² + and Co² + also supported the activity.H. volcaniiGK is the first known GK to exhibit positive cooperativity with glycerol and ATP. Its high stability and substrate flexibility support its use in biodiesel waste valorization,in vitrobiocatalysis, and biosensor development—applications demanding robust, specific, and stable enzymes. IMPORTANCE This study reveals thatH. volcaniiGK exhibits positive cooperativity for glycerol, ATP, and Mg² + , a kinetic feature not previously reported for glycerol kinases. This behavior enables steep, switch-like responses to small substrate changes, offering unique advantages for biosensor design. Importantly,H. volcaniiGK also maintains high activity under extreme salinity, temperature, broad pH, and solvent conditions that typically limit enzyme use in industrial and environmental applications. These traits make this GK an ideal candidate for enzyme-based biosensors, which often suffer from poor tolerance to pH, solvent, and thermal stress. Its robustness supports its use in cross-linked enzyme crystals, an immobilization method that enhances enzyme stability and reusability under harsh conditions. Moreover, GKs are already employed in Mg² + detection kits; however,H. volcaniiGK’s ability to tolerate and respond to diverse divalent cations (e.g., Co² + , Mn² + ) broadens their potential for pollutant detection and environmental monitoring. These features collectively positionH. volcaniiGK as a valuable biocatalyst for biosensing,in vitrodiagnostics, and biotechnological applications requiring both precision and durability.

Biotechnology & Applied Microbiology↗

Investigating Biological Responses to Space-like Radiation using the yeast Saccharomyces cerevisiae

As we plan crewed missions to the Moon, Mars, and beyond, it is essential to understand how persistent exposure to space radiation affects biology. Unlike on the International Space Station, where crew support and sample return are possible, experiments for long-duration missions require autonomous systems with no sample return. Human cells would be ideal biosensors, but limitations in culture methods, extended prelaunch storage, and long flight durations make it very difficult to keep human cells alive. Unlike other model systems, yeast can survive the constraints of long-duration spaceflight. Despite a billion years of evolution separating yeast from humans, we share homology in hundreds of genes important for basic cell function, including responses to DNA damage. Thus, yeast are excellent biosensors for detecting types/extent of damage induced by space radiation. BioSentinel is NASA’s latest biological CubeSat, and first interplanetary space bioscience mission. BioSentinel is manifested on Artemis 1, the first test flight of NASA’s Space Launch System, in the coming year. The BioSensor payload within BioSentinel contains two yeast strains. The wild type serves as a control for health and “normal” DNA damage repair (DDR). The rad51 deletion mutant is defective for DDR and will undergo alterations to growth and metabolism as it accumulates radiation damage. Changes in growth and metabolic activity will be measured using a 3-color LED detection system and the metabolic redox dye alamarBlue®. Preliminary tests indicate a significant change in alamarBlue response to space-like, low-dose ionizing radiation. We will discuss these findings in four parts – Introduction to biological CubeSats and the BioSentinel mission (presented by Sergio Santa Maria), preliminary responses to space-like ionizing radiation (presented here), a deeper dive into tracking metabolic changes after exposure to ionizing radiation (presented by Diana Gentry), and a look into methods for correcting flight optical data (presented by Abbey Kim). This work is funded by NASA’s Advanced Exploration Systems.

CubeSat↗

Investigating Molecular Responses to Space Radiation for Biological Missions Beyond Low Earth Orbit

As we plan crewed missions to the Moon, Mars, and beyond, it is essential to understand how persistent exposure to deep space radiation affects biology. Unlike on the International Space Station (ISS), where crew support and sample return are possible, experiments for long-duration missions require autonomous systems with no sample return. Human cells would be ideal biosensors, but limitations in culture methods, extended prelaunch storage, and long flight durations make it difficult to keep human cells alive. Unlike other model systems, yeast can survive the constraints of long-duration spaceflight. Despite a billion years of evolution separating yeast from humans, we share homology in hundreds of genes important for basic cell function, including responses to DNA damage. Thus, yeast are excellent biosensors for detecting types/extent of damage induced by space radiation. BioSentinel is NASA’s latest biological CubeSat, and first interplanetary space bioscience mission. BioSentinel is launching on Artemis 1, the first flight of NASA’s Space Launch System, in 2022. The BioSensor payload within BioSentinel contains two yeast strains. The wild type serves as a control for health and normal DNA damage repair (DDR). The rad51 deletion mutant is defective for DDR and will undergo alterations to growth and metabolism as it accumulates radiation damage. Changes in growth and metabolic activity will be measured using a 3-color LED detection system and the metabolic redox dye alamarBlue®. Preliminary tests indicate a significant change in alamarBlue responses to space-like, low-dose ionizing radiation. We will discuss these findings in five parts – Introduction to NASA’s biological CubeSats and BioSentinel (presented by Sergio Santa Maria), analysis of flight data from the ISS mission (presented by Kylie Akiyama), preliminary molecular responses to space radiation (presented here), a deeper dive into those pathways (presented by Kyra Keenan), and characterizing stress response through redox potential data (presented by Diana Gentry).

Lauren Courtney Liddell↗

LEIA: An Investigation of Radiation Risks to Biology at the Lunar South Pole

Radiation and reduced gravity pose biological risks to crewed deep space exploration. At the cellular level, radiation damage can be amplified by reduced gravity. Empirical evidence on cellular responses to beyond low Earth orbit (BLEO) environments is imperative to develop effective countermeasures for crew health and in-space biomanufacturing. The Lunar Explorer Instrument for Space Biology Applications (LEIA) project is developing an instrument suite to be delivered to the south polar region of the Moon by the Commercial Lunar Payload Services (CLPS) program. This presentation will provide an overview of the LEIA hardware, experiments, and mission timeline. The LEIA instruments include the BioSensor, the ARES charged particle detector, and the Mini-FND. The BioSensor is an autonomous light emitting diode (LED)-based spectrophotometer and microfluidic incubator. The BioSensor activates yeast cultures and can measure cell growth, metabolic activity, and carotenoid production. The ARES is a Timepix-based charged particle radiation detector that measures dose, dose rate, and linear energy transfer spectra. The Mini-FND is a fast neutron detector that measures albedo neutron flux and energy spectra. Combined, these instruments will be used for yeast genetics experiments to quantify growth, metabolism, and synthetic biology-enabled production of human nutrients, while taking real time measurements of biologically relevant radiation exposure on the lunar surface. These data will be used to test the importance of selected DNA damage repair and reactive oxygen species defense pathways in mitigating cellular damage from lunar surface radiation.

Yeast↗

Microbial Optical Data Processing: A Key Step in the Metabolic Assessment of Lunar Explorer Instrument for Space Biology Applications (LEIA) and Biosentinel’s Payload Data

The BioSensor payload platform on BioSentinel and LEIA autonomously collects optical data from microbial model organisms in liquid culture. The BioSensor is designed to monitor metabolic activity using absorbance measurements of cell density and alamarBlue, a readily available colorimetric redox indicator dye. BioSentinel, a pioneering NASA CubeSat, uses yeast to study deep space radiation. LEIA investigates radiation and lunar gravity response. The experimental setup includes 16 wells equipped with three LEDs (570, 630, and 850 nm) and their corresponding photodetectors. One well is a calibration control without biology while the rest have desiccated cultures. Autonomous rehydration initiates the experiment. Data from the BioSensor are received from the flight and ground units, enabling comparison to uncover location-based metabolic rate variations. This study presents a Python Jupyter notebook developed for efficient data processing of multiple CSV files containing date and time columns, temperature, and well illumination data. It offers a user-friendly interface while maintaining computational power, automatically recognizing and iteratively processing data files in a user-input path. A Hampel filter with a short window eliminates outlier artifacts from sensor dropout. Because absorbance is a relative measurement, conversion from raw illumination requires defining a “blank” value, so the first data points are averaged to provide the necessary denominator. A cube-root function correction mitigates undesired drift caused by air pockets during the fluidic card filling phase, maintaining optical path length consistency. Beer-Lambert's law is applied to further convert absorbance values to cell and dye form concentrations, the desired science parameters. The processed data are saved and visualized as SVG plots. Future plans include extracting specific science parameters from the processed data like growth rate and metabolic rate, and identification of features corresponding to metabolic and phenotypic shifts such as starvation, shifts from aerobic to anaerobic growth, and osmotic stresses.

Space biology↗

Developing Flexible Instruments for Biological Missions Beyond Low Earth Orbit

As the future of spaceflight focuses on human exploration beyond low Earth orbit (BLEO), space biology experiments using model organisms are becoming increasingly important. NASA’s Artemis missions seek to build technologies that enable extended crewed flights into deep space, a region not travelled by humans for over 50 years. From the Apollo missions and ground experiments, it is known that BLEO galactic cosmic radiation can cause damage to DNA and proteins, as well as an increased risk of cancer to astronauts. NASA’s latest biosensor technology, the Lunar Explorer Instrument for space biology applications (LEIA), builds upon the viable and cost-effective platform of CubeSats to take biology experiments back to the Moon. Stationed on the lunar South Pole, LEIA will collect valuable in-situ radiation data, and use yeast to study the response to combined partial gravity and radiation stressors, as well as provide a proof-of-concept of on-demand bio nutrient production as a countermeasure for future crewed missions. Directly enhancing the abilities of the BioSentinel CubeSat mission, the main components of LEIA are the two radiation sensors and the 4U BioSensor, composed of 16-microfluidic cards housing dried yeast cells. The payload is fully contained and autonomous, directly sending data back to Earth without the need for sample return. In addition, the thermal environment of the BioSensor is optimized to keep cells alive for the pre-launch period and duration of the Artemis III mission, while also running on limited power supply. This talk highlights how the development of flexible instruments, like LEIA, enables human exploration into deep space. The technology developed with LEIA can be used as a stepping-stone for establishing a sustained lunar surface habitation and beyond, as humans continue to venture into space.

Payne Elizabeth Turney↗

LEIA: An Investigation of Radiation Risks to Biology at the Lunar South Pole

Radiation and reduced gravity pose biological risks to crewed deep space exploration. At the cellular level, radiation damage can be amplified by reduced gravity. Empirical evidence on cellular responses to beyond low Earth orbit (BLEO) environments is imperative to develop effective countermeasures for crew health and in-space biomanufacturing. The Lunar Explorer Instrument for Space Biology Applications (LEIA) project is developing an instrument suite to be delivered to the south polar region of the Moon by the Commercial Lunar Payload Services (CLPS) program. This presentation will provide an overview of the LEIA hardware, experiments, and mission timeline. The LEIA instruments include the BioSensor, the ARES charged particle detector, and the Mini-FND. The BioSensor is an autonomous light emitting diode (LED)-based spectrophotometer and microfluidic incubator. The BioSensor activates yeast cultures and can measure cell growth, metabolic activity, and carotenoid production. The ARES is a Timepix-based charged particle radiation detector that measures dose, dose rate, and linear energy transfer spectra. The Mini-FND is a fast neutron detector that measures albedo neutron flux and energy spectra. Combined, these instruments will be used for yeast genetics experiments to quantify growth, metabolism, and synthetic biology-enabled production of human nutrients, while taking real time measurements of biologically relevant radiation exposure on the lunar surface. These data will be used to test the importance of selected DNA damage repair and reactive oxygen species defense pathways in mitigating cellular damage from lunar surface radiation.

Yeast↗

A split luciferase system for studying coronavirus Mpro dimerization in vitro and in living cells

The main protease enzyme (Mpro) of coronaviruses cleaves the viral polyprotein into functional units essential for virus replication. Prior work has demonstrated that Mpro functions as a homodimer. However, studies on the mechanism of dimerization have been challenging because the purified protease is mostly dimeric, dimerization-defective mutants lack proteolytic activity, and robust cell-based assays have yet to be reported. To enable work on Mpro dimerization, we have developed a quantitative luciferase-based SARS-CoV-2 (SARS2) Mpro biosensor that accurately reports protein dimerization in living cells and, upon purification, also in vitro. Co-transfection of cells with a construct expressing Mpro fused to the 18 kDa LargeBiT of luciferase (LgBiT) and a second construct with Mpro fused to the 1 kDa SmallBiT of luciferase (SmBiT) results in a reconstitution of luciferase activity in a dose-dependent manner that requires conserved residues within the dimerization interface. Proteolytic activity is dispensable for dimerization and, uniquely, a C145A catalytically inactive mutant exhibits enhanced dimerization signal likely due to lower cytotoxicity. Mpro enzymes from multiple different coronaviruses also dimerize in this system, indicating mechanistic conservation. Interestingly, this dimerization biosensor also provides a quantitative read-out of inhibitor-facilitated dimerization. Covalent SARS2 Mpro inhibitors such as nirmatrelvir cause a 3- to 5-fold increase in luciferase activity. Together with corroborating structural, biophysical, and molecular dynamics experiments, our studies support a model in which covalent Mpro inhibitors such as nirmatrelvir simultaneously block catalytic activity and induce allosteric stabilization of the dimeric complex.

SARS-CoV-2 main protease (Mpro/3CLpro)↗

Rapid discovery and evolution of nanosensors containing fluorogenic amino acids

Binding-activated optical sensors are powerful tools for imaging, diagnostics, and biomolecular sensing. However, biosensor discovery is slow and requires tedious steps in rational design, screening, and characterization. Here we report on a platform that streamlines biosensor discovery and unlocks directed nanosensor evolution through genetically encodable fluorogenic amino acids (FgAAs). Building on the classical knowledge-based semisynthetic approach, we engineer ~15 kDa nanosensors that recognize specific proteins, peptides, and small molecules with up to 100-fold fluorescence increases and subsecond kinetics, allowing real-time and wash-free target sensing and live-cell bioimaging. An optimized genetic code expansion chemistry with FgAAs further enables rapid (~3 h) ribosomal nanosensor discovery via the cell-free translation of hundreds of candidates in parallel and directed nanosensor evolution with improved variant-specific sensitivities (up to ~250-fold) for SARS-CoV-2 antigens. Altogether, this platform could accelerate the discovery of fluorogenic nanosensors and pave the way to modify proteins with other non-standard functionalities for diverse applications.

Biosensors↗

Functional Imaging of Microbial Interactions With Tree Roots Using a Microfluidics Setup

Coupling microfluidics with microscopy has emerged as a powerful approach to study at cellular resolution the dynamics in plant physiology and root-microbe interactions (RMIs). Most devices have been designed to study the model plant Arabidopsis thaliana at higher throughput than conventional methods. However, there is a need for microfluidic devices which enable in vivo studies of root development and RMIs in woody plants. Here, we developed the RMI-chip, a simple microfluidic setup in which Populus tremuloides (aspen tree) seedlings can grow for over a month, allowing continuous microscopic observation of interactions between live roots and rhizobacteria. We find that the colonization of growing aspen roots by Pseudomonas fluorescens in the RMI-chip involves dynamic biofilm formation and dispersal, in keeping with previous observations in a different experimental set-up. Also, we find that whole-cell biosensors based on the rhizobacterium Bacillus subtilis can be used to monitor compositional changes in the rhizosphere but that the application of these biosensors is limited by their efficiency at colonizing aspen roots and persisting. These results indicate that functional imaging of dynamic root-bacteria interactions in the RMI-chip requires careful matching between the host plant and the bacterial root colonizer.

59 BASIC BIOLOGICAL SCIENCES↗

Real-time bioelectronic sensing of environmental contaminants

Real-time chemical sensing is crucial for applications in environmental and health monitoring. Biosensors can detect a variety of molecules through genetic circuits that use these chemicals to trigger the synthesis of a coloured protein, thereby producing an optical signal. However, the process of protein expression limits the speed of this sensing to approximately half an hour, and optical signals are often difficult to detect in situ. Here we combine synthetic biology and materials engineering to develop biosensors that produce electrical readouts and have detection times of minutes. Here we programmed Escherichia coli to produce an electrical current in response to specific chemicals using a modular, eight-component, synthetic electron transport chain. As designed, this strain produced current following exposure to thiosulfate, an anion that causes microbial blooms, within 2 min. This amperometric sensor was then modified to detect an endocrine disruptor. The incorporation of a protein switch into the synthetic pathway and encapsulation of the bacteria with conductive nanomaterials enabled the detection of the endocrine disruptor in urban waterway samples within 3 min. Our results provide design rules to sense various chemicals with mass-transport-limited detection times and a new platform for miniature, low-power bioelectronic sensors that safeguard ecological and human health.

59 BASIC BIOLOGICAL SCIENCES↗